| 1 | Excavation in trenches in soft/loose soil not exc 1.5mtr wide and not exc 1.5 mtr in depth for laying of pipe line etc not exceeding 10 sqm on plan and not exceeding 1.5 m in depth and getting out complete all as specified and as directed. |
| 2 | Returning, filling in including spreading, levelling, watering and well ramming in layers not exc 25 cm thick in any type of soil complete all as specified and as directed. |
| 3 | Removing surplus excavated soil to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed. |
| 4 | Dismantling and taking out exisitng rusted/croded PVC/Cement pipe of size 150 mm bore of any length & type including with complete fitting bailing out water if necessary all as directed. |
| 5 | Dismantling and taking out exisitng rusted/croded PVC/Cement pipe of size 100 mm bore of any length & type including with complete fitting bailing out water if necessary all as directed. |
| 6 | Dismantling and taking out exisitng rusted/croded CI pipe of size 100 mm bore spigot and socketed ends of any length & type including burning of lead/rubber joints and bailing out water of necessary all as directed. Note for Sr item No- 4 to 9 :- Excavation and earth work shall be measured and paid sperately under item of Sch A. |
| 7 | Supply, laying and testing Ductile Iron pipes pressure with spigot & socket ends of 150 mm bore class K-7centrifugally cast confoRunning Metreing to IS:8329/2000 blast furnace slag cement portland cement properties suitable for push-on jointing with inside surface cement mortar lining, with internal metallic zinc coating and external black bitumen coating, duly ISI marked complete laid in trenches or under the roads, with and including tyton rubber gasket push-on joints as required at site complete all as specified and as directedMake: Electrosteel or techno equivalent make of Jindal/TATANOTE FOR SER ITEM NO. 7 to 8(a) Excavation & other earth work will be measured and paid separately under relevant items. |
| 8 | All as per ser item No. 7 above but for DI pipe of 100mm dia |
| 9 | Supplying & fixing DI special fitting in replacement of any size, type, radius, angle, tapers, increasing, decreasing sockets, tees, tail pieces and collars etc complete upto 200 mm dia |
| 10 | Taking out u/s rusted corroded PVC pipe of size 50 mm dia after cutting/unscrewing including all fittings from trenches /along walls/under roar etc complete all as specified and directed. |
| 11 | Taking out u/s rusted corroded PVC pipe of size 40 mm dia after cutting/unscrewing including all fittings from trenches /along walls/under roar etc complete all as specified and directed. |
| 12 | Taking out u/s rusted corroded GI pipe of size 25 mm dia after cutting/unscrewing including all fittings from trenches /along walls/under roar etc complete all as specified and directed. |
| 13 | Taking out u/s rusted corroded GI pipe of size 20 mm dia after cutting/unscrewing including all fittings from trenches /along walls/under roar etc complete all as specified and directed. |
| 14 | Taking out u/s rusted corroded GI pipe of size 40 to 50 mm dia after cutting/unscrewing including all fittings from trenches /along walls/under roar etc complete all as specified and directed. |
| 15 | Taking out u/s rusted corroded GI pipe of size 80 mm dia after cutting/unscrewing including all fittings from trenches /along walls/under roar etc complete all as specified and directed. |
| 16 | Supplying & laying and testing in replacement GI pipe 80 mm dia medium grade along with all fittings laid in trenches/wall along road icomplete all as specified and directed. |
| 17 | Supplying & laying and testing in replacement GI pipe 50 mm dia medium grade along with all fittings laid in trenches/wall along road icomplete all as specified and directed. |
| 18 | Supplying & laying and testing in replacement GI pipe 40 mm dia medium grade along with all fittings laid in trenches/wall along road icomplete all as specified and directed. |
| 19 | Supplying & laying and testing in replacement GI pipe 25 mm dia medium grade along with all fittings laid in trenches/wall along road icomplete all as specified and directed. |
| 20 | Supplying & laying and testing in replacement GI pipe 20 mm dia medium grade along with all fittings laid in trenches/wall along road icomplete all as specified and directed. |
