| Sl. No. | Item Description |
| 1 | M&L Solid PVC Wall Lining consisting of 5mm thick Plain colour PVC sheet inclusive of solvent cement and fixing at site on PVC frame as per specifications any description, fixed in any position with nails icluding edge/end mouldings etc complete all as specified and directed by Eng-in-charge. |
| 2 | M&L 5mm thick PVC sheet fillet of width 35mm for wall paneling inclusive of fixing on to wall to make PVC Frame as per specification and drawing complete all as specified and directed by Eng-in-charge. |
| 3 | S&F aluminium three track Powder coated of any color ( thickness of powder coating not less than 50 micron) sliding window with three sliding shutter , the size of outer frame three track 92 x 31.5x 1.20mm ( using two track for glazed window shutter and one track for wire gauged ) , the section shutter size 37x 18x 1.2mm)and glazing with 4 mm thick glass ( plain/floated/tinted) including all-around suitable rubber gasket and MS wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.4mm and fixed on aluminum flat and inserted in the frame of shutter with tracking arrangement each sliding window shall be provided with one number handle including locking arrangement & 2 numbers’s sliding rollers of nylon with including all necessary fittings complete all as specified and directed by Engineer-in-Charge |
| 4 | S& f aluminium powder coating of any color ( thickness of powder coating not less than 50 micron) frame for door,window and ventilators or similar wk with one or more rebate inc joining cleat for fixing complete all as specified and directed by Engineer-in-Charge |
| 5 | S&F aluminium door shutters powder coating of any color ( thickness of powder coating not less than 50 micron), alumimnium section weighing min. 0.55 Kg/m including necessary joining cleats, glazing clips, rubbers packing, handles 2 Nos in each door, hinges, anodised aluminium snap beading, screws etc complete all as specified.directed by Engineer - in - Charge. |
| 6 | S&F aluminium window and ventilator shutters or aluminium partition, powder coating of any colour (Thickness or powder coating not less than 50 micron),fixed type without sash bar, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws etc. complete all as specified |
| 7 | S&F 12 mm prelaminated particle board, interior grade, prelaminated both sides with decorative choice laminations complete all as specified and directed by Engineer-in-Charge |
| 8 | S&F sheet glass 4 mm thick ordinary quality(plain/floated/frosted/tinted) and glazing with oil putty / wooden beads / aluminium glazing clip in square n.exc. 0.5 sqm in each pane complete all as specified & directed. |
| 9 | S&F sheet glass 4 mm thick ordinary quality (plain/floated/frosted/tinted) and glazing with oil putty / wooden beads / aluminium glazing clip in square exc. 0.5 sqm in each pane complete all as specified & directed. |
| 10 | S&F 595x595mmx4mm thick false ceiling of Non esbestos fibre cement building boards (E Board) and including supply and fixing 'Tee\\" grid frame work made of GI sheet 0.30mm thick, bottom portion painted with cellular nitro painting, consisting angle cleats of size 25mm wide 1.6mm thick with flag fixed to RCC ceiling with dash fastener or wraping the suspending wire around the existing wooden/steel purlin/rafter for suslpending grid frame work of size 600mmx600mm suspended with 02 Nos, 1.60mm dia GI wire @ 600mm C/C on main Tee and fixed to T-grid as per manufacturer direction. The section consisting of main Tee 37mm x24mmx0.60mm thick, cross runner tee 37mmx24mmx0.60mm and. Perimeter angle 24mmx24mmx0.50mm thick shall be fixed to wall with GI screw of 40mm long @ 450mm C/C along the perimeter of wall including or wall including all as per manufacturer's instruction complete all as specified and directed Engineer-in-Charge |
| 11 | Dismantling wrought iron or mild steel work of any description not otherwise provided for. |
| 12 | S&F mild steel framed work such as grills, gratings etc with ends of bars shouldered and / or riveted or forged into spiked framed guard bars barred iron doors ladders framed blasters walkways railings framework of water tanks and similar work conforming to Fe 290 Grade E-165 |
| 13 | Dismantling of floor, hearth or wall tiling or stone slab laid, bedded & pointed in any mortar including demolition of cement mortar bedding or backing coat, including removal of debries to a distance exc 1.5 km but n.exc 2 Km complete all as spd and directed. |
| 14 | M&L for Screed bed or bedding layer of mortar 15 mm thick for laying floor finishes in CM 1:6 complete all as spd and directed |
| 15 | M&L for light shade Vitrified Ceramic tiles 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors/skirting etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as spd and directed |
