|
| 1 | Note :(i) Please refer Sch A/ BOQ Notes before quoting the tender for all phases/ items mentioned below.(ii) Amount of Schedule of credit shall be deducted offline |
| 2 | Excavation in trenches, not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation, etc or not exceeding 10 Sqm on plan and not exceeding 1.5m in depth for shafts, cesspits, manholes, pier holes, etc and getting out in hard/dense of soil complete all as specified and directed. |
| 3 | All as per Item No.1.00 but exc 1.5m in depth |
| 4 | M&L for cement concrete 1:4:8 type D-2 (using 40 mm graded stone agg) as in foundation , filling, subbase and mass incl Demolition of cement concrete in floors and pavings not exc. 15 Cm thickness (below/above ground level) including floor finishesconcrete complete all as specified and directed. |
| 5 | S&F 200mm (DWCPE Pipe) class SN-8 structural Wall polyetylene ( Pipe with online coupler and elastomeric rubber ring ) with hollow annular smooth outer surface and a smooth inner surface ( double wall plain ) for non pressure unerground drainage and sewage application Type B Nomial size ( Dn /ID ) made of polyethylene ( PE ) materia;l confirming to ISI 6098 ( Part II : 2013 and to be transported handled installed and joied asper Annex A Of ISI 6098 ( part II :2013 including demolition of old drain pipes (SGSW, AC, RCC or PVC)complete all as specified |
| 6 | S&F 300mm (DWCPE Pipe) class SN-8 structural Wall polyetylene ( Pipe with online coupler and elastomeric rubber ring ) with hollow annular smooth outer surface and a smooth inner surface ( double wall plain ) for non pressure unerground drainage and sewage application Type B Nomial size ( Dn /ID ) made of polyethylene ( PE ) materia;l confirming to ISI 6098 ( Part II : 2013 and to be transported handled installed and joied asper Annex A Of ISI 6098 ( part II :2013 including demolition of old drain pipes (SGSW, AC, RCC or PVC)complete all as specified |
| 7 | M&L for 200mm reinforced concrete pipes, class NP 2, laid and jointed complete with collars complete including demolition of old drain pipes (SGSW, AC, RCC or PVC) all as specified and directed. |
| 8 | M&L for 300mm reinforced concrete pipes, class NP 2, laid and jointed complete with collars complete including demolition of old drain pipes (SGSW, AC, RCC or PVC) all as specified and directed. |
| 9 | Removal of surplus spoil/excavated material to a distance upto 50 m and depositing where directed at a level n exc. 1.5 m above the starting point. |
| 10 | Returning filling in, approved earth including spreading, levelling, watering and well ramming in layers n.exc 25cm thick, complete all as sspecified and directed. |
| 11 | S&F in repair 75mm PVC (SWR) pipes single socketed, in any length with rubber ring joints laid in trenches or fixed to walls including clamps. |
| 12 | S&F in repair 110mm PVC (SWR) pipes single socketed, in any length with rubber ring joints laid in trenches or fixed to walls including clamps. |
| 13 | S&F in repair 75mm bore PVC (SWR) bend. |
| 14 | S&F in repair 110mm bore PVC (SWR) bend. |
| 15 | S&F in repair 75mm bore PVC (SWR) junction single (single 'T') equal or unequal. |
| 16 | S&F in repair 110mm bore PVC (SWR) junction single (single 'T') equal or unequal. |
| 17 | S&F in repair 75mm bore PVC(SWR) vent cowl. |
| 18 | S&F in repair 110mm bore PVC(SWR) vent cowl. |
| 19 | S&F in repairs 100 mm dia PVC (SWR) floor/Nahani trap with grating including jointing to waste pipe fixed with solvent cement |
| 20 | M&L for 75mm thick PCC 1:4:8, type D-2 as in floor to receive floor finishes, complete all as specified. |
| 21 | M&L for 25mm thick PCC 1:2:4, type B-1 (20 mm graded aggregate) as in floor to receive floor finishes, complete all as specified. |
| 22 | M&L for non skid ceramic coloured tiles 7mm to 8mm thick (square /rectangular ) area of each tile exceeding 0.11 sqm , but not exceeing 0.18 sqm ,over and including 15mm thick screed in CM 1:6 etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the shades of tiles incl Dismantling floor, hearth or wall tiling including cement mortar bedding(but not backing), removing serviceable tiles and rubbish off the permises compelte all as specified & directed. |
