| 1 | Supplying and fixing of following sizes of FRLS (ISI) PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required-20 mm |
| 2 | Supplying and fixing of following sizes of FRLS (ISI) PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required-25 mm |
| 3 | Supplying and fixing of following sizes of FRLS (ISI) PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required-32 mm |
| 4 | Supply and drawing of 25 mm SWR reinforced Flexible Conduit Pipe. |
| 5 | Supply and fixing of 50mm X 50mm UPVC Mini Trunking along with Eternal Angle / Flat angle / Internal angle/T joints/ end caps and fasteners in complete as required including labour charges etc., |
| 6 | Supply and fixing of 32mm X 12.5mm UPVC Mini Trunking long with Eternal Angle / Flat angle / Internal angle/T joints/ end caps and fasteners in complete as required including labour charges etc., |
| 7 | Wiring for light point/exhaust fan point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS/HFFR PVC insulated copper conductor single core cable etc as required. |
| 8 | Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS / HFFRPVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS /HFFR PVC insulated copper conductor single core cable etc. as required . |
| 9 | Supply, Installation, Testing and Commissioning of ceiling fan 1200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum)with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal (Aluminum alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit,safety rope, copper winding, steel/Al body Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS :374-2019), THD (Total Harmonic Distortion) less than 10%,suitable for operation with regulator for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Ceiling Fan compliant to IS 374:2019 fan Supply, earthing etc. complete as req |
| 10 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 11 | Supplying and fixing 1 or 2 Module (75mmX75mm) , GI box/PVC along with modular base & cover plate for modular switches in recess etc. as required. |
| 12 | Supplying and fixing following 5/6 A switch modular switch on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 13 | Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required. |
| 14 | Supply and fixing of Anchor fastner with fan hook / Providing MS Fan hook with grouting and cement plastering. |
| 15 | Supply and transportation of 22W +/ 10% , >/ 2300 lumens, 1200 mm (+/- 10%) length LED light housing made with alluminium anodised body, wide operating voltage with PF≥0.9, Surge protection: > 2KV, THD<15%, with inbuilt driver and frosted cover CCT: 3000K - 6500K as desired by the department as per IS, minimum CRI≥80 etc., complete with 5 years warranty with BIS Certification with BIS Certification. |
| 16 | Supply and Transportation of 30-36 W +/-10% (>=3600 Lumens) Back lit, 2' x2' (600mm x 600mm) Recessed / Surface mounted LED luminaire made of CRCA sheet housing with powder coated with high efficiency acrylic wide diffuser, with wide operating voltage range, Power factor > 0.9, Surge protection >2KV, System efficacy of >100 lumens/watt, CCT: 3000K - 6500K as desired by the department, CRI >80, and THD is less than 15% etc., complete with 5 years warranty with BIS Certification. |
| 17 | Supply and transportation of 60 / 65 W +/-10% (>=6500 Lumens) LED Street light Body made of high grade pressure die – cast Aluminium alloy with corrosion resistant powder coat, having protective toughened glass cover / temperature protective custom molded polycarbonate diffuser, Thermal shock and impact resistant IK07 fixed to the housing by SS screws Suitable lense on LEDs, Less Glare, IP 66 (Silicon gasket ensures Optical & Electrical compartments are IP 66) protected, wide operating voltage range, P.F > 0.90, System having efficacy >120 lumens / watt, with Ingress protection IP66, BIS approved Potted driver, Driver surge protection >10KV, THD<15%, CCT: 3000- 6500K as desired by the department and as per IS, CRI>70, Inbuilt Electrical protections like Over voltage, short circuit, Over load, Open Circuit, Miswiring, etc complete with BIS certification with 5 years warranty. The contractor has to furnish the manufacturer warranty letter, LM 79 and LM 80 certificates. |
| 18 | Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types and ceiling fans/wall fans complete with all accessories and tube etc. directly on ceiling/ wall, including connection with 1.5 sq. mm FRLS /HFFR PVC insulated, copper conductor, single core cable and earthing etc. as required. |
| 19 | Supplying and drawing of FRLS/HFFR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 20 | Supplying and drawing of FRLS/HFFR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 21 | Supplying and drawing of FRLS/HFFR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 22 | Supplying and drawing of FRLS/HFFR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 2 X 6 sq. mm + 1 X 6 sq. mm earth wire. |
| 23 | Supplying and drawing of FRLS/HFFR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 4 X 6 sq. mm + 1 X 6 sq. mm earth wire. |
| 24 | Wiring for circuit/ submain wiring alongwith earth wire with the 4 X 10 sq. mm + 2 X 6 sq. mm earth wire sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required (including Conduit). |
| 25 | Wiring for circuit/ submain wiring alongwith earth wire with the 4 X 16 sq. mm + 2 X 6 sq. mm earth wire earth wire sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required (including Conduit). |
| 26 | Supply and drawing of 1.5 Sqmm 3 core PVC / XLPE Insulated Sheathed Multi Core Bright Annealed Bare Copper Conductor Heavy Duty Industrial Cables for Voltage Grade upto 1100 Volts as per IS: 694:2010 including all transportation charges in the existing surface/ recessed steel/ PVC conduit as required. etc., complete. |
| 27 | Supply of 12\\" (300mm) , 900 RPM Heavy duty exhaust fan with metallic blades. |
| 28 | Supply of 15\\" (375mm) , 900 RPM Heavy duty exhaust fan with metallic blades. |
| 29 | Extra for fixing the louvers/ shutters complete with frame for a exhaust fan of all sizes. |
| 30 | Installation of exhaust fan Upto 450 mm sweep in the existing opening, including making good the damage,WPC board of suitable size , connection, testing, commissioningetc. as required |
| 31 | Cutting holes of required size in brick masonry wall for fixing of exhaust fan including providing and fixing 300 mm dia PVC pipe conforming BIS-12818 and making good the same etc. complete as per direction of Engineer-in-charge. |
| 32 | Supplying and fixing 12 way, Double door, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) |
| 33 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) -4 way (4 + 12), Double door |
| 34 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) -8 way (4 + 24), Double door |
| 35 | Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 volts, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 amps tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCB’s (but without MCB’s and incomer ) as required-4 way (4 + 12), Double door . |
| 36 | Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 volts, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 amps tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCB’s (but without MCB’s and incomer ) as required -12 way (4 + 36), Double door. |
| 37 | Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required-Single Pole. |
| 38 | Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required-Double Pole. |
| 39 | Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required-Triple Pole. |
| 40 | Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required-Triple pole and Neutral. |
| 41 | Supplying and fixing 63 A, four pole, 415 V, MCB in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 42 | Supplying and fixing of \\"63 A Triple Pole rating 415V 10kA\\" \\"C \\" Curve,Minature circuit breaker suitable for inductive load of TP in the existing MCB DB complete with connections testing and commisioning etc as required. |
| 43 | Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc.asrequired-40A. |
| 44 | Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc.asrequired-63A. |
| 45 | Providing and fixing 125 A,36KA,FPMCCB rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. |
| 46 | Supplying and fixing FP sheet steel enclosure with IP 30 protection on surface/ in recess etc. as required (without MCB / RCCB / Isolator). |
| 47 | Supplying and fixing 20 amps, 240 volts, SPN industrial type, socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 amps “C” curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. |
| 48 | Supplying and fixing suitable size GI/PVC box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. |
| 49 | Supplying and fixing suitable size GI/PVC box with modular plate and cover in FRLSont on surface or in recess, including providing and fixing 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required. |
| 50 | Supplying and drawing of 1 run of cable UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required. |
| 51 | Supply and fixing of Cat 6 RJ-45 information outlets including Single face plate & fixing of 2 module GI/PVC box along with modular base & cover plate including terminations and ferruling. |
| 52 | Supplying and drawing 2 Pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required. |
| 53 | Supplying and fixing of Telephone socket outlet on the 2 module GI/PVC box along with modular base & cover plate including terminations and ferruling. |
| 54 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. |
| 55 | Suplying and fixing of single pole blanking plate in the existing MCB DB complete etc. as required. |
| 56 | Supply and Fixing of TW / PVC Round Blocks |
| 57 | Laying/ removal the existing cable of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering, refilling the trench and shifting of the removed cable to electrical stores etc as directed by engineer in charge-Upto 35 sq. mm. |
| 58 | Laying/ removal the existing cable of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering, refilling the trench and shifting of the removed cable to electrical stores etc as directed by engineer in charge-Above 35 sq. mm and upto 95 sq. mm. |
| 59 | Laying/ removal the existing cable of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering, refilling the trench and shifting of the removed cable to electrical stores etc as directed by engineer in charge-Above 95 sq. mm and upto 185 sq. mm . |
| 60 | Laying/ removal the existing cable of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering, refilling the trench and shifting of the removed cable to electrical stores etc as directed by engineer in charge-Above 185 sq. mm and upto 400 sq. mm. |
| 61 | Laying/removal of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation, sand cushioning, protective covering and refilling the trench etc as required-Upto 35 sq. mm. |
| 62 | Laying/removal of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation, sand cushioning, protective covering and refilling the trench etc as required-Above 35 sq. mm and upto 95 sq. mm. |
| 63 | Laying/removal of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation, sand cushioning, protective covering and refilling the trench etc as required-Above 95 sq. mm and upto 185 sq. mm. |
| 64 | Laying/removal of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation, sand cushioning, protective covering and refilling the trench etc as required-Above 185 sq. mm and upto 400 sq. mm. |
| 65 | Laying / removal the existing cable of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL/DWC pipe as required and shifting of the removed cable to electrical stores etc as directed by engineer in charge-Upto 35 sq. mm. |
| 66 | Laying / removal the existing cable of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL/DWC pipe as required and shifting of the removed cable to electrical stores etc as directed by engineer in charge-Above 35 sq. mm and upto 95 sq. mm. |
| 67 | Laying / removal the existing cable of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL/DWC pipe as required and shifting of the removed cable to electrical stores etc as directed by engineer in charge-Above 95 sq. mm and upto 185 sq. mm. |
| 68 | Laying / removal the existing cable of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL/DWC pipe as required and shifting of the removed cable to electrical stores etc as directed by engineer in charge-Above 185 sq. mm and upto 400 sq. mm. |
| 69 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required-63 mm dia (OD-63 mm & ID-51 mm nominal). |
| 70 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required-90 mm dia (OD-90 mm & ID-76 mm nominal). |
| 71 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required-63 mm dia (OD-63 mm & ID-51 mm nominal). |
| 72 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required-90 mm dia (OD-90 mm & ID-76 mm nominal). |
| 73 | Supplying and fixing cable route marker with 10 cm X 10 cm X 5 mm thick G.I. plate with inscription there on, bolted /welded to 35 mm X 35 mm X 6 mm angle iron, 60 cm long and fixing the same in ground as required. |
| 74 | Supplying and making straight through joint with heat shrinkable kit including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required-Up to 3½ X 50 sq. mm (3½ X 25 sq. mm ,3½ X 35 sq.mm & 3½ X 50 sq. mm sizes). |
| 75 | Supplying and making straight through joint with heat shrinkable kit including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required-3½ X 95 sq. mm. |
| 76 | Supplying and making straight through joint with heat shrinkable kit including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required-3½ X 185 sq. mm. |
| 77 | Supplying and making straight through joint with heat shrinkable kit including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required-3½ X 300 sq. mm. |
| 78 | Supplying and making straight through joint with heat shrinkable kit including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required-3½ X 400 sq. mm. |
| 79 | Supplying and making straight through 300 sq. mm HT cable jointing with cast resin compound, including ferrule and other jointing materials, for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required |
| 80 | Cable Fault Detection for all types of HT underground cbles from 16 sq mm to 400 sq mm upto 250 Mtrs length of cable |
| 81 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required-3½ X 25 sq. mm (28mm). |
| 82 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required-3½ X 35 sq. mm (32mm). |
| 83 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required-3½ X 95 sq. mm (45mm). |
| 84 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required-3½ X 185 sq. mm (57mm). |
| 85 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required-3½ X 300 sq. mm (70mm). |
| 86 | Supplying and making 240/300 sq. mm outdoor HT cable end jointing with cast resin compound, including lugs and other jointing materials, for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required : |
| 87 | supplying and making 240/300 indoor HT cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required: |
| 88 | Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. |
| 89 | Re-lettering with Japan paint of required size,approved brand and manufacture directed by engineer in charge. |
| 90 | Painting of Electrical panel / Transformer/poles by using enamel paint with proper safety of the same by spray gun incl.thoroughly cleaning the surface of all rust & dust with wire brush scrapper and sand paper |
| 91 | Removal of existing panel key and replacement with new one with necessary welding works and making good as directed by engineer in charge. |
| 92 | Supply and fixing of the M.V danger radium labeling for Db's, panels and feeder pillars as directed by engineer in charge. |
| 93 | Supplying and fixing of 32 mm dia X 2.00 metres long G.I. pipe (medium class) bracket for mounting of fluorescent / HPMV / HPSV street light fitting on pole/wall including bending the pipe to the required shape, 2 nos 40 mm X 3 mm flat iron clamps with nuts, bolts and washer, painting the flat iron with primer and finish paint etc. as required |
| 94 | Supply and erection of LED indication lamps on the existing panel board. |
| 95 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:1½:3 (1 Cement: 1½ coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 96 | Brick work with non modular fly ash bricks conforming to IS:12894, class designation 10 average compressive strength in super structure above plinth level up to floor V level in : Cement mortar: 1:4 (1 cement : 4 coarse sand) |
| 97 | 12 mm cement plaster finished with a floating coat of neat cement of mix : 1:4 (1 cement: 4 fine sand) |
| 98 | Fabrication, Transportation and supply of hot-dip galvanized Octogonal Pole with BSEN - 10025 grade S 355 JO steel plate for shaft, IS 2062 for base plate with door opening arrangement, including chain for anti theft mechanism, supply of suitable boards with bakelite sheet, din channel for MCB's as per IS specification suitable to withstand the wind speed of 180 KMPH for 9 Mtrs height Pole having dimensions Bottom 155mm, Top 70mm with 3mm thick, base plate 260 x 260 x 16mm and 4 Nos of M24 x 750mm long 'J' bolts along with template or equivalent. |
| 99 | Foundation and erection charges with special T&P, for 9.00Mtrs / 10Mtrs long Octagonal / Conical pole duly erecting on base plate duly providing 4 Nos foundation bolts with nuts with providing of 0.60Mtrx0.60Mtrsx1.40 Mtr size M20 cc work vibrated concreting mixing with necessary steel (15kgs) reinforcement asdirected by the field engineers during execution including centering, decentering, water curing as required, soil exacavation, back filling, muffing removal and coil earthing including all labour charges and cost and conveyance of materials etc. complete. |
| 100 | Chemical earthing with copper earth pipe as earth electrode 2.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc.(with charcoal/ coke and salt total of minimum 50 kg) as required. |
| 101 | Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with 96 kg charcoal/ coke , 5 kg salt and 5 kg bentonite powder as required. |
| 102 | Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground/recess as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required. |
| 103 | Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. |
| 104 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required. |
| 105 | Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required. |
| 106 | Hire and running charges of crane 20 tonne capacity including driver & fuel charges working for 8 hours per day |
| 107 | Engaging of unskilled Man power for digging, Material shifting and panel cleaning etc., working for 8 hours per day. |
| 108 | Engaging of Skilled Electricain for 8 hours per day to Carryout routine maintenance and servicing of LT.Cubical pannel board cleaning, tightning the contacts,and clicking the operating machanism for smooth functioning of switches and putting them in smooth working condition. Please Enable Macros to View BoQ information |