| 1 | Excavation in soft / loose soil not exceeding 1.5 mtr wide and n exc 1.5 mtr depth and getting out incl forming of bottom for laying cable all as specified and directed |
| 2 | Excavation in hard / dense soil including road cutting etc not exceeding 1.5 mtr wide and n exc 1.5 mtr depth and getting out incl forming of bottom for laying cable all as specified and directed |
| 3 | Returning filling using excavated soil including spreading levelling, watering and well ramming in layers n exc 25 cms all as specified and directed |
| 4 | Removal of surplus excavated material n.exc 50 mtrs and depositing where directed at a level n.exc 1.5 mtrs above the starting point all as specified and directed |
| 5 | Supply & fix in replacement MCCB, 415 volts, 4 pole adjustable thermal setting type 25 KA, 63A as per existing make and model suitable or equivalent make as per list of make at PS complete all as specified and directed. |
| 6 | Supply and fix LED antique decorative post top lantern, E27 holder with lamp 40 Watt capacity for energy efficient conservation upto 50% and with eco friendly lighting system with all accessories and necessary connection complete all as specified and as directed. |
| 7 | Supply & Fix in replacement MCB SP 5 to 32 Amps, 440V, 10KA 'C' Curve as per existing make and model or suitable equivalent make as per list of make at PS complete all as specified and directed. |
| 8 | M&L for fixing in replacement straight through jointing kits heat shrinkable type LT UG XLPE cable heavy duty armoured sheathed and making the disturbed surface after relaying the cable and making joints suitalbe for aluminium conductor of 16 to 25 Sqmm 3.5 core complete all as specified and directed.Note : Taking up cable, excavation, returning filling and removal of surplus soil upto 1 cum meter shall be included in the qouted rate. More than 1 cum shall be measured and paid separately under relevant items of this schedule. |
| 9 | M&L for fixing in replacement straight through jointing kits heat shrinkable type LT UG XLPE cable heavy duty armoured sheathed and making the disturbed surface after relaying the cable and making joints suitalbe for aluminium conductor of 35 to 70 Sqmm 3.5 core complete all as specified and directed.Note : Taking up cable, excavation, returning filling and removal of surplus soil upto 1 cum meter shall be included in the qouted rate. More than 1 cum shall be measured and paid separately under relevant items of this schedule. |
| 10 | Supplying and laying in replacement of GI tubing light grade for cable protection in trenches/duct/fixing to pole/wall or in such similar position of 80 mm dia all as specified and directed:-Note : Excavation, returning filling and removal of surplus soil shall be measured and paid separately under relevant items of this schedule |
| 11 | Supplying and laying in replacement of GI tubing light grade for cable protection in trenches/duct/fixing to pole/wall or in such similar position of 50 mm dia all as specified and directed:-Note : Excavation, returning filling and removal of surplus soil shall be measured and paid separately under relevant items of this schedule |
| 12 | Taking up old unserviciable LT UG cables/DWC from trench/poles/wall etc of 10 Sqmm 4 Core complete all as specified and directed.Note : Excavation, returning filling and removal of surplus soil shall be measured and paid separately under relevant item of this schedule |
| 13 | Taking up old unserviciable LT UG cables/DWC from trench/poles/wall etc of 16 Sqmm 4 core complete all as specified and directed.Note : Excavation, returning filling and removal of surplus soil shall be measured and paid separately under relevant item of this schedule |
| 14 | Taking up old unserviciable LT UG cables/DWC from trench/poles/wall etc of 25 Sqmm 3.5 core complete all as specified and directed.Note : Excavation, returning filling and removal of surplus soil shall be measured and paid separately under relevant item of this schedule |
| 15 | Taking up old unserviciable LT UG cables/DWC from trench/poles/wall etc of 35 Sqmm 3.5 core complete all as specified and directed.Note : Excavation, returning filling and removal of surplus soil shall be measured and paid separately under relevant item of this schedule |
| 16 | Taking up old unserviciable LT UG cables/DWC from trench/poles/wall etc of 50 Sqmm 3.5 core complete all as specified and directed.Note : Excavation, returning filling and removal of surplus soil shall be measured and paid separately under relevant item of this schedule |