| 23 | M&L for glazed tiles , coloured 300x450 x 6 to 7 mm thick as in skirting/dado over & including 10mm thick rendering in CM 1:4 set & jointed in neat cement slurry & pointed in white or coloured cement incl Dismantling floor, hearth or wall tiling including cement mortar bedding(but not backing), removing serviceable tiles and rubbish off the permises compelte all as specified & directed all as specifeid & directed . |
| 24 | S&F in repairs vitreous china squatting pan \\"Orissa Pattern\\" size 580mm x 440mm white with integral foot rests, including prov of cement concrete bedding and 'P' or 'S' trap as required complete all as specified and directed. |
| 25 | S&F in repairs PVC low level flushing cistern 10 ltrs capacity with all internal fittings incl flush pipe and fixing to supply pipe including PVC connection 600 mm long 15 mm bore with brass heads & washers with connections fixed complete all as specified and directed. |
| 26 | S&F China wash down water closet pan (Pedestal Pattern), white , pedestal pan and 'P' or 'S' trap , plastic water closet seat , white, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device complete all as specified. |
| 27 | S&F in repairs 32mm PVC waste pipe 80cm long complete all as specified and directed. |
| 28 | M&L for burnt Brickwork Modular bricks with subclass ‘B’ bricks, straight or curved on plan exc 6m mean radius, built in cm 1:6 including demolition of old bricks all as specified and directed. |
| 29 | M&L for PCC 1:2:4 type B-1 (Using 20 mm graded aggregate) as in coping, channel, benching of manhole laid to shape and slope and finished even and smooth using extra cement including weathering, throating and necessary form work complete all as specified and directed. |
| 30 | M&L for 15 mm thick plaster in CM 1:4 on brick walls or concrete surfaces and in any position including finishing the surfaces fair and even (without using extra cement), complete all as specified and directed. |
| 31 | Demolition of cement concrete reinforced (reinforcement cut as required to facilitate demolition) in any description and in any position not other wise specifically provided for complete all as specified and directed. |
| 32 | S & F in repair 600 x 600mm x 70 mm factory made precast cement concrete cover M-20 with 8 mm dia ,MS Bar @ 100 mm c/c both way and MS hook Both side complete sizes - ( Rate Inclusive of reinforcement and Hook ) |
| 33 | S & F in repair 450x600 mm x 70 mm mm factory made precast cement concrete cover M-20 with 8 mm dia ,MS Bar @ 100 mm c/c both way and MS hook Both side complete sizes - ( Rate Inclusive of reinforcement and Hook ) |
| 34 | S & F in repair 450x 900 mm x 70 mm mm mm factory made precast cement concrete cover M-20 with 8 mm dia ,MS Bar @ 100 mm c/c both way and MS hook Both side complete sizes - ( Rate Inclusive of reinforcement and Hook ) |
| 35 | M&L form work to soffits of suspended slabs such aa slabs, floor slabs, landings and drain, wall not exceeding 200 mm thick (Horizontal/Sloping) receive for fair finished surfaces complete all as specified and directed. |
| 36 | M&L for reinforced cement concrete (nominal mix) using 20mm graded aggregate Type B1 1:2:4 on as in slabs, walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed. |
| 37 | M&L Mild steel TMT bars 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed. |
| 38 | Providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footparth, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand |
| 39 | Cleaning and de-sludging of 300 user septic tanks of following user size of any depth including taking out sludge in any form alongwith all other forign materials by mechanical Pumping equipment with taking all precautionary measures including removal of sludge and other foreign materials out side Defence land by any means complete (working in foul condition) all as specified and directed by Engr-in-Charge |
| 40 | Cleaning and de-sludging of 250 user septic tanks of following user size of any depth including taking out sludge in any form alongwith all other forign materials by mechanical Pumping equipment with taking all precautionary measures including removal of sludge and other foreign materials out side Defence land by any means complete (working in foul condition) all as specified and directed by Engr-in-Charge |
| 41 | Cleaning and de-sludging of 200 user septic tanks of following user size of any depth including taking out sludge in any form alongwith all other forign materials by mechanical Pumping equipment with taking all precautionary measures including removal of sludge and other foreign materials out side Defence land by any means complete (working in foul condition) all as specified and directed by Engr-in-Charge |
| 42 | Taking down chowkhats or frame with shutter n.exc 1.5 sqm each with shutters (without taking off shutters from the frame) complete all as specified and directed |
| 43 | S & F Solid PVC door frame of size 50 mmx 47mm made out of 5 mm plain colour PVC sheet reiforced with MS square tube and fixing in opening as per manufacturer instruction complete all as specified, directed. |
| 44 | S & F factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of MS tubes for top and bottom rails. MS frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20 mm width struck inside with solvent cement for stiles and plain colour PVC sheet for top rail, lock rail and bottom rail on either side and gap insert for top rail and bottom rail, panelling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the stiles and rails with suitable PVC sheet beading and jointed together with solvent cement including 100 mm aluminium butt hinges 03 Nos,Aluminium Handle-02 Nos, aluminium tower bolt 150 mm -01 No and alumiium sliding door bolt 150 mm - 01 No. Complete all as specified and as directed. |
| 45 | Hiring of Super-Sucker and jetting machine having sufficient capacity for effective depth up to 10 Mt i/c 20 HP submersible pump set with electric panel board, 62.5 KVA Diesel generator set and suction hose pipes with all fittings i/c cost of manpower (1 No. qualified Engineer, 2 Nos. driver, 4 Nos. S.G. Beldars, 2 Nos. Operators), and cost of Diesels, Lubricants, insurance, safety equipment's, Mobilization charges etc. all complete as per satisfaction of Engineer-In-Charge for 8 hrs. shift per day. |
| 46 | Cleaning of all blockage of any type of sewage line ie branch sewer line, main sewer line etc, manholes of any size and depth, in any situation by way of cleaning/desludging by manually or mechanically or by way of any other suitable means including foreign materials as well as rodding (full through) of sewer lines and between the blocked manholes where required and ordered by Engineer-in-charge and keeping the sewage line all time functional; cleaning traps, water closet, soil waste/vent pipe, gully traps etc complete upto final drop out let into septic tanks or central sewage treatment plant and/or soakage well (working in foul condition) with taking precautionary measures with necessary equipment as required and applicable all as specified and directed. The sludge removed from the manholes and sewage line shall be removed to out side Defence land complete all as directed by Engineer-in-charge in entire Bairagarh Military Station i.e., various units area and single living Accn Note:-Note 1 : Contractor will deploy 04 (four ) Nos safaiwala and 01 (one) supervisor per working day in the MES office/complaint cell and will report to the concerned JE/Engineer-in-Charge daily at 9.00 AM to 5.00 PM.Note 2 : If any of the Safaiwala/Supervisor fails to report daily to the concerned authority, a sum of Rs. 700/- will be deducted per person/day from the payment of the contractor.Note 3 : The Safaiwala will always be in posession of the cleaning tools like 6mm MS round bar/rod, plain flexible bamboo pieces and cleaning pump with wooden/PV |
| 47 | Deduct Schedule of credit (calculation will be done off line) Rs. 13340.00 Please Enable Macros to View BoQ information |