| 1 | Demolition of cement concrete (un reinforced) in ground floors and paving n.exc 15cm thickness (below or above ground (level) and lowering if necessary, removal of the rubbish off the premises complete all as specified and directed. |
| 2 | Demolition of reinforced cement concrete in ground floors and pavings n.exc 15 cm thickness (below or above ground level) and removal of the rubbish off the premises complete all as specified and directed. |
| 3 | Demolition of brick work built in CM including all quions, arches, pillars etc, but excluding ashlar facings, dressed stonework and precast concrete articles including removal of the rubbish off the premises complete all as specified and directed. |
| 4 | M&L for flyash brick work with old size bricks straight curved on plan exceeding 6 meter mean radius for manholes /septic tank /soak well etc /in sewer works and drains with old size bricks in CM 1:4 complete all as specified and directed. |
| 5 | All as per item No 4.00 here-in-before but except bricks. Old size bricks obtianed from demolition shall be re-used after proper cleaning complete all as specified and directed. |
| 6 | Excavating in trenches , n.exc 1.5 m wide and n.exc 1.5 m depth for foundation etc or for shafts, wells, cesspits ,manhole pier hole, laying of cables, pipes etc n.exc 10 sqm on plan and n.exc 1.5m in depth and getting out in any kind of soilNote : Manual excavation to be done. During excavation if any damage occured to existing cable any type/ water pipe line, it will be contractor responsibilty to get it repair and make functional by providing jointing kit etc without any extra cost. Contractor has to repair it within 24 hrs so that essential service can not be effected due to such damage.If contractor fails to repair it within 24 hrs penalty @ Rs 500/- will be charged to contractor. In this GE decision will be final, conclusive and binding. |
| 7 | All as per item No 6.00 here-in-above but depth exc 1.50 m but n.exc 3.00 mtr complete all as specified and directed. |
| 8 | Excavation over area, not exc 1.5 mtr deep and gatting out in loose/soft soil complete all as specified and directed. |
| 9 | All as per item No 8.00 here-in-above but depth exc 1.50 m but n.exc 3.00 mtr complete all as specified and directed. |
| 10 | Returning, filling in incl spreading, levelling, watering and well ramming in layers not exceeding 25 cm in soft /loose soil.complete all as specified and directed. |
| 11 | Removing excavated material in soils n exc. 50 m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed. |
| 12 | M&L for PCC 1:3:6 type C-2 (40 mm graded stone aggregate) in foundation filling and mass concrete complete all as specified and directed. |
| 13 | Demolition and breaking up drain pipe (SGSW/PVC/RCC etc) set in cement mortar of internal dia of pipe 150 mm complete all as specified and directed. |
| 14 | Demolition and breaking up drain pipe (SGSW/PVC/RCC etc) set in cement mortar of internal dia of pipe 200 mm complete all as specified and directed. |
| 15 | Supplying and laying of PVC underground drainage sewer system pipe bearing 160 mm dia SN 4 including jointing with couplar, bend tee as per site requirement complete laid in trenches or floors complete all as specified and directed. |
| 16 | Supplying and laying of PVC underground drainage sewer system pipe bearing 200 mm dia SN 4 including jointing with couplar, bend tee as per site requirement complete laid in trenches or floors complete all as specified and directed. |
| 17 | Material and labour for cement concrete bed to drain pipe for 200mm bore of pipe including forming cradles in Cement concrete 1:3:6 Type C2 complete all as specifiedand and as directed. |
| 18 | Material and labour for cement concrete bed to drain pipe for 150mm bore of pipe including forming cradles in Cement concrete 1:3:6 Type C2 complete all as specifiedand and as directed. |
| 19 | Taking down cement plaster from inside/outside of existing septic tank/manholes drain and outer surface of bldgs etc incl raking out joints, hacking for key scrubbing down with water and removal rubbish off the premises complete all as specified and directed. |
| 20 | M&L 15 mm thick rendering in cement mortar 1:4 inside and outside wall of manhole, drains of brick work/concrete suface even and smooth with using extra cement complete all as specified and directed. |
| 21 | Providing, cement concrete 1:2:4 type B-0 (12.5 mm graded stone aggregate) in roof kerbs or mud stops, rounded or chamfered on edges, copings, kneelers, apex stones, bed plates, kerbs, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, as directed |
| 22 | M&L type B-1 1:2:4 (20mm graded stone aggregate) providing RCC precast cement concrete as in cover slab for man hole and similar article with plain face set in cement mortar 1:6 complete all as specified and directed. |
| 23 | M&L for mild steel TMT bar 10mm dia and over, cut to length bent to shape required including cranking bending spirally for hooping for column, hooking end binding with binding wire and including mild steel wire(annealed) not less than 0.9mm dia complete all as specified & directed by Engineer in Charge. |
| 24 | Taking down eaves gutters and rainwater/SWR pipes at walls/floors in sewer lines (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., including cleaning or refixing or removal to Store (measured overall as fixed along the centre line over fittings and accessories), complete all as spd and directed. |
| 25 | S & F for PVC (SWR) pipes of 110 mm dia single socketed in any length with rubber ring joints fixed to walls, including with clamps etc. complete all as specified and directed. |
| 26 | S & F for PVC (SWR) pipes of 75 mm dia single socketed in any length with rubber ring joints fixed to walls, including with clamps etc., complete all as specified and directed. |
| 27 | S & F in repair PVC (SWR) bends any radius of 110 mm bore with access door complete all as specified and directed. |
| 28 | S & F in repair PVC (SWR) bends any radius of 75 mm bore with access door complete all as specified and directed. |
| 29 | S & F PVC (SWR) reducers of 110 mm bore |
| 30 | S&F 75mm PVC (SWR) vent cowl. |
| 31 | S&F 110mm PVC (SWR) junction single (simgle T) equal or unequal complete all as specified |
| 32 | Dismantling floor/hearth or wall tiling including cement mortar bedding (but not backing), removing rubbish off the premises as directed. |
| 33 | M&L for coloured non skid (joint free) ceramic tiles 7 to 8 mm thick (Square /rectangular) area of each tile exceeding 0.11sqm but not exceeding 0.18 sqm, in floors etc set and jointed in neat cement slurry and including 15 mm thick screed bed in cement mortar 1:6 complete all as specified and directed. |
| 34 | M & L Glazed ceramic colour tiles in vertical surface 350x 250x 7 mm/ 450X 350X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match and including rendering 10 mm thick cement plaster in CM 1:3 on brick work or concrete surfaces of wall ccomplete all as specified and directed. |
| 35 | S & F in repairs vitreous china squatting pan, 'Orissa\\" pattern, size 580 mm X 440 mm white with ‘P’ or ‘S” trap, front or back inlet and integral foot rests, any pattern and including fixing , connector to flush pipe, lime concrete bedding and making connections to flush pipe, connector to branch pipe and anti syphonage pipes etc. including sealing the joints and making leak proof using sealant complete all as specified and as directed by Engineer-in-Charge. |
| 36 | S & F in repairs vitreous china wash down water closet (pedestal pattern), white including thermoplastic seats and covers of grade 2 type, flat with hinging device of bronze or brass with nickel chromium plating, fixing bolt, connector to flush pipe and making connections to flush pipe, connector to branch soil pipe and anti syphonage pipes etc. including sealing the joints and making leak proof using sealant complete all as specified and as directed by Engineer-in-Charge. |
| 37 | S& F in repair water closet seat cover white coloured pattern with flat bottom and cover and mild steel chromium plated or aluminium hinging devised complete all as specified and directed. |
| 38 | S & F in repair 10 litre capacity PVC low level flushing cistern with all accessories complete fixed with WC including syphone pipe, PVC flushing pipe of size complete (w/o brackets). |
| 39 | S & F in repair flush pipe of polyethylene of low or high density of PVC, 32 mm dia, for low level cistern complete all as specified and directed. |
| 40 | S & F in repair grating square 150mm size of PTMT (minimum 100 gms) complete all as specified and directed. |
| 41 | Cutting into existing manholes 150mm dia pipe for connecting new drains making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B1 smooth finished and reforming benching as required complete . |
| 42 | Cutting into existing manholes 200mm dia pipe for connecting new drains making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B1 smooth finished and reforming benching as required complete . |
| 43 | Cleaning and desilting of sewage lines upto 150mm dia and depth up to 1.50m, cleaning the lines by manual roding/mechanically jet pumps/sewage cleaning machine as per rule 5 and protective gear and safety devices as per rule 4 of the Prohibition of Employment as Manual Scavengers and their Rehabilitation Rules, 2013 and removing blockage and flushing out by means of pumping out/removing liquid waste/sewage, plugging the ends pipes or diverting the flow into drains if necessary, removing silt sludge etc, sprilinkling bleaching powder on the silt to avoid smell including all precautionery and saftey measures such as saftey belts, ligthting arrangement face mask gloves etc and removing the same (silt, sludge & other waste material) in leak proof trucks covered with tarpoline to out side of MoD land as per existing rules and regulation of civil authorities and flushing the sewage lines with fresh water complete all as specified and as directed. Unit rate quoted shall deemed to be included of cleaning of shrubs, grass small roots etc. around the Manholes, Inspection chamber etc and along sewage lines wherever required or as directed and no extra payment shall be made on this account) |
| 44 | All as per item No, 43.00 here-in-before but dia exceeding 150mm to 300mm complete all as specified and directed. |
| 45 | Cleaning of blockage of existing sewage system and plumbing system (Comprising of sewer line in CI, SGSW or SG pipes) , house connection from WC, bath, Kitchen etc including gully traps, floor/Nahani traps, CI Pipes and plumbing work etc of any description and in any position below or above ground level, located in different situations to remove of all solid or liquid wastage to make the entire system functional as directed by Eng-in-Charge Note :-(i) contractor will deploy three SDA mazdoor, daily to attend day to day complaint as mentioned above. SDA mazdoor will report daily at AGE B/R-I Subdivision at 0830 hrs and depart 1700 hrs after attending all complaints. I n case of non attending complaints in same day , recovery @ RS 250 per complaints will be recovered from contractor and in case of Non deployement od SDA Mazdoor recovery @ RS 400/y shall be made from the contractor Please Enable Macros to View BoQ information |
| 46 | Cleaning of blockage of existing sewage system and plumbing system (Comprising of sewer line in CI, SGSW or SG pipes) , house connection from WC, bath, Kitchen etc including gully traps, floor/Nahani traps, CI Pipes and plumbing work etc of any description and in any position below or above ground level, located in different situations to remove of all solid or liquid wastage to make the entire system functional as directed by Eng-in-Charge Note :-(i) contractor will deploy three SDA mazdoor, daily to attend day to day complaint as mentioned above. SDA mazdoor will report daily at AGE B/R-I Subdivision at 0830 hrs and depart 1700 hrs after attending all complaints. I n case of non attending complaints in same day , recovery @ RS 250 per complaints will be recovered from contractor and in case of Non deployement od SDA Mazdoor recovery @ RS 400/y shall be made from the contractor Please Enable Macros to View BoQ information |