| 21 | Material and labour for repalcement of gun metal gate valve (ISI marked) with iron wheel both ends screwed for iron pipe 50 mm bore including removing of defective gate valve complete all as specified and directed. |
| 22 | Material and labour for repalcement of gun metal gate valve (ISI marked) with iron wheel both ends screwed for iron pipe 40 mm bore including removing of defective gate valve complete all as specified and directed. |
| 23 | Material and labour for repalcement of gun metal gate valve (ISI marked) with iron wheel both ends screwed for iron pipe 25 mm bore including removing of defective gate valve complete all as specified and directed. |
| 24 | Material and labour for repalcement of gun metal gate valve (ISI marked) with iron wheel both ends screwed for iron pipe 20 mm bore including removing of defective gate valve complete all as specified and directed. |
| 25 | M & L for repair,rectifying and aresting the water leakage in already laid CI/DI pipe line of dia 200 mm dia including necessary excavation and earth work , bailing out stagnated /muddy water and providing CI D joint /lead wool etc complete to stop the leakage all as specified and directed by Eng-in-Charge. |
| 26 | All as per serial item No- 25 here-in-before but CI/DI pipe of size 150 mm dia -do-. |
| 27 | All as per serial item No- 25 here-in-before but CI/DI pipe of size 100 mm dia -do-. |
| 28 | All as per serial item No- 25 here-in-before but CI/DI pipe of size 80 mm dia -doNote for serial no. 25 to 28 - (i) Contractor will depute Labour/Pipe Fitter and other required equipments such as JCB etc to attend the leakage /complaint on daily basis as per complaint trace out and no extra payment made out on this account and directed by Engineer-in-charge. (ii) Complete site for attend the leakage can not be handed over to contractor ,Site of leakage only handed over the contractor on site requirement basis. (iii) Contractor/Supervisor will collect complaint of leakage from concern JE as daily basis and will complete same day. (iv) If leakage again found during the contract period at same location contractor will repair it again and no extra payment will be made on this account. (v) Contractor will provide equipments like JCB/tractor etc on his own arrangement for rectifying the complaint as per site requirement and no other payment will be made for the same. |
| 29 | M & L for repair/replacement for leakage of GI pipe line 50 mm dia incl bailing out of stagnated/muddy water till restore the water supply with replacement of necessary fittings such as elbows ,nipples union,reducers etc if required of GI pipe line upto 1 mtr as per site requirement including earth work such as excavation returning removal etc and all as specified and directed by Eng-in-Charge. |
| 30 | All as per serial item No- 29 here-in-before but GI pipe of size 40 mm dia -do-. |
| 31 | All as per serial item No- 29 here-in-before but GI pipe of size 25 mm dia -do-. |
| 32 | All as per serial item No- 29 here-in-before but GI pipe of size 20mm dia -do-.Note for serial no. 29 to 32 - (i) Contractor will depute Labour/Pipe Fitter and other required equipments etc to attend the leakage /complaint on daily basis as per complaint trace out and no extra payment made out on this account and directed by Engineer-in-charge. (ii) Complete site for attend the leakage can not be handed over to contractor ,Site of leakage only handed over the contractor on site requirement basis (iii) Contractor/Supervisor will collect complaint of leakage from concern JE as daily basis and will complete same day. (iv) If leakage again found during the contract period at same location contractor will repair it again and no payment will made on this account. (v) Contractor will provide equipments like JCB/tractor etc on his own arrangement for rectifying the complaint as per site requirement and no other payment will be made for the same. |
| 33 | Material and Labour construction of brick masonary valve chamber size 90 X90 X 90 cm (internal dimension) using sub class 'B' bricks complete including demolation of existing valve pit,earth work etc.type 'B' including PCC 1:5:10 type E-2 using 40 mm graded stone aggregate in foundation, coping on top in PCC 1:2:4 type B-2 using 20 mm graded stone aggregate ,inner plaster 10 mm thick in cm 1:4 MS sheet cover with locking arrangement duly painted with two coats of synthetic enamel paint over a coat of primer red oxide. |
| 34 | Supply and fixing in replacement 200mm dia sluice valve PN 1:0, ISI marked confiRunning Metreing to IS-14846, flanged and drilled, Steel spindle and iron wheel including jointing material such as nuts, bolts, washers and rubber sheet etc all directed by Engr-in-ChargeMake Kirloskar/Leader/L&T |
| 35 | Supply and fixing in replacement 150mm dia sluice valve PN 1:0, ISI marked confiRunning Metreing to IS-14846, flanged and drilled, Steel spindle and iron wheel including jointing material such as nuts, bolts, washers and rubber sheet etc all directed by Engr-in-ChargeMake Kirloskar/Leader/L&T |
| 36 | Supply and fixing in replacement 100mm dia sluice valve PN 1:0, ISI marked confiRunning Metreing to IS-14846, flanged and drilled, Steel spindle and iron wheel including jointing material such as nuts, bolts, washers and rubber sheet etc all directed by Engr-in-ChargeMake Kirloskar/Leader/L&T |
| 37 | Supply and fixing in replacement 80mm dia sluice valve PN 1:0, ISI marked confiRunning Metreing to IS-14846, flanged and drilled, Steel spindle and iron wheel including jointing material such as nuts, bolts, washers and rubber sheet etc all directed by Engr-in-ChargeMake Kirloskar/Leader/L&T |
| 38 | Supply and fixing in replacement 200 mm dia NRV, ISI marked confiRunning Metreing to IS-14846, flanged and drilled, including jointing material such as nuts, bolts, washers and rubber sheet etc all directed by Engr-in-ChargeMake Kirloskar/Leader/L&T |
| 39 | Supply and fixing in replacement 150 mm dia NRV, ISI marked confiRunning Metreing to IS-14846, flanged and drilled, including jointing material such as nuts, bolts, washers and rubber sheet etc all directed by Engr-in-ChargeMake Kirloskar/Leader/L&T |
| 40 | Dismantling of existing defective cast iron sluice valve 200 mm dia and repairing the same including replacement of Steel spindle with check nut, gate valve, ring , gland etc. testing and commissioning complete and re-fixing the same including replacement of worn out nuts, bolts gasket etc all as directed by the Engineer-in-Charge. |
| 41 | Dismantling of existing defective cast iron sluice valve 150 mm dia and repairing the same including replacement of Steel spindle with check nut, gate valve, ring , gland etc. testing and commissioning complete and re-fixing the same including replacement of worn out nuts, bolts gasket etc all as directed by the Engineer-in-Charge. |
| 42 | Dismantling of existing defective cast iron sluice valve 100 mm dia and repairing the same including replacement of Steel spindle with check nut, gate valve, ring , gland etc. testing and commissioning complete and re-fixing the same including replacement of worn out nuts, bolts gasket etc all as directed by the Engineer-in-Charge. |
| 43 | Dismantling of existing defective cast iron sluice valve 80 mm dia and repairing the same including replacement of Steel spindle with check nut, gate valve, ring , gland etc. testing and commissioning complete and re-fixing the same including replacement of worn out nuts, bolts gasket etc all as directed by the Engineer-in-Charge. |
| 44 | Material and Labour construction of brick masonary valve chamber size 120 X 120 X 120 cm (internal dimension) using sub class 'B' bricks complete including demolation of existing valve pit,earth work etc.type 'B' including PCC 1:5:10 type E-2 using 40 mm graded stone aggregate in foundation, coping on top in PCC 1:2:4 type B-2 using 20 mm graded stone aggregate ,inner plaster 10 mm thick in cm 1:4 MS sheet cover with locking arrangement duly painted with two coats of synthetic enamel paint over a coat of primer red oxide. Please Enable Macros to View BoQ information |
| 45 | Material and Labour construction of brick masonary valve chamber size 120 X 120 X 120 cm (internal dimension) using sub class 'B' bricks complete including demolation of existing valve pit,earth work etc.type 'B' including PCC 1:5:10 type E-2 using 40 mm graded stone aggregate in foundation, coping on top in PCC 1:2:4 type B-2 using 20 mm graded stone aggregate ,inner plaster 10 mm thick in cm 1:4 MS sheet cover with locking arrangement duly painted with two coats of synthetic enamel paint over a coat of primer red oxide. Please Enable Macros to View BoQ information |