| 17 | Supply and laying LT UG cable XLPE insulated armoured and PVC sheathed 1100 volts grade with aluminium conductor of 10 Sqmm 4 core all as specified and directed. |
| 18 | Supply and laying LT UG cable XLPE insulated armoured and PVC sheathed 1100 volts grade with aluminium conductor of 16 Sqmm 4 core all as specified and directed. |
| 19 | Supply and laying LT UG cable XLPE insulated armoured and PVC sheathed 1100 volts grade with aluminium conductor of 25 Sqmm 3.5 core all as specified and directed. |
| 20 | Supply and laying LT UG cable XLPE insulated armoured and PVC sheathed 1100 volts grade with aluminium conductor of 35 Sqmm 3.5 core all as specified and directed. |
| 21 | Supply and laying LT UG cable XLPE insulated armoured and PVC sheathed 1100 volts grade with aluminium conductor of 50 Sqmm 3.5 core all as specified and directed. |
| 22 | Supply & laying in replacement DWC (Double Wall Corrugated) HDPE pipe ISI marked of outer dia of 50 mm and inner dia 38 mm polethylene including couplers, bends, cap etc., with smooth internal and profiled external surface for non pressure under ground cable complete all as secified and directed |
| 23 | Supply & laying in replacement DWC (Double Wall Corrugated) HDPE pipe ISI marked of outer dia of 63 mm and inner dia 50 mm polethylene including couplers, bends, cap etc., with smooth internal and profiled external surface for non pressure under ground cable complete all as secified and directed |
| 24 | Material and labour for earthing with galvanised earth plate electrode 600 mm x 600 mm x 6 mm thick, burried directly in ground vertically to a depth of not less than 2.25 mtr below ground level connected to galvanised iron strip 32 mm x 6 mm by means of GI Welding made out of galvanised iron mild steel and 40 mm dia GI pipe \\"light grade\\" for protection of earth lead, 20 mm dia GI pipe for watering and earth plate surrounded by packed layer of coal and common salt, 15cm thick all around bottom and top, watering pipe of 20 mm bore of light grade with funnel all as shown in electrical plate No 3 of SSR Part-I (2009) and connecting to earthing test point, main switch board, transformer neutral and testing on completion as directed including earthing pit in PCC (1:3:6) type C-1, pre-cast reinforced cover with MS XPM Jalli, RCC 1:1.5:3 cover slab of size 400 x 400 x 100 mm with one handle made out of 8 mm dia round bar, wire mesh and testing complete all as specified and as directed including dismantling old defective earth pit.Note: (i) Cost of GI earth Strip and GI protection pipe upto 7.5mtr length shall be deemed to be included in the rate quoted for this item.(ii) The unit rate shall also includes for Wire mesh, funnel, excavation.returninng & filling. PCC chamber pit,RCC cover & test point.(iii) If the desired earth resistance is not achived during testing as per IS the complete earthing shall be carried out by the contractor at his own cost and no extra claim shall be admissable. |
| 25 | Supply & Fix in replacement aluminium cables lugs for cables of size upto 10 to 35 Sqmm including necessary crimping with crimping tool complete all as specified and directed |
| 26 | Supply & Fix in replacement aluminium cables lugs for cables of size upto 50-70 Sqmm including necessary crimping with crimping tool complete all as specified and directed |
| 27 | M & L for repair of LT Panel board outdoor type repair/replace damaged door hinges set of three nos front and back side and legs 40x40x6mm MS angle and necessary cutting, welding & drilling hole etc.works required at site complete all as specified and directed |
| 28 | M&L for providing cement concrete Type D2 1:4:8 using 40mm graded stone aggregate in foundation filling and mass concrete for foundation for pole etc all as specified and directed. |
| 29 | M&L for providing cement concrete Type C1 1:3:6 using 20mm graded stone aggregate in foundation filling and mass concrete for coping of pole etc all as specified and directed. |
| 30 | M&L for providing cement concrete Type B1 1:2:4 using 20mm graded stone aggregate in foundation filling and mass concrete for coping of pole etc all as specified and directed. |
| 31 | M & L for painting steel tubular poles 9/11 Mtr long including cross arms etc. with one coat of aluminium paint including preparation of surfaces name and pole number on the pole complete all as specified and directed by Engr-in-Charge |
