| 1 | M & L cement concrete 1:2:4, type B-2 (using 40 mm graded stone aggregate) as, foundation and on road cutting hardstanding finishing even and smooth without using extra cement all as specified. |
| 2 | Cutting/demolition of cement concrete(un reinforced) /bitumen road n.exc 15 cm thickness (below or above ground level) and remove debris out side MD land all as specified |
| 3 | Supply and laying in replacement 300 mm bore spigot and socket ductile iron water tubing,class K-9,cement mortar lining on inner surface and one coat of bituminous paint over exposed surface ISI marked, IS No. 8329: 2000, including rubber joint of suitable size laid on roof/floor/trenches with proper alignment as per site requirement and carryout testing against leakage before filling the trenches etc complete all as specified and directed by Engr-in-Charge |
| 4 | All as per item No 3 but size 150 mm bore |
| 5 | All as per item No 3 but size 100 mm bore |
| 6 | Supply & fix in replacement sluice valve 150 mm size both ends flanged with high tensile stainless steel spindle, I body as per IS-14846, ISI Marked,PN-1.6 including all joints with rubber or fibre board, nuts, bolts, washers complete all as specified and directed. |
| 7 | Supply & fix in replacement sluice valve 100mm size both ends flanged with high tensile stainless brass spindle, I body as per IS-14846, ISI Marked,PN-1.6 including all joints with rubber or fibre board, nuts, bolts, washers complete all as specified and directed. |
| 8 | Supply & fix in replacement sluice valve 300 mm size both ends flanged with high tensile stainless steel spindle, I body as per IS-14846, ISI Marked,PN-1.6 including all joints with rubber or fibre board, nuts, bolts, washers complete all as specified and directed. |
| 9 | Supply and fixing in repair/ replacement of 40 mm dia internal steel water tubing, galvanised, Medium grade with all fittings such as nipple, union, socket, elbow, bends, fixed to wall including work to be done up to 15 th floor in high rise buildings in short piece/length, including breaking the existing brick wall for replacement of corroded GI pipe in/ on wall including concealed pipe and making good the disturbed surfaces to match previous structure with complete all as specified and directed by Engineer-in-charge. |
| 10 | All as per item No 9 but size 50 mm dia |
| 11 | All as per item No 9 but size 80 mm dia |
| 12 | Supply and fixing in replacemet of 40 mm dia Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed by Engr-in-Charge |
| 13 | All as per item No 12 but size 50 mm dia |
| 14 | All as per item No 12 but size 80 mm dia . Note : For item no 9 and 13 above rate deemed to be inclusive of provision of scaffolding and nothing extra will be payable to contractor on this account and after completion of work scaffolding shall be removed from the site and make good surfaces and site. |
| 15 | Construction of brick masonery valve chamber in repair of size 1.2 x 1.2 x 1.2 M (internal dimension) (above GL 0.30 mtr) suitable for fixing of sluice valves, 15cm thick foundation using PCC 1:4:8 type D-2 over 15cm thick hardcore of broken stone, 23cm thick brick walls built in cement and sand mortar 1:4, 15mm thick internal and external plaster including top of floor in cement and sand mortar 1:3, 15mm thick, finished even and smooth, without using extra cement, 5 mm thick plate cover on 50mm x 50mm x 6mm MS angle frame embeded in PCC 1:2:4 type B-1coping, having rectangular, hinged, opening of size 150 x 100mm with locking arrangements ,hold fasts, etc, applying one coat of red oxide primer and two coats of synthetic enamel paint to all steel surfaces and earth work in any type of soil including disposal of debris outside MD land complete all as specified. |
| 16 | Supply and fixing in replacement 100 mm ERW MS pipes including all fittings and specials as per IS 1239 & 3589 (1981) thickness 5.4 mm complete all as specified and directed by Engr-in-Charge |
| 17 | All as per item No 16 but size 150 mm dia |
| 18 | All as per item No 16 but size 300 mm dia but wall thickness 7.9 mm (minimum thickness). |
| 19 | Supply and fix , Installation, Testing & Commissioning in repair/replacement of Motor Actuated Butterfly Valve consisiting of Quarter turn single phase Actuator and Wafer type butterfly valve of size 300 mm dia with appropriate bracket/mounting arrangement including two nos. limit switches for open and closed condition and splash proof enclosure.Specifications & Features Input Voltage: 230 V, A.C. Designed line pressure: 10 kg/sq cm.Operating Angle: 90 degreesDisc Material: CI with nylon coatingLimit Switches : 02 Nos.For open and close status Mounting : Extended type with universal joint for installation 18-24 inches above ground level with angle mounting including raising of existing chamber as required at site. |
| 20 | All as per item No. 19 above but valve of size 150 mm dia |
| 21 | All as per item No. 19 above but valve of size 100 mm dia |
| 22 | All as per item No. 19 above but valve of size 50 mm dia |
| 23 | Supply & Fixing in replacement of 4C x 1.5 sq mm PVC sheathed and PVC insulated, armoured, FRLS, copper cable on wall/ laying in trench complete all as specified and as directed |
| 24 | Supply & Fixing in replacement of 6C x 1.5 sq mm PVC sheathed and PVC insulated, armoured, FRLS, copper cable. on wall/ laying in trench complete all as specified and as directed. |
| 25 | Supply and fix in replacement bitumen pachment on damaged road not exceeding 15 cm depth and make well ramming complete all as specified and directed |
| 26 | Supply and fix in replacement of 150 mm bore hand operated butterfly valve of pressure not less than 15 Kg / Sqcm with complete set. |
| 27 | Supply & fix in replacement Non return valve 150mm size both ends flayed with high tensile stainless steel spindle, I body including all joints with rubber or fibre board, nuts, bolts, washers complete all as specified and directed. |
| 28 | Supply & fix in replacement Non return valve 300 mm size both ends flayed with high tensile stainless steel spindle, I body including all joints with rubber or fibre board, nuts, bolts, washers complete all as specified and directed. |
| 29 | Supply and fix in replacement of CI foot valve 150 mm (6\\") dia ball type flanged end IS 4038 housing complete including replacement of nut bolts, cutting of pipe, welding complete all as specified and directed. Make :- Kirloskar/ Sant/Zoloto |
| 30 | M & L for Cutting existing DI pipes and reducing for insertion of DI fittings to required length in position for 300 mm bore complere all as directed. Note :- Pipe fittings used shall be measured and paid under relevant items of schedule 'A' remaining items like welding and other items required shall be deemed to be included in the item rate |
| 31 | All as per item No. 30 above but valve of size 150 mm dia |
| 32 | All as per item No. 30 above but valve of size 100 mm dia. |
| 33 | M & L in replacement for CI/DI specials conforming to IS - 1538& 9523, spigot /socket or flanged fitting I.e. bend, tee, collar, flanged/ socket /spigot, Tappers, flanges and tail pieces etc suitable for 100/150/300 mm bore CI/DI pipes (joints and joining material shall be measured and paid seperately) |
| 34 | Excavation in trenches not exceeding 1.5 mtr wide not exceeding 1.5 mtr in depth and getting out in soft/ loose soil all as specified. |
| 35 | Returning filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cms in any type of soil all as specified. |
| 36 | Removing excavated material exc 250m but n.exc 500m and depositing where directed all as specified. Please Enable Macros to View BoQ information |