| 1 | 16 KVA SP Mounted S/SWPB (GI) Pole 160x152 (11Mtr. Long, 30.44KG/Mtr.)(Total Pole Weight with Base Plate & Stiffner=334.84 KG+10.74 KG= 345.58 KG) |
| 2 | Top Channel(GI) GI 100 X 50 X 6 MM (1200 mm long) (9.56Kg./Mtr, 2 No's.) (Each 2x1.200x9.56= 22.94 Kg) |
| 3 | Fish Plate(GI) 50x6 mm., 2.36 kg/Mtr., Noch 0.280 mtr. length, 4 No's required = (4x2.36x0.280) |
| 4 | Transformer Mounting Bracket (65x65x6 GI Angle(GI)) suitable for 16/10KVA 11/0.23 KV Transformer |
| 5 | AB Switch Mounting Channel(GI) 75x40x4.8 mm GI Channel(GI) (2000 mm long)(7.14Kg./Mtr., 2 No's.) (Each 2x2.000x7.14= 28.56 Kg) |
| 6 | Cantilever Support Angle(GI) 50 X 50 X 6MM GI (1282 mm long) (4.5Kg./Mtr, 2 No's.) (Each 2x1.282x4.5= 11.54Kg) |
| 7 | HG/ DO Fuse Mounting Channel(GI) 75x40x4.8 mm GI Channel(GI) (2000 mm long)(7.14Kg./Mtr., 2 No's.) (Each 2x2.000x7.14= 28.56 Kg) |
| 8 | 25x3mm Flat(GI) for earthing, 0.59kg/mtr., (2.5x7 mtr. For mesh formation, 12 Mtr. For LA and 2.5 mtr. For raising, 11 mtr for AB switch, 2.8 mtr for HG Fuse, 5x2 mtr. for DTR Nutral, (1.3+4.5) mtr. For DTR Body, 0.500 mtr for LTDB & AB Switch operating handle) ( Each 62.6x 0.59= 36.93 Kg) |
| 9 | LT Dist. Box with MCCB for 16KVA S/S. |
| 10 | 55 SQ.MM. AAAC XLPE Covered Conductor |
| 11 | 2Cx16 mm2 LT XLPE Cable(armoured) |
| 12 | AB Switch(11KV,200A.2pole,50Hz) |
| 13 | H.G.Fuse( 11KV.200A.2Pole) |
| 14 | WEDGE CONNECTOR FOR 55 SQMM.CONDUCTOR |
| 15 | POLYCARBONATE BIRD GUARD |
| 16 | Disc insulator (B&S)70 KN polymer |
| 17 | H W fitting (B&S)70KN(3bolted) |
| 18 | Lightning Arrester(12KV,10KA) Station Class 2 |
| 19 | 11KV pin insulator polymer |
| 20 | HT stay set complete |
| 21 | HT stay Clamp (1.9Kg/pair) |
| 22 | HT stay insulator TYPE-C |
| 23 | 7/10 SWG GI stay wire, Grade -2 (15Kg./ Set) |
| 24 | 40 mm Nominal bore GI pipe (medium gauge) earthing device with 3 mtr .Long |
| 25 | GI Nuts & Bolts of Assorted size (15 Kg/ DSS SP) |
| 26 | GI Barbed wire/Anticlimbing device (3Kg /Pole) |
| 27 | Back Clamp for anticlimbing device 25X3 mm. Flat(GI), 0.59Kg/Mtr. Flat(GI) of 0.510mtr length 4 No's = (4x0.59x0.510) |
| 28 | Danger plate 11kv |
| 29 | Back Clamp for danger Plate 25X3 mm. Flat(GI), 0.59Kg/Mtr. Flat(GI) of 0.510mtr length 1 No's (Noch 1x0.59x0.510) |
| 30 | Name plate |
| 31 | Yellow Colour Paint(GIS Numbering & Zebra Stripping) for Background |
| 32 | Black Colour Paint(GIS Numbering & Zebra Stripping) for numbering |
| 33 | Concreting ratio 1:1.5:3(M-20 Grade) (500mmX500mmX1800mm) = 0.450Cu.mtr(Per Pole) |
| 34 | Couping ratio 1:1.5:3(M-20 Grade) (500mmX500mmX450mm) = 0.113Cu.mtr(Per Pole) |
| 35 | PCC ratio 1:3:6(M-10 Grade) For DSS Area (3X2X0.1)= 0.6 Cu. mtr. |
| 36 | Fixing of stay set with 0.5Cum cement concrete foundation 1:3:6(M-10 Grade) size ( 900mmx600mmx900mm) using 40mm BHG metal with all labor and material except stay set , stay wire , stay insulator . |
| 37 | Construction Earthing chamber including installation of earthing pipe.Making earthing chamber including excavation , soil treatment with bentonide powder , calculation of earthresistance, including Installation of 3Mtr GI Pipe 40mm/50mm including welding of Flat(GI)around pipe . |
| 38 | Laying of 2 Cx 16 mm2 LT PVC Cable |
| 39 | Supply of AL Lugs suitable for 16 sq mm cable/conductor, Crimping with cable and Fixing/connecting include supply and erection of PVC Tape as per voltage requirement. |
| 40 | SITC and Erection of GI Fencing with Gate |
| 41 | Inspection fee of Over Head Line & drawing Checking |
| 42 | LT Line9 Mtr. long 300 Kg. PSC Pole |
| 43 | LT Stay set Complete |
| 44 | 7/12 SWG GI stay wire, Grade -2 |
| 45 | LT stay Clamp ( 1.40Kg/pair) |
| 46 | LT Stay insulator |
| 47 | Pole clamp for EYE hook for (XLPE Aerial bunched Cable) |
| 48 | EYE hook for XLPE Aerial bunched Cable |
| 49 | Dead End Clamp suitable for messenger XLPE Aerial bunched Cable |
| 50 | Suspension Clamp with EYE hook for ABC |
| 51 | 2x35+1x25 (LT AB Cable) |
| 52 | Insulated piercing connector.Type-B-main 25 to 150 sq.mm & Tap-6 to 35 sq.mm |
| 53 | GI Pipe Earthing (each 5th pole to earth) |
| 54 | Coil Earthing |
| 55 | No-8 GI wire (Dia 4.6mm) 0.131 KG/ Mtr.- 2 Mtr. For connecting pole with Coil earthing |
| 56 | Danger plate (LT) |
| 57 | Back Clamp for danger Plate 25X3 mm. Flat(GI), 0.59Kg/Mtr. Flat(GI) of 0.510mtr length 1 no's = (1x0.59x0.510) |
| 58 | GI barbed wire anticlimbing device 3 Kg. Per support |
| 59 | Back Clamp for anticlimbing device 25X3 mm. Flat(GI), 0.59Kg/Mtr. Flat(GI) of 0.510mtr length 4 no's = (4x0.59x0.510) |
| 60 | GI Nut , Bolt & Washer of different sizes (0.5 Kg/ Pole) |
| 61 | Black Paint(GIS Numbering & Zebra Stripping) |
| 62 | Yellow Colour Paint(GIS Numbering & Zebra Stripping) for Background |
| 63 | Fixing of LT Complete stay set includes 1) Turn Buckle Assembly 2) Stay Rod & Stay plate 3) Stay Insulator 4) Stay Wire. 5)Stay clamps with Nuts & bolts, including excvation, supply of 0.5Cum cement concrete foundation 1:2:4 size (500mmx500mmx800mm) using 20mm BHG metal with all labour and material (Excavation of earth will be done of size 500X500X1500 mm.) |
| 64 | Concreting ratio 1:1.5:3(M-20 Grade) (500mmX500mmX1500mm) = 0.375Cu.mtr(Per Pole) |
| 65 | Construction Earthing chamber including installation of earthing pipe.Making earthing chamber including excavation , soil treatment with bentonide powder , calculation of earthresistance, including Installation of 3Mtr GI Pipe 40mm/50mm including welding of Flat(GI)around pipe . |
| 66 | Inspection fee of Over Head Line & drawing Checking |
| 67 | DismantlingDismantling of 9/8 Mtr. PCC/Joist Pole |
| 68 | Dismantling of 11kV Pin Insulator with Pin |
| 69 | Dismantling of 11kV Disc Insulator with Hardware |
| 70 | Dismantling / Removal of MS Channel. from Double Pole Structure /pole |
| 71 | Dismantling of existing 11/0.4kV, 33/0.4KV, Three Phase Distribution Transformer 16KVA including removal of HT/LT leads, earth connections and unloading by crane if required. |
| 72 | Dismantling of varous size of LT AB Cable |
| 73 | Bella Chhaka to kantiapasi Kunjam road Via PaunsiaLT Line9 Mtr. long 300 Kg. PSC Pole |
| 74 | LT Stay set Complete |
| 75 | 7/12 SWG GI stay wire, Grade -2 |
| 76 | LT stay Clamp ( 1.40Kg/pair) |
| 77 | LT Stay insulator |
| 78 | Pole clamp for EYE hook for (XLPE Aerial bunched Cable) |
| 79 | EYE hook for XLPE Aerial bunched Cable |
| 80 | Dead End Clamp suitable for messenger XLPE Aerial bunched Cable |
| 81 | Suspension Clamp with EYE hook for ABC |
| 82 | 4C×50 mm² (P)+1C×50 mm²(M)+1CX16 mm²(Street Light) (LT AB Cable) |
| 83 | Insulated piercing connector.Type-A-main 50 to 150 sq.mm & Tap-50 to 150 sq.mm |
| 84 | GI Pipe Earthing (each 5th pole to earth) |
| 85 | Coil Earthing |
| 86 | No-8 GI wire (Dia 4.6mm) 0.131 KG/ Mtr.- 2 Mtr. For connecting pole with Coil earthing |
| 87 | Danger plate (LT) |
| 88 | Back Clamp for danger Plate 25X3 mm. Flat(GI), 0.59Kg/Mtr. Flat(GI) of 0.510mtr length 1 no's = (1x0.59x0.510) |
| 89 | GI barbed wire anticlimbing device 3 Kg. Per support |
| 90 | Back Clamp for anticlimbing device 25X3 mm. Flat(GI), 0.59Kg/Mtr. Flat(GI) of 0.510mtr length 4 no's = (4x0.59x0.510) |
| 91 | GI Nut , Bolt & Washer of different sizes (0.5 Kg/ Pole) |
| 92 | Black Paint(GIS Numbering & Zebra Stripping) |
| 93 | Yellow Colour Paint(GIS Numbering & Zebra Stripping) for Background |
| 94 | Fixing of LT Complete stay set includes 1) Turn Buckle Assembly 2) Stay Rod & Stay plate 3) Stay Insulator 4) Stay Wire. 5)Stay clamps with Nuts & bolts, including excvation, supply of 0.5Cum cement concrete foundation 1:2:4 size (500mmx500mmx800mm) using 20mm BHG metal with all labour and material (Excavation of earth will be done of size 500X500X1500 mm.) |
| 95 | Concreting ratio 1:1.5:3(M-20 Grade) (500mmX500mmX1500mm) = 0.375Cu.mtr(Per Pole) |
| 96 | Construction Earthing chamber including installation of earthing pipe.Making earthing chamber including excavation , soil treatment with bentonide powder , calculation of earthresistance, including Installation of 3Mtr GI Pipe 40mm/50mm including welding of Flat(GI)around pipe . |
| 97 | Inspection fee of Over Head Line & drawing Checking |
| 98 | DismantlingDismantling of 9/8 Mtr. PCC/Joist Pole |
| 99 | Dismantling of varous size of LT AB Cable Please Enable Macros to View BoQ information |