Tender For Special Repairs To Roof Treatment In Building No P-158 , Xx , 10 , 16, 17 ,18 And P-154 At Ota Under Ge Stm Chennai
Tender Overview
Project Description
Tender for Special Repairs To Roof Treatment In Building No P-158 , Xx , 10 , 16, 17 ,18 And P-154 At Ota Under Ge Stm Chennai
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 17-Jun-2026 | Other Corrigendum2 | Other | 03-Jul-2026 |
| 2 | 17-Jun-2026 | Other Corrigendum | Other | 03-Jul-2026 |
| 3 | 17-Jun-2026 | BOQ Corrigendum | BOQ | 03-Jul-2026 |
BOQ
| Sl. No. | Item Description |
| 1 | Item Rate BoQ BoQ_Ver4.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) Tender Inviting Authority: COMMANDER WORKS ENGINEER,CHENNAI Ser.Page No: Name of Work: SPECIAL REPAIRS TO ROOF TREATMENT IN BUILDING NO P-158 , XX , 10 , 16, 17 ,18 AND P-154 AT OTA UNDER GE STM CHENNAI Contract No: CWE/STM/ OF 2026-27 Name of the Bidder/ Bidding Firm / Company : SCHEDULE 'A'(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # Sl.No. Description of items Item Code / Make Quantity Unit Estimated Rate Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency BASIC RATE In Figures To be entered by the Bidder Rs. P Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT With Taxes TOTAL AMOUNT With Taxes TOTAL AMOUNT In Words |
| 2 | Dismantling asbestos cement (corrugated, semi corrugated, etc.,) sheets as in roof coverings complete all as specified. |
| 3 | Dismantling framed work of timber scantlings 40 Sqcm and over in section and in any position complete all as specified. |
| 4 | Dismantling wrought iron or mild steel work of any description not otherwise provided for, complete all as specified. |
| 5 | M&L for second class hard wood in scantlings, timber framed and fixed, wrought complete all as specified. |
| 6 | All as per item No 04 above but except timber |
| 7 | S&F Mild steel roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc., conforming to Fe-290 (Grade E-165) complete all as specified |
| 8 | S&F mild steel hand rails, half round or other steel section, drilled and countersunk for balusters, wind ties for roof including securing bolts, posts and struts in fencing etc., conforming to Fe-290 (Grade E-165) complete all as specified. |
| 9 | S&F pre painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of required colour as approved by GE, having tensile strength of 550 mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as per Manufacturer's instruction and as specified |
| 10 | S&F pre painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick of required colour as approved by GE, having tensile strength of 550 mpa a in roof covering / cladding to wall, fixed with self tapping screws complete all as per Manufacturer's instruction and as specified |
| 11 | M&L for removing the existing roof treatment of any description completely and remove all the debris from site and rubbish off the premises ,clean the surface free from dust, dirt etc. complete all as specified and as directed. |
| 12 | M&L for screed bed 20 mm thick in cement mortar 1:4 mixed with water proofing compound and finish the surface even and fair to receive APP membrane complete all as specified and directed.Note: WPC shall be measured and paid separately under respective item. |
| 13 | M&L for APP Modified prefabricated five layer water proofing membrane, not less than 3 mm thick and weighing not less than 3.00 kg/Sqm reinforced with non woven polyester matt black finished over compatible primer @ 0.3 litres per Sqm, and a bonding bitumen of VG-10 at 1.20 kg/Sqm torching the membrane on whole surface uniformly while unrolling the membrane by LPG and sealed with trowel after necessary preparation of surface complete all as per Manufactures instructions and finally finished with a coat of bit mastic aluminium paint @ 0.10 litre/Sqm over a coat of blown bitumen 85/25 grade @ 1.20 Kg/Sqm over the membrane. The Over lap joint shall be provided of 75mm in longitudinal direction and 100mm in transverse direction respectively. All the angles, abutments and the drainage outlets shall be sealed with extra care to ensure full bondage complete all as specified and directed .Manufactures: IWL India Ltd/SAPL (ARGO-P) Hydrotech Ltd (Hydroflame) /STP.Note: The work shall be carried out by the authorized applicators of Manufacturers and necessary certificate shall be submitted by the contractor. |
| 14 | Dismantling wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/ blankets, any thickness, including cover fillets complete all as specified. |
| 15 | S&F Anodised aluminium snap grid of size 605mm x 605mm framework for false ceiling and 8mm thick exposed metal frame ceiling with calcium silicate board of siliceous and calcareous material reinforced with cellulose fibre for fixing in grid complete all as specified and directed |
| 16 | Demolition and breaking up drain pipes of 100mm internal dia and any type set in cement mortar complete all as specified |
| 17 | S&F PVC (SWR) pipes 110mm bore , single socketed, in any length with rubber ring joints or solvent cement, laid in trenches or in floors complete all as specified |
| 18 | S&F PVC (SWR) pipes 110mm bore , single socketed, in any length with rubber ring joints or solvent cement, fixed to walls complete all as specified. |
| 19 | S&F PVC (SWR) bend 110 mm bore. |
| 20 | S&F Mild stack clamps suitable fo 110mm bore of pipe made out of flat iron of size 50 mm x 5 mm and 16mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or roof complete all as specified. |
| 21 | Disconnecting existing tanks, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position. (Cleaning repairing, etc. measured separately), capacity of tank exceeding 500 litres but not exceeding 1000 litres complete all as specified. |
| 22 | S&F in repair rotational moulded polyethylene water storage tanks 500 litres capacity (cylindrical, vertical with closed top) three layered, hoisted and fixed in position complete all as specified in SSR Part I including 20mm Nipple (minimum weight 20mm-45gms) suitable for HDPE water tank, complete all as specified . |
| 23 | S&F in repair rotational moulded polyethylene water storage tanks 1000 litres capacity (cylindrical, vertical with closed top) three layered, hoisted and fixed in position complete all as specified in SSR Part I including 20mm Nipple (minimum weight 20mm-45gms) suitable for HDPE water tank, complete all as specified . |
| 24 | S&F in repair Ball valves high pressure of PTMT with epoxy coated Aluminium rod and high-density plastic ball screwed for iron pipe of 25mm dia & fixed complete all as specified (Minimum weight 25mm-455gms) |
| 25 | S&F in repair gun metal globe or gate valves with iron wheel head, screwed both ends for iron pipe of 25 mm dia & fixed complete all as directed. |
| 26 | S&F in repair gun metal globe or gate valves with iron wheel head, screwed both ends for iron pipe of 50 mm dia & fixed complete all as directed. |
| 27 | Taking up or down steel/iron tube of 20 mm bore and connections including cleaning for refixing or removal to store complete all as specified. |
| 28 | S&F CPVC pipes SDR 11& plain CPVC SDR 11 fittings on walls /ceiling or laying in floors of outer dia 20mmm complete all as specified. |
| 29 | Taking up or down steel/iron tube of 25 mm bore and connections including cleaning for refixing or removal to store complete all as specified. |
| 30 | S&F CPVC pipes SDR 11& plain CPVC SDR 11 fittings on walls /ceiling or laying in floors of outer dia 25mmm complete all as specified. |
| 31 | Taking up or down steel/iron tube of 50 mm bore and connections including cleaning for refixing or removal to store complete all as specified. |
| 32 | S&F CPVC pipes SDR 11& plain CPVC SDR 11 fittings on walls /ceiling or laying in floors of outer dia 50mmm complete all as specified. |
| 33 | Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided for, including removing debris from site complete all as specified. |
| 34 | Demolition of brick work built in cement mortar of any description including all precast concrete articles complete all as specified |
| 35 | M&L for PCC 1:2:4 type B0 using 12.50 mm graded stone aggregate, as in levelling course over the roof slab to receive roof treatment, complete all as specified. |
| 36 | M&L for brick work with fly ash bricks of old brick size, straight or curved on plan to any radius in brick thick walls, built in cement mortar 1:6 complete all as specified |
| 37 | M&L for reinforced cement concrete 1:2:4 type B1 using 20mm graded stone aggregate as in lintels upto 1.5m clear span on half brick partition wall including necessary form work as required etc. complete all as specified.Note : Reinforcement shall be measured and paid separately under relevant item. |
| 38 | M&L for providing reinforced cement concrete 1:2:4 type B1 using 20mm graded crushed stone aggregate as in slabs supported on walls, beams and columns in floors, roofs, landings, deck slabs and in shelves etc complete all as specified.Note: Reinforcement shall be measured and paid separately under relevant item. |
| 39 | M&L for use and waste of formwork to soffits of suspended slabs and connected beams and similar work, slab thickness not exceeding 200mm, fair finished surfaces of concrete complete all as specified. |
| 40 | M&L for Mild steel TMT bars 10mm dia and over ,of grade Fe 500,cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends & binding with & including mild steel wire (annealed) not less than 0.9mm dia or securing with clips quality complete all as specified. |
| 41 | M&L for Mild steel TMT bars 6mm to 8mm dia and over ,of grade Fe 500,cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends & binding with & including mild steel wire (annealed) not less than 0.9mm dia or securing with clips quality complete all as specified. |
| 42 | M&L for Mild steel TMT bars 5mm dia & over upto & including 10mm dia in stirrups, spacers & binders, cut to length, bent to shape required, binding with & including mild steel wire (annealed) not less than 0.9mmdia or securing with clips quality complete all as specified |
| 43 | Taking down cement plaster on brick or stone walls, etc., including raking out joints, hacking for key, scrubbing down with water etc. complete all as specified |
| 44 | M&L for rendering 15mm thick, first layer 10mm thick in CM 1: 6 and finishing layer 5mm thick in CM 1:4 mixed with water proofing compound to external wall surfaces and finished the surface even and smooth complete all as specified. |
| 45 | Supply only integral liquid water proofing compound. |
| 46 | M&L for complete removal of existing treatment on walls and applying two coats of oil bound distemper over a coat of primer over a coat of wall care putty to internal wall surfaces complete all as specified and as directed. |
| 47 | M&L for preparing new plastered wall surfaces and applying two coats of oil bound distemper over a coat of primer complete all as specified and directed. |
| 48 | M&L for preparation of old decorated ceiling surfaces, including providing necessary scaffolding, and applying one coat of white wash, including filling the cracks/depressions using chalk whitening wherever required complete all as specified. |
| 49 | M&L for complete removal of existing treatment from walls and applying two coats of exterior weather-proof paint over a coat of weather-proof primer to all external wall surfaces, complete all as specified and directed. |
| 50 | M&L for preparing old wooden surfaces of any description, over 10 cm in width or girth, not otherwise described and applying one coat of synthetic enamel paint, all as specified and directed. |
| 51 | M&L for preparing old steel surfaces of any description, over 10 cm in width or girth, not otherwise described and applying one coat of synthetic enamel paint all as specified and directed. Total in Figures 0.0 0.0 INR Zero Only 4.0 Construction of chamber for 100mm sluice plates item5 10.0 Nos Quoted Rate in Figures Select 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 1 dayCorrigendum-2 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 1 dayCorrigendum-3 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 1 dayBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 1 dayTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender