| 1 | M&L for 15mm thick rendering in cement mortar 1:6 on brick/cocrete surfaces, fair faces of walls finishing the surfaces even and smooth without using extra cement compete including taking down old cement plaster and all debries removing the outside of MOD land upto distance exc 1km to 5km all as specified and directed. |
| 2 | M&L for rendering 15mm thick in cement mortar 1:3 in two layers, mixed with Liquid WPC by weight of cement as per manufactures instruction, as in chajjas upto 12 Mtr height including necessary scaffolding etc complete including taking down old cement plaster and all debries removing the outside of MOD land upto distance exc 1km to 5km all as specified and as directed. (Note :- LWPC shall be measured and paid separately). |
| 3 | M&L for rendering 15mm thick in cement mortar (1:4) in two layers on other than fair faces of brick/concrete walls mixed with Liquid WPC by weight of cement as per manufactures instruction, finishing the surfaces even and smooth without using extra cement upto 30 Mtr height complete all as specified including taking down old cement plaster and all debries removing the outside of MOD land upto distance exc 1km to 5km directed.(Note :- LWPC shall be measured and paid separately). |
| 4 | Supply only Liquid WPC complete all as specified. |
| 5 | M&L for preparation of new plastered/concrete surfaces of walls applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces. |
| 6 | M&L for preparation of new plastered/concrete surfaces of walls and applying two coats of oil bound distemper over one coat of primer, over 1mm thick plaster of paris putty ( where as required ) white or tinted upto 30 Mtr height including necessary scaffolding etc complete all as specified and directed. |
| 7 | M&L for preparation of old wood or wood based surfaces over 10cm width or girth, not otherwise described and applying one coat of synthetic enamel paint, complete all as specified and directed. |
| 8 | M&L for preparation of old steel or iron surfaces over 10cm width or girth, not otherwise described and applying one coat of synthetic enamel paint upto 30 Mtr height , including provision of scafloding complete all as specified. |
| 9 | M & L for Preparation of old distempered surface including by brooming down with steel wire brushing, scrapping down smoke soot, moulds, moss and efflorescent salts, trading oil, greasy spots and applying one coat of oil bound distemper on wall any colour or tinted including 1mm thick birla white putty over a coat of primer ( where as required ) upto 30 Mtr height including necessary scaffolding etc complete all as specified and as directed. |
| 10 | M & L for complete removal of exiting/new suface treatment and provide two coat of oil bound distamper over a coat of primer on wall over prepared surface finished with and including 1 mm thick plaster of paris putty and rubbing with sand paper upto 30 Mtr height including necessary scaffolding etc complete all as specified and as direct. |
| 11 | M&L for preparation of old plastered /concrete surfaces of ceiling and applying one coat of oil bound distemper, white or tinted upto 30 Mtr height including necessary scaffolding etc complete all as specified and directed. |
| 12 | M&L for preparation of old plastered/unplastered/ concrete surfaces of walls and applying one coat of plastic emulsion paint, white or tinted upto 30 Mtr height including necessary scaffolding etc complete all as specified and directed. |
| 13 | Dismantling of ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/ blankets, any thickness, including cover fillets |
| 14 | S & F Anodised aluminium snap grid frame work for false ceiling all as specified |
| 15 | S & F Hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long complete all as specified. |
| 16 | Providing and fixing 10mm thick plaster of paris ceiling (Gypsum anhydrous) to flat surface over 2nd class soft wood fillets, or metal frame work and reinforced with G.I. wire mesh (Fillets, metal frame work and G.I. wire mesh paid separately). |
| 17 | Providing & fixing false ceiling at all heights with semi perfoarated 12mm thick micro tegular edged GRG (Glass Fibre reinforced Gypsum) false ceiling tiles of Size 595 x 595 mm of approved texture, design and patterns havings moisture content less than 2%, humidity resistance of 99%, nbrc 0.50 TO 0.75 as per IS 8225 : 1987 Non combustible as per BS 476 part 4 )- 1970 and light refilectace of 85% (minimum) to be laid in ture horizontal level suspended on in terlocking metal T-Grid of hot depped galvanised iron section of 0.33mm thick (galvanized) @ 120 Grams per sqm including both sides) comprising of main-T runners of size 15x32mm of lenfth 3000 mm cross-T of size 15x32mm of length 1200mm and secondary intermediate cross T of size 15x32 mm of length 600mm to form grid module of sixe 600x600 mm suspended from ceiling using galvanised mild steel items (galvanizing @ 80 grams per sqm) i.e 50mm long,8 mm outer diameter M-6 dash fasters 6mm dia fully threaded hanger rod up to 1000 mm length and L-shape level adjuster of size 85x25x2 mm. Galvanised iron permeter wall angle of size 24x24x0.40mm of length 3000mm to be fixed on periphery wall partition with the help of palstic rawl plugs rawl plugs at 450mm centre to centre and 40mm long dry wall wood screws. the work shall be carried out as per specifications drawing and as per derictions of the Engineer - in - Charge |
| 18 | M&L for preparation of surfaces and applying one coat of exterior acrylic emulsion weather proof treatment upto 30 Mtr height including necessary scaffolding etc complete all as specified and directed.Note : The tint and shade be as approved by the GE. |
| 19 | M&Lfor complete removal of existing treatment from external surface on wall by wire brushed & stopping of surfaces & leveling/edging the disturbed places/edges using putty to obtain smooth regular/even finish using sand paper and applying two coats of exterior emulsion paint over and including one coat of primer and upto 30 Mtr height including necessary scaffolding etc complete all as specified and directed. |
| 20 | M&L for preparation of old plastered/unplastered/concrete surfaces of walls, kerbs stone & stopping of surfaces and applying one coat of exterior emulsion paintt upto 30 Mtr height including necessary scaffolding etc complete all as specified and directed.Note : Application as per SSR Pt-I clause 15.15.1 to 15.15.12 CURING : Painted surfaces shall be sprinkled with water using a fog spray two or three times a day. The curing shall be started as soon as the paint has hardened so as not to be damaged by the spray, about 12 hour after the application. |
| 21 | M & L for preparation of old Traditional Painting structure painting with water proof paint / any type of Existing paint use of various location complete all as specified and directed by Engr-in-charge. |
| 22 | M&L for preparation of old Concrete surfaces of Wall existing treatment from over 10cm width/girth and applying one coat of synthetic enamel paint (in camouflage pattern using number colours) upto 30 Mtr height including necessary scaffolding etc complete all as specified and as directed.Note : Pattern of camouflage shall be approved by GE. Please Enable Macros to View BoQ information |