| 1 | Item Rate BoQ BoQ_Ver3.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) Tender Inviting Authority: Garrison Engineer (AF) Gorakhpur Name of Work:REPAIR/MAINT OF SEWAGE LINE, CLEANING OF SEWAGE LINES, SEPTIC TANKS, SOAKAGE WELLS, SUMP WELLS & MANHOLE COVERS AