| 2 | Earth work in excavation in foundation trenches in ordinary soil ( vide classification of soil item A) and disposal of excavated earth as obtained to a distance upto 50M including all lifts leveling ramming the foundation treanches, removing roots of trees, and shrubs all complete as per approved design, building specification and direction of E/I. |
| 3 | Extra for earthwork in hard soil as per specification and direction of E/I. ( vide classification of soil item-B) |
| 4 | Earth filling in foundation trenches and plinth in layers not exceding 150 mm thick well watered, rammed, fully compacted and fine dressed with earth obtained from excavation of foundation trenches within a lead of 50 M and lift of 1.5 M all complete as per building specification and direction of E/I. (mode of measurement compacted volume) |
| 5 | Earthwork in backfilling structures in layers not exceeding 150mm thick with previous or semipervious or suitable soil from borrow pits free from logs, roots, or any other ingredients by manual excavation and carraige by truck with all lifts including watering ramming, fully compacted and finely dressed, complete job as per specification and direction of E/I.BEYOND 1/2KM but upto 1 km. |
| 6 | Providing coarse clean sand in filling in in foundation trenches or in plinth including ramming and watering in layers not exceeding 150mm thick with all leads and lifts including cost of all materials labour, royalty and taxes all complete as per building specification and direction of E/I (Mode of measurement compacted volume) |
| 7 | Providing designation 75B one brick flat soling joints filled with local sand including cost of watering taxes royalty all complete as per building specification and direction of E/I. |
| 8 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:3:6 (1 Cement : 3 coarse sand (zone-III): 6 graded stone aggregate 40 mm nominal size) |
| 9 | Providing RCC M200 with nominal mix of (1:1.5:3) infoundation and plinth with approved quality of stone chips 20mm to 6mm size graded and clean coarse sand of FM 2 to 3 including screening, shuttering mixing cement concrete in mixer and placing in position, vibrating striking , curing (but excluding the cost of reinforcement) ,taxes and roylity all complete as per building specification and direction of E/I |
| 10 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size). |
| 11 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mmnominal size) |
| 12 | Centering and shuttering including strutting, propping etc. and removal of form forFoundations, footings, bases of columns, etc. for mass concrete |
| 13 | Suspended floors, roofs, landings, balconies and access platform |
| 14 | Lintels, beams, plinth beams, girders, bressumers and cantilevers |
| 15 | Columns, Pillars, Piers, Abutments, Posts and Struts |
| 16 | Providing designation 75B brick work in C.M (1: 6) in superstructure with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10mm thick mortar, joints cost of screening materials raking out joints to 15mm depth , curring , taxes and royalty all complete as per builiding specification and direction of E/I. |
| 17 | Providing 12mm thick water proof cement plaster (1:3) with clean coarse sand of F.M. 1.5 with 5% cico or any other approved water proofing compound including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I. |
| 18 | Finishing with Epoxy paint (two or more coats) at all locations prepared andapplied as per manufacturer's specifications including appropriate priming coat,preparation of surface, etc. complete.On concrete work |
| 19 | Providing 12mm cement plaster (1:6) with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I. |
| 20 | Providing 6mm Thk. Cement plaster (1:4) in ceiling with clean coarse sand of F.M 1.5 -do- |
| 21 | Providing and applying fibre reinforced elastomeric liquid water proofing membrane with resilient acrylic polymers having Sun Reflectivity Index (SRI) of 105 on top of concrete roof in three coats @10.76 litre/ 10 sqm. One coat of self-priming of elastomeric waterproofing liquid (dilution with water in the ratio of 3:1) and two coats of undiluted elastomeric waterproofing liquid (dry film thickness of complete application/system not less than 500 microns). The operation shall be carried out after scrapping and properly cleaning the surface to remove loose particles with wire brushes, complete in all respect as per the direction of Engineer-in-Charge. |
| 22 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade:New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) |
| 23 | Providing and fixing pressed steel door frames conforming to IS: 4351,manufactured from commercial mild steel sheet of 1.60 mm thickness, includinghinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25 mm, or base ties of 1.60 mm, pressed mild steel welded orrigidly fixed together by mechanical means, including M.S. pressed butt hinges 2.5 mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-charge:Profile CFixing with adjustable lugs with split end tail to each jamb |
| 24 | Supplying, fitting and fixing 35mm thick solid core type decorative single leaf flush door shutter with both side decorative veneered with black core bended with high quality phenol formal dehyde synthetic resin of standard make with aluminium fittings such as hinges, tower bolts,handles cleatas and sand blocks and taxes all complete as per building specification and direction of E/I. |
| 25 | Providing Tor steel reinforcement of 10mm,12mm,& 16mm. dia bars as per approved design and drawing exclusive carriage of M.S. bars to work site, cutting, bending and binding with annealed wire with cost of the wire, removal of rust, placing the rods in position all complete as per building specification and direction of E/I. |
| 26 | Supply of structural steel. |
| 27 | Labour for fabricating, erecting, hoistion and fixing in position structrral steel work in R.S. Joist, channel, Angle, Tee, flat, plate, latice member, built up compound section in column, girder, stair case, or truss including cost of gusset plates, holding down bolts, anchor plates at all heights and depths, bolting, welding ( machining wherever necessary) with applying a priming coat of red lead paint all complete as per approved drawing, building specification and direction of E/I. |
| 28 | Electrical work |
| 29 | Supplying submersible pump sets confirming to IS 8034 and motor confirming to IS 9283 Pump shall be suitable for various delivery head and discharge with stainless steeel pump shaft and polypropylene/ noryl impeller. Motor suitable for working on 145V+10% , 3PH, 50Hz, AC supply with cable guard, thrust water proof winding shall be provided. The pump set shall be suitable for direct coupling. Pump shall have suitable outlet as per manufacturers design. Anti thrust stream lined non return valve shall be provided with pump. 3 meter submersible copper conductor cable in single/ double run shall be provided with each pump.5.0 HP |
| 30 | D.O.L. starter with SS Enclosure with 380/415 volt coil 10HP |
| 31 | S/F S.P. MCB DB:-Supplying & fixing following way single pole neutral, sheet, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper busbar, neutral busbar, earth bar, din bar, detachable gland plate,interconnections, phosphatized & powder painted including earthing etc. as required. (But wihtout MCB/RCCB/Isolator)8 way, Double Door |
| 32 | 50/63 amps ratting, SP MCB \\"C\\" series 10 ka breaking capacity |
| 33 | laying of one no. pvc insulated & pvc sheathed/ XLPE power cable of 1.1 KV grade of size exceeding 950sq mm but not exciding 185 sq mm direct inground including exacavation, sand cushion, protection covering and refilling the trenches etc. as required |
| 34 | S/F PVC/ G.I Boxes:-Supplying & fixing PVC/ G.I box of following sizes on surface or in recess withsuitable size of phenolic laminated sheet cover infront including painting etc. ad required.210 mm x 206 mm x 48mm deep / (10\\" x 12\\") |
| 35 | S/F Piano type switch/ socket:-Supplying & fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required.3 pin 5/6 amps, socket outlet |
| 36 | S/F Modular boxes, base & cover plate - Supplying and fixing following size/modules G.I. box along with modular base & cover plate for modular switches in recess etc. as required. 1 or 2 module (78mm x 78mm x 45mm) |
| 37 | Point wiring in PVC conduit, with pino type switch:-wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FR PVC insulated copper conductor singal core cable in surface/ recessed PVC conduit with piano type switch, phenolic laminated sheet, suitable size PVC/G.I box ect. asGroup B |
| 38 | Circuit/submain wiring in PVC conduit:-Wiring for circuit /submain wiring along with earth wire the fillowing sizes of FR PVC insulated copper conductor single core cable in surface recessed PVC conduit as required.4 x 4.0 sq.mm + 2 x 2.5 sq.mm earth wire |
| 39 | Circuit / Sub Main wining in PVC Conduit:Wiring for circuit/ sub-main wiring along with earth wire with the following size of PVC insukated, copper conductor, single core cable in surface/ recessed PVC conduit as required.4x6 sq.mm + 2x 6 sq.mm earth LDBs |
| 40 | Circuit / Sub Main wining in PVC Conduit:Wiring for circuit/ sub-main wiring along with earth wire with the following size of PVC insukated, copper conductor, single core cable in surface/ recessed PVC conduit as required.4x10sq.mm + 2x 6 sq.mm earth LDBs |
| 41 | Installation. Testing & Commissioning of the 7 Mtr. Octagonal Pole & light fitting with the help of suitable tools and plants, and construction of shallow foundation with the help of suitable tools and plants, and construction of shallow foundation with M25 grade concrete considering safe soil bearing capacity of 10T/mtrs Sq. but excluding wire and MCB. |
| 42 | Swaged steel tubular pole (410SP-2) of height 7 Mtr. Confirming to IS 2713 (Part II) in three section with steel base size, bottom of the pole made of 50 mm dia MSB Clamp pipe welded to 300 mm long MS canopy of suitable dia at an angle of 102.5 suitable size of nuts and bolts including rating of one coat of steel primer and two coat of lead-oxide all complete as required. |
| 43 | Single Arm 1 metre long |
| 44 | 60W LED Street light |
| 45 | 20/22W LED Tube light |
| 46 | 15\\" (380mm) metal exaust fan |
| 47 | NP2 RCC Hume pipe with collar as per I.S.S 458:1971 (vi) 450mm dia |
| 48 | Labour for laying, fitting and fixing NP2 RCC Spun pipe with collars in line, level and grade and providing approved jointing materiala and joints properly filled to make them leak, proof including providing sight rails, bonning rod, night guard, red light and barrier etc. all complete as per specification and direction of E/I.450 MM dia R.C.C Spun pipe Upto 3.0 m depth of invert below GL. |
| 49 | Supplying of ISI mark HDPE . pipe of following class and dia. excluding GST and including Royality etc. and hire charges of P&M (with pol) procured from DWSD Jharkhand .90 mm.HDPE for Main Pipe line |
| 50 | supplying labour and tools for laying and jointing HDPE pipes in trenches and making butt welded joint, supplying heating mirror, jack etc. nad proveding night guard, barrier -do-do. 90 mm.HDPE for Main Pipe line |
| 51 | Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc.80 mm. for Branch Pipe line |
| 52 | Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc.50 mm. for Branch Pipe line |
| 53 | G.M Non ReturnValve Vertical (ISI Marked) (ix) 100mm dia wt. not less than 1.80kg |
| 54 | G.M Non ReturnValve Horizontal (ISI Marked) (ix) 100mm dia wt. not less than 1.80kg |
| 55 | G.I. Fittings (Comfirming to IS -1879)(ix) 100mm |
| 56 | HCI Pipe (IS : 1729)(s)100mm dia single socket 1'-0\\" (with ear weight 7.60 kg) |
| 57 | DI Pipe : Providing and Supplying ISI mark Centrifugally cat (Spun) Ductile Iron Pipes of 100 mm and avobe all diameter for water works with socket & spigot ends confirming -do-100mm dia |
| 58 | HCI Fitting (IS :1729) Plain Bend 100mm dia (weight without ear and socket 3.5kg) |
| 59 | Bend with Door 100 mm dia -do- 5.5kg |
| 60 | CARRAIGE OF MATERIAL |
| 61 | Aggregate |
| 62 | Cement |
| 63 | Steel |
| 64 | METAL |
| 65 | Bricks |
| 66 | NON SCHEDULE ITEMS |
| 67 | Aeration Machine Surface floating Areator for STP air flow rate 5-100 cum/hour |
| 68 | SLUICE GATEStainless Steel Sluice Gate, for Waste WaterProduct SpecificationMaterial -frame Cast Iron leaf S/SUsage/Application - Sewage/ Waste Water / EffluentMOC Cast Ironcapacity 1 MLD - 100 MLDType Channel / Thimble Mount |
| 69 | 13 Mtrs Clarifloculator-1 set-gear train with PP wheel for mechanical assembly, 1 set- SS 304 Rake arms on bridge1 set- of scraper SS 304 blades with neoprene squeezes1 MSEP Bridge walkway including checkered plated-4mm1 set of pipe-32nb for railings on bridge1 Weir plate for clarified water collection in FRPControl panel- DOL starter on clarifer bridge.Motor 1.0 hp crompton/ABB/Kirloskar with 1440 RPMGear: Double reduction geared system with final drive gearBridge size 8.2m x1.0mFinal RPH 3-4 |
| 70 | Installation and commissioning of Clarifloculator |
| 71 | Operation and Maintinence of 5 MLD Sewage Treatment plant As per Table 5.3 Part 'C': chapter 5 Of CPHEEO, including cost of labour, operator, mechanic, J.E, energy and consumables, reparing and regular maintinence of machine with replacement of necessary spare parts all complete for 3 years |
| 72 | Add GST @18% |
| 73 | Add Labour Cess @1% Please Enable Macros to View BoQ information |