| 1 | earthwork |
| 2 | Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. |
| 3 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 4 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 5 | Centering and shuttering including strutting, propping etc. and removal of form work for footing column beam |
| 6 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. |
| 7 | Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundations and plinth in : Cement mortar 1:3 (1 cement: 3 coarse sand) |
| 8 | 15 mm cement plaster on rough side of single or half brick wall of MIX: |
| 9 | 1:4 (1 cement: 4 coarse sand) |
| 10 | Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complet |
| 11 | Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq.meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-Charge.With cement mortar 1:4 (1 cement : 4 fine sand) |
| 12 | Taking out doors, windows and clerestory window shutters (steel or wood) including stacking within 50 metres leadOf area 3 sq. metres and below |
| 13 | Providing and fixing clear sheet glass beded in putty and fixed with/ without wooden bidding including necessary cutting and glass to be required sized( Payment for wooden bead shall be made separatelyI) Area of glass panes not exceeding 0.15 sqm.3 mm thick |
| 14 | Distempering with 1st quality acrylic distemper (ready mixed) having VOC (Volatile Organic Compound ) content less than 50 gram/ litre, of approved brand and manufacturer including applying additional coats wherever required to achieve even shade and colour Pump house wall |
| 15 | Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. |
| 16 | Providing and laying interlocking concrete pavement block with M40 grade of concrete blocks having thickness 80 mm as per technical specification.Including edge block/Edge restraints |
| 17 | Supplying and filling sand gravel in foundation trenches/ pits, side berms of road open parking area over slushy soil including pumping out water (if necessary), ramming etc. complete for strengthening the bearing capacity of the soil/sub soil as directed and specified. |
| 18 | Finishing walls with water proofing cement paint of required shade |
| 19 | Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete |
| 20 | Supplying, fitting & fixing chain link fencing of 10 S.W.G, G.I. wire 50mm × 50mm mesh fitted to M.S angle iron post at 2000mm apart of specification detailed below including supplying, fitting & fixing hooks, eye bolts with nuts, staples and bolts including three horizontal lines of G.I wire 10 S.W.G at top, middle and bottom and with one vertical line to each fencing post for keeping the fencing tight and erect complete, including one coat of primer painting to M.S angle iron post in P.C.C base etc. with following. a) Corner and end posts with M.S angle of size 50mm × 50mm × 5mm and length not less than 1800mm only duly slotted and bottom torqued with two numbers as stay posts. b) Intermediate post with M.S angle of size 40mm × 40mm × 5mm length and not less than 1800 mm only duly slotted and bottom torqued and splayed. c) Stay post with M.S angle of size 35 mm × 35mm × 5mm and length not less than 1800 mm duly slotted and bottom torqued and slayed. All M.S angle iron posts are to be fitted to P.C.C base embedded not less than 600mm (P.C.C work shall be measured and paid separately) Please Enable Macros to View BoQ information |