| 1 | Complete removal of existing treatment on wall of old decorated surfaces of wall including cornices etc by scrapping machine tools/electric hand grinder with wire brush and applying two or more coats of 100% premium acrylic emulsion paint having VOC less than 50 grams/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/10 Sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 Sqm over a coat of 1mm thick wall care putty complete all as specified and directed. |
| 2 | M&L for preparation of old decorated surface of walls and applying one coat of white wash on wall complete all as specified and directed. |
| 3 | M&L for preparation of old decorated surface of ceiling and applying one coat of white wash on ceiling complete all as specified and directed. |
| 4 | M&L for preparing old decorated surfaces of wall applying one coat of oil bound distemper white or with 1 mm thick one or two coat of wall care putty at necessary surfaces complete all as specified and directed. |
| 5 | M&L preparation of old decorated surface of wall and applying one coat of cement base paint complete all as specified and directed. |
| 6 | M&L for preparation of old painted surface of wooden work and applying one coat of synthetic enamel paint on surfaces of any description exc 10 Cm width or girth with paint sprayers complete all as specified and directed. |
| 7 | M&L for preparation of old painted surface of steel surfaces (previously decorated) painting with one coat of synthetic enamel paint on old steel surfaces for grills, guard bars, shutters etc complete all as specified and directed. |
| 8 | Taking down cement plaster on brick or stone walls including wall tiles etc with raking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed. |
| 9 | M&L for rendering 15mm thick in CM 1:6 on fair faces of brick work or concrete surfaces even & smooth complete all as specified and directed. |
| 10 | M&L for rendering 15mm thick in CM 1:4 on fair faces of brick work or concrete surfaces with WPC complete all as specified and directed. |
| 11 | M&L for rendering 3 mm thick in CM 1:3 on ceiling surfaces of RCC or brick complete all as specified and directed. |
| 12 | Supply only Liquid Water Proofing Compound (ISI marked) complete all as specified and directed. |
| 13 | Preparation of newly plaster surface of wall and applying two coats of oil bound distemper over a coat of primer complete all as specified and directed. |
| 14 | Preparation of newly plaster surface of wall and applying two coats of cement base paint including one coat of primer complete all as specified and directed. |
| 15 | Preparation of newly plaster surface of wall and applying two coats of white wash on wall complete all as specified and directed. |
| 16 | Preparation of newly plaster surface of ceiling and applying two coats of white wash complete all as specified and directed. |
| 17 | Demolition of brick work built in cement mortar of any description including all quions arches, pillars etc complete all as specified and directed. |
| 18 | M&L for brickwork with sub class 'B' bricks, straight or curved on plan exc 6 mtr mean radius built in CM 1:4, complete all as specified and directed. |
| 19 | Taiking up or down steel tubing and connections, 15mm bore complete all as specified and directed. |
| 20 | Taking up or down steel tubing and connections, 20mm bore complete all as specified and directed. |
| 21 | Cutting chases in brick walls, pinning in, making good to facings where required and pointing in cement mortar 1:3 for concealed water tubings, cutting not exceeding 10 cm girth complete all as specified and directed. |
| 22 | M&L for GI tubing 15mm bore 'medium grade' galvanised with all fitting and fixed complete to walls and ceilings or laid in floors complete all as specified and directed. |
| 23 | M&L for GI tubing 20mm bore 'medium grade' galvanised with all fittings and fixed complete to walls and ceilings or laid in floors complete all as specified and directed. |
| 24 | Taking down rain water / vent pipe of any description including fittings etc including removal to store, complete all as specified and directed. |
| 25 | S&F PVC (SWR) pipes 110mm bore single socketed in any length with rubber ring joints fixed to wall or laid in floors, complete all as specified and directed. |
| 26 | S&F PVC (SWR) pipes 75mm bore single socketed in any length with rubber ring joints fixed to wall or laid in floors, complete all as specified and directed. |
| 27 | S&F 110mm bore PVC (SWR) bends of any radius provided without access door, complete all as specified and directed. |
| 28 | S&F 75mm bore PVC (SWR) bends of any radius provided without access door, complete all as specified and directed. |
| 29 | S&F 75mm bore stack clamps out of 50mm by 5mm flat iron and 16mm dia round iron stays, including securing ends of stays to wall or roof complete all as specified and directed. |
| 30 | S&F 100mm bore stack clamps out of 50mm by 5mm flat iron and 16mm dia round iron stays, including securing ends of stays to wall or roof complete all as specified and directed. |
| 31 | S&F in repairs Gun Metal Gate Valve 20mm bore, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed. |
| 32 | Dismantling Water Tanks capacity exc 250 ltrs but not exc. 500 ltrs complete all as specified and directed. |
| 33 | S&F rotational moulded polyethylene water storage tanks white colour tripple layers with thread type locking cover arrangement, 500 ltrs (cylindrical vertical with closed top) hoisted and fixed in position complete all as specified and directed. |
| 34 | S&F in repair rotational moulded polyethylene water storage tank of capacity 1000 ltrs (Cylindrical/Vertical with closed top) double layer construction, ISI marked hoisted and fixed in position including dismantling of old tank and removing from site complete all as specified and directed. |
| 35 | S&F Ball Valves high pressure with polythene float and fly nut complete, screwed for iron pipe 20mm bore or brass ferrule and fixed complete all as specified and directed. |
| 36 | Hacking out old broken glasses of any thickness size and quality from wooden or steel window glazed with putty or fixed with beads including punching or drilling out old glazing pins/clips etc complete all as specified and directed. |
| 37 | S&F 3mm thick sheet glass ordinary quality in square not exceeding 0.5 Sqm in each pane new door / window shutter complete all as specified and directed. |
| 38 | Dismantling of stone slab and tiles of any description or thickness laid bedded and pointed in any mortar in floor, wall, aprons etc complete all as specified and directed. |
| 39 | M&L for Granite 16mm to 17mm thick (of any type) work (table rubbed and polilshed) in steps, jambs, pillars, window-cills, cooking platforms and like in cement mortar (1:4) including pointing in wite cment (1:2) using marble dust with admixture of pigment to match with shade of granite over 15mm thick screed bed in cement mortar 1:6 complete all as specified and directed. |
| 40 | M&L for wall cladding tiles of size 300mm x 600/300mm x 450mm x 7-8 mm thick designer type coloured for wall etc set and jointed in cement and pointed in coloured cement to match the shade of tile and over 15mm thick rendering in CM (1:4) on brick work or concrete surface on wall and finished the even and fair to receive tiles complete all as specified and directed. |
| 41 | Demollition of cement concrete reinforced of any description and in any position complete all as specified and directed. |
| 42 | Dismantling of AC Sheet corrugated/semi corrugted sheets in wall cladding or in roof covering complete all as specified and directed. |
| 43 | M&L Prepainted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws complete all as specified and directed. |
| 44 | Dismantling structural steel work including doors, gates but excluding framed trusses etc complete all as specified and directed. |
| 45 | M&L for structural steel work with rolled mild steel sections as in main and cross beams, hip and jack rafters, purlins where connected to common rafters and running rails and guides for sliding doors, fixed with angle cleats or other connecting plates conforming to Fe-290 (Gde E-165) quality 'A' complete all as specified and directed. |
| 46 | Schedule of Credit (MINUS) Rs. 10,600.00 B/F from Serial Page No. ____ [Note : Details of items for schedule of credit is given on Srl Page No. ___ ] This amount shall be automatically deducted to arrive at tendered sum Please Enable Macros to View BoQ information |