| 1 | Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. |
| 2 | Nominal concrete 1:4:8 or leaner mix (i/c equivalent design mix) |
| 3 | Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge.. |
| 4 | In cement mortar |
| 5 | Taking out doors, windows and clerestory window shutters (steel or wood) including stacking within 50 metres lead: |
| 6 | Of area 3 sq. metres and below |
| 7 | Dismantling C.I. or asbestos rain water pipe with fittings and clamps including stacking the material within 50 metres lead : |
| 8 | 75 to 80 mm dia pipe. |
| 9 | 100 mm dia pipe |
| 10 | Dismantling of flushing cistern of all types (C.I./PVC/Vitreous China) including stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead. |
| 11 | Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. |
| 12 | Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved. |
| 13 | Credit for: |
| 14 | Unserviciable Brass Bib/stop cocks/pillar tap |
| 15 | Low level PVC flush tanks (10 litres) |
| 16 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : |
| 17 | 1:2:4 (1 cement : 2 coarse sand(zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 18 | Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor, etc., up to floor five level, excluding the cost of centering, shuttering and finishing : |
| 19 | 1:1½:3 (1 cement : 1½ coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). |
| 20 | 1:5:10 (1 cement : 5 coarse sand (zone-III) derived from natural sources : 10 graded stone aggregate 40 mm nominal size derived from natural sources). |
| 21 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. |
| 22 | Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 23 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : |
| 24 | Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 25 | Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. |
| 26 | Cement mortar 1:4 (1 cement :4 coarse sand) |
| 27 | Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size,approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. |
| 28 | Granite stone slab colour black, Cherry/Ruby red |
| 29 | Area of slab upto 0.50 sqm |
| 30 | Area of slab over 0.50 sqm |
| 31 | Extra for providing opening of required size & shape for wash basin/kitchen sink in kitchen platform, vanity counter and similar location in marble/ Granite/ stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete |
| 32 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approvedmake, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. |
| 33 | Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: |
| 34 | 30 mm thick including ISI marked Stainless Steel butt hinges with necessary screws |
| 35 | Providing and fixing ISI marked oxidised M.S. sliding door bolts with nuts and screws etc. complete (Copper oxidised as per IS 1378) |
| 36 | 300x16 mm |
| 37 | 250x16 mm |
| 38 | Providing and fixing ISI marked oxidised M.S. tower bolt black finish, (Barrel type) with necessary screws etc. complete (Copper oxidised as per IS 1378) |
| 39 | 200x10 mm |
| 40 | Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete : |
| 41 | 200x10 mm |
| 42 | Providing and fixing bright finished brass handles with screws etc. complete: |
| 43 | 125 mm |
| 44 | 100 mm |
| 45 | Providing and fixing aluminium sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete : |
| 46 | 300x16 mm |
| 47 | 250x16 mm |
| 48 | Providing & Fixing decorative high pressure laminated sheet of plain / wood grain in gloss / matt / suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS : 2046 Type S, including cost of adhesive of approved quality. |
| 49 | 1.0 mm thick. |
| 50 | Providing and fixing cuboard shutter with 19 mm thick one side decorative and other side balancing lamination factory pressed BWP grade marine ply as per IS 710 of approved brand including 2 mm thick PVC edege banding tape with hot glue by edege bending machine etc. with auto closing spring loaded hinges (hydraulic type) etc. complete as per direction of Engineer-in-charge. (Payment of providing and fixing auto closing hinges shall be paid separately) |
| 51 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : |
| 52 | For fixed portion |
| 53 | Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15) |
| 54 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): |
| 55 | With float glass panes of 4.0 mm thickness (weight not less than 10 kg/sqm) |
| 56 | With float glass panes of 5 mm thickness (weight not less than 12.50 kg/sqm) |
| 57 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. |
| 58 | Hot finished welded type tubes. |
| 59 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm(thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement :4 Coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including pointing the joints with white cement and matching pigment etc.,., complete. |
| 60 | Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. |
| 61 | Glazed Vitrified tiles Matt/Antiskid finish of size |
| 62 | Size of Tile 600 x 600 mm |
| 63 | Providing and fixing on wall face unplasticised - PVC moulded fittings/accessories for unplasticised Rigid PVC rain water pipes conforming to IS 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. |
| 64 | Coupler |
| 65 | 110mm |
| 66 | Single tee with door |
| 67 | 75x75x75 mm |
| 68 | 110x110x110 mm |
