Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Material and labour for repair, maint and making the continuity of supply after rectifying the defects of the electrical items such as tube light fittings,switches, replacement of fuse wires, distribution boards, MCB (light/power), lamp holders (bracket/ pandents/ batten), bell/buzzer, push button, ceiling rose, capacitors and other similar electrical items/fittings etc. including provisioning of small pieces of electrical wire of size 1 sqmm to 10 sqmm single core and length not exceeding 0.50 mtrs complete all as specified and directed by Engineer-in-Charge (Note :- (i) any accessories found unserviceable that shall be replaced under respective items of this Sch. Note : If complaint not completed within the same day then Rs 100/- of penalty will be recovered for per compalint/per day |
| 2 | Supply and fixing in replacement of LED lamp 07 to 15 watt watts 230 volts complete all as specified and as directed by Engineer-in-Charge. |
| 3 | Supply and fixing in replacement lamp holder suitable for LED lamp as per site requirement complete all as specified and as directed by Engineer-in-Charge. |
| 4 | Supply and fixing in replacement bell electric Ding Dong type 230 volts complete all as specified and as directed by Engineer-in-Charge. |
| 5 | Supply and fixing Switch piano flush button type single pole one/Two way/Bell push 5 amps 240 volts complete all as specified and as directed by Engineer-in-Charge. |
| 6 | Supply and fixing in replacement, for socket outlet 2 in 1, 5 pin, 5 Amps flush type complete all as specified and as directed by Engineer-in-Charge. |
| 7 | Supply and fixing in replacement, for switch flush type 15 Amps, 240 Volts single pole white finish complete all as specified and as directed by Engineer-in-Charge. |
| 8 | Supply and fixing in replacement of socket outlet 2 in 1, 3 pin, 5 & 15 A multi purpose flush type 240 V white finish complete all as specified and as directed by Engineer-in-Charge. |
| 9 | Supply and fixing in replacement of switch socket combination, 5 amps 5 pin flush type, 230 volts.white finish complete all as specified and as directed by Engineer-in-Charge. |
| 10 | Supply and fixing in replacement of switch socket combination, 5 and 15 amps multi purpose 5 in 1 flush type, 230 volts complete all as specified and as directed by Engineer-in-Charge. |
| 11 | Supply and fixing in replacement of switch Piano modular type, 6 Amp, one way complete all as specified and as directed by Engineer-in-Charge. |
| 12 | Supply and fixing in replacement of switch Piano modular type, 16 Amp, one way complete all as specified and as directed by Engineer-in-Charge. |
| 13 | Supply and fixing in replacement of bell push Piano modular type, 6 Amp, 230 volts complete all as specified and as directed by Engineer-in-Charge. |
| 14 | Supply and fixing in replacement of socket outlet modular type, 2/3 pin, 6 Amps, 230 volts complete all as specified and as directed by Engineer-in-Charge. |
| 15 | Supply and fixing in replacement ofsocket outlet modular type but 2/3 pin, 6/16 Amps, 230 volts complete all as specified and as directed by Engineer-in-Charge. |
| 16 | Supply and fixing in replacement of ceiling rose, surface backlite, 65 x 20 mm three terminal ISI Marked complete all as specified and as directed by Engineer-in-Charge. |
| 17 | Supply and fixing in replacement plastic laminated top sheet cover 3 mm thick of size 5\\"x5\\" all as required at site including drilling holes for fixing screws and providing 4 Nos screws with washers for fixing the sheet to sunken box /wooden box complete all as specified and as directed by Engineer-in-Charge. |
| 18 | All as per item no 17, but of size 8\\"x5\\" complete all as specified and as directed by Engineer-in-Charge. |
| 19 | All as per item no 17, but of size 11\\"x9\\" complete all as specified and as directed by Engineer-in-Charge. |
| 20 | All as per item no 17, but of size 13\\"x11\\" complete all as specified and as directed by Engineer-in-Charge. |
| 21 | Supply and fixing in replacement of PVC rectangular switch Board for mounting switches, sockets etc with 3mm thick plastic laminated sheet cover of size 100mmx100mm and 50mm deep , 240 volt complete all as specified and as directed by Engineer-in-Charge. |
| 22 | All as per item no 21, but of size 175mmx100mm and 50mm deep , 240 volt complete all as specified and as directed by Engineer-in-Charge. |
| 23 | All as per item no 21, but of size 200mmx150mm and 50mm deep , 240 volt complete all as specified and as directed by Engineer-in-Charge. |
| 24 | All as per item no 21, but of size 250mmx200mm and 50mm deep , 240 volt complete all as specified and as directed by Engineer-in-Charge. |
| 25 | All as per item no 21, but of size 350mmx300mm and 50mm deep , 240 volt complete all as specified and as directed by Engineer-in-Charge. |
| 26 | Material and labour for servicing of exhaust fan upto 300 mm sweep with painting and rewinding, change of bearing if defected, louvered/shutters including taking down and refixing after satisfactory repaired complete all as directed by Engr-In-Charge. |
| 27 | Material and labour for servicing of exhaust fan above 300mm and upto 450mm sweep with painting and rewinding, change of bearing if defect, louvered complete all as dorected by Engr-In-Charge. |
| 28 | Supply and fixing in replacement capacitor 3.15/4 mfd 240 volts for fans make Epcos /Matrix (oil Filled ) complete all as specified and as directed by Engineer-in-Charge. |
| 29 | Taking down and refixing/relocation of exising tube light fitting, wall bracket or bulkhead fitting including connecting electrically to ceiling rose using PVC insulated and overall sheathed flexible copper conductor cable of size 0.75 Sqmm 3 core all as per direction or specified by the Engr-in-charge |
| 30 | Supply and fixing in replacement of LED bulk head fitting Plastic Body , heat resistant, with specially designed gasket in and including LED lamp 10 watt complete all as per directed by Engr-in-charge. |
| 31 | Supply and fixing in replacement Polycarbonate LED lighting fixture of size 25 watt (4') complete with all accessories prewired and connecting electrically to ceiling rose using PVC insulated and overall sheathed flexible copper conductor cable of size 0.75 sqmm 3 core all as required at site or complete all as specified and as directed by Engineer-in-Charge. |
| 32 | All as per srl item No 31 here-in-before but 10 watt (2') complete all as specified and as directed by Engineer-in-Charge. |
| 33 | Supply and fixing in replacement of ultra mordern recess mounting flat panel luminaires (2'x2'), 36 Watt LED, 6000k with seprate electronic driver & high brightness SMD LEDs including lamp and complete with all accessories prewired and connecting electrically to ceiling rose using PVC insulated and overall sheathed flexible copper conductor all as required at site or complete all as specified and as directed by Engineer-in-Charge. |
| 34 | Supply and fixing in replacement energy saving flood light luminaire high power COB LED as light source with protection IP66 of 50 watt LED with inbuilt surge protection complete with all accessories pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and as directed by Engineer-in-Charge. |
| 35 | Supply and fixing Electronic Meter 10-60 amps Single phase tamper proof with Class 1 accuracy Optical port,LED Indication for earth leakage ,Elegant Polycarbonate Enclosure, anti tamper features, Electromagnetic compatible & 6 digit Display complete all as specified and as directed by Engineer-in-Charge. |
| 36 | Supply and fixing in repair/replacement voltage surge protector, 230/240 volts AC, 1.4 KV protection level type II with indicator double pole (two modules) with rupturing cacpacity 40 KA including makeing connection and providing thimble for out going cables and enclosure complete all as specified and as directed by Engineer-in-Charge. |
| 37 | Material and labour for testing of old earthing using calibrated earth tester & submitting result to engr -in -charge. Earthing which showing much more results as specified in IS rule and disconnetivity should be replaced with new earthing items are considered as below complete all as specified and as directed by Engineer-in-Charge.Note : (i) Watering of earthing with 2 Buckets (30Ltrs) water mixed with salt (total 5 Kg) shall be carried out one day before the testing & the cost of the same shall deemed included in unit rate quoted. |
| 38 | Taking down old unserviceable/deteriorated batten/PVC conduit point wiring from existing place i.e. light, fan, socket or power points complete with all unserviceable fittings such as switches, sockets, ceiling rose, pendants, Holders, etc and making good all disturbed surface to wall, floor etc by means of cement mortar (1 : 3) or plaster of Peris and to match / finish new surface as the existing surface either by using same colour distemper, Putti or white / colour wash all as required and directed by Engineer-in-Charge. |
| 39 | Taking down main switch/DB/ changeover/AC box of any capacity including fixing accessories of single/three phase complete all as specified and as directed by Engineer-in-Charge. |
| 40 | Taking down old/unserviceable aluminium/copper submain wiring off sizes complete all as specified and as directed by Engineer-in-Charge. |
| 41 | Material and labour for in replacement of concealed point wiring on wall and surface on ceiling/roof with necessary fixing arrangements with PVC-FRLS insulated and unsheathed copper multi-stranded conductor of size 1.5 Sqmm, 1100 volts grade drawn in and including rigid non metallic white / ivory PVC conduit medium grade ISI marked not less than 19 mm dia with all conduit accessories/ fittings such as junction boxes, bends, tee, elbow etc including anodized MS sunken boxes made out of MS sheet of thickness not less than 1.6 mm with earth dolly and Bakelite laminated sheet 3mm thick ISI marked for fixing of switches / sockets, fan regulators, wall mounting fittings, door bell & bulkhead etc with MS screw and cup washers including PVC-FRLS insulated and unsheathed copper multi-stranded conductor of size 0.75 Sqmm, 1100 volts grade for continuous earthing including cutting the chases and making good the surface by cement mortar (1:3) and for matching / finishing of new surfaces either by means of plaster of peris/ Putti or distemper / colour wash with same existing colour surfaces all as specified and directed by Engineer-in-Charge for the following:-(a) One light, fan, call bell, 5 Amp independent socket point controlled by one switch complete all as specified and as directed by Engineer-in-Charge. |
| 42 | All as per item No 41 but One socket point controlled by one switch on same board complete all as specified and as directed by Engineer-in-Charge. |
| 43 | All as per item No 41 here-in-before but for power point wiring with 2.5 Sqmm PVC-FRLS insulated, unsheathed, copper conductor, stranded 1100 volt grade cable and 1.5 Sqmm PVC-FRLS insulated, unsheathed, copper conductor, stranded 1100 volt grade cable as continuous earth lead complete all as specified and as directed by Engineer-in-Charge. |
| 44 | All as per item Srl No 41 here-in-before but point wiring in surface with casing & caping complete all as specified and directed by Engineer-in-Charge for the following:-(a) One light, fan, call bell point, 5 Amp independent socket point controlled by one switch complete all as specified and as directed by Engineer-in-Charge. |
| 45 | All as per item No 44 but One socket point controlled by one switch on same board complete all as specified and as directed by Engineer-in-Charge. |
| 46 | All as per item No 44 here-in-before but for power point wiring with 2.5 Sqmm PVC-FRLS insulated, unsheathed, copper conductor, stranded 1100 volt grade cable and 2.5 Sqmm PVC-FRLS insulated, unsheathed, copper conductor, stranded 1100 volt grade cable as continuous earth lead complete all as specified and as directed by Engineer-in-Charge. |
| 47 | Supply and fixing in replacement sheet metal enclosure , 32A single pole and neutral with a two pin and earth plug and socket complete in metal clad board (Industrial type) with one single pole MCB 20 Amp fixed properly complete all as directed by Engineer-in-Charge. |
| 48 | S&F in replacement sheet metal enclosure VTPN MCCB DB 4way, 415 V (vertical type) with bus bar double door type IP 43 - IK 09 for DB including MCBs & MCCB 100 Amps (as incomer) to be used, fixed properly on / in concealed position and to provide required sizes of flexible conduit at any open surfaces near DBs for cables/wires complete all as specified and as directed by Engineer-in-Charge. |
| 49 | Supply and fixing in replacement double door metallic sheet metal enclosure for DB when MCBs to be used TPNL, 4 ways, 415Volts (horizontal type) with 200 Amps rated bus bar suitable for TPN MCB/ 4 pole Isolator fixed properly on in concealed position and to provide required sizes of flexible conduit at any open surfaces near DBs for cables/wires complete all as specified and as directed by Engineer-in-Charge. |
| 50 | Supply and fixing in replacement double door metallic sheet metal enclosure for DB when MCBs to be used SPN 8 ways, 240 V with 200Amps rated bus bar complete fixed properly on in concealed position and to provide required sizes of flexible conduit at any open surfaces near DBs of cables/wires complete all as specified and as directed by Engineer-in-Charge. |
| 51 | All as per item no 50, but size 4 way complete all as specified and as directed by Engineer-in-Charge. |
| 52 | All as per item no 50, but size 2 way without busbar complete all as specified and as directed by Engineer-in-Charge. |
| 53 | Supply and fixing in replacement MCB SP 240 volt 6 Amp to 32 Amps 10 KA capacity having C-curve characteristics connected with suitable lugs complete all as specified and as directed by Engineer-in-Charge. |
| 54 | All as per item no 53, but SP 40-63 Amps complete all as specified and as directed by Engineer-in-Charge. |
| 55 | All as per item no 53, but SPN 16-40 Amps complete all as specified and as directed by Engineer-in-Charge. |
| 56 | All as per item no 53, but SPN 40-63 Amps complete all as specified and as directed by Engineer-in-Charge. |
| 57 | All as per item no 53, but TP 40-63 A 415 V complete all as specified and as directed by Engineer-in-Charge. |
| 58 | All as per item no 53,- but TPN 40-63 Amps complete all as specified and as directed by Engineer-in-Charge. |
| 59 | Supply and fixing in replacement heavy duty exhaust fan AC single phase 230/240 V of size 300 mm sweep 1400 RPM with louver & shutter including necessary grouting on wall complete and making good the wall surface after fixing of exhaust fan all as specified and directed by the Engr-in-charge. |
| 60 | Supply and fixing in replacement MCCB 100 Amps, 3 Pole, 415V, 25 KA, fixed type complete all as specified and as directed by Engineer-in-Charge. |
| 61 | All as per item no 60, but MCCB 125 Amps, 3 Pole, 415V, 25 KA, fixed type complete all as specified and as directed by Engineer-in-Charge. |
| 62 | Supply and fixing in replacement MCCB 160 Amps, 3 Pole, 415V, 36 KA, thermal, magnetic adjustable type complete all as specified and as directed by Engineer-in-Charge. |
| 63 | All as per item no 62, but MCCB 200 Amps, 3 Pole, 415V, 36 KA, complete all as specified and as directed by Engineer-in-Charge. |
| 64 | Material and labour for in replacement of sub main wiring with two single core PVC-FRLS insulated unsheathed multi stranded copper conductor cable of size 4 sqmm drawn in new/exisitng MS/PVC conduit with 4 Sqmm PVC-FRLS insulated unsheathed multi stranded copper conductor as a continuous earth wire complete excluding rigid PVC conduit complete all as specified and as directed by Engineer-in-Charge. |
| 65 | All as per item No 64, but size 6 sqmm complete all as specified and as directed by Engineer-in-Charge. |
| 66 | Material and labour for in replacement sub main wiring with four single core PVC-FRLS insulated unsheathed multi stranded copper conductor cable of size 6 sqmm drawn in new/existing PVC conduit with one run of 6 Sqmm PVC-FRLS insulated unsheathed multi stranded copper conductor as a continuous earth wire complete. Note for item No 64 to 65: New PVC Conduit & cutting chasing will be measured and paid separately under relevent item here-in-after |
| 67 | Materil and labour for replacement of Rigid metallic medium 20mm dia PVC conduit ISI marked in concealed position inclusive all fitting such as tee, bends, reducer, elbow, bell mouth, tube ends and all fixing accessories such as couplers lock, nuts, saddlers, pipe hooks etc fixed properly in concealed or surface position for laying of submain wiring or telephone wire etc all as specified and directed by Engineer-in-Charge |
| 68 | All as per item No. 67 above but metallic medium 25 mm dia PVC conduit ISI marked complete all as specified and as directed by Engineer-in-Charge. |
| 69 | Materil and labour for Cutting chases in brick walls, pinning in at the depth of 10cm, making good to facings where required and pointing in cement mortar 1:3 cutting chases for concealed conduit wiring and making good and plastering the surface with cement or plaster of peris and matching with same colour scheme, cutting not exceeding 10cm girth complete all as specified and as directed by Engineer-in-Charge. |
| 70 | Materil and labour for fixing Boxes junctions, plastic, round four terminals in existing/new PVC conduit fitting complete all as specified and as directed by Engineer-in-Charge. |
| 71 | Materil and labour for replacement of flameproof concealed point wiring on wall and surface wiring on ceiling / roof with necessary fixing arrangements with stranded PVC-FRLS insulated and unsheathed copper stranded conductor of size 1.5 Sqmm, 1100 volts grade drawn in and including 16 gauge stove enameled ERW rigid steel conduit (metallic) not less than 19 mm dia with all MS conduit accessories/ fittings such as, bends, tee, elbow excluding junction boxes etc including PVC-FRLS insulated and unsheathed copper stranded conductor of size 1.5 Sqmm, 1100 volts grade for continuous earthing including cutting the chases and making good the surface by cement mortar (1:3) and for matching / finishing of new surfaces either by means of plaster of peris/ Putti or distemper / colour wash with same existing colour surfaces all as specified and directed by Engineer-in-Charge for one light, fan point controlled by one switch complete all as specified and as directed by Engineer-in-Charge. |
| 72 | All as per item No 71 here-in-before but for power point wiring with 2.5 Sqmm PVC-FRLS insulated, unsheathed, copper conductor, stranded 1100 volt grade cable and 2.5 Sqmm PVC-FRLS insulated, unsheathed, copper conductor, stranded 1100 volt grade cable as continuous earth lead complete all as specified and as directed by Engineer-in-Charge. |
| 73 | Supply and fixing in replacement 16 Amp flame proof weather proof switch Socket and plug combined in LM 6 cable termination box, 250 V, 2P + Earth complete all as specified and as directed by Engineer-in-Charge. |
| 74 | Supply and fixing in replacement flame proof weather proof threaded type junction box LM 6 aluminium alloy complete all as specified and as directed by Engineer-in-Charge. |
| 75 | Supply and fixing in replacement flame proof weather proof metallic hose conduit 3/4 \\" dia 300 mm long complete all as specified and as directed by Engineer-in-Charge. |
| 76 | Supply and fixing in replacement flameproof double compression brass cable gland 3/4\\" dia complete with nipples complete all as specified and as directed by Engineer-in-Charge. |
| 77 | Supply and fixing in replacement Flame proof weather proof switch with cable termination in LM 6 cable termination box aluminium alloy housing 16 Amp, single pole 250 volts complete all as specified and as directed by Engineer-in-Charge. |
| 78 | Supply and fixing in replacement Fluorescent tube light fitting, 1x36 watt flameproof type FLP-WP IP-65 made of aluminium alloy LM6 with electronic ballast, bipen holders, connector block etc complete with all accessories prewired and includidnt connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and directed Make: Bajaj or equivalent in CG/ Sudhir/FCG./Shyam Switchgears Pvt ltd complete all as specified and as directed by Engineer-in-Charge. |
| 79 | Supply and fixing 5 Watt LED torch with high intensity focused beam with twin switching mode complete all as specified and directed by Engr-in-charge. Make : Havells Cat Part No. LHEXAOPFUN1G005 or equivalent complete all as specified and as directed by Engineer-in-Charge. |
| 80 | Supply and fixing in replacement 9 Watt, 6500 K LED round/oval slim compact aluminium die cast edge lit panel suitable for recess mounting round fixture with Opal diffuser and separate electronic driver complete all as specified and directed by Engr-in-charge. Make : Havells Cat part No. LHEBADP7IZ1W009 or equivalent complete all as specified and as directed by Engineer-in-Charge. |
| 81 | Supply and fixing in replacement LED panel drivers suitable for 9/12/15/18/36 watt recessed mounting luminaries with universal connectors complete all as specified and directed by Engr-in-charge. Make : Havells Cat part No. LSSLNW0171 or equivalent complete all as specified and as directed by Engineer-in-Charge. |
| 82 | Supply and fixing in 1100 volts grade heavy duty cable PVC insulated aluminium staranded conductor , served with inner sheathed PVC tape and overall PVC sheathed in service connection one twin core flat or circular of size 10 sqmm x 2core Material and labour |
| 83 | Material and labour for dismantling from insulators including taking down ACSR conductor any size from overhead lines complete all as specified and as directed by Engineer-in-Charge. |
| 84 | Material and labour for dismantling earth wire any size from eye hooks/insulators etc from overhead lines complete all as specified and as directed by Engineer-in-Charge. |
| 85 | Material and labour for dismantling insulator any type and any size from over head linescomplete complete all as specified and as directed by Engineer-in-Charge. |
| 86 | Supply and stringing ACSR conductor any size to over head lines, stretching properly to achieve proper sag including binding to insulators using GI/aluminium binding wire all as required at site or directed by Engr-in-Charge. |
| 87 | Supply and fixing in replacement of galvanized steel wire of size 4mm dia to over head line as continuous earth or fabrication of guarding cradles all as specified and directed by Engineer-in-Charge. |
| 88 | Material and labour for unbinding from insulators ACSR conductor any size of over head line for repairs. Restretching of ACSR conductor to achieve proper sag and rebinding to the insulators using aluminium/GI binding wire all as required at site or directed by Engineer-in-Charge. |
| 89 | All as per item srl No 88 above but GI wire complete all as specified and as directed by Engineer-in-Charge. |
| 90 | Material and labour for cutting/trimming tree branches around overhead lines to a distance of 01 meter both side from overhead lines or poles after taking proper shut down of electric supply from MES all as directed by Engr-in-charge. |
| 91 | Material and labour in replacement of Stay assembly set complete with accessories like stay rod/strand/plate ,loop type insulator, clamps, excavation, concreate etc for LT/HT pole any type using necessary T&P as required on site and as directed by Engineer-in-charge. |
| 92 | Material and labour in replacement of for pin type porcelain, vitreos, white, brown or green insulators including one galvanized mild steel spindle, two galvanised iron washers and one galvanised iron nut 100mm height, 65mm dia complete all as specified and as directed by Engineer-in-Charge. |
| 93 | Material and labour in replacement of for loop type insulator, vitreous porcelain white brown or green small size with overall dimensions 65x90mm, clearance of hole 16mm complete all as specified and as directed by Engineer-in-Charge. |
| 94 | Material and labour in replacement of for loop type insulator, vitreiys porcelain white brown or green large size with overall dimensions 90x140mm, clearance of hole 25.5mm complete all as specified and as directed by Engineer-in-Charge. |
| 95 | Supply and fixing in replacement of aluminium strip 25x3mm complete with saddles/ insulators made out of PVC or fibre and fixing screws for roof conductor/down conductor including welding or brazing for joints all as required at site or directed by E-In-Charge. |
| 96 | All as per item no 95 above but copper strip 20x3mm complete all as required at site or directed by E-In-Charge. |
| 97 | Supply and fixing in replacement of earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc as required 4mm dia galvanized iron or steel wire complete and all as specified and as directed by Engr-in-charge. |
| 98 | Supply and fixing in replacement outdoor intergal fantasy decorative LED bollard with IP protection 65 post top lantern suitable for landscape lighting in and including 08 watt LED with all complete fixing accessories and suitable arrangement as required at site complete all as specified and directed by Engr-in-charge. |
| 99 | Supplying including laying testing and connecting in replacement of XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured heavy duty electrical cable with aluminium conductor, 1100 volts grade, cross-sectional area with suitable lugs of following sizes:-(a) 16 sqmm 2 core complete all as specified and as directed by Engineer-in-Charge. |
| 100 | All as per item No 99.00 but 25 sqmm 2 core complete all as specified and as directed by Engineer-in-Charge. |
| 101 | All as per item No 99.00 but 35 sqmm 3.5 core complete all as specified and as directed by Engineer-in-Charge. |
| 102 | All as per item No 99.00 but 50 sqmm 3.5 core complete all as specified and as directed by Engineer-in-Charge. |
| 103 | All as per item No 99.00 but 70 sqmm 3.5 core complete all as specified and as directed by Engineer-in-Charge. |
| 104 | All as per item No 99.00 but 95 sqmm 3.5 core complete and all as specified and as directed by Engr-in-charge. |
| 105 | All as per item No 99.00 but 120 sqmm 3.5 core complete and all as specified and as directed by Engr-in-charge. |
| 106 | Material and labour for excavation in trenches in any type of soil, not exceeding 1.5m wide and not exceeding 1.5m in depth; for foundation, laying of cables and getting out complete all as specified & as directed by Engineer-in-charge. |
| 107 | Material and labour for returning, filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25 cm each layer complete all as specified & as directed by Engineer-in-charge. |
| 108 | Material and labour for removing excavated material not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified & as directed by Engineer-in-charge. |
| 109 | Material and labour for sand cushioning to under ground cable 8 cm thick layer below the cable and 15cm thick above the cable complete and complete all as specified & as directed by Engineer-in-charge. |
| 110 | Material and labour for brick protection with well burnt sub class ‘B’ brick a butting each other( width wise) across the cable laid in trenches complete all as specified & as directed by Engineer-in-charge. |
| 111 | Material and labour in replacement of tubing GI light grade 50 mm bore for cable protection laid in ducts, fixed to wall or poles including fixing arrangement all as required and directed by Engineer-in-Charge. |
| 112 | All as per srl item No 111 here-in-before but of size 40 mm bore complete all as specified & as directed by Engineer-in-charge.. |
| 113 | Supply and fixing in replacement of maintenance free battery 12 Volt , 150 AH dry type with suitable copper connecter terminal lead (positive and negative) for DG set 62.5 KVA complete all as spcified by Engr- In-Charge. |
| 114 | Supply and fixing in replacement of maintenace free battery 12 Volt , 180 AH, dry type with suitable copper connecter terminal lead (positive and negative) for DG set 82.5 KVA complete all as spcified by Engr- In-Charge. |
| 115 | Supply and fixing in replacement of portable one battery charger set to accommodate with copper connecting +ve/-ve lead terminal, voltage control regulator setector switch of 12 Volt, 24 V,36 V,current control regulator switch, amps meter, electronic fuse, push to reset , AC mains on/off buttons complete as factory made Make Autonic india or equvilent make all as specified by Engr-In-Charge. |
| 116 | Supply and fixing in replacement of neon indicater lamp set of three (RYB) PVC body with contact block and assembly to be fixed on exsisting panal board complete all as spcified by Engr- In-Charge. |
| 117 | Supply and fixing in replacement of PVC 1100 volt LT phase seperator/spacer for 3 phase 4 wire system incl taking down U/S seperater all as specified by E-in- Charge |
| 118 | Supply and fixing in replacement of PVC 1100 Volts LT phase seperator/spacer for 1 phase 2 wire system incl taking down u/s seperater all as specified by Engr-in- Charge |
| 119 | Supply and install in replacement ACB 4 Pole, 50 KA, 415 volt with thermal magnetic release, adjustable, manual fixed type of capacity 630 Amp complete all as specified and directed by Engr-in-Charge. |
| 120 | Material and labour for Danger Notice Plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with white letter, figures and conventional skull & bones in signal red colour and fixed with MS clamps, nuts and bolts of approved size, for LT, 20x15cm size complete all as specified & as directed by Engineer-in-charge. |
| 121 | Supply and fixing in replacement of single core copper multistrandred conductor flexible PVC Insulated heavy duty Industrial cable (unsheathed) 1100 volts size 16 sqmm ( per 100 RM roll) complete all as specified & as directed by Engineer-in-charge. |
| 122 | Supply and fixing in replacement of MCCB 4 Pole 415 Volts with rupturing capacity 16 KA 100 Amps fixed type complete all as specified & as directed by Engineer-in-charge. |
| 123 | All as per item no 122 above but 125 Amps fixed type complete all as specified & as directed by Engineer-in-charge. |
| 124 | Supply and fixing in replacement of MCCB 4 Pole 415 Volts with rupturing capacity 35/36 KA 160 Amps Adjustable type thermal Megnatic release complete all as specified & as directed by Engineer-in-charge. |
| 125 | Material and labour in replacement of earthing complete with galvanized cast iron earth plate electrode 600x600x6 mm thick buried directly in ground (Earth pit not less than 2.25 Mtr deep below ;normal ground level ) with top edge of earth plate not less than 1.5 Mtr below normal ground level connected to galvanized iron strip 32x6 mm as earth lead by means of bolts, nuts washers and check nuts of steel/GI duly protected with 40 mm bore light grade pipe upto main board , 20mm bore watering pipe light grade with CI/MS funnel and wire mesh including excavation , earth work in any type of soil and removing the surplus soil to a distance not exceeding 50 Mtr, add charcoal dust and common salt after mixing with BFC (Back Fill Compound) inadeqate quantity as recommended by the manufacturer or as diirectred by the Engr-in-charge all as shown in electrical plate No. 03 of SSR part-I 2009 having pit in PCC 1:2:4 type B-1 including angle iron frame made of angle iron of size 40x40x6mm grouted in PCC pit for CI cover of required size, funnel with wire mesh complete and all as specified and as directed by Engr-in-charge. |
| 126 | All as per item srl No 125 above but using GI wire 4mm thick complete all as specified & as directed by Engineer-in-charge.Note for item No 125 & 126 : If the earth result of the earthing found more than 4 Ohms then new earthing will be executed by the contractor without any extra cost for the result upto 4 ohms |
| 127 | Material and labour for dismentling taking out broken/worn out steel pole of 8.5 to 9.0 mtr long and kepping aside for refixing including conductor, insulator etc or carrying to store for credit complete all as specified & as directed by Engineer-in-charge. |
| 128 | Labour only for re-fixing of steel tubular swaged pole complete with cast iron base plate , painted internally with a coat of bituminous paint and externally one primer coat, one under coat and one finishing coat of aluminium paint as specified type (9 mtr long) with conductor and insulators complete all as specified & as directed by Engineer-in-charge. |
| 129 | Supply and fixing in replacement of Steel tubular swaged pole complete with cast iron plate, finial taper plug, bolts, nuts & screws as specified of type 410 SP-31 of 9 meter long including applying two coats of black bituminous paint throughout internally and externally up to the planting depth and remaining portion of the exterior painted with one coat of red oxide primer over two coats of aluminium paint and number marking on pole complete all as specified & as directed by Engineer-in-charge. |
| 130 | Material and labour for cement concrete in foundations, filling and mass concrete type D2 1:4:8 with 40mm graded aggregate for pole bedding. |
| 131 | Material and labour for cement concrete in foundations, filling and mass concrete type C2 1:3:6 with 40mm graded aggregate for foundation of pole complete all as specified & as directed by Engineer-in-charge. |
| 132 | Material and labour for cement concrete in foundations, filling and mass concrete type B2 1:2:4 with 40mm graded aggregate for coping of pole complete all as specified & as directed by Engineer-in-charge. |
| 133 | Material and labour for scraping of old paint from the steel tubular/PCC pole 09/11 mtr height with out removing accessories and preparation of surfaces for repainting. Repainting the pole with one coat of alternative black and yellow (existing colour) straps of 30 cm each upto 1.5 mtr height using synthetic enamel paint . Repainting the remaining pole and iron parts i.e U clamps, channels etc above 1.5 mtr height by applying one coat of aluminium paint including writing Pole Nos. with Black paint all as per specified at site and directed by Engineer-in-Charge. |
| 134 | Material and labour in replacement of earthing complete with copper earth plate 600x600x3.15 mm thick buried directly in ground (Earth pit not less than 2.25 Mtr deep below ;normal ground level ) with top edge of earth plate not less than 1.5 Mtr below normal ground level connected to copper strip 20X3 mm as earth lead by means of bolts, nuts washers and check nuts of copper/ bronze duly protected with 40 mm bore light grade pipe upto main board , 20mm bore watering pipe light grade with CI/MS funnel and wire mesh including excavation , earth work in any type of soil and removing the surplus soil to a distance not exceeding 50 Mtr, add charcoal dust and common salt as diirectred by the Engr-in-charge all as shown in electrical plate No. 03 of SSR part-I 2009 having pit in PCC 1:2:4 type B-1 including angle iron frame made of angle iron of size 40x40x6mm grouted in PCC pit for CI cover of required size, funnel with wire mesh complete and all as specified and as directed by Engr-in-charge. Note : If the earth result of the earthing found more than 1 Ohm then new earthing will be executed by the contractor without any extra cost for the result upto 1 ohm. |
| 135 | Supply and fixing in replacement of bus bar box suitable for 200 Amps load of size 450x325x214mm IP65 with internal 4 Nos Copper Strip 200A (30x10mm) and fixing in position with nut, bolt, clamp, disconnection and reconnection of service wire/UG cabel in box incl dismentling bus bar box at site complete and all as specified and as directed by Engr-in-charge. |
| 136 | Supply and fixing in replacement of street light pole box suitable for fixing on LT pole size 200x160x98 mm 25 sqmm Terminal block 4 Nos, 4 sqmm Earth terminal 1 No with suitable gland , door and locking arrangment and suitable for terminal single phase including MCB 6-10A SP and fixing in position with nut, bolt, clamp, disconnection and reconnection of service wire/UG cabel in box incl dismentling old street pole box complete all as specified & as directed by Engineer-in-charge. |
| 137 | Supply and fixing in replacement of onload change overswitch 125 Amps, 4 pole, 415 V including making necessary connections on wall/LT panels etc with suitable size of thimbles, cable glands and jointing material etc all as specified and directed by the Engr-in-charge. |
| 138 | All as per item no 137 above but 100 Amps, all as specified and directed by the Engr-in-charge. |
| 139 | Supply only PVC insulation LT tape of size 15M x 1.8cm x 0.125 mm complete all as specified & as directed by Engineer-in-charge. |
| 140 | Supply only EPR self amalgamating tape of size 38mm x 10 Mtr complete all as specified & as directed by Engineer-in-charge. |
| 141 | Material and labour for disconnecting the Split type Air conditioner cap 1.5/2 Ton from Outer unit and repair the followings as required on site & as directed by Eng-in-charge :-(a) Servicing the Split type AC cap 1.5/2 Ton, Cleaning of condenser coil unit from Stand and inner unit complete all as specified & as directed by Engineer-in-charge. |
| 142 | As per item no 141 here-in-before but Vacuum the compressor unit and testing of leakage and charging Gas of F-22 and topup the Gas F-22 complete all as specified & as directed by Engineer-in-charge. |
| 143 | As per item no 141 here-in-before but Replacement of capacitor 45 mfd. complete all as specified & as directed by Engineer-in-charge. |
| 144 | As per item no 141 here-in-before but Replacement of filter dryer complete all as specified & as directed by Engineer-in-charge. |
| 145 | As per item no 141 here-in-before but Replacement of sealed Comppresser Unit as per existing make as per sample complete all as specified & as directed by Engineer-in-charge. |
| 146 | As per item no 141 here-in-before but Taking out the defective eletronic circuit board or PCB unit indoor unit of split type AC and supply and fix eletronic circuit board for split AC of capacity 1.5 /2TR of any exixting make and model or as per required at site complete all as specified & as directed by Engineer-in-charge. |
| 147 | As per item no 141 here-in-before but Taking only burnt/unserviceable blower motor and replace the same with new (Company sealed) blower motor as per exiting size, specification and Make suitable for AC of capacity 1.5/2 Ton of any make and model as applicable and connectnig up all the system all as directed by the Engr-in-Charge |
| 148 | As per item no 141 here-in-before but Taking out unserviceable evaporator coil and replace the same with new (company sealed) evaporator coil as per size, secification and make suitable for Ac of 1.5/2 ton of any make & model as applicable and connecting up all system with and including charging of refrigment (F-22) and testing complete to the satisfaction of the Engr-in-Charge |
| 149 | As per item no 141 here-in-before but Taking out unserviceable condenser coil and replace the same with new(company new) condenser coil as per exiting size, secification and make suitable for Ac of 1.5/2 ton of any make as applicable and up all the system eith and including charging of refrigrant (F-22) and testing complete to the satisfaction of the Engr-in-Charge. |
| 150 | Material and labour for Disconnecting the Deep freezer cap 210/300 Ltr and refrigerator cap 165 to 310 Ltrs and repair the followings :-(a) Servicing the Refrigerator ,Deep freezer, Cleaning of condenser coil unit from Stand and inner unit complete all as specified & as directed by Engineer-in-charge. |
| 151 | As per item no 150 here-in-before but Taking out unserviceable condenser coil and replace the same with new(company new) condenser coil as per exiting size, secification and make suitable for refrigerator of capacity 180/310 ltrs of any make as applicable with and including charging of refrigerant gas (F-12) and testing complete to the satisfaction of the Engr-in-Charge. |
| 152 | As per item no 150 here-in-before but Vacuum the compressor unit and testing of leakage and charging Gas (F-12) complete all as specified & as directed by Engineer-in-charge. |
| 153 | As per item no 150 here-in-before but Replacement of capacitor or starting relay as suitable for existing capacity complete all as specified & as directed by Engineer-in-charge. |
| 154 | As per item no 150 here-in-before but Replacement of filter dryer pencil of any size complete all as specified & as directed by Engineer-in-charge. |
| 155 | As per item no 150 here-in-before but Replacement of cooling fan with electric motor complete all as specified & as directed by Engineer-in-charge. |
| 156 | As per item no 150 here-in-before but supply and fixing in replacement of compressor(sealed unit) as per existing size specification and make suitable for refrigerator of capacity 180/310 ltrs of any make as applicable and connecting up all the system with and including Relay & OLP and Re- gas charging of refrigerant and testing complete to the satisfaction of the Engr-in-Charge. |
| 157 | As per item no 150 here-in-before but refrigerator of capacity 310 ltrs of any make complete all as specified & as directed by Engineer-in-charge. |
| 158 | Material and labour for replacement of defective componants /accessories suitable for refrigerator of capacity 165 ltrs to 310 ltrs of any model and make as applicable and testing complete as directed by the Engr-in-Charge(a) Freezer complete with freezer door braket suitable for refrigerator of capacity 165 ltrs. |
| 159 | As per item no 158 here-in-before but suitable for 280 / 310 ltrs complete all as specified & as directed by Engineer-in-charge. |
| 160 | As per item no 158 here-in-before but Ice tray PVC / Plastic for all models complete all as specified & as directed by Engineer-in-charge. |
| 161 | As per item no 158 here-in-before but Chiller tray suitable for refrigerator of capacity 165 litrs complete all as specified & as directed by Engineer-in-charge. |
| 162 | As per item no 158 here-in-before but Thermostat control switch complete with knob and box suitable for refrigerator of capacity 165 ltrs to 310 ltrs complete all as specified & as directed by Engineer-in-charge. |
| 163 | Material and labour for replacement of unserviceable components/ parts such as power circuit board (PCB), time relay, socket outlet, regualtor /toggle switch,Voltmetre , Indicator lamp, circuit wiring fuse unit etc including rewinding of transfarmor &painting voltage stablizer extamally with two coats of synthetic enamal paint after preparation of old painted steel surface and testing all complete for stablizer up to 10 KVA capacity complete all as specified & as directed by Engineer-in-charge. |
| 164 | Supply and fixing in replacement heating element any type 1.5/2.0 KW 240 Volts, ISI marked for water heater storage type complete all as specified & as directed by Engineer-in-charge. |
| 165 | Supply and fixing in replacement thermostat switch 0 to 100°C , 240 volts suitable for water heater storage type any make complete all as specified & as directed by Engineer-in-charge. |
| 166 | Supply and fixing in replacemnent of Syphon assy any type for water heater storage type upto 25/50 ltr cap complete all as specified & as directed by Engineer-in-charge. |
| 167 | Supply and fixing in replacemnent of Inner copper tank any cap for water heater storage type upto 25/50 ltr cap complete all as specified & as directed by Engineer-in-charge. |
| 168 | Supply and replacement outer body suitable for 25/50 ltr geyser made out of MS sheet factory made complete with fixing bracket matching with existing complete all as specified & as directed by Engineer-in-charge. |
| 169 | Supply and replace glass wool of 25/50 ltrs capacity geyser complete all as specified and directed by Enginner-in-Charge. |
| 170 | Supply and replace indicator lamp round/square type suitable for geyser 25/50 ltr all as per sample AC 230 Volt complete all as specified & as directed by Engineer-in-charge. |
| 171 | Supply and replace hot and cold PVC connection 15mm dia complete with brass flair nuts at both ends complete all as specified & as directed by Engineer-in-charge. |
| 172 | Supply and replace brass pressure release valve chromium plated suitable for geyser 25/50 ltr capacity complete all as specified & as directed by Engineer-in-charge. |
| 173 | Supply and fixing anchor bolt 12mmX100mm long complete all as specified & as directed by Engineer-in-charge. (Note:- Anchor bolt shall be grouted with hammer drill only) |
| 174 | Supply and replace bottom cover plate of geyser of capacity 25/50 ltr complete with MS screw complete all as specified & as directed by Engineer-in-charge. |
| 175 | Supply and fixing in replacement Stop valve, cast copper alloy, screwed down,m high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions for bore dia of pipe 15mm complete all as specified & as directed by Engineer-in-charge. |
| 176 | Supply and fixing in replacement plug top 3 pin 6 amps AC 240 Volts complete all as specified & as directed by Engineer-in-charge. |
| 177 | Supply and fixing in replacement plug top 3 pin 16 amps AC 240 Volts complete all as specified & as directed by Engineer-in-charge. |
| 178 | Supply and fixing in replacement cord flexible PVC insulated and over all sheathed, 3 core, flexible copper conductor of size 1.50 sqmm, cut to size all as required at site complete all as specified & as directed by Engineer-in-charge. |
| 179 | As per item no 179 here-in-before but size 2.5 sqmm complete all as specified & as directed by Engineer-in-charge. |
| 180 | Supply and fixing in replacement cord flexible PVC insulated , 2 core, (22/0076) flexible copper strandred conductor of cut to size for connection ceiling rose to fittings and fixture complete all as specified & as directed by Engineer-in-charge. |
| 181 | S&F in replacement of building security light fitting new generation energy saving and environmental friendly long life LED street light made up of pressure die cast aluminium housing with high efficient LED as lighting source and PC cover having TOP Opening seperate driver compartment with IP66 protection and impact resistance of IK07 of 35 watt LED, 240 Volts incl bracket made out of GI pipe 25mm dia medium grade, 0.9 mtr long bent to shape with welded MS flat 25 x 6 mm for mounting of fitting & MS flat iron clamps made out of 25mmX 6mm thick FI nuts, bolts complete all as specified and directed by the Engr-in-charge. |
| 182 | Supply and fixing in replacement energy efficient flame froof , heavy duty high speed exhaust fan 380 mm (15\\") sweep, with louver shutter, matel body rust proof inbuilt safety grill, single phase 230 volts 50 Hz AC, totally enclosed heavy duty motor with die cast alumn rotor mounted on two ball bearings complete with louvers & shutters,, including making circular holes suitable for fixing of 380mm sweep exhaust fans by cutting the wall any thickness/ required circumstances for exhaust of air and including grouting of rag bolts and nuts complete including finishing of disturbed surfaces by using cement mortar 1:3 complete and connecting electrically using 3 core 0.75sq mm PVC insulated flexible copper conductor cable over all sheathed all as required at site and directed by the Engineer-in-Charge. |
| 183 | S&F in replacement of Gyser including installation and testing of ISI marked, energy efficient, water heater storage type made of ultra-thick super cold rolled steel plates, incoloy glass-coated heating element offering superior heating performance, electrically operated, single phase, 50 Hz (BEE 5 star rating), complete of 25 Ltr capacity suitable to withstand 8 bar pressure with whirlflow technology and adjustable knob for convenient setting of temperature with and including supply and fixing, wire armoured 450 mm long, 15 mm dia brass coupler etc, flexible pipe suitable to withstand upto 100 degree celcius for hot and cold water, anchor fastner - 04 Nos of suitable size, 3 core PVC insulated, FRLSH multistranded copper conductor cable and plug top 15 Amps capacity complete in all respect all as specified and directed by Engr-in-Charge. Note : Old unserviceable geyser is to be deposited to MES store yard. |
| 184 | Supply and fixing in replacement of carbon fiber heating element 1000 watt , 240 volt, suitable for existing heat piller make gopi/belco or equvilent complete all unit all as directed by Eng-in-charge . |
| 185 | Material and labour for repair of central air heating plant complete fitted with AHU humididfier including repair/ replacment the following unserviceable/defective spares/parts including testing of the same after satisfactorily repaired :-(a) Finned strip heaters for fast heat transfer as per existing capacity & sample =10 Nos(b) Repair of pump spray and nozzle blower =01 Nos(c) Replacement of defective ducting diffuser of suitable size as per existing required as per site(d) Re-winding of motor pump set of cap 1/2 HP =01 No(e) Thermostate as per the existing capacity =01 No(f) Micron filter 0.5mm of size 130x60cm =06 Nos |
| 186 | Material and labour for scraping out existing wornout disifigured paint from the super structure of Air heating plant with the help of sand/empry paper or blow lamp and re-painting the superstructure with two coat of anti-rust superior quality synthetic enamelled paint over one coat of red oxide primer complete all as specified and directed by Engr-in-charge |
| 187 | Material and labour for replace duct insulation with resin bonded fibre glass wool roll of density 24 kg/cum with factory laminated aluminium vapour barrier thickness of insulation as specified and including the following :(a) M&L for cleaing the duct surface (to be insulated) by scrapping carefully with wire brush etc to make the surface completely free of millscale dirt, dust, grease and other foreign materials, taking special care so that all duct joints are sealed against any leakage(b) M&L for applying rubber based adhesive CPRX compound (c) M&L for sealing of all longtitudinal joints and circular overlaps with and including aluminium foil tape 50mm wide, to make the insulation leakproof(d) M&L for securing the insulation with and including mechanically fastened nylon/steel straps of size 12mm/50mm at maximum intervals of 1.2mtr |
| 188 | Material and labour for complete servicing of 11 TR package AC plant complete in all respect including servicing of Indoor /Outdoor Unit with filters, copper fins and cleaning the entire unit complete all as specified & as directed by Engineer-in-charge. |
| 189 | Material and labour for repair of 11 TR Packaged AC outdoor unit including repair/ replacment the following unserviceable/defective complete all as specified & as directed by Engineer-in-charge.(a) expansion valve |
| 190 | All as per item No 190 but Drier filter complete all as specified & as directed by Engineer-in-charge. |
| 191 | All as per item No 191 but Vacuum the compressor unit and testing of leakage and charging Gas of refrigment (R 407C) and testing complete all as specified & as directed by Engineer-in-charge. |
| 192 | All as per item No 190 but Belt A28 complete all as specified & as directed by Engineer-in-charge. |
| 193 | All as per item No 190 but Outdoor Motor with fan blade complete all as specified & as directed by Engineer-in-charge. |
| 194 | All as per item No 191 but Indoor Motors complete all as specified & as directed by Engineer-in-charge. |
| 195 | All as per item No 190 but Compressor 11 TR complete all as specified & as directed by Engineer-in-charge. |
| 196 | Supply, mixing and filling of Mono Ethylene Glycol in the ration of 60:40 (water & Glycol) along with the necessary additional and inhibitor in congnition and supplied in barrels. The mixture freezing temperature shall be (-) 25 deg C, all as specified & directed by Engr-in-charge Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail