| 1 | Taking out [desludging] silt, bricks bats, debris, liquid waste, sludge in solid / semisolid state from the manholes including pumping out liquid / semi solid waste if any with the help of honey sucker machine and removing the debries outside MD land, wherever necessary, slugging, diverting the flow in the drain, if necessary and staking the removed silt/sludge in deposit away from the edge of manholes as directed including use of safety belt, dry cells torch for lighting in side the man hole and taking similar safety measures and cleaning the manholes with clean water etc complete all as specified and as directed for manholes of any size and depth not exceeding 1.00 meter |
| 2 | All as per ser item no 1 here-in-before but manholes of any size and depth exceeding 1.00 meter but not exceeding 2.00 meter |
| 3 | All as per ser item no 1 here-in-before but manholes of any size and depth exceeding 2.00 meter but not exceeding 4.50 meter |
| 4 | M&L for Bailing out water from existing septic tank and filter bed including inspection chamber and getting out sludge and other accumulated materials complete by mannually or using the honey sucker machinery for work in foul position or in liquid mud all as directed by Engineer -In - Charge including refilling the water all as directed for any capacity |
| 5 | Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in soft/loose of soil. Note:-(1) The excavation work will be carried out by mannualy or mechanical means in any location/ area as directed by engr-in- charge. (2) Any dammage occur to water supply pipe line/ electric cable/existing drain/sewage line during excavation work will be make good by the contractor without any extra cost to Govt & up to satisfaction of Engr- in-charge. |
| 6 | All as per srl item No 5 here-in-before but depth exc 1.50 m but n. exc 3.00 m |
| 7 | Demolition and breaking up drain pipes of internal dia 150/200 mm in cement mortar including bedding and hunching complete all as specified and directed. |
| 8 | M&L for HDPE DWC (Double wall corrugated) Pipes confirming to IS-16098, of 150mm internal dia, pressure rating SN-8 fixede with rubber seal and coupler required with and including suitable bends 90/60/45 degree etc, single Y junction, complete as required, fixed as per manufacturer instructions laid in trenchs for sewage lines including testing complete all as specified and as directed. |
| 9 | M&L for HDPE DWC (Double wall corrugated) Pipes confirming to IS-16098, of 200mm internal dia, pressure rating SN-8 fixede with rubber seal and coupler required with and including suitable bends 90/60/45 degree etc, single Y junction, complete as required, fixed as per manufacturer instructions laid in trenchs for sewage lines including testing complete all as specified and as directed. |
| 10 | M&L for concrete (1:4:8) type D2 (using 40 mm graded crushed stone aggregate) as in foundations, filling, mass-concrete, and bed to drain pipes complete all as specified and directed |
| 11 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm with any type of soil complete all as specified and directed. |
| 12 | Removing excavated Soils material exc. 250m but n exc. 500 m and depositing where directed |
| 13 | Demolition of brick work, stone/boulder masonry built in cement mortor incl all quions, arches, pillars etc. |
| 14 | M&L for brick work with sub class 'B' bricks, straight or curved on plan exc 6 m mean radius built in CM 1:6 |
| 15 | Demolition of cement concrete (unreinforced) in any description or in any position not otherwise provided for |
| 16 | Demolition of Reinforced Cement Concrete of any description and in any position not otherwise specifically provided for RCC structures including cutting of reinforcement as required to facilliate demolition. |
| 17 | M&L for providing Precast Cement Concrete Type B-1, 1:2:4 (20mm graded crushed stone aggregate) in landings, cover slabs (for manholes etc.) , water troughs and similar articles with plain faces and setting in cement mortar 1:6 complete with joints to match |
| 18 | M&L for Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking , bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia . |
| 19 | All as per srl item No 18 here-in-before but 6 to 8 mm dia |
| 20 | Taking down of cement plaster any description including raking out joints, hacking for key scrubbing down with water etc and removing rubbish to a distance not exceeding 250 m. |
| 21 | M&L for rendering 15 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:4 complete all as specified and directed |
| 22 | M&L for 75 mm thick PCC as in plinth protection / apron type C-2, 1:3:6 (40 mm graded crushed stone agg) finishing surfaces even and smooth without using extra cement and spike rolling complete all as specified & directed. |