| 69 | Single tee without door |
| 70 | 75x75x75 mm |
| 71 | 110x110x110 mm |
| 72 | Shoe (Plain) |
| 73 | 75 mm Shoe |
| 74 | 110 mm Shoe |
| 75 | Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. |
| 76 | 75 mm |
| 77 | 110 mm |
| 78 | Providing and fixing unplasticised rigid pvc SWR fittings conforming to IS : 13592 Type B, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. |
| 79 | (a) 110mm Y - Tee |
| 80 | Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : |
| 81 | (a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. This layer will be allowed to air cure for 4 hours. |
| 82 | (b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. |
| 83 | The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry. |
| 84 | 12 mm cement plaster of mix : |
| 85 | 1:6 (1 cement: 6 coarse sand) |
| 86 | 15 mm cement plaster on rough side of single or half brick wall of mix : |
| 87 | 1:6 (1 cement: 6 coarse sand) |
| 88 | 6 mm cement plaster of mix : |
| 89 | 1:3 (1 cement: 3 fine sand) |
| 90 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 91 | Distempering with 1st quality acrylic distemper (ready mixed) having VOC (Volatile Organic Compound ) content less than 50 gram/ litre, of approved brand and of required shade and colour complete to give and even shade. |
| 92 | Old work (one or more coats) |
| 93 | Wall painting with acrylic emulsion paint, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour. |
| 94 | Two coats. |
| 95 | Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre. of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. |
| 96 | One coat. |
| 97 | Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound ) content. |
| 98 | With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre. |
| 99 | Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. |
| 100 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : |
| 101 | One or more coats on old work. |
| 102 | Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq.meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-harge. |
| 103 | With cement mortar 1:4 (1 cement : 4 fine sand). |
| 104 | Renewing glass panes, with putty and nails wherever necessary including racking out the old putty: |
| 105 | Float glass panes of nominal thickness 4 mm (weight not less than 10kg/sqm). |
| 106 | Disconnecting damaged overhead/terrace PVC water storage tank of any size from water supply line and removing from the terrace including shifting at ground level as per direction of Engineer-in- charge. |
| 107 | Cleaning of chocked sewer line including cleaning manhole by manual or mechanical means including disposal of debris in municipal dumping ground complete as per direction of Engineer-in-charge. |
| 108 | Providing and applying damp-proofing treatment on internal plastered brick or concrete wall surfaces affected by rising dampness, efflorescence, or salt formation using ready-to-use waterproofing chemical of approved make such as Asian Paints Hydroloc, Dr. Fixit Dampguard Classic, or Berger Dampstop, in two coats with brush or roller, including surface preparation by wire brushing, scraping off loose material, removal of existing flaking paint or salt deposits, pre-wetting of the surface, and curing, all complete as per manufacturer’s specifications and as directed by the Engineer-in-Charge. |
| 109 | Supplying, filling, spreading & leveling crushed stone aggregate(BT) of size range 5 mm to 10 mm, over the existing layer of consolidated moorum, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. \\" |
| 110 | Supplying, filling, spreading & leveling with red moorum/ Kopra in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m. over the sub grade in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. |
| 111 | Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings andfixtures complete, including cutting and making good the walls and floors wherever required : |
| 112 | W.C. pan with ISI marked white solid plastic seat and lid |
| 113 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: |
| 114 | White Vitreous China Flat back wash basin size 550x 400 mm with single 15 mm C.P. brass pillar tap |
| 115 | Extra for using coloured pedestal type W.C pan (European type) with low level cistern of same colour instead of white vitreous china W.C pan and cistern. |
| 116 | Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in - charge. |
| 117 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. |
| 118 | Semi rigid pipe |
| 119 | 32 mm dia |
| 120 | Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. |
| 121 | Providing and fixing on wall face unplasticised Rigid PVC SWR grade Soil, waste, vent pipes conforming to IS : 13592 Type A, including jointing with seal ring IS : 5382, leaving 10 mm gap for thermal expansion,conforming to IS : 13592: Single socketed pipes. |
| 122 | 75 mm diametre |
| 123 | 110 mm diametre |
| 124 | Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC SWR grade Soil, waste, vent conforming Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion.to IS : 13592 |
| 125 | Bend 87.5° with door |
| 126 | 75 mm |
| 127 | 110 mm |
| 128 | Bend 87.5° without door |
| 129 | 75 mm |
| 130 | 110 mm |
| 131 | Providing and fixing white vitreous china flat back half stall urinal of size 580x380x350 mm with fittings, standard size C.P. brass waste coupling, C.P. spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS : 2556,with waste couplings in C.P. brass, including painting of fittings including bracket , faster etc as per direction of Engineer in charge |
| 132 | (a) Single half stall urinal of 580x380x350 |
| 133 | Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main \\"T\\" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross \\"T\\" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main \\"T\\" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross \\"T\\" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in |
| 134 | the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. |
| 135 | Main \\"T\\" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge. ( All work Make Armstrong or equivalents) |
| 136 | 8 mm thick square edge PVC Laminated Gypsum Tile of size 595x595 mm, made of Gypsum plasterboard and laminated with white 0.07 mm thick fire retardant PVC film on the face side and 12 micron metalized polyester on the back side with all edges sealed with the face side PVC film which goes around and wraps the edges and is bonded to the edges and the back side metalized polyester film so as to make the tile a completely sealed unit. (Tile work Make Gyproc-Saint Gobain or equivalents) |
| 137 | Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC SWR grade Soil, waste, vent pipes conforming Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion.to IS : 13592 |
| 138 | Single 'Y' with door |
| 139 | 110mm x 110mm x 110mm |
| 140 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. : Internal work - Exposed on wall |
| 141 | 32 mm nominal outer dia. Pipes. |
| 142 | 40 mm nominal outer dia. Pipes. |
| 143 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. :Concealed work, including cutting chases and making good the walls etc. |
| 144 | 20 mm nominal outer dia .Pipes. |
| 145 | Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete : |
| 146 | 25 to 40 mm nominal bore |
| 147 | Providing and fixing brass stop cock of approved quality : |
| 148 | 20 mm nominal bore |
| 149 | Providing and fixing uplasticised PVC connection pipe with brass unions : |
| 150 | 45 cm length |
| 151 | 15 mm nominal bore |
| 152 | Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 : |
| 153 | 15mm nominal bore |
| 154 | Providing and fixing PTMT grating of approved quality and colour. |
| 155 | Circular type. |
| 156 | 100 mm nominal dia. |
| 157 | Rectangular type with openable circular lid. |
| 158 | 150 mm nominal size square 100 mm diameter of the inner hinged round grating. |
| 159 | Providing and fixing Stainless Steel grating 0.60mm thick grating for floor traps complete as directed. |
| 160 | 100mm dia Circular |
| 161 | Providing and fixing PTMT Ball cock of approved quality, colour and make complete with Epoxy coated aluminium rod with L.P./ H.P.H.D. plastic ball. |
| 162 | 20 mm nominal bore, 120 mm long. Weighing not less than 198 gms. |
| 163 | Cutting holes up to 30x30 cm in walls including making good the same: |
| 164 | With common burnt clay F.P.S. (non modular) bricks. |
| 165 | Credit for |
| 166 | a) Unserviceable G.I.pipe |
| 167 | Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design : |
| 168 | Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) : |
| 169 | Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design : |
| 170 | (a) Inside size 90x80 cm and 45 cm deep including Providing and fixing in position pre-cast R.C.C. manhole cover and frame of LD-2.5 , Rectangular shape 600x450 mm internal dimensions |
| 171 | Providing and fixing in position pre-cast R.C.C. manhole cover and frame of required shape and approved quality |
| 172 | L D - 2.5 |
| 173 | Rectangular shape 600x450 mm internal dimensions |
| 174 | Constructing brick masonry road gully chamber 50x45x60 cm with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) including 500x450 mm pre-cast R.C.C. horizontal grating with frame complete as per standard design : |
| 175 | With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 176 | Providing, mixing and applying bonding coat of approved adhesive on chipped portion of RCC as per specifications and direction of Engineer-In-charge complete in all respect. |
| 177 | SBR Polymer (@10% of cement weight) modified cementitious bond coat @ 2.2 kg cement per sqm of surface area mixed with specified proportion of approved polymer |
| 178 | Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/ Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/ borer proof, water/ moisture proof and fire retardant and fixed in position with M.S hold fast/ lugs/ SS dash |
| 179 | fasteners of required dia and length complete as per direction of Engineer-In- Charge. |
| 180 | (M.S hold fast/ lugs or SS dash fasteners shall be paid for separately). Note: For WPC solid door/ window frames, minus 5mm tolerance in dimensions i.e depth and width of profile shall be acceptable. Variationin profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made. |
| 181 | Frame size 50 x 125 mm |
| 182 | Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In- Charge. |
| 183 | (Note: stainless steel butt hinges and necessary S.S screws shall be paid separately) |
| 184 | 30 mm thick Please Enable Macros to View BoQ information |