| 16 | M&L 15 -18mm thick granite stone slab of any type (cut, table rubbed and polished)in steps, jambs, pillars, window cills, cooking platforms and like , bedded & jointed with grey cement slurry & pointing with coloured cement using marble dust with admixture of pigment to match with marble shade; laid over complete all as spd and directed |
| 17 | Taking down chowkats with shutters(without taking off shutters from the frame exceeding 1.50 sqm each but not exceeding 4 sqm) any type, any description |
| 18 | Taking down chowkats or frame with shutters(without taking off shutters from the frame not exceeding 1.50 sqm each & removing to store all as specified. |
| 19 | S&F in repairs aluminium (die cast) body, door closer hydraulically regulated designation No. 3 , universal type , suitable for door shutters of 851 to 1000 mm in width and weight between 61 to 80 kg and fixed. |
| 20 | Excavation in trenches n.exc. 1.5m wide and n.exc 1.50 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n.exc. 10 Sqm on plan and n.exc 1.5 m in depth and getting out in getting out in hard / dense soil complete all as specified and as directed by Engineer-in-Charge. |
| 21 | All as per item No 20 above here-in-before but description not exc 1.5mtr amd not exc 3 meter complete all as specified and as directed by Engineer-in-Charge. |
| 22 | M&L for PCC (1:4:8) type D2 using 40mm graded stone aggregate in as foundation, filling & mass concrete omplete all as specified and as directed by Engineer-in-Charge. |
| 23 | M&L for formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter rough finish surface of concrete flat complete all as specified and as directed by Engineer-in-Charge. |
| 24 | M&L for formwork to sides of pillars, columns etc; rough finish surface of concrete square, rectangular or polygonal complete all as specified and as directed by Engineer-in-Charge. |
| 25 | M&L for formwork to sides and soffits of floor or roof beams, beam hunchings, girders, bressummers, lintels, cantilevers, etc. also splays between floors and beams, etc. rough finish surface of concrete flat complete all as specified and as directed by Engineer-in-Charge. |
| 26 | M&L for formwork to chajjas, troughts and similar items including edges rough finish surface of concrete flat complete all as specified and as directed by Engineer-in-Charge. |
| 27 | M&L for formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work not exc 200 mm thick (horizontal or sloping) rough finish surface of concrete flat complete all as specified and as directed by Engineer-in-Charge. |
| 28 | M&L for fromwork to edges of concrete flats, treads breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n.exc 20cm wide and sides of RCC/PCC bands in walls, horizontal or sloping and similar work exc 10 cm but n.exc 20 cm wide, rough finished surfaces of concrete complete all as specified and as directed by Engineer-in-Charge. |
| 29 | M&L for TMT bars 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed by Engineer-in-Charge. |
| 30 | All as per item No 29 above here-in-before but 5mm dia and over upto and including 10mm dia as in stirrups, spaces & binders complete all as specified and as directed by Engineer-in-Charge. |
| 31 | M&L for reinforced cement concrete (design mix) M-25 using 20mm graded stone aggregrate in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, pillers etc complete all as specified and as directed by Engineer-in-Charge.Note : Reinforcement shall be measured and paid seperately under respective item of BoQ. |
| 32 | M&L for reinforced cement concrete (design mix) M-25 using 20mm graded stone aggregrate in columns, pillers complete all as specified and as directed by Engineer-in-Charge.Note : Reinforcement shall be measured and paid seperately undr respective item of BoQ.. |
| 33 | M&L for reinforced cement concrete (design mix) M-25 using 20mm graded stone aggregrate in beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and as directed by Engineer-in-Charge.Note : Reinforcement shall be measured and paid seperately undr respective item of BoQ. |
| 34 | M&L for reinforced cement concrete (design mix) M-25 using 20mm graded stone aggregrate in Chajjas; complete all as specified and as directed by Engineer-in-Charge..Note : Reinforcement shall be measured and paid seperately under respectively item of BoQ. |
| 35 | M&L for reinforced cement concrete (design mix) M-25 using 20mm graded stone aggregrate in slabs supported on walls, beams and columns in floors, roofs, Stair case, landings, balconies, canopies, deck slabs and in shelves and the like; complete all as specified and as directed by Engineer-in-Charge..Note : Reinforcement shall be measured and paid seperately under respective item of BoQ. |
| 36 | M&L for brick work with fly ash bricks, of old size bricks, straight or curved exc. 6 m mean radius built in CM (1:6) complete all as specified and as directed by Engineer-in-Charge. |
| 37 | Returning, filling in, including spreading levelling including watering & well ramming in layers n. exc 25 cm all in soil complete all as specified and as directed by Engineer-in-Charge. |
| 38 | Removing excavated materials n.exc 50 m and depositing where directed at a level n.exc 1.5 m above the starting point complete all as specified and as directed by Engineer-in-Charge. |
| 39 | M&L for Anti termite treatment the top surface of filled earth @ 5 litres emulsion per square metre of surface complete all as specified and as directed by Engineer-in-Charge. |
| 40 | M&L for Anti termite treatment the soil under plinth protection @5 litres of emulsion per square metre of surface area complete all as specified and as directed by Engineer-in-Charge. |
| 41 | M&L for hardcore of gauge n exc. 63mm, deposited, spread and levelled in layers n exc.15cm thick,watered and rammed to a true surface in broken stone or boulders complete all as specified and as directed by Engineer-in-Charge. |
| 42 | M&L for 75 mm thick PCC (1:3:6) type C-1 using 20 mm graded crushed stone aggregate as in plinth protection finished even and smooth without using extra cement with & including 10 mm wide, 30 mm deep joints at the rate of 3.00 mtr centre to centre and at every turning & filling the joints with bitumen & sand mixture complete all as specified and as directed by Engineer-in-Charge. |
| 43 | M&L for 100 mm thick PCC (1:4:8) type D2 using 40mm graded stone aggregate as in sub base below floors complete all as specified and as directed by Engineer-in-Charge. |
| 44 | M&L for 25 mm thick PCC (1:2:4) type B-0 using 12.5 mm graded stone aggregate as in floor or laid under floor etc complete all as specified and as directed by Engineer-in-Charge. |
| 45 | M & L for Double charged Coloured Virified Ceramic tiles 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm in floors/skirting etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match and including 15mm thick cement and sand screed (1:6) or 10mm thick rendering in CM 1:4 as required complete all as specified and directed by Engineer - in - Charge. |
| 46 | S&F glazed ceramic coloured tiles joint free 350x250x7mm/450x300x7mm square or rectanguler as on walls etc set and jointed in neat cement slurry and pointed in white or coloured cement to match over 10mm thick rendering in CM 1:4 complete all as specified and directed by Engineer - in - Charge. |
| 47 | M & L for rendering 15 mm thick on brick work or concrete surface in CM 1:6 finishing even and smooth without using extra cement, all as specified and directed by Engr- in- charge. |
| 48 | M & L for rendering 10 mm thick on brick work or concrete surface in CM 1:3 finishing even and smooth without using extra cement, all as specified and directed by Engr- in- charge. |
| 49 | M & L Preparation of newly plastered surfaces by applying two coats of interior grade wall putty and making it smooth with sand paper then applying two coats of Acrylic distemper over one coat of cement primer including all as specified by mechanical method i.e. spray gun all as specified and directed by Engineer-in-charge. |
| 50 | M & L for rendering 15 mm thick on brick work or concrete surface in CM 1:4 finishing even and smooth without using extra cement, all as specified and directed by Engr- in- charge. |
| 51 | Material & Labour for Preparation of newly plastered surfaces and applying Two coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance,dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces over and after Applying Wall care putty in two coats on wall surface and smoothening the surfcae with sand papers prepatory to paint all as directed and specified. |
| 52 | S&F aluminium door shutters powder coating of any color ( thickness of powder coating not less than 50 micron), alumimnium section weighing min. 0.55 Kg/m including necessary joining cleats, glazing clips, rubbers packing, handles 2 Nos in each door, hinges, anodised aluminium snap beading, screws etc complete all as specified.directed by Engineer - in - Charge. |
| 53 | S&F aluminium window powder coating of any color ( thickness of powder coating not less than 50 micron)and ventilator shutters, side hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 no.). hinges type B-21 100mm long (2 no.) suitable handle (1 no.) in repair complete all as specified |
| 54 | S&F Toughened glass 12 mm thick ordinary quality (plain/floated/frosted/tinted) and glazing with aluminium glazing clip in square exc. 0.5 sqm in each pane including all necessary assosories for fixing in Aluminium frame complete all as specified & directed. |
| 55 | Demolition of Cement concrete (unreinforced) in ground floors and pavings n exc 15 cm thickness (below or above ground level) |
| 56 | S&F Anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engineer in-charge |
| 57 | Surface dressing n exc 15 cm deep in hard/dence soil complete all as directed by Engr-in-Charge. |
| 58 | Preparation of new plastered surfaces and applying acrylic wall care putty in internal/external walls/RCC surfaces/soffits of chajjas/roof projections/cantilevers/balcony/ceilings etc (thickness vary from 1.5 to 2.5 mm as required for desired smoothness and levelling of surfaces in two or more layers) by using ready made wall care putty including sand papering after filling the putty to make surface smooth and ready for receiving interior/exterior painting complete all as specified and directed.Make of wall Putty : JK wall Putty / Birla Wall care Putty / Bison Wall Putty.Notes : (i) The prepared surface after wall putty, the contractor will inform to the GE as well as to the Engineer-in-Charge for site inspection before applying further external finishes. Please note that the further external finishes work will start only after approval of the prepared surface from the GE as well as to the Engineer-in-Charge through site order. |
| 59 | M&L for Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer's specification. Two or more coats after preparation to the new plastered surfaces complete all as specified and as directed by Engineer-in-charge |
| 60 | Material & Labour for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces complete all as specified and as directed by Engineer-in-charge |
| 61 | M&L Hardcore of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface with broken bricks |
| 62 | M&L for PCC 1:3:6 Type C-2 (40 mm graded aggregate ) 100 mm thick as in sub base complete all as specified and directed by Engineer-in-Charge. |
| 63 | M&L for 40mm thk Damp proof course in cement concrete 1:2:4, type B-0 to horizontal or vertical surfaces including necessary formwork ncluding mixing only liquid water proofing compound as per manufacture instruction complete all as specified and directed Note WPC will be measured & paid separately. |
| 64 | Supply only integral water proofing chemical @ 200ml/Bag of cement complete all as specified and directed. |
| 65 | M&L for Applying evenly a coat of blown type bitumen at the rate of 1.50 kg per square metre and blinding with clean dry sand @ 0.05 cu. m. per sq. m |
| 66 | M&L for Polythene film, 50 micron thick, laid on a coat of bitumen primer, @ 0.30 to 0.50 kg per sq. m |
| 67 | M&L for Reinforcement cement concrete type B1 1:2:4 using 20mm aggregate as in chhaja, Band, beam, cantilever, lintel and similar wks etc incl necessary formwork/moulding complete all as specified and directed by Engineer-in-Charge |
| 68 | M&L Reinforcement cement concrete type B1 1:2:4 using 20mm aggregate as in slab supported on walls beams and columns in floor, roof, landing and in shelves and similar wks incl necessary formwork/moulding complete all as specified and directed by Engineer-in-Charge |
| 69 | S&F TMT bars 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less then 0.9 mm dia or securing with clips complete all as specified and directed. |
| 70 | Ditto- all as per srl item no above but 6 to 8 mm dia. Bar for stirrups |
| 71 | M&L Rendering 10mm thick in CM 1:4 on on stone masonry surfaces or surface other than fair face of brick-work or on one side of lathing for skirting/dado etc complete all as spd and directed |
| 72 | M&L for Glazed ceramic tiles in vertical surface 350x 250x 7 mm/ 450X 300X 7 mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match complete all as spd and directed |
| 73 | M&L for Non skid, coloured ceramic tiles 7 to 8 mm thick (Square / rectangular) polished area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm as in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as spd and directed |
| 74 | Supply & fixing of 20mm outer dia CPVC pipes SDR 11 including all fittings Plain/brass threaded CPVC SDR 11 fittings (like Elbow, Tee, Socket, Reducer, Union, Bushing, Step over bends, End cap, End Plugs, one side brass/two side brass etc) fixed along walls, ceiling or laying under floors etc and including CPVC solvent cement for jointing complete all as specified and as directed. |
| 75 | Supply & fixing of 25mm outer dia CPVC pipes SDR 11 including all fittings Plain/brass threaded CPVC SDR 11 fittings (like Elbow, Tee, Socket, Reducer, Union, Bushing, Step over bends, End cap, End Plugs, one side brass/two side brass etc) fixed along walls, ceiling or laying under floors etc and including CPVC solvent cement for jointing complete all as specified and as directed. |
| 76 | S&F 15mm size angular Stop valves, cast copper alloy, CP,screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as spd and directed |
| 77 | S&F 15mm dia size Bib tap cast copper alloy, CP fancy type with capstan head, screwd down , screwed for iron pipes complete |
| 78 | S&F i 15 mm bore, swan neck, taps cast copper alloy capaston head CP, screwed down high pressure with or without lettered “ HOT” or “ COLD” with long screwed shanks and fly nuts screwed for iron pipes fixed complete all as spd and directed |
| 79 | S&F two way angle valve brass chromium plated, fancy type complete all as specified and as directed. |
| 80 | S&F Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete all as spd and directed |
| 81 | S&F Vitreous China Urinal, Half stall type, white (excluding flushing cistern,), complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; flush/waste pipe, and Union for discharge pipe. |
| 82 | S&F Urinal spreader of PTMT any colour for fixing with 15 mm dia pipe. Minimum weight 60gms) |
| 83 | S&F vitreous china wash down water closet pan (pedestal pattern) white with CI 'P' or 'S' trap incl water closet seat cover of plastic,jet etc.complete incl necessary PVC waste pipe fitting, complete all as specified and directed by Engineer-in-Charge |
| 84 | S&F 10 Litre capacity PVC symphonic action type flushing cistern, duel flush type (ISI Marked) low level with inlet ball valve, float and handle & PVC flush pipe, fixed in position and connecting complete. |
| 85 | S & F vitreous China squatting pan of Orrissa pattern of approved make of size 580 mm X 440 mm white with integral foot rests (excluding flushing cistern and flush pipe) including connection to trap and to flushing pipe incl lime concrete bedding and connection to antisyphonage pipe etc including making good to floor complete all as specified and directed by Engineer-in-Charge |
| 86 | S&F PVC connection 15 mm size with PTMT nuts of length 450 mm complete all as spd and directed |
| 87 | S&F chromium plated soap tray any type and fixed to plugs on wall with chromium plated brass screws complete all as specified and directed by Engineer-in-Charge |
| 88 | S&F looking mirror of size 600 x 450 mm, selected quality 5 mm thick including aluminium frame, mounted on 6 mm thick commercial plywood and fixed to wall with wooden plug & chromium plated brass screws complete all as spd and directed |
| 89 | S & F Tubular towel rail, 20mm dia, D type, 600mm long between flanges chromium plated complete all as spd and directed |
| 90 | S&F Towel Ring of CP fixed with and including chromium plated brass screws and wooden/ plastic cleats etc complete all as specified and directed by Engineer-in-Charge |
| 91 | S&F vitreous china wash basin, white, flat back, size 550 mm x 400 mm fixed on and including cast iron cantilever bracket 32 mm dia brass waste coupling and including waste fitting and union complete all as specified and directed by Engineer-in-Charge |
| 92 | S&F PVC (SWR) pipes 75mm dia single socketed in any length with rubber ring joints fixed on walls including clamp complete all as specified and directed |
| 93 | S&F PVC (SWR) pipes 75mm dia single socketed in any length with rubber ring joints laid in trenches or in floors complete all as specified and directed |
| 94 | S & F 75 mm bore of pipe PVC (SWR) bends of any radius fixed to PVC pipes complete all as specified and directed by Engineer-in-Charge |
| 95 | S & F 75 mm bore of pipe PVC (SWR) bends of any radius fixed to PVC pipes provided with access door complete all as specified and directed by Engineer-in-Charge |
| 96 | S&F PVC (SWR) pipes 110mm dia single socketed in any length with rubber ring joints fixed on walls including clamp complete all as specified and directed |
| 97 | S&F PVC (SWR) pipes 110mm dia single socketed in any length with rubber ring joints laid in trenches or in floors complete all as specified and directed |
| 98 | S & F 110 mm bore of pipe PVC (SWR) bends of any radius / shoe fixed to PVC pipes complete all as specified and directed by Engineer-in-Charge |
| 99 | S & F 110 mm bore of pipe PVC (SWR) bends of any radius / shoe fixed to PVC pipes provided with access door complete all as specified and directed by Engineer-in-Charge |
| 100 | M&L for 75 mm dia of PVC (SWR) floor trap plain with grating incluing jointing with solvent cement complete all as specified and directed by Engineer-in-Charge |
| 101 | S & F PVC(SWR) Vent cowls 110mm bore all as specified and directed by Engineer - in - Charge. |
| 102 | S & F 3 mm thick Figured glass ordinary quality and glazing with oil putty/ wooden beads / aluminium glazing in square not exceeding 0.50 sqm in each pane all as specified . |
| 103 | S & F galvanised mild steel wire cloth 0.56 mm nominal dia of wire and average width of aparture 1.18 mm and fixed with tinned tacks ro galvanised wire stapple complete all as specified and directed by Engineer-in-Charge |
| 104 | S&F MS louvers of 80 mm wide & 4 mm thick frosted glass including aluminium louver patti for adjusting the louvers fixed in Aluminium ventilators with screws etc complete all as specified and directed by Engineer-in-Charge |
| 105 | S&F Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/ Chowkhat of size 45 x 70 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives(maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules ofelasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof,water/ moisture proof and fire retardant and fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge. (M.S. hold fast/ lugs or SS dash fasteners shall be paid for separately). → Note: For WPC solid door/window frames, minus 5mm tolerance in dimension i.e. depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made all as specified and directed . |
| 106 | Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid decorative type flush door shutter of size 30mm thick comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant. WPC to be laminated with PVC foil of minimum 14 microns thick of approved design pasted with hot melt adhesive on both faces of shutter and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer- In- Charge including supply and fixing following items : (a) Stainless Steel (304 Grade) Finished Butt Hinges 100mm - 4 nos. per leaf (b) Stainless Steel (304 Grade) Finished Square Tower Bolt 150 mm long - 2 nos per leaf (c) Stainless Steel (304 Grade) Finished Handles 150 mm - 2 nos. per leaf |
| 107 | S&F 500 ltrs capacity double layer, rotational molded, polythene water storage tank (Cylindrical vertical with closed top) hoisted and fixed on roof in position over existing PCC platform incl all fitting such as connection pieces with GI tank nipple for inlet, outlet, etc complete all as specified and directed |
| 108 | S&F 20mm bore ball valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe and fixed. (Minimum weight 210gms) complete all as specified |
| 109 | S&F 15 mm size Gun-metal, globe or gate valve, with iron wheel head, screwed both ends for iron pipe and fixed complete all as spd and directed |
| 110 | M&L for 75 mm thick plain cement concrete 1:3:6, type C-2 (using 40 mm graded stone aggregate) as in plinth protection etc complete all as directed by Engr-in-charge. |
| 111 | M&L PCC 1:4:8 type D2 (using 40mm graded aggregate ) in packing under and haunching against the side of pipes of upto110mm dia bore after they are laid and tested |
| 112 | M&L for taking down carefully point wiring complete including fixture and fittings from boards/outlet boxes, fittings and fixtures such as switches, sockets, ceiling roses, lamp holders, brackets, ceiling fittings, bulk head fittings, tube light fittings and regulators, etc. and making good to disturbed area all as specified |
| 113 | M&L for Point wiring complete with ISI marked 2.5 sqmm single core PVC insulated unsheathed cable 1100V grade FRLS with multistranded copper conductor drawn through concealed in wall/ceiling surface and its accessories including PVC rigid concealed conduit heavy duty suitable size with all accessories such as bend, reducers, MS hooks, MS junction boxes, 2mm thick galvanised steel pressed sunken terminal boxes of suitable sizes for mounting of modular switchs, sockets, fan regulator etc covered with Modular sheet and covers sheet of required size fixed with brass screws and cup washers painting terminal boxes inside and outside with one coat red oxide primer including fixing and 2.5 sqmm copper conductor as earth continuity to connect common earth dolly completed, cost of modular sheet and cover are included in the item rate complete following all as specified (a)One 5 pin socket outlet point on the same board with other switches. |
| 114 | M&L for Point wiring complete with ISI marked 2.5 sqmm single core PVC insulated unsheathed cable 1100V grade FRLS with multistranded copper conductor drawn through concealed in wall/ceiling surface and its accessories including PVC rigid concealed conduit heavy duty suitable size with all accessories such as bend, reducers, MS hooks, MS junction boxes, 2mm thick galvanised steel pressed sunken terminal boxes of suitable sizes for mounting of modular switchs, sockets, fan regulator etc covered with Modular sheet and covers sheet of required size fixed with brass screws and cup washers painting terminal boxes inside and outside with one coat red oxide primer including fixing and 2.5 sqmm copper conductor as earth continuity to connect common earth dolly completed, cost of modular sheet and cover are included in the item rate complete following all as specified (a)One 5 pin,5 amps socket outlet point on independent board with other switches |
| 115 | M&L for Point wiring complete with ISI marked 2.5 sqmm single core PVC insulated unsheathed cable 1100V grade FRLS with multistranded copper conductor drawn through concealed in wall/ceiling surface and its accessories including PVC rigid concealed conduit heavy duty suitable size with all accessories such as bend, reducers, MS hooks, MS junction boxes, 2mm thick galvanised steel pressed sunken terminal boxes of suitable sizes for mounting of modular switchs, sockets, fan regulator etc covered with Modular sheet and covers sheet of required size fixed with brass screws and cup washers painting terminal boxes inside and outside with one coat red oxide primer including fixing and 2.5 sqmm copper conductor as earth continuity to connect common earth dolly completed, cost of modular sheet and cover are included in the item rate complete following all as specified (a)One light point/fan point/Exhaust controlled by one way switch |