| 23 | M&L for 100 mm thick PCC 1:2:4 type B-2 (using 20mm graded crushed stone aggregate) as in floor and finishing even and smooth with using extra cement complete all as specfied and directed. |
| 24 | M&L for non abrasive paving (endura) tiles 300mm x 300mm x10mm thick (square/ rectangular) polished, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement over & including 15mm screed bed CM 1:4 to match including taking down old tiles complete al as specified and directed.Note:-The texture ,colour ,Shade of tiles & laying of tiles to any pattern & any design with one or more colours shall be approved by GE and Rates also including dismantling old tiles and in this item for necessary raking circular cutting or notching and waste on tiles as directed ny Engr-in-charge. |
| 25 | M&L for 75mm thick plain cement concrete 1:4:8, type D-2 using 40mm graded crushed stone aggregate as in sub base complete all as specified and as directed. Note:- Finishing surfaces of concrete to be even and rough to receive the topping layer. |
| 26 | M&L for machine pressed precast concrete interlocking paver block any shape & size confirming to IS 15658-2006 of 60 mm thickness, M-40 grade rubber moulded glossy finish with grey cement and pigment complete all as secified and as directed.Note-Shapes of interlocking paver block shall be triangular/Zigzag/Haxagon/or other ,Colour of paver blocks & laying pattern approved by GE. |
| 27 | M&L for sand filling under floors or in foundations including watering and consolidation or layer of sand cushioning below interlocking paver block complete all as specified and as directed. |
| 28 | Demolition and breaking up drain pipes (Salt glazed ware, PVC/AC or Reinforced concrete) set in cement mortar,and taking out of trenches, if required, Internal dia of pipe in 75MM/100mm |
| 29 | S&F PVC (SWR) pipes 75mm bore single socketed, in any length with rubber ring joints laid in trenches or in floors all as specified and directed. |
| 30 | S&F PVC (SWR) pipes 110mm bore single socketed, in any length with rubber ring joints laid in trenches or in floors all as specified and directed. |
| 31 | Taking down eaves gutter and rain water pipe any size any pattern , PVC/ AC pipe including all fittings ,heads shoes, bends etc including removal to store ,Internal dia of pipe in 75MM/110mm complete all as specified and directed.all as specified and directed. |
| 32 | S&F PVC (SWR) pipes 75mm bore single socketed in any length with rubber ring joints fixed to walls all as specified and directed. |
| 33 | S&F PVC (SWR) pipes 110mm bore single socketed in any length with rubber ring joints fixed to walls all as specified and directed.(ISI MARKED) |
| 34 | S&F PVC (SWR) bends any radius 75mm dia all as specified and directed.(ISI MARKED) |
| 35 | S&F PVC (SWR) bends with access door any radius 75mm dia all as specified and directed.(ISI MARKED) |
| 36 | S&F PVC (SWR) bends any radius 110mm dia all as specified and directed.(ISI MARKED) |
| 37 | S&F PVC (SWR) bends with access door any radius 110mm dia all as specified and directed.(ISI MARKED) |
| 38 | S&F in repairs 75mm PVC floor trap, ISI marked with cp grating with/without waste pipe hole incl jointing to waste pipe fixed with solvent cement complete all as specified and as directed. |
| 39 | S&F PVC (SWR) Single 'T ' any radius 110mm dia all as specified and directed.(ISI MARKED) |
| 40 | S&F PVC (SWR) Single 'T' radius 75mm dia all as specified and directed.(ISI MARKED) |
| 41 | Surface excavation not exc 30 cm depth and averaging 15cm deep in foul condition for removing heaps of waste, cleaning of flora, fauma, follage and bushes around septic tanks,manholes and soak pits removing debris/ heaps of bushes etc from vicinity and depositing at a place where complete all as specified and as directed |
| 42 | S&F in repair wash down water closet (pedestal pattern) complete vitreous china wash down water closet pan (pedestal pattern) white(excluding flushing cistern) , white closed pattern with flat bottom and cover complete all as specified and directed |
| 43 | S&F in repair plastic water closet seat cover, Cream / white colour, closed pattern with flat bottom and cover and mild steel chromium plated aluminium hinging device for pedestral pattern WC. |
| 44 | S&F in repair vitreous china wash down water closet (Orissa pattern white of size 580 mm x 440mm with integral foot rest, CI \\"P\\" or \\"S\\" trap all fittings complete including connection to trap and to flushing pipe anti syphonage pipe including making good to floor,cleaning surface etc complete all as specified and as directed (fixed in repairs) |