| 32 | M & L for painting RCC poles 9/11 Mtr long including cross arms etc. with one coat of white paint including preparation of surfaces and writing pole number on the pole complete all as specified and directed by Engr-in-Charge |
| 33 | M & L for painting to feeder pillar box / LT panel & duct cover etc, including angle iron frame with two coats of grey or colour writing feeder name as approved by GE / Engr in -Charge as per site suitability synthetic enamel paint including door welding with hinges complete as specified and directed |
| 34 | Maintenance and removal of vegetation,grass cutting,trimming of brances for proper illumination, clearnces of the existing poles, panels area including removal of accumulated debris depositing complete all as specified and as directed by Engr-in-Charge. |
| 35 | Taking down and dismantling of existing pole mounted luminaires of any types (Garden lights,high mast light,Flood lights,Gate lights,Street lights,Decorative lights,Solar lights,post top lanten) including disconnection and cleaning corrosion to all spares (bolts,clamps,brackests) with preventing to rapid rusting treatment.replace a LED drivers for maintaining to IP 66 rating integrity,external surge protection devices for over- voltage protection. and suitable size of LED module board, terminal blocks, flexible wires,UV stabilized covers for specific luminaire models etc complete all as specified and as directed by Engr-in-Charge. |
| 36 | Supply & Fix in replacement LED driver 12 to 20 Watt for street light/flood light/high bay light all as specified and directed. |
| 37 | Supply & Fix in replacement LED driver 25 to 40 Watt for street light/flood light/high bay light all as specified and directed. |
| 38 | Supply & Fix in replacement LED driver 45 to 75 Watt for street light/flood light/high bay light all as specified and directed. |
| 39 | Supply & Fix in replacement LED driver 100 to 150 Watt for street light/flood light/high bay light all as specified and directed. |
| 40 | S&F in replacement GI bracket for fixing street/ security light fitting made out of GI pipe medium grade 40 mm dia 1.50 Mtr long bent to required angle/ shape complete with MS flat iron clamp of size 50x5 mm, nut, bolt, washer of suitable size as per site requirement etc and fixed in pole/wall including two coats of aiuminium paint over a coat of red oxide primer to MS clamps , nut ,bolts etc complete all as specified and directed |
| 41 | S&F in replacement GI bracket for fixing street/ security light fitting made out of GI pipe medium grade 25 mm dia 1.50 Mtr long bent to required angle/ shape complete with MS flat iron clamp of size 25x5 mm, nut, bolt, washer of suitable size as per site requirement etc and fixed in pole/wall including two coats of aluminium paint over a coat of red oxide primer to MS clamps , nut ,bolts etc complete all as specified and directed |
| 42 | M&L for taking down unserviceable / damaged steel tubular pole / RCC pole for street light of any type/size all as specified and directedNote : Excavation/earth work etc shall be measured and paid for separately under relevant item of this Schedule |
| 43 | S&F Steel tubular swaged Poles complete with cast iron base plate, finial taper plug,bolts,nuts & screws as specified type SP-31 (9.0 Mtrs long) with single curve at the top for fixing of street light fitting all as specified and directed |
| 44 | Supply & Fixing HDGI Hexogonal/Octagonal pole 07 meter having top dia 70mm and bottom dia 135mm and thickness 3mm,including GI heavy duty light mounting bracket with nuts & bolts 4 Nos \\"J\\" type foundation bolts of dia 16mm and 450mm long with 03 base plate of size 220mmx220mmx12mm Poles complete with 45 degree single curve swan neck type at the top for fixing of street light fitting all as specified and as directed by Engr-in-Charge. Note : Earth works excavation, returning filling, removal of surplus soil and PCC foundation shall be measured and paid under relevant of this items complete all as specified and as directed by Engr-in-Charge. |
| 45 | S&F in replacement of FRP boxes with 4 connectors heavy duty, and clamps made out of GI nuts, bolts , busbar chamber size 30x20 cm including provn of Aluminium Busbar SPN 30 Amps capacity fixed on porcelain insulator, 01 No MCB SP 6 Amps Capacity complete all as specified and directed by Engr-in-Charge. |