| 116 | All as per item no. 113 here-in-before but with 4.0 sqmm cable for 1No 16 amps socket outlet point on independent board including 4.0 sqmm PVC insulated unsheathed cable multistranded with copper conductor green in colour as earth continuity conductor all as specified |
| 117 | M&L for Point wiring complete with ISI marked 1.5 sqmm single core PVC insulated unsheathed cable 1100V grade FRLS with multistranded copper conductor drawn through concealed in wall/ceiling surface and its accessories including PVC rigid concealed conduit heavy duty suitable size with all accessories such as bend, reducers, MS hooks, MS junction boxes, 2mm thick galvanised steel pressed sunken terminal boxes of suitable sizes for mounting of modular switchs, sockets, fan regulator etc covered with Modular sheet and covers sheet of required size fixed with brass screws and cup washers painting terminal boxes inside and outside with one coat red oxide primer including fixing and 1.5 sqmm copper conductor as earth continuity to connect common earth dolly completed, cost of modular sheet and cover are included in the item rate complete following all as specified (a)One 5 pin socket outlet point on the same board with other switches. |
| 118 | M&L for Point wiring complete with ISI marked 1.5 sqmm single core PVC insulated unsheathed cable 1100V grade FRLS with multistranded copper conductor drawn through concealed in wall/ceiling surface and its accessories including PVC rigid concealed conduit heavy duty suitable size with all accessories such as bend, reducers, MS hooks, MS junction boxes, 2mm thick galvanised steel pressed sunken terminal boxes of suitable sizes for mounting of modular switchs, sockets, fan regulator etc covered with Modular sheet and covers sheet of required size fixed with brass screws and cup washers painting terminal boxes inside and outside with one coat red oxide primer including fixing and 1.5 sqmm copper conductor as earth continuity to connect common earth dolly completed, cost of modular sheet and cover are included in the item rate complete following all as specified (a)One 5 pin,5 amps socket outlet point on independent board with other switches |
| 119 | M&L for Point wiring complete with ISI marked 1.5 sqmm single core PVC insulated unsheathed cable 1100V grade FRLS with multistranded copper conductor drawn through concealed in wall/ceiling surface and its accessories including PVC rigid concealed conduit heavy duty suitable size with all accessories such as bend, reducers, MS hooks, MS junction boxes, 2mm thick galvanised steel pressed sunken terminal boxes of suitable sizes for mounting of modular switchs, sockets, fan regulator etc covered with Modular sheet and covers sheet of required size fixed with brass screws and cup washers painting terminal boxes inside and outside with one coat red oxide primer including fixing and 1.5 sqmm copper conductor as earth continuity to connect common earth dolly completed, cost of modular sheet and cover are included in the item rate complete following all as specified (a)One light point/fan point/Exhaust controlled by one way switch |
| 120 | All as per item no. 117 here-in-before but with 2.5 sqmm cable for 1No 16 amps socket outlet point on independent board including 2.5 sqmm PVC insulated unsheathed cable multistranded with copper conductor green in colour as earth continuity conductor all as specified |
| 121 | S&F Modular switch 1 way 6 Amps, 1 module 230 volt AC supply complete all as specified |
| 122 | S&F Modular Socket, 6A - 2/3 pin combined 2 module, 230 volt AC supply complete all as specified. |
| 123 | S&F Modular switch 1 way 16A, 1 module 230 volt AC supply complete all as specified |
| 124 | S&F Modular Socket 6A/16A - 2/3 pin combined, 2 module, 230 volt AC supply complete all as specified. |
| 125 | S&F Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amps complete for geyser and AC point complete all as specified and directed. |
| 126 | S&F Ceiling rose surface type, 65mm x 50mm three terminals, 3 phase / PVC / polycarbonate isolated body all as specified. |
| 127 | S&F Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amps complete for geyser and AC point complete all as specified and directed. |
| 128 | Supply and Fixing LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminium hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete. |
| 129 | Supply and Fixing panel light of 10 W connecting up to three core flexible copper conductor cable complete all as sepcified and directed by Engr-in-charge. |
| 130 | S&F sheet metal enclosure for DB's SPN 230 volts 12 way with 200 amps rated bus bar neautral link, earth bar double door complete all as specified |
