| 1 | M&L for testing of Bore well water to analyse the following parameters as per IS 10500:2000 through Govt. approved/NABL approved laboratory:-(a) Physicochemical analysis of water(b) Bactoriological analysis of water. Note:- Test to be carried out on quarterly basis ( No of Borewells -04) |
| 2 | Supply only TCCA (TriChloroiso Cyanuric Acid ) 90% chlorine granular in sealed plastic container complete all as specified and directed. |
| 3 | S&F in replacement Framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe-290. Gde-E-165 complete all as specified and directed. |
| 4 | S & F in replacement bronze ball / gate valve with handle, screwed both ends suitable iron pipe complete all as directed for following size:- |
| 5 | (a) 15 mm dia |
| 6 | (b) 20 mm dia |
| 7 | (c) 25 mm dia |
| 8 | S & F in replacement UPVC ball valve with handle, both side socket ends suitable for 15mm dia pipe complete all as specified and directed. |
| 9 | S & F in replacement UPVC ball valve with handle,both side socket ends suitable for 20mm dia pipe complete all as specified and directed. |
| 10 | S & F in replacement UPVC ball valve with handle, both side socket ends suitable for 25mm dia pipe complete all as specified and directed. |
| 11 | S & F in replacement sluice valve 80 mm bore cast iron flanged & drilled both ends (ISI marked) Class PN- 1.6, Non Rising stainless steel spindle including all jointing materials and mild steel nuts, bolts, washers and gasket etc complete all as specified and directed. |
| 12 | S & F in replacement sluice valve 100 mm bore cast iron flanged & drilled both ends (ISI marked) Class PN- 1.6, Non Rising stainless steel spindle including all jointing materials and mild steel nuts, bolts, washers and gasket etc complete all as specified and directed. |
| 13 | M&L for taking up or down steel tubing 25/32 mm bore pipe of any type with all fittings and accessories etc, from trenches/ surface and removing blockage and damaged pipe complete including cleaning the serviceable pipe for re-fixing complete all as specified and directed.(Note:- Excavation/ earth work will be measured and paid separately under respective items.) |
| 14 | M&L for taking up or down steel tubing 40/50 mm bore pipe of any type with all fittings and accessories etc, from trenches/ surface and removing blockage and damaged pipe complete including cleaning the serviceable pipe for re-fixing complete all as specified and directed.(Note:- Excavation/ earth work will be measured and paid separately under respective items.) |
| 15 | Supply and fix in replacement of tubes \\"medium grade \\" of size 20 mm galvanised ISI marked with all fittings and fixed to walls and ceilings or laid in floors/trenches/under road including cutting and making the surface as per existing complete all as specified and directed. |
| 16 | Supply and fix in replacement of tubes \\"medium grade \\" of size 25 mm galvanised ISI marked with all fittings and fixed to walls and ceilings or laid in floors/trenches/under road including cutting and making the surface as per existing complete all as specified and directed. |
| 17 | Supply and fix in replacement of tubes \\"medium grade \\" of size 40 mm galvanised ISI marked with all fittings and fixed to walls and ceilings or laid in floors/trenches/under road including cutting and making the surface as per existing complete all as specified and directed. |
| 18 | Supply and fix in replacement of tubes \\"medium grade \\" of size 50 mm galvanised ISI marked with all fittings and fixed to walls and ceilings or laid in floors/trenches/under road including cutting and making the surface as per existing complete all as specified and directed. |
| 19 | S & F in replacement 20 mm dia CPVC pipes SDR-11 with all fittings and fixed to walls and ceiling or laid in floors complete all as specified and as directed. |
| 20 | S & F in replacement 25 mm dia CPVC pipes SDR-11 with all fittings and fixed to walls and ceiling or laid in floors complete all as specified and as directed. |
| 21 | Supply & fixing in replacement butterfly valve (Wafer Type), PN-1.6 with S/S Disc, neoprene rubber Lining, lever operated and S.G. Iron body suitable for 50 mm dia pipe complete all as specified and directed. |
| 22 | Supply & fixing in replacement butterfly valve (Wafer Type), PN-1.6 with S/S Disc, neoprene rubber Lining, lever operated and S.G. Iron body suitable for 65/80 mm dia pipe complete all as specified and directed. |
| 23 | Supply & fixing in replacement Non return butterfly valve suitable for 50 mm dia pipe complete all as specfied and directed. |
| 24 | Supply & fixing in replacement Non return butterfly valve suitable for 65 mm dia pipe complete all as specfied and directed. |
| 25 | Supply and fixing in replacement Pressure gauge 4\\"dial 0-14 kgs rating complete all as specfied and directed. |
| 26 | Supply and fix in replacement Foot Valve conforming to IS 4038, Made of cast iron material one side flange end and other side strainer and floating reinforced rubber coated ball as per exixting sample for 100 mm dia. complete all as specfied and directed. |
| 27 | Supply and fix in replacement Foot Valve conforming to IS 4038, Made of cast iron material one side flange end and other side strainer and floating reinforced rubber coated ball as per exixting sample for 150 mm dia. complete all as specfied and directed. |
| 28 | M&L for construction of 3mm thick MS Sheet cover fixed on 40mmx40mmx5mm thick angle iron frame embedded in PCC coping with locking arrangement and mild steel surface with one coat of red oxide primer and two coat of black paint etc. complete all as specified and directed. |
| 29 | M & L for making serviceable to UNSV Motor starter of any type carrying out repair and with replacement of defective minor spare parts such as, insulator, Terminal Block, copper thimbles, etc or if any other required minor spare parts at site for including testing to ensure efficient and smooth functioning of starter complete all as specified and directed.Note:- Defective major components/spares if required to be replaced shall be measured as supply under respective items. |
| 30 | S&F in repair MCB single pole with neutral, 6 to 32 Amps, 240 volts with ‘C’ curve complete all as specified and as directed. |
| 31 | S&F in repair MCB TP, 16 to 32 Amps, 240 volts with ‘C’ curve complete all as specified and as directed. |
| 32 | Supply and fixing in replacement MCCB of 25-100 Amps, 3 pole, 16KA with Adjuestable thermal setting suitable for 415 Volt, 50 Hz, in existing panel with suitable size lugs , nuts, bolts and washer etc complete all as specified and as directed. |
| 33 | S&F in replacement PVC insulated submersible flat cable ISI marked with multi stranded copper conductor 1100 volt grade of size 16 Sqmm 3 core complete all as specified and directed. |
| 34 | S&F in replacement PVC insulated, PVC sheathed, submersible flat cable ISI marked with multi stranded copper conductor 1100 volt grade of size 10 Sqmm 3 core complete all as specified and directed. |
| 35 | S&F in replacement PVC insulated, PVC sheathed, submersible flat cable ISI marked with multi stranded copper conductor 1100 volt grade of size 2.5 Sqmm 3 core complete all as specified and directed. Please Enable Macros to View BoQ information |
| 36 | S&F in replacement PVC insulated, PVC sheathed, submersible flat cable ISI marked with multi stranded copper conductor 1100 volt grade of size 2.5 Sqmm 3 core complete all as specified and directed. Please Enable Macros to View BoQ information |