| 1 | B/R PORTION |
| 2 | Dismantling of plain or corrugated steel sheeting,any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified and as directed. |
| 3 | S&F Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour as directed having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws complete all as specified and directed. |
| 4 | S&F Pre- painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in ridges, hips, valley gutters, eave board fixed with self tapping screw as specified . |
| 5 | Domolition of brick work or stone masonry, built in cement mortar including all quoins, arches, pillers, etc but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and as directed. |
| 6 | M&L for Brick work with sub-class 'B' bricks, straight or curved on plan to any radius in full brick thick walls, built in cement mortar 1:4 complete as specified and directed. |
| 7 | M&L for Brick work with sub-class 'B' bricks, straight or curved on plan to any radius in half brick thick walls, built in cement mortar 1:4 complete as specified and directed. |
| 8 | Taking down roof trusses, coupled rafters or trussed beams clear span above 4m to 8mtr etc complete all as specified and as directed. |
| 9 | Dismantling timber scantlings un framed in fillets, rails, posts, rafters,purlins, etc. under 40 sq. cm in section complete all as specified and as directed. |
| 10 | S&F Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc confirming to Fe 410-W (Gde- E- 250) complete all as specified and directed. |
| 11 | M&L Rolled mild steel plates (plain or chequered), channels, square cut or notched (ordinary or counter sunk) forming holes, with riveted, bolted or welded attachment etc, conforming to Fe-290 Gde E-165 compete as specified and directed |
| 12 | S&F Mild steel screw bolts (machine made) with hexagonal heads at one end and screws other end to be fitted with washes and one hexagonal nut, exc 5cm and n.exc 10cm long and dia of neck 11 to 15 mm as specified and directed. |
| 13 | M&L for preparation of new iron and steel surfaces of any description, exc 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide, zinc chrome primer complete as specified and directed. |
| 14 | Demolition Wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/blankets, any thickness, including cover fillets, etc complete all as spfd and directed. |
| 15 | S&F Anodised aluminium snap grid frame work of size 605 x 605mm for false ceiling all as specified and directed. |
| 16 | M&L for 4 mm thick, Non asbestos fibre cement building boards fixed in ceiling or laid/ inserted to timber/GI/Aluminium frame work with screws, etc completed all as specified. |
| 17 | Demolition of cement concrete on roofs, floors (other than ground floors), beams, staircases, landing, chajjas and similar suspended work etc complete all as spd and directed. |
| 18 | M&L for PCC 1:3:6 type C-2 (Using 40 mm graded stone aggregate) in foundations, filling and mass concrete (sunken floor filling) complete all as specified and as directed. |
| 19 | Demolition of PCC in ground floor or paving of any description n.exc. 15cm thickness (Un re-inforced) below or above GL complete all as specified and directed.. |
| 20 | M&L for 75 mm thick PCC 1:3:6 type C2 using 40mm graded stone agg as in sub base and plinth protection, finished even and smooth w/o using extra cement complete all as specified and as directed. |
| 21 | Taking down cement plaster on brick wall/stone wall, ceilings, sunken floors etc, racking out joints, hacking for key & scrubbing with water completely complete as specified and directed. |
| 22 | M&L rendering 15mm thick plaster in two layers (10mm +5mm) on brick or concrete surfaces in CM 1:4 mixed with WPC on second layer finished the surface even and smooth without using extra cement complete all as specified and directed. (Note- supply only WPC shall be measured and paid seperately). |
| 23 | Supply only Liquid water proofing compound complete all as specified and directed. |
| 24 | M&Lfor rendering 10mm thick plaster on other than fair faces of brick or concrete surfaces in CM 1:6 finished the surface even and smooth without using extra cement complete all as specified and directed . |
| 25 | M&L for prepartion of newly plastered surfaces of walls and applying two coats of oil bound distemper over a coat of 1.5mm thick wall care putty including primer complete all as specified and directed. |
| 26 | M&L for preparation of new surfaces of wall and applying two coats of weather exterior acrylic emulsion paint over a coat of 1.5mm thick wall care putty including priming coat of exterior primer complete all as specified and directed. |
| 27 | M&L for preparing new plastered surface of ceiling and applying two coats of white wash complete all as specified and directed. |
| 28 | S&F Mild steel framed work such as grills, gratings, etc.with ends of bars shouldered and/or riveted, or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railings, framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified and as directed. |
| 29 | Dismantling floor, hearth or wall tiling incl cement mortar bedding (but not backing) and rubbish off the premises complete all as specified and as directed. |
| 30 | M&L for non-skid ceramic (coloured) tiles 7-8mm thick area of each tiles exeeding 0.18sqm but not exceeding 0.38 sqm in floor etc.set and jointed in neat cement slurry and pointed in white or coloured cement to match complete including 15mm thick Screed bed or bedding layer in cement mortar 1:4, complete all as specified and as directed. |
| 31 | M&L for non-skid ceramic (coloured) tiles 7-8mm thick area of each tiles exeeding 0.11sqm but not exceeding 0.18 sqm in floor etc.set and jointed in neat cement slurry and pointed in white or coloured cement to match complete including 15mm thick Screed bed or bedding layer in cement mortar 1:4, complete all as specified and as directed. |
| 32 | M&L for glazed ceramic (coloured) tiles of size 450x350x6-7mm thick as in vertical surface set and jointed in neat cement slurry and pointed in white or coloured cement to match including 10 mm thick backing course in cement mortar 1:4 complete all as specified and as directed. |
| 33 | Dismantling of Stone slabs and tiles of any description or thickness in floors , aprons etc. (Dismantling, Laid dry or laid and pointed) complete all as specified and as directed. |
| 34 | M&L for Granite (of any type) work (table rubbed and polished) 20 mm thick in steps, jambs, pillars, window-cills, cooking platforms,over 15 mm thick screed bed in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite, etc complete all as specified and as directed. |
| 35 | M&L for rounding to edges of stone slabs one edge, such as in steps, cooking platforms and other similar situations complete all as specified and as directed. |
| 36 | M&L for preparation of new or previously untreated surface of steel and iron work of any description, not otherwise described, over 10 cm width or girth and applying two coats of Synthetic enamel paint (Ordinary tint) over a coat of red oxide primer complete all as specified and as directed. |
| 37 | Taking down chowkats or frames (without taking off shutter from the frame) not exc. 1.5 sq.m each and removing complete all as specified and as directed. |
| 38 | M&L for cement concrete 1:2:4 type BI using 20mm graded stone aggregate in bed block for hold fasts and coping incl necessary form work weathering slighly rounded or chamfered angles and treating and making good the disturbed portion complete all as specified and as directed. |
| 39 | S&F stainless steel wire cloth, 0.36 mm nominal dia of wire and average width of apreture 1.40 mm & fixed with stainless steel wire staples fixed complete all as specified and as directed. |
| 40 | S&F solid PVC frame size 50mmx47mm made out of 5mm plain colour PVC sheet re-enforced with MS square tube complete all as specified and directed |
| 41 | S&F factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded/sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement complete all as specified and as directed. |
| 42 | S&F 100mm Butt hinges, extruded aluminium alloy with galvanised mild steel hinge pin,anodised and fixed, type B-21. |
| 43 | S&F 150mm long aluminum handle febricated type anodised.complete all as specified & as directed. |
| 44 | S&F 150mm length of aluminium anodised barrel tower bolts of extruded section and fixed complete all as specified and as directed. |
| 45 | S&F 300mm aluminium anodised sliding door bolt, with hasp and staple, (bolt type) and fixing clips of sheet steel, cast or extruded section and fixing bolts and sliding bolts of extruded section or cast aluminium alloy complete all as specified and directed |
| 46 | S&F in repair mild steel 300mm , ordinary rat tail rod pattern springs including roller and roller plate complete all as specified & directed. |
| 47 | Providing and fixing Powder coated aluminium (minimum thickness of powder coating 50 micron) work for doors, windows,ventilators and partitions (Fixed portions) with extruded built up standard tubular sections/appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-Charge.Note:- (i) Labour charges for fixing of glass/wire guage/aluminum grills shall be included in the quoted unit rate. (ii) Glass/Wire Guage/aluminum grills shall be measured and paid seperately at supply only rates |
| 48 | Supply only 4 mm thick sheet glass, frosted one side and glazing with oil putty in square not exceeding 0.5 Sq. m in each pane complete all as specified & as directed. |
| 49 | S&F for 15 mm bore “medium grade” mild steel galvanised iron (GI) tubing with all fittings fixed to wall, ceiling or floors, including taking up/down old tubing complete all as specified and as directed. |
| 50 | S&F for 20 mm bore “medium grade” mild steel galvanised iron (GI) tubing with all fittings fixed to wall, ceiling or floors, including taking up/down old tubing complete all as specified and as directed. |
| 51 | S&F in repair sinks made of stainless steel lmm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 495mm x 420mm bowl size 410mm x 330mm x160mm complete all as specified and directed. |
| 52 | S&F in repair vitreous china squatting pan Orissa pattern size 580mm x 440mm white with integral foot rest, provn and fixing of 10 litres capacity low level PVC flushing cistern, PVC connection pipe 15mm dia 600mm long with two check nut and washer of including provision of lime concrete bedding, connection to trap and flush pipe etc as in floor all as specified and as directed. |
| 53 | S&F in repair brass Chromium plated 125mm size shower roses with or without swivel joints, any size, including fixing to steel pipe or union, etc complete all as specifed and directed. |
| 54 | S&F 15mm dia Brass Stop valves/angle cock, screwed down, high pressure, chromium plated, screwed both ends for iron pipe or for unions and fixed in repairs complete all as specified and directed. |
| 55 | S&F in repairs Vitreous China wash basin, white, flat back, size 550x400mm including cutting for & pinning in ends of brackets or erracting stand but exclusive of fixing of supply of waste pipe complete all as specified and directed. |
| 56 | S&F 15mm dia Pillar taps fancy type, chromium plated, screwed down high pressure, with or without lettered ‘Hot' or ‘Cold' with long screwed shanks and fly-nuts, screwed for iron pipe and fixed in repairs complete all as specified and directed. |
| 57 | S&F in repair 15 mm dia Bib cock fancy type with chromium plated screwed down, screwed for iron pipe or for brass ferrule all as specified and as directed |
| 58 | S&F in repair 20mm dia gun metal globe or gate valve with iron wheel head screwed both ends for iron pipe complete all as specified and directed. |
| 59 | S&F in repair Low density poly ethylene pipes (LDPE) of pressure rating 6 kg/ cm2 Bore of pipes in 32mm,as waste pipe etc completed all as spd and directed. |
| 60 | S&F in repair 110mm bore PVC (SWR) Pipes single socketed, in any length with rubber ring joints,fixed to wall complete all as specified and directed. |
| 61 | S&F in repair 110mm bore PVC (SWR) Pipes single socketed, in any length with rubber ring joints,laid in trenches or in floors complete all as specified and directed. |
| 62 | S&F 110 mm bore PVC (SWR) bends any radius complete all as specified and directed. |
| 63 | S&F 110mm bore PVC (SWR) junction, single (Single T) equal or unequal complete all as specified and directed. |
| 64 | S&F 110mm bore PVC (SWR) vent cowl complete all as specified and directed. |
| 65 | S&F in repair 75 mm dia PVC (SWR) floor trap with grating including jointing with solvent cement complete all as specified and directed. |
| 66 | S&F in repair, 25mm dia, mild steel, decorative type, PVC coated, curtain rod with brackets complete all as per sample and as specified and directed. |
| 67 | S&F in repair brass chromium plated soap dish of approximate size 160mmx160mm x90mm fixed to plugs with chromium plated brass screws complete all as specified and as directed. |
| 68 | S&F in repair brass chromium plated tubular towel rail 20mm dia D type 60cm long between the flange fixed complete all as specified and directed. |
| 69 | S&F in repair 600mm x 450mm bevelled edge mirror of selected quality glass, mounted on 6mm thick AC plain building board or commercial ply wood and fixed to wooden plug with chromium plated brass screw and cup washers complete as directed. |
| 70 | Supply and fixing 1000 liters rotational moulded polyethylene water storage tank, triple layered (cylindrical vertical with closed top cover) as per IS-12701-1996, hoisted and fixed in position including necessary arrangements for fixing inlet, outlet & over flow pipe & provision of wash out pipe etc. complete as specified in SSR Part-I including dismantling of old existing water tank and removing from site complete all as specified and as directed. |
| 71 | M&L for 75 mm thick PCC 1:3:6 type C2 using 40mm graded stone agg as in sub base, finished even and fair w/o using extra cement complete all as specified and directed. |
| 72 | M&L for prepolished chequered cement concrete, coloured tiles,textured finished of size 250 x 250 x 25/ 300x300x25 mm thick set jointed in neat cement slurry and pointed with white cement and pigment in floors to match with colour of tiles, including 15mm thick screed bed in CM (1:6) complete all as specified and as directed. |
| 73 | E/M PORTION |
| 74 | Taking down carefully copper / Aluminium point wiring including (light, fan, socket or power complete fittings, such as switches, ceiling roses, pendant holders, Batten holders, shades conical fan regulators, light or power sockets etc) removing materials from site and making good disturbed surfaces of walls roofs etc complete all as specified and as directed. |
| 75 | Taking down carefully UNSV MCB DBs, SP/TP by unscrewing from main switch boards/cut out boxes and removing matrials to store for keeping in safe custody for reuse at site or for taking credit including sealing the cable ends and making good to disturbed surfaces of wall etc as per existing finishes complete all as specified and directed |
| 76 | M&L for concealed point wiring using approved colour coding (Red, Black and green for single phase circuits) complete with 1.5 Sqmm single core multistranded copper conductor PVC insulated and unsheathed FRLSH cable 1100 volts grade, IS-694 marked with valid CML No. and including drawn through non metallic rigid PVC Concealed conduit medium grade minimum of adequate size ISI-694 marked with valid CML No.(IS-9537-1983 for conduits and IS:3419:1976 for conduit accessories) and conduit accessories concealed in wall/roof/floor etc and chisselling on wall complete and including PVC insulated multi-starnded copper conductor 1.5Sqmm nominal cross sectional area single core cable as earth conduity conductor to common earth and connecting to earth dolly and making good the disturbed surfaces of wall / ceiling by cement mortar 1:4 complete all as specified and as directed at site for the following srl items :- |
| 77 | One light/ Fan point controlled by one no one way switch complete all as specified and as directed. |
| 78 | One 3 pin socket outlet, 5/6 Amps on independent board |
| 79 | One 3 pin socket outlet point, 5/6 Amps on same board |
| 80 | All as per item No.2.03 above but wiring with 2.5 sqmm PVC FRLSH insulated unsheathed cable with standed copper conductor for 6 pin6/16 Amp switch socket combination on independent board. |
| 81 | S&F Modular switch one way 5/6 Amp, 1 module, 240 Volts complete all as specified and as directed. |
| 82 | S&F Modular multipurpose socket outlet 2/3 pin, 5/6 Amps, 2 module 240 Volts complete all as specified and as directed. |
| 83 | S&F Modular switch, one way modular type, 15/16 Amp, 1 module, 240 Volts complete all as specified and as directed. |
| 84 | S&F Modular multipurpose socket outlet, 3 pin plug, 15/16 Amps, complete all as specified and as directed. |
| 85 | S&F bulb holder, angular PVC/ Polycarbonate suitable for batten fitting complete all as specified and as directed. |
| 86 | Supply and fixing ceiling rose surface bakelite two to three terminal 65 x 50 mm 250/230 volts ISI marked complete all as specified and as directed. |
| 87 | S&F LED tube light fitting, 1x20 watt, 220-240 volt, AC, inverter type with inbuilt rechargeable lithium battery back up for emergency operation, decorative box type complete with LED tube, electronic driver, holder, diffuser and automatic changeover during power failure with minimum of 04 hours battery backup suitable for wall/ceiling mounting including connecting up with three core flexiblwe copper conductor of suitable size from ceiling rose complete all as specified and as directed. |
| 88 | M&L for sub main wiring with 4 Sqmm (nominal area) with two runss (Red for phase and black for neutral) of single core FRLS PVC insulated and unsheathed cable with copper conductor 1100 volts grade (FRLS) ISI marked drawn in through and including non metalic PVC concealed conduit/ casing N Caping of adequate size but not less than 25mm width & accessories like bends, tee, etc fixed on recess of wall and ceiling and connecting to earth dolly and including single core 4 Sqmm earth wire, PVC insulated & unsheathed FRLS copper conductor green in colour duly connected to earth wire complete including taking down old sub main wiring complete all as specified and as directed. NOTE: 2 runs of main wire, 1 run of earth wire, 1 run of PVC Conduit with accessories shall be measured as one length. |
| 89 | S&F in repair MCB SPN distribution board in sheet steel enclosure GLAZED DOOR, 8 ways, double door, IP 43 protection, isolated neutral bar, insulated bus bar assembly, mechanical strength of IK09, fix with concealed wall including making good wall surface by plastering and civil work complete all as specified and as directed. |
| 90 | S&F MCB, SPN, 240 volts, 'C' Curve, 40 Amps, 10 KA, confirming to IS/IEC 60898-1 (ISI marked) complete all as specified and as directed. |
| 91 | S&F MCB, SP, 240 volts, 'C' Curve, 06 to 32 Amps, 10 KA, confirming to IS/IEC 60898-1 (ISI marked) complete all as specified and as directed. Please Enable Macros to View BoQ information |
| 92 | S&F MCB, SP, 240 volts, 'C' Curve, 06 to 32 Amps, 10 KA, confirming to IS/IEC 60898-1 (ISI marked) complete all as specified and as directed. Please Enable Macros to View BoQ information |