| 1 | Material and labour for Comprehensive maintenance of D.G set (Make : Kirloskar/Mahindra/Crompton Greaves )periodical servicing including first hand repairs as required consisting of normal repair such as tightening of nuts, bolts, greasing, checking levelling of distilled water / oil / coolant etc. and cleaning of main battery charging alternator where ever exists including checking and taking out defective /worn out parts complete all as specified and directed for the following capacity D G Set :-NoteS :- (i) Spare parts required to be replaced shall be measured & paid for separately under relevant items of scheduled 'A' and taking out old unserviceable parts shall be deemed to be included in the qouted rate of this item . |
| 2 | (i) 250 KVA |
| 3 | (ii) 160 KVA |
| 4 | (iii) 100 KVA/125 KVA |
| 5 | (iv) 62.5 KVA/ 63 KVA |
| 6 | (v) 35 KVA |
| 7 | (vi) 25 KVA |
| 8 | (vii) 10 KVA |
| 9 | (viii) 7.5 KVA |
| 10 | Supply and fixing of Diesel filter with 'O' Ring suitable for following capacity of D. G. set as per existing sample complete all as specified and directed :-Make of DG Set: Kirloskar/Mahindra/Crompton Greaves. |
| 11 | (i) 250 KVA |
| 12 | (ii) 160 KVA |
| 13 | (iii) 100 KVA/125 KVA |
| 14 | (iv) 62.5 KVA/ 63 KVA |
| 15 | (v) 35 KVA |
| 16 | (vi) 25 KVA |
| 17 | (vii) 10 KVA |
| 18 | (viii) 7.5 KVA |
| 19 | Supply and fixing of Air filter element suitable for following capacity of D. G. sets as per existing sample complete all as specified and directed :-Make of DG Set: Kirloskar/Mahindra/Crompton Greaves. |
| 20 | (i) 250 KVA |
| 21 | (ii) 160 KVA |
| 22 | (iii) 100 KVA/125 KVA |
| 23 | (iv) 62.5 KVA/ 63 KVA |
| 24 | (v) 35 KVA |
| 25 | (vi) 25 KVA |
| 26 | Supply and fixing of oil filter element with 'O' Ring suitable following capacity of D. G. sets as per existing sample complete all as specified and directed :-Make of DG Set : Kirloskar/Mahindra/Crompton Greaves |
| 27 | (i) 250 KVA |
| 28 | (ii) 160 KVA |
| 29 | (iii) 100 KVA/125 KVA |
| 30 | (iv) 62.5 KVA/ 63 KVA |
| 31 | (v) 35 KVA |
| 32 | (vi) 25 KVA |
| 33 | (vii) 10 KVA |
| 34 | (viii) 7.5 KVA |
| 35 | Supply & fixing of set of belts suitable for following capacity D. G. sets as per existing sample complete all as specified and directed (Each set included dynamo belt, Fan belt and water pump belt) :-Make of DG Set : Kirloskar/Mahindra/Crompton Greaves |
| 36 | (i) 250 KVA |
| 37 | (ii) 160 KVA |
| 38 | (iii) 100 KVA/125 KVA |
| 39 | (iv) 62.5 KVA/ 63 KVA |
| 40 | (v) 35 KVA |
| 41 | (vi) 25 KVA |
| 42 | (vii) 10 KVA |
| 43 | (viii) 7.5 KVA |
| 44 | Supply and fixing of set of Rubber Hose for water & Air circuit suitable for following capacity D. G. sets complete all as specified and directed:-Make of DG Set : Kirloskar/Mahindra/Crompton Greaves. |
| 45 | (i) 250 KVA |
| 46 | (ii) 160 KVA |
| 47 | (iii) 100 KVA/125 KVA |
| 48 | (iv) 62.5 KVA/ 63 KVA |
| 49 | (v) 35 KVA |
| 50 | (vi) 25 KVA |
| 51 | (vii) 10 KVA |
| 52 | (viii) 7.5 KVA |
| 53 | Taking down defective self-starter 12/24 Volt of D. G. set of capacity 100 KVA to 250 KVA installed at various installations including servicing, overhauling including replacing worn out parts like solenoid, bearing, carbon brush etc. , rewinding the starter motor and refixing the same after repairs for smooth functioning complete all as specified and directed. |
| 54 | All as per Srl. Item No. 53 but for D. G. Set of capacity 10 KVA to 63 KVA. |
| 55 | Material and labour for cleaning the fuel tank both internally & Externally by removing all the dust / sediments, etc. in cluding writing of tank capacity, Date of cleaning of following capacity D. G. Set complete all as specified and directed for following capacity :- |
| 56 | (i) 250 KVA |
| 57 | (ii) 160 KVA |
| 58 | (iii) 100 KVA/125 KVA |
| 59 | (iv) 62.5 KVA/ 63 KVA |
| 60 | (v) 35 KVA |
| 61 | (vi) 25 KVA |
| 62 | (vii) 10 KVA |
| 63 | (viii) 7.5 KVA |
| 64 | Material and labour for scrapping, cleaing the existing paint completely and painting with two coats of anti corrosion synthetic enamal paint with spray painting gun of approved colour of following capacity D. G. sets (Internal & External) including fuel tank etc. ( Colour code as per existing colour) including removing all stricker/rediam and providing new strickre as per existing complete all as specified and directed :- |
| 65 | (i) 250 KVA |
| 66 | (ii) 160 KVA |
| 67 | (iii) 100 KVA/125 KVA |
| 68 | (iv) 62.5 KVA/ 63 KVA |
| 69 | (v) 35 KVA |
| 70 | (vi) 10 KVA |
| 71 | Material & Labour for removing the fuel injection pump from D. G. set of capacity 100 to 250 KVA and carrying out servicing & calibration from authorised service workshop including replaceement of injectors, Nozzles, etc. and refitting the same for smooth and efficient functioning complete all as specified and directed. Make of DG Set : Kirloskar |
| 72 | As per Item No. 71 but for D.G. Sets of capacity 35 to 63 KVA. |
| 73 | As per Item No. 71 but for D.G. Sets of capacity 7.5 to 25 KVA. |
| 74 | Material & Labour in replacement for stater switch of DG set of capacity 63 to 250 KVA as per existing complete all as speciifed and directed. |
| 75 | Material and labour for disconnecting the radiator from engine frame and servicing, cleaning with acid and brazing where required to stop leaking tubes, joints etc. including cleaning fins and re-fixing the same and testing complete for following capacity DG Set complete all as speciifed and directed :- (Make of DG Set : Kirloskar/Mahindra/Crompton Greaves) |
| 76 | (i) 100 KVA to 250 KVA |
| 77 | (ii) 35 KVA to 63 KVA |
| 78 | (iii) 7.5 KVA to 25 KVA |
| 79 | Material & Labour for repair of turbo charge by replacing repair kit & fixing the same on D. G set 35 KVA to 250 KVA complete all as speciifed and directed. |
| 80 | Supply and fixing in repair water pump for D G Set of following capacities complete all as specified and directed :- |
| 81 | (a) 250 KVA |
| 82 | (b) 160 KVA |
| 83 | (c) 100 KVA/125KVA |
| 84 | (d ) 35 KVA to 63 KVA |
| 85 | (e) 7.5 KVA to 25 KVA |
| 86 | Material & Labour for pouring of Egine Oil, 15W-40 complete all as specified and directed. |
| 87 | Material & Labour for pouring Coolant for Engine of DG Set complete all as speciifed and directed. |
| 88 | Material & Labour for pouring of Electrolyte of suitable spigravity for lead Acid batterries complete all as speciifed and directed. |
| 89 | Material & Labour for pouring of distiled water for battery complete all as speciifed and directed. |
| 90 | Supply and fixing fuel pipe steel braded with Benzo bolt & washer etc. of lenth 30 cm complete all as speciifed and directed. |
| 91 | Supply and fixing fuel pipe steel braded with Benzo bolt & washer etc. of lenth 60 cm complete all as speciifed and directed. |
| 92 | Supply and fixing fuel pipe steel braded with Benzo bolt & washer etc. of lenth 100 cm complete all as speciifed and directed. |
| 93 | Supply anf fixing Exhaust mainfold end flexiable coupling stainlen steel as per existing sample complete all as speciifed and directed. |
| 94 | Taking down the existing perished/damaged asbestos rope and supply & replace with new asbestos rope 10 mm thick on the exhaust pipe of any dia bore including covering complete all as speciifed and directed. |
| 95 | Supply & fixing in replacement automatic voltage regulator as per existing for 100 to 125 KVA D. G. set complete all as specified and directed.Make of DG Set : Kirloskar |
| 96 | Supply & fixing in replacement automatic voltage regulator as per existing for 160 KVA D. G. set complete all as specified and directed.Make of DG Set : Kirloskar |
| 97 | Supply & fix in replacement of automatic voltage regulator as per existing for 250 KVA D. G. set complete all as specified and directed.Make of DG Set : Kirloskar |
| 98 | Supply & fix in replacement of automatic voltage regulator as per existing for 25 to 63 KVA D. G. set complete all as specified and directed.Make of DG Set : Kirloskar |
| 99 | Supply and fixing battery leads set, PVC insulated multi stranded cooper 70 sq mm of 1.25 meter long each duly fixed with bran clamps complete all as speciifed and directed. |
| 100 | Supply and fixing brans battery terminal suitable for lead acid, battery 12 v any AH complete all as speciifed and directed. |
| 101 | Supply & fixing in replacement digital ammeter 0 to 300 Amps complete all as speciifed and directed. |
| 102 | Supply & fixing in replacement digital Voltmeter 0 to 500 Amps complete all as speciifed and directed. |
| 103 | Supply & Fixing Engine Oil pressure gauge meter up to 7 kg complete all as specified and directed. |
| 104 | Supply & Fixing Engine water temp. meter complete all as specified and directed. |
| 105 | Supply and fix in repairs change over switch existing panel, wall or LT pole of any size and any type off load type, triple pole and neutral, 100 Amps, 415 V, 50 Hz side handle operated, including connecting and testing complete all as speciifed and directed.Make : Havells, Indoasian, C&S/L&T |
| 106 | All as per item No above 105 but off load type, 200A side handle operated,including connected accssories complete all as specified and directed. |
| 107 | All as per item No above 105 but off load type, 250A side handle operated,including connected accssories complete all as specified and directed. |
| 108 | Supply & Fixing in repair change over switch on load complete compact type front operater handle from existing LT Panel TPN 630 Amp 415 Volts, 50Hz compacts including making electric connection all as specified and directed.Make : Havells/Indo Asian/C&C/L&T. |
| 109 | Material & Labour in replacement for Door Hinges of various capacity of DG Set complete all as specified and directed. |
| 110 | Material & Labour in replacement for Door lock of various capacity of DG Set as per existing at site of any capacity complete all as speciifed and directed. |
| 111 | Supply & Fixing in replacement of contractor MNX 225 2 No + 2 NC ,3 pole power contractor current rating AC 3 :225 Amp,AC1 :300 Amp or as per existing at site of capacity of DG set 100 to 160 KVA complete all as speciifed and directed.Make : Havells, L&T, C&S. |
| 112 | Supply & Fixing in replacement of MCCB 250 Amps, three pole,25 KA complete all asspecified and directed. |
| 113 | Supply & Fixing in replacement of Indicator lamp of colour (red,yellow,green) of dg set panel of any capacity of DG set including all connecting circuits complete all as speciifed and directed. |
| 114 | Material and labour for perodical maintenance brake down on call repairs of EOT Crane 2 Ton long travel motor, cross travel motor, gear box , control panel etc. installed at armoured static work shop and replacement of unserviceable spare parts at site complete all as specified and directed. (02 Nos) Note:- Rate includes for greesing, cleaning, oiling etc. |
| 115 | Material and labour for perodical maintenance brake down on call repairs of EOT Crane 5 Ton long travel motor, cross travel motor, gear box , control panel etc. installed at armoured static work shop and replacement of unserviceable spare parts at site complete all as specified and directed. (02 Nos) Note:- Rate includes for greesing, cleaning, oiling etc. |
| 116 | Notes for Srl Item Nos. 114 to 115 Please Enable Macros to View BoQ information |
| 117 | Notes for Srl Item Nos. 114 to 115 Please Enable Macros to View BoQ information |