| 131 | Supply and fixing amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) of 40-63Amps Capacity double poles (DP) in the MCB DB complete with connection testing and commissioning complete all as specified |
| 132 | Supply and fixing 415V, 10KA 'B' curve miniature circuit breaker (MCB) of four poles (TPN) and current carrying capacity 40-100 Amps in the DB complete with connection testing and commissioning complete all as specified |
| 133 | Supply and fixing 415V, 10KA 'B' curve miniature circuit breaker (MCB) of capacity 40-63 Amps single poles and neutral in the MCB DB complete with connection testing and commissioning complete all as specified |
| 134 | Supply and fixing 240V, 10 KA 'B' curve miniature circuit breaker (MCB) of single poles and current carrying capacity 6 to 32 AMP, in the MCB DB Complete with connection testing and commissioning complete all as specified |
| 135 | M&L for submain wiring comprising single core , 2 Runs of 10 sqmm nominal cross sectional area multi stranded copper conductor cable, PVC insulated unsheathed 1100 Volts grade drawing in and including appropriate dia. in surface/recessed PVC conduit and its fittings complete including provision of 1X6 sqmm nominal cross sectional area multi stranded copper conductor cable, PVC insulated unsheathed 1100 Volts grade as earth wire and using color code as per IS and specified and making good all disturbed work to match the existing complete incl taking down old UNSV sub main complete all as specified and directed by Engr-In-charge.( Note :- Extra length of cables/ wire required for connection to MCBs shall not be measured and the rate quoted by contractor for per unit shall be deemed accordingly) |
| 136 | M&L for submain wiring comprising single core , 2 Runs of 06 sqmm nominal cross sectional area multi stranded copper conductor cable, PVC insulated unsheathed 1100 Volts grade drawing in and including appropriate dia. in surface/recessed PVC conduit and its fittings complete including provision of 1X6 sqmm nominal cross sectional area multi stranded copper conductor cable, PVC insulated unsheathed 1100 Volts grade as earth wire and using color code as per IS and specified and making good all disturbed work to match the existing complete incl taking down old UNSV sub main complete all as specified and directed by Engr-In-charge.( Note :- Extra length of cables/ wire required for connection to MCBs shall not be measured and the rate quoted by contractor for per unit shall be deemed accordingly) |
| 137 | M&L for Earthing complete with galvanised steel earth plate electrode of size 60 cm X 60 cm X 6 mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 m below normal GL connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers and earth strip protected by 15 mm dia GI pipe medium grade and connected to main distribution board panel/earthing test point all as shown on electrical plate No.3 of SSR Part I and all as specified including testing on completion including taking down old Unserviceable earthing any type all as specified |
| 138 | Supply and fix PVC air freshner fan, AC single Phase. 230V of size 300 mm sweep with, blades, and frame and louvers complete all as specified and directed. |
| 139 | Supply and fix exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 300m complete all as specified and directed. |
| 140 | Supply and fixing ceiling fans completewith blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE Five star rated with brushless direct current motor (BLDC) complete all as specified and directed. |
| 141 | Excavation in trenches, not exceeding 1.5 mtr wide and not exceeding 1.5 mtr in depth for foundations or laying cables/pipes etc. and getting out in soft/loose soil all as specified and directed by Engr-in-charge. |
| 142 | Returning, filling in including spreading leveling, watering and well ramming in layers of Soft/loose soil not exceeding 25 cm thick complete all as specifiedand directed by Engr-in-charge. |
| 143 | Removal of excavated material to a distance not exc 50 mtr and depositing where directed at level not exc 1.5 mtr above the starting point complete all as specified and directed.by Engr-in-charge |
| 144 | S & F 20 mm bore medium grade steel tubes galvanized with all fittings and laid in trenches all as specified and directed by Engr-in-charge. |
| 145 | S & F gun metal, globe or gate valve with iron wheel head screwed both ends for iron pipes 20mm bore as in repairs complete all as sepcified and directed by Engr-in-charge. |
| 146 | S & L double wall corrugated (DWC) Duct pipe-IS 16205 (electric Cable use) for cable protection laid length wise of size 50mm dia complete all as specified and directed by Engr-in-charge. |
| 147 | S & L and testing cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duties) 1100 Volts grade with stranded aluminium conductor of size 15 sq mm 2 core complete all as specified and directed. Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail