| 1 | Laying and Jointing PVC Pipe. Heading |
| 2 | Extra for earthwork in hard soil as per specification and direction of E/I.( vide classification of soil item-B) |
| 3 | Earth filling in foundation trenches and plinth in layers not exceding 150 mm thick well watered, rammed, fully compacted and fine dressed with earth obtained from excavation of foundation trenches within a lead of 50 M and lift of 1.5 M all complete as per building specification and direction of E/I. (mode of measurement compacted volume) |
| 4 | Filling in foundation trenches and plinth in layers. Not exceeding 150 mm thick well watered, rammed fully compacted and fine dressed with earth obtained after cutting within a lead of 50 M and lift of 1.5 M all complete as per building specification and direction of E/I (Mode of measurement compacted volume) |
| 5 | Providing coarse clean sand in filling in in foundation trenches or in plinth including ramming and watering in layers not exceeding 150mm thick with all leads and lifts including cost of all materials labour, royalty and taxes all complete as per building specification and direction of E/I (Mode of measurement compacted volume) |
| 6 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:2:4 (1 cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size) |
| 7 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level. 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size) |
| 8 | Centering and shuttering including strutting, propping etc. and removal of form forFoundations, footings, bases of columns, etc. for mass concrete |
| 9 | Providing Tor steel reinforcement of 8mm dia rods as per approved design and drawing exclusive carriage of M.S. bars to work site, cutting, bending and binding with annealed wire with cost of the wire, removal of rust, placing the rods in position all complete as per building specification and direction of E/I. TMT Fe 500 (only valid for SAIL & TATA STEEL) |
| 10 | Providing Tor steel reinforcement of 10mm dia rods as per approved design and drawing exclusive carriage of M.S. bars to work site, cutting, bending and binding with annealed wire with cost of the wire, removal of rust, placing the rods in position all complete as per building specification and direction of E/I. TMT Fe 500 (only valid for SAIL & TATA STEEL) |
| 11 | Providing Tor steel reinforcement of 12mm dia rods as per approved design and drawing exclusive carriage of M.S. bars to work site, cutting, bending and binding with annealed wire with cost of the wire, removal of rust, placing the rods in position all complete as per building specification and direction of E/I. TMT Fe 500 (only valid for SAIL & TATA STEEL) |
| 12 | Providing designation 75B one brick flat soling joints filled with local sand including cost of watering taxes royalty all complete as per building specification and direction of E/I. |
| 13 | Providing two coats of plastic emulsion paint of approved shade and make over a coat of cement primer over new surface including preparing plastered surface by rubbing smooth with pumice stone or fine sand paper, applying putty wherever required, scaffolding washing of floor and taxes all complete as per building specification and direction of E/I. |
| 14 | Construction of RCC railing of M30 Grade in-situ with 20 mm nominal size aggregate, true to line and grade, tolerance of vertical RCC post not to exceed 1 in 500, centre to centre spacing between vertical post not to exceed 2000 mm, leaving adequate space between vertical post for expansion, complete as per approved drawings and technical specifications. |
| 15 | Providing, fitting and fixing mild steel railing complete as per drawing and Technical Specification |
| 16 | Providing & fixing 2 mm thick corrugated copper plate in expansion joint complete as per drawing & Technical Specification. |
| 17 | Providing & fixing 20 mm thick compressible fibre board in expansion joint complete as per drawing & Technical Specification. |
| 18 | Earth work in excavation in foundation trenches in ordinary soil ( vide classification of soil item A) and disposal of excavated earth as obtained to a distance upto 50M including all lifts leveling ramming the foundation treanches, removing roots of trees, and shrubs all complete as per approved design, building specification and direction of E/I. |
| 19 | Plain/Reinforced Cement concrete in open Foundation complete as per Drawing and Technical specifications. PCC Grade M15 using batching plant & manual placing |
| 20 | Plain/Reinforced Cement Concrete in Open Foundation complete as per Drawing and Technical Specifications. RCC Grade M25 using batching plant, transit mixer & Concrete pump. (Including form work but excluding reinforcement) |
| 21 | Plain/Reinforced cement concrete for wall & slab etc. complete as per Drawing and Technical specifications.RCC Grade M25 using batching plant, transit mixer & concrete pump. (Including form work but excluding reinforcement) |
| 22 | Supplying, fitting and placing un-coated HYSD bar Reinforcement in Foundation complete as per Drawing and Technical specifications |
| 23 | Providing weep holes in Brick masonary/ plain/ Reinforced concrete abutment, wing wall/ return wall with 100 mm dia AC pipe, extending through the full width of the structure with slope of 1V:20H towards drawing face. Complete as per drawing and Technical specifications. |
| 24 | PCC M15 Grade leveling course below approach slab complete as per drawing and Technical specifications.PCC Grade M15 using batching plant & manual placing |
| 25 | Reinforced cement concrete approach slab including reinforcement and formwork complete as per Drawing and Technical specifications. |
| 26 | Drainage spouts complete as per Drawing and Technical Specifications. |
| 27 | Providing and laying Cement concrete wearing coat M-30 grade including reinforcement complete as per drawing and Technical specifications. |
| 28 | Providing & fixing 20 mm thick compressible fibre board in expansion joint complete as per drawing & Technical Specification. |
| 29 | Earth work in excavation of foundation trenches in ordinary soil (Vide classification of soil item-A) and disposal of excavated earth so obtained (50M. away from the edge of the trenches) with initial lead of 150M and initial lift of 1.5M as per specification and dir- ection of E/I. |
| 30 | Extra for earth work in hard soil (Vide classification of soil item-B) all complete as per specification and direction of E/I. |
| 31 | Evtra for Marshy soil slush and daldal ( vide classification of soil item -F) all complete as per specification and direction of E/I. |
| 32 | Supply and Labour for laying sand filter under brick pitching or boulder pit- ching in slope or apron including light ramming etc. all complete job as per specification and direction of E/I. |
| 33 | Supplying labours and tools for laying and jointing H.D.P.E. pipes in trenches and making butt welded joint supplying heating mirror, jack etc. and providing night guard, barrier and red light to safe guard against accident all complete as per specification and direction of E/I. + supply of HDPE pipe 90/80 mm dia |
| 34 | Providing and Supplying in standard lengths High Density Polyethylene pipe (HDPE) 25mm to 500mm dia confirming to IS 4984/ 14151 / 12786 / 13488 (Latest Revion with necesssary jointing materials like mechanical connector i.e. thread / insert joint /quick release coupler joints / compression fitting joint or flanged joints 75 mm |
| 35 | Wiring for light point/fan point / exhaust fan point/call bell point, with 1.5 sq.mm FR PVC insulated copper conductor single core in surface/recessed PVC conduit, piano type switch, phenolic laminated sheet with suitable size PVC/MS box etc as required. Group A |
| 36 | S.I.T.C of following rating approved make LED Bollard fitting with cylindrical shape of height 600 to 850mm power input-8/9 watt with die cast aluminium housing opel with PC diffuser, IP:65/54 protection, conferming to IS:10322 part 5 etc all complete as required.(excluding plinth charge) |
| 37 | 30W COB based round LED light with multiple beam angles (36 degree) |
| 38 | Carrrage of materials |
| 39 | Aggregate |
| 40 | Bricks |
| 41 | Steel |
| 42 | Metal |
| 43 | Add GST @18% |
| 44 | Add Labour Cess @1% Please Enable Macros to View BoQ information |