| 1 | Excavation in trenches not exc 1.5 M wide and not exc 1.5 M in depth for pipe line, etc in soft/ loose soil getting out and levelling of bottom surface to required level all as specified and as directed. |
| 2 | Returning filling in, including spreading, leveling, watering and well ramming in layers not exc 25 Cm thick soft / loose soil all as specified and as directed. |
| 3 | Removing excavated material (Soils) from site to a distance not exc 50 M away and depositing where directed at a level not exc 1.5mtr above the starting point all as specified and as directed. |
| 4 | Boring holes under road pavement by bocky manually in any type of soil upto 200 mm bore complete all as specified and directed by Engr-in-Charge. |
| 5 | Supply, laying jointing, testing of DI pipe with class-K-7 spigot socketed ends, conforming to IS-8329 laid in trenches including providing route indicators of suitable height and laying at spacing of @ 50m center to center at GL mentioning name of contractor, date of execution & CA No with name of work & rubber gasket (Tyton) joints with jointing material & route indicators of the following sizes including taking down of existing CI/DI pipe complete all as specified and directed by Engineer-in-Charge. Note 1: - Excavation & earth work shall be measured and paid seperately under respective items of BOQ.Note 2:- Contractors will provide route indicators mild steel body with top 150 mm plate 3mm thick and height not less than 300mm above finished GL at suitable intervals as directed by EIC. Cost of route indicators shall be deemed included in quoted unit rates.Note 3:- DI pipe whole quantity of tender shall be procured by contractor in one time from the authorised dealer of approved make and PV's, MTC & e-way bill will produced by contractor during payment of 1st RAR as material laying at site.Note 4:- Piece meal site for laying of pipe shall be given by EIC and contractor arrange to transport the DI pipe accordingly at his own arrangement. No any additional payment for transportation will be given to contractor. Contractors are requested to quote rate accordingly.Note 5:- Layout plan for laying of DI pipe shall be given by EIC in writing.Note 6 :- Cost of Rubber gasket joints (Tyton Joint) included in quoted unit rates. |
| 6 | 80 mm bore |
| 7 | 100 mm bore |
| 8 | 150 mm bore |
| 9 | 200 mm bore |
| 10 | Material and Labour for DI fittings/specials such as Tees, bends (any type, radius and angle) tapers any type, collars, tail pieces, caps and plugs upto 200 mm dia sizes confirming to IS: 9523 complete all as specified and directed by Engr-in-Charge. |
| 11 | Supplying, laying, jointing, welding & testing in replacement MS Pipe (Heavy duty class 'C') laid in trenches or on floors for connections to centrifugal pump sets for suction, pump to header and to connect out going water main CI/DI pipe line all as directed by Engr-in-Charge. Note:- MS Flanges and Flange joints complete with jointing materials is deemed to be included in this items unit rate |
| 12 | 80 mm bore |
| 13 | 100 mm bore |
| 14 | 150 mm bore |
| 15 | Supply, fixing, jointing & testing in replacement Cast Iron Sluice Valve of following size, ISI Marked, flanged ends drilled pressure rating PN-1.0, PD Short body, having stainless steel spindle with cast iron operation wheel at top complete all as specified and as directed at site by the Engr-in-Charge. Note:- Flanged joints complete with jointing material shall deemed to be included in the unit rate of this item. |
| 16 | 80 mm bore |
| 17 | 100 mm bore |
| 18 | 150 mm bore |
| 19 | Supply, fixing, jointing and testing in replacement Cast iron Non Return valve without by pass arrangement, swing type, flanged ends pressure rating PN 1.0 complete all as specified and as directed at site by the Engr-in-Charge. Note:- Flanged joints complete with jointing material shall deemed to be included in the unit rate of this item. |
| 20 | 80 mm bore |
| 21 | 100 mm bore |
| 22 | 150 mm bore |
| 23 | Supply and fixing CI foot valve flanged ends, swing type opration with rubber sheet, as per IS:4038 including taking out unsv foot valve all as specified and directed by Engr-in-Charge. Note:- Flanged joints complete with jointing material shall deemed to be included in the unit rate of this item. |
| 24 | 150 mm bore |
| 25 | Supply, installation and testing of flanged ends water meter ISI marked woltman type, Class 'B' of following sizes and making good connection with flanged ends, with gasket rubber sheet and nut & bolts fixing in horizontal/inclind/vertical position, including taking out unsv water meter complete all as specified and directed at site by the Engr-in-Charge. Note :- Flange joints including jointing materials shall deemed to be included in the unit rate of this item. |
| 26 | 100 mm bore |
| 27 | 150 mm bore |
| 28 | Supply, laying, fixing, jointing In Replacement of GI Pipes 'medium grade' with all Fitting such as bends, socket, elbow etc complete all as specified and directed |
| 29 | 15 mm bore |
| 30 | 20 mm bore |
| 31 | 25 mm bore |
| 32 | 40 mm bore |
| 33 | 50 mm bore |
| 34 | Supplying & fixing gun metal gate valves with iron wheel head, screwed both ends for iron pipe, ISI Marked, as per IS: 778 of following sizes including taking out unsv gate valves complete all as specified and as directed at site by the Engr-in-Charge. |
| 35 | 15 mm bore |
| 36 | 20 mm bore |
| 37 | 25 mm bore |
| 38 | 40 mm bore |
| 39 | 50 mm bore |
| 40 | Material and labour for PCC (1:3:6) type C-2 (using 40 mm graded stone aggregate) as in foundation of brick pillar including demolition of old PCC and removing the debris from site complete all as specified and as directed at site by the Engr-in-Charge. |
| 41 | Material and labour for Brick work with sub class 'B' bricks straight or curved on plan built in CM (1:4) as in brick pillar of required size and shape including demolition of old brickwork & removing from site all as specified and as directed at site by the Engr-in-Charge. |
| 42 | Material and labour for rendering 10 mm thick with cement mortar (1:6) on fair faces of brick work / concrete surfaces, finished the surface even and fair complete all as specified and directed by Engr-in-Charge. |
| 43 | Taking out sluice valve, foot valve, refacing, regrinding, rubber gasket changes, stem nut, stem plate, nuts & bolts and refixing the same serviceable condition with flange joints including nut, bolt and double washers of following sizes all as specified and directed by Engr-in-Charge. |
| 44 | 80 mm bore |
| 45 | 100 mm bore |
| 46 | 150 mm bore |
| 47 | Supply, installation and testing in replacement flanged ends strainer/dirt box of following sizes with stainless steel mesh suitable for cold water meter to avoid foreign material entering into meter and making good connection with flanged ends, with gasket rubber sheet and nut & bolts fixing in horizontal/inclind/ vertical position, complete all as directed at site by the Engr-in-Charge. Note :- Flange joints including jointing materials shall deemed to be included in the unit rate of this item. |
| 48 | 100 mm bore |
| 49 | 150 mm bore |
| 50 | An amount of Rs 2,57,535.00 shall be deducted from BOQ on account of schedule of credit Please Enable Macros to View BoQ information |