| 1 | Supplying and laying of following size HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. direct in ground, providing boring by trenchless technology with no dig method by making bore hole in horizontal direction across the road as per direction of Engineer-in-charge or his representative with moling equipment i/c jointing cleaning, rodding of pipe providing suitable covers on mouth of pipes, excavation of pits of required size at a following depth i/c refilling etc. complete as reqd. upto 2.5 Mtr. depth |
| 2 | 63 mm dia (OD-63 mm & ID-51 mm nominal) |
| 3 | Supplying and laying of following PVC insulated and PVC sheathed /XPLE armounrd Aluminum Conductor power cable of 1.1 KV grade of following size in the existing RCC/ HUME/DWC/METAL pipe as required. |
| 4 | 3.50 X 50 Sq. mm |
| 5 | 4 x 25 Sq. mm (cable colour - Yellow) and PWD shall be embossed marked on the cable |
| 6 | 4x16 sq mm (cable colour - Yellow) and PWD shall be embossed marked on the cable |
| 7 | Supplying and Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required. |
| 8 | 3.50 X 50 Sq. mm |
| 9 | 4 x 25 Sq. mm (cable colour - Yellow) and pwd shall be embossed marked on the cable |
| 10 | 4x16 sq mm (cable colour - Yellow) and pwd shall be embossed marked on the cable |
| 11 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required. |
| 12 | 3.5 X 50 sq. mm (35 mm) |
| 13 | 4 X 16 sq. mm (28 mm) |
| 14 | 4 X 25 sq. mm (28 mm) |
| 15 | Earthing with G.I. earth pipe 4.5 Meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. |
| 16 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ubmain wiring/ cable as required. |
| 17 | Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, Ics=100% Icu and Operational Voltage 690V etc. as required. |
| 18 | 100 A,30KA,FPMCCB |
| 19 | 125 A,36KA,FPMCCB |
| 20 | Supplying & Fixing of Astronomical time switch of following configuration to be mounted in feeder pillars / Lighting DBs for automatic switching On & OFF of street lights at sun set & sun rise or twilight(Auto ON, Auto OFF, Auto modes) with manual override facility with 12/24 hour display format with suitable battery and indication for relay status i/c programming at site complete as required.3 output (1output per phase) and suitable for three phase supply |
| 21 | Fabrication, supplying & fixing triple/single/ double galvanized arm bracket of suitable length and dia as required on site i/c tightening bolts etc. as reqd. |
| 22 | Fabricating, Supplying and fixing wire mesh protection frame work made out of 40 x 40 mm x 6 mm thick angle and \\"T\\" strengthened with intermediate menberers of MS flat iron of size 32 x 6 mm x 5 mm thick welded at a distance of 30 cm horizontally and vertically and duly welded with wiremesh of size 75 mm x 25 mm made with 6 SWG wire mesh of size 75 mm x 25 mm made with 6 SWG wire on all sides and top i/c providing and fixing of double door gate with double locking arrangement ( Two nos. sliding bolts and one No. go down lock) having 0.5 mtr long legs of 40 mm x 40 mm x 6 mm thick angles iron, duly grouted in cement concrete foundation ration 1:2:4 (1 cement : 2 coarse sand: 4 graded stone aggregate) upto suitable depth painting with on coast of red oxide & two coats of synthetic enamel paint of approval colour and shade etc. complete as reqd. |
| 23 | SITC of DWC/HDPE pipe for covering the street light pole of dia upto 200 mm and height minimum 2 Mtr. including cutting jointing etc. with the help of hydra/Tower wagon, pipe must be fixed to the pole from above side to the bottom by removing the arm bracket and fixed the bracket as previous for the protection due to electrocution. (colour of pipe is decide by engineer -in -charge or his representative. |
| 24 | Supplying installation, testing, erection & commissioning of outdoor feeder pillar depth not less than 350 mm, fabricated with 2 mm thick CRCA sheet suitable for 415/ 500 volts 50 Hz A.C. supply with CRCA sheet on bottom for taking load of cable gland necessary individual gland plates for cable gland, cable alley, MS angle iron frame 35mm x 35 mm x 5 mm, locking arrangements as per direction of engineer in charg complete with bus bar chamber having 250 Amp TPN Al busbar duly sleeved and Numbering, i/c supplying and fixing the following mounting inside the panel - interconnections with suitable size Al. bus bar/copper cable for suitable size for following outgoing and incoming MCCB’s, earthing studs, powder coating/ stove enamelled painting after 7 tank treatment process with following accessories as reqd (not less then 1.92 Sq.Mtr)Incoming250A 4P MCCB 36KA WITH SPREADER LINK - 1 Nos 95A FP POWER CONTACTOR - 2 Nos.CORONO TIMER- 2 Nos.METERING DIGITAL SINGLE PHASE AMMETER- 1 No.DIGITAL SINGLE PHASE VOLTMETER - 1 No.R,Y,B INDICATION LAMP- 3 Nos.6A SP MCB 10KA FOR CONTROLLING- 3 Nos.CT 250/5A CLASS-1 - 3 Nos.ASS+VSS SELECTOR SWITCH - 1 No.OUTGOING100A FP MCCB 36KA WITH SPRAEDER LINK- 3 Nos |
| 25 | Credit for old Dismantling materials |
| 26 | Assorted Fitting Flood/street light |
| 27 | Assorted XLPE cable Aluminium conductor |
| 28 | Arm bracket GI Please Enable Macros to View BoQ information |