| 46 | Sup & Fixing Astronomical timer switch for security light, to be fixed on existing LT panel, range 6W to 12W confirming to IS/IEC 60947-1 provided with protection degree IP 54, Extrended with brand coil, with FRLS internal wiring, inbuild short circuit protection,Class H insulation all as specified and as directed at site by Engr-in-Charge. (Make - Havells) |
| 47 | Sup & Fixing in replacement stainless steel under water nozel mounted fountain LED light,RGB multicolour colour changing with controller warm white 27W, 240V, 50 Hz, IP -68, water proof with nuts bolts and washer to be fixed on floor with all connect items as required for installation all as specified and directed at site by Engr-in-Charge. |
| 48 | Sup & Fixing in replacement of Street light fitting LED type,warm white light 45 Watts 240 Volts lumen efficiency not less than 100 lm/Watt and accessories complete, mounted on 25 mm dia light grade GI pipe bracket 1.0 mtr long bent to shape, mounted on wall,connection complete all as specified and directed by Engr-in-Charge. |
| 49 | S&F in replacement of Street light fitting LED type, warm white light 72 Watts 240 Volts high luminous , energy efficiency not less than 100 lm/Watt , including SPD fitting before placing the street light and accessories complete mounted on light grade GI pipe bracket 1.0 mtr long bent to shape, mounted on wall,connection complete all as specified and directed by Engr-in-Charge. |
| 50 | Sup & Fixing in replacement of Street light fitting LED type,warm white light 90 Watts 240 Volts high luminous , energy efficiency not less than 100 lm / Watt , including SPD fitting before placing the street light and accessories complete mounted on light grade GI pipe bracket 1.0 mtr long bent to shape, mounted on wall,connection complete all as specified anddirected by Engr in Charge. |
| 51 | Sup & Fixing in replacement of warm white light Flood light fitting LED type, 120 Watts 240 Volts lumen efficiency not less than 100 lm/Watt , PDC housing with IP 65 flood light opties , efficient housing output LED sleek and robust design for better aesthetics , highly efficient reliable and sturdy, mounted on wall,connection complete all as specified and directed by Egineer-in-Charge |
| 52 | Sup & Fixing in replacement of warm white light Flood light fitting LED type, 150 Watts 240 Volts lumen efficiency not less than 100 lm/Watt , PDC housing with IP 65 flood light opties , efficient housing output LED sleek and robust design for better aesthetics , highly efficient reliable and sturdy, mounted on wall,connection complete all as specified and directed by Egineer-in-Charge |
| 53 | Sup & Fixing in replacement energy efficient post top light fitting on wall/gate 360 degree indirect light with IP 65 protection high quality integrated LEDs assuring soothing warm white light all night long LED 40 W black case aluminuim, including all necessary wiring , clamps, nut and bolts mounting accessories etc all as specified and directed by Engr in Charge. |
| 54 | Sup & Fixing in replacement energy efficient bollard light 360 degree light distribution with IP-65 fitting on ground, wall etc including excavation and PCC 300cmx300cm as required and high quality integrated LEDs assuring soothing warm white light all night long LED 10 W black case aluminuim including all necessary wiring , clamps, nut and bolts mounting accessories etc all as specified and directed by Engr in Charge |
| 55 | Sup & Fixing in replacement of high Mast warm white light 150 W 220V 50 Hz innovatirely designed hear sink for superior thermal management high efficiency round highbay in PDC housing, luminaire upto 130Lm/W ,IP-66 complete all as specified and directed by Engr in Charge |
| 56 | Sup & Fixing in replacement of water proof LED strip Tri- colours for decorative illumination, with power adopter. The cost is inclusive of adhesive required for fixing all as specified and as directed by Engr in Charge |
| 57 | Sup & Fixing in replacement of warm white LED antique decorative post top lantern, E27 holder with lamp 40 Watt capacity for energy efficient conservation upto 50% and with eco friendly lighting system with all accessories and necessary connection complete all as specified and as directed by Engr in Charge. |
| 58 | Sup & Fixing in replacement of warm white LED decorative post top lantern, with lamp 40 Watt capacity 240 volt ,50Hz with SPD for energy efficient conservation eco friendly lighting system with all accessories and necessary connection complete all as specified and as directed by Engr in Charge. Please Enable Macros to View BoQ information |