| 1 | Supplying and fixing of of factory tested, direct connected type 3 phase 4 wire Digital energy meter of rating 20-100 amp, accuracy class-1.0, suitable for operation on 230/240V (P-N), 400/415V (P-P), 50 Hz+5% AC supply, operating temperature range from +55 deg C to -10 Deg C, protection class of IP-51 compliance to IS-13779, IEC-62052-11 and IEC-62053-21 with provision for sealing of mains and terminal covers, etc.as reqd. (Make & Model: SECURE SPRINT-350/equivalent model of L&T) |
| 2 | S/F of energy meter box suitable3phase 20-100A energy meter with locking arrangement and transparent sheet for meter reading i/c fixing on wall & making good the damages etc complete as reqd. |
| 3 | Supplying of 3.5x35sqmm PVC insulated PVC seathed Al conductor armoured cable for extension of 3phase power supply etc as reqd. |
| 4 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. |
| 5 | Up to 35sqmm |
| 6 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. |
| 7 | Up to 35sqmm |
| 8 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size Up to 35sqmm in the existing Duct/Air as required. |
| 9 | Up to 35sqmm |
| 10 | Replacement of damaged MV cable end terminations with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. |
| 11 | 3.5 X 35 sq. mm |
| 12 | Cutting the concrete road up to 10-12'' depth and 8.0mtr long for laying of cable & making goods damages with ciment concrete etc complete as reqd |
| 13 | Dismantling the existing old 1.5TR split AC units(indoor & Out door units) from its position & Shifting of the same etc.complete as reqd. |
| 14 | Installation , testing , & commissioning of 1.5 TR Split A.C. Unit , mounting / Fixing of indoor & outdoor unit ,fixing of refrigerant piping with expanded polythene foam insulation, laying of cable for interconnections and laying drain pipe of standard length which is supply along with AC unit, minor civil work i/c making holes on wall for laying refrigerant pipe lines, control cable and drain pipes and closing the extra openings with cement sand, making good the damages etc. as reqd.(Extra length of Refrigerant piping & cable shall be paid extra) |
| 15 | Dismantaling of the following electrical equpments after disconnection of LT cables/connection etc complete as required. |
| 16 | 1/2x40 box/SMO Lifght fitting &1200/1400mm sweep Ceiling Fans & Compoutor boards etc as reqd |
| 17 | S/F following rating TPN SDFU with HRC fuse, 415 Volts ,50Hz, complete with connection, testing & commissioning etc as reqd. a) 100 Amps (Make- Havells) |
| 18 | Supplying and laying of 40mm dia HDPE pipe of PN 8 for protection of cable complete as required.( Make : Oriplast /SS ) Please Enable Macros to View BoQ information |