| 45 | Systematically cleaning of sewage line in any depth including affected/connected manholes and desludging, dewatering of man hole of any size by mechanical sucking/pressure pump(truck mounted) including cleaning of connected sewage pipe line of size 100/150/160/200/300mm bore laid in trenches and any length,including water closet, gully trap etc by hydraulic jet pressure machine as required at site flushing the line and manholes with water as to make the fully functional line with man hole to entire satisfaction of Engr-in-charge and removing sludge out side the periphery of defence land at his own arrangement where sanitary hazards do not take place as per direction/instruction of civil authority and burried in excavated pits and covering the same. Adequate water for flush out sludge to be arranged by the contractor without any extra cost.Pipe line including manholes cleared/ cleaned under this item is to arranged by the contractor without any extra cost.pipe line including manholes cleared/cleaned under this item is to be maintained by the contractor and kept fully functional by removing any type of blokage of entire period of completion of work without any extra cost and refixing manhole cover after cleaning all as specified and directed. Note: unit rate quoted by tendere shall include taking out sludge from line and manhole(liquid,semi-liquid,solid) excavation of borrow pit for dumping sludge, removing including loading, unloading and transportation etcNote:- Manhole cleaning in any depth area desluding, dewatering of man hole and etc is included in item no 01, 02 and 03. |
| 46 | To attend and rectify of sewage system complaint in daily routine basis as per complaint lodged by user at complaint cell of AGE B/R-II Sub division by deploying manpower by cleaning/clearing/removal blockage such as blockage/ chocked in any type/size/height/depth/location of WCs/urinal/bathroom /kitchen /WHB upto 1st manhole of sewage line along with any type/size/height/depth bore of outlet SGSW/PVC/CI/ UPVC/RCC etc pipe & including all kind of traps such as inspection chamber/Floor/ Nahani /Gully /Intercepting /bottle trap/P or S/multi floor traps of any type SGSW/PVC/CI/UPVC etc and in any position below or above ground level, in any floor, located in different situations, including opening/clearing eyes of sewage waste pipes/vent pipe etc, opening the access cover/grating and taking out/removing all material such as sludge/ soil waste/sludge water/polythene /mud/silt/liquid/semi liquid / semi solid/solid /bricks bats/debris/soil etc any unwanted materials of any kind etc including flushing with adequate water after cleaning make the all system fully functional to the entire satisfaction of Engr-in-Charge, re-fixing the existing opened access cover and removing all retrieved material/unwanted/foreign material in any liquid/solid state etc outside the periphery of defence land at his own arrangement where sanitary hazards do not take place as per directions/ instructions of civil authority and buried in excavated pits in suitable size and depth and covering the same minimum 25cm thick compacted layer of soil with the soil obtained from excavation of pit including all excavations and earth work including applying bleaching powder to maintain hygiene. Adequate water for flush out be arranged by the contractor without any extra cost complete all as specified and directed.(Note :The Contractor or his authorised rep shall collect the complaint of all blockage of sewage from complaint cell / JE daily and all complaint will be rectified by the contractor within the same day and returned the complaint slip after completion of compaint and get receipt from concern JE. If he fails to complete the work within same day then recovery will be made @ 150 per complaint per day. ) |
| 47 | Notes :-(i) Contractor accredited representative shall be available during cleaning. (ii) Unit rate quoted by tenderer shall included for all precautions to be taken by workers while working in foul condition, Contractor shall take all necessary actions. (iii) Unit rate quoted by tenderer shall include excavation of borrow pits for dumping, removing including loading/ unloading and transportation in covered container etc(iv) Unit rate quoted by tenderer shall included for Washing, cleaning floors with adequate water of any type of drops and splashes and leaving premise clean and tidy. (v) Unit rate quoted by tenderer shall included for use of all scaffolding, trestles, ladders, cradles etc ,hoisting, lowering and protective measures etc up to four storeys height of bldgs.(vi) Unit rate quoted by tenderer shall included to repair damaged water/ electric line during excavation work. (vii) Contractor will ensure to remove the foul material in packed containers. |
| 48 | Note:-The accepted amount will be arrived after deducting the Sch of credit i.e. Rs 44,425.00 and any other reduction if any from quoted amount. Please Enable Macros to View BoQ information |