| 1 | Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m depth for foundation etc, or for shafts, wells, cesspits, manholes, pier holes, cable, pipes etc not exceeding 10 Sqm on plan and getting out in soft/ loose soil for laying cables / pipes / erection of poles etc complete all as specified and directed. |
| 2 | Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m depth for foundation etc, or for shafts, wells, cesspits, manholes, pier holes, cable, pipes etc not exceeding 10 Sqm on plan and getting out in hard/ dense soil for laying cables / pipes / erection of poles etc complete all as specified and directed. |
| 3 | Returning filling in soil including spreading, leveling, watering well ramming in layers not exceeding 25 cm thick, complete all as specified and directed. |
| 4 | Removing surplus excavated material (soil) to a distance n. exc 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed. |
| 5 | M&L Plain cement concrete 1:4:8 type D-2 (using 40mm graded crushed stone aggregate) as in foundation of pole etc complete all as specified and directed. |
| 6 | M&L Plain cement concrete 1:3:6 type C-2 (using 40mm graded crushed stone aggregate) as in foundation, filling and mass concrete complete all as specified and directed. |
| 7 | M&L Plain cement concrete (1:2:4) type B-1 (using 20mm graded crushed stone aggregate) as in stay filling or pole coping etc including necessary form work for rough finished surfaces complete all as specified and directed. |
| 8 | S&F in repairs GI tubing light grade 80 mm dia with all fittings such as clamps laid in trenches or fixed on wall, along pole including fixing arrangement nut bolts, clamps etc complete for protection of electric cable complete all as specified and directed.Notes : Excavation and earth work shall be measured and paid seperately under appropriate items of Schedule 'A'/ BOQ |
| 9 | Taking out old unserviceable RCC steel tubular pole with and including embedded portion of PCC foundation with and including material and labour for new steel tubular poles type 410, SP-55 (11 meters long) with 300mmx300mmx6mm mild steel base plate continuously welded to pole, MS plate 3 mm thick finial taper plug bolt, nuts and screws all as specified including factory painted with two coats of black bituminous paint internally throughout and externally for embedded portion and applying two coats of aluminium paint over a coat of red oxide primer on remaining exposed surfaces and making alternate black and yellow strips 30 cm high with super enameled paint over a coat of red oxide primer up to 1.5 mtrs height from ground level/coping after erecting complete all as specified and directed. NOTE : (i) The rate of necessary earthwork such as excavation, returning filling, removal and formwork is included in this item. Nothing extra shall be paid on this account.(ii) Cement concrete work shall be measured and paid seperately under respective item of schedule 'A'/ BOQ. |
| 10 | S&F in replacement of overhead ACSR conductor to HT overhead lines on existing poles with XLPE insulated AB cable 3 core X 95 sqmm phase core twisted around aluminium alloy insulated messenger conductor conforming to IS: 14255 including identification of phase by Ridges provided on the insulation of Phase conductors: 1 ridge for the 1st Phase, 2 Ridges for the 2nd Phase and 3 Ridges for the 3rd Phase including accessories like Anchor Clamp, Suspension Clamp, Line Connector, service clamp, insulation piercing connectors, (IPC for Tap from Bare lines) Dead End, Suspension clamp, I Hook etc complete all as specified and directed. |
| 11 | M&L preparation of old painted surfaces of steel tubular pole of 9/11 mtr strut pole (LT/HT) including protection pipe, cross arms, clamps, GI pipe bracket of street/ security light, anti climbing devices etc, including scraping out old rusted paint on all the metallic surfaces complete all as specified and directed.Note : Numbering of the poles and repainting blue bands shall be done with synthetic enamel paint, letter/ band's shape and size shall be printed complete all as specified and directed. |
| 12 | Trimming/ cutting of all trees branches and cleaning of bushes upto 2 metre distance both side from nearest conductor/ earth wire at LT/HT overhead line including cleaning of site and depositing of material upto 50 metre distance complete all as specified and directed. |
| 13 | Surface excavation, grass cutting not exceeding 15cm in depth with and including cleaning the bushes and vegetation / root of small trees, and leveling with around the poles / feeder piller boxes / sub stations with and including removal compete all as specified and as directed. |
| 14 | M&L Boring of holes under road, pavement, hard standing by using ultra sounding technique suitable for 0.4 mpa working pressure trenchless technology, with and including Galvanised Iron light grade 100 mm dia pipe all as specified and directed. Note: The rate of Galvanised Iron light grade 100 mm dia pipe is included in this item and nothing extra shall be paid on this account |
| 15 | M&L cross arms, bracings, supports, clamps and back plate fabricated from structural steel section including nuts, bolts, washers, welding bending cold or hot, drilling holes for bolts in any shapes size as directed and inclusive of one coat of zinc chromate primer, with and including one under coat and one finished coat of aluminium paint complete including dismantling of existing unservicable cross arms of MS channel complete all as specified and directed. Notes: (a) The measurment and payment shall be made on the actual weight of mild steel material. The weight of primer and paint shall not be considered while weighing of mild steel material. But the rate of one coat of zinc chromate primer, with and including one under coat and one finishing coat of aluminium paint is included in this item and nothing extra shall be paid on this account. |
| 16 | S&F in replacement Straight through joints for underground cable including jointing material, accessories and labour complete for 3 core XLPE armoured Aluminum conductor cable of size 50 sqmm to 95 Sqmm 3 core complete all as specified and directed. |
| 17 | S&F in replacement cable jointing kit for 11 KV grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured Aluminium conductor cable of size 50 sqmm to 95 Sqmm complete all as specified and directed. |
| 18 | S&F in replacement cable jointing kit for 11 KV grade cable for out door termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured Aluminium conductor cable of size 50 sqmm to 95 Sqmm complete all as specified and directed. |
| 19 | Supplying, fixing and testing of gang operated air breaker switch (GOD), triple pole, mechanically operated mounted on isulators and steel frame with operating mechanism worked from ground level using heavy duty GI pipe for current rating 200 Amps, out door type (confirming to IS specifications) HT 11 KV, tripple pole with fixed contacts of phosphorous and bronze and a set of drop out HT fuse assembly, fuse carrier fitting, 12 insulator type mounted on MS channel operating rod with pad lock arrangement complete all as specified and directed including dismantling old unserviceable. |
| 20 | S&F Expulsion type drop out fuse with all accessories and contact insulator etc fixed on HT pole rating up to 25 Amps suitable for 11 KV 3 pole with two Nos insulator per pole including dismantling old unserviceable one complete all as specified and directed. |
| 21 | S&F Pin type insulator, porcelain, vitreous, white brown, including one galvanised mild steel spindle, two galvanised iron washer and one galvanised iron nut, 150 mm dia and 150 mm height for 11000 volts grade including taking down old unserviceable insulators complete all as specified and directed. |
| 22 | S&F Disc type porcelain insulators 145 mm height and 255 mm dia ball and socket type ,white ,brown or green single disc assembly for tension with tension clamps for conductors working pressure 11 KV volts grade including taking down old unserviceable insulators complete all as specified and directed. |
| 23 | S&F loop type porcelain vitreous white brown, or green insulator with over all dimension 90X140 mm clearance of hole 25.5 mm including taking down old unserviceable insulators complete all as specified and directed. |
| 24 | S&F in repairs Danger notice plate of 1.6mm thick mild steel sheet, vitreous enameled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for HT, 25x20cm size complete all as specified and directed. |
| 25 | S&F in repairs erect/ ground HT cable route indicator made out of GI plate 3 mm thick and 6 inches dia duly marked with working voltage, and route indicator fixed with angle iron of size 25 x25 x3 mm thick, 50 cm long embedded in PCC 1:2:4 type B1 of size 20 x 20 x 20 cm in ground complete all as specified and directed. |
| 26 | Supply and Filling in with new Stabilizer/transformer oil low viscosity of approved make as per IS-335 of 1992 and die-electric strength 50 KV when tested at 2mm gap complete all as specified and directed. |
| 27 | M&L Filtration of AVR/Stabilizer/transformer oil of transformers step down 11KV / 0-433 V indoor/outdoor type installed at different sub stations/locations using filtration and heating equipment at site by re-circulating transformer oil heating, dehydration and improving di-electric strength of the oil to withstand 40 KV for one minute including testing of oil complete all as specified and directed.Note : Transformer oil test kit shall be provided by the contractor at site for testing of oil all as specifiedand directed. |
| 28 | Hiring of distribution Transformer of capacity 315 KVA, 3 phase oil cooled suitable for HT 11KV/433V distribution line complete all as specified and directed. |
| 29 | M&L Strip opening of transformer and removing the top cover for draining the transformer oil and taking out the core alongwith HT/LT coil (windings) assembling the core after replacement of HT/LT coils heating varnishing, testing and housing accessories in transformer body and connection up filling in dehydrated new transformer oil and connecting, commissioning with existing electrical system HT/LT on load of capacity not exceeding 160 KVA including taking down and refixing complete all as specified and directed.NOTE :- Transformer oil will be measured and paid seperately. |
| 30 | Description all as per item No 29 above but above 160 KVA up to 315 KVA |
| 31 | S&F in repairs Winding of HT coil of different type, capacity and make of transformer with approved quality supper enameled copper wire/ strips of approved make of suitable gauge and number of turns along with allied materials like cork sheet, fiber glass insulations, paper insulations, cotton/ Empire tap and tube wooden blocks bolts, nuts and washer (Brass) soldering and other packing material etc. all as required at site or directed. |
| 32 | S&F in repairs Winding of LT coil of different type, capacity and make of transformer with approved quality supper enameled copper wire/ strips of approved make of suitable gauge and number of turns along with allied materials like cork sheet, fiber glass insulations, paper insulations, cotton/ Empire tap and tube wooden blocks bolts, nuts and washer (Brass) soldering and other packing material etc. all as required at site or directed. |
| 33 | S&F in replacement of HT Bushes porcelain, vitreous with brass spindle, threaded with washer, nuts, lock and rubber seal suitable for transformer of capacity upto 200 KVA complete all as specified and directed. |
| 34 | S&F in replacement of LT bushes porcelain Vitreous with brass spindle threaded with washers nuts, lacknuts and rubber seal for indoor/outdoor transformer of capacity not exceeding 200 KVA complete all as specified and directed. |
| 35 | S&F in replacement of Top gasket made of 3mm thick cork sheet with suitable holes for transformer including providing suitable size of bolts, nuts and washer for transformer top cover complete for any capacity upto 200 KVA complete all as specified and directed. |
| 36 | Supply only breather assembly plastic body of standard size filled with silica gel of transformer up to 200 KVA complete all as specified and directed. |
| 37 | M&L in replacement of Lightening arrestors gapless metal oxide type complete with all fittings, suitable for a system voltage of 11 KV and transmission class, discharge capacity 65 kilo amp complete all as specified and directed. |
| 38 | Taking down old jumper connection of 11 KV yard pole structure from line/AB/DO & refixing complete with new conductor, including line tap, lugs & PVC alkdin/pipe sleevs etc complete all as specified and directed. Please Enable Macros to View BoQ information |
| 39 | Taking down old jumper connection of 11 KV yard pole structure from line/AB/DO & refixing complete with new conductor, including line tap, lugs & PVC alkdin/pipe sleevs etc complete all as specified and directed. Please Enable Macros to View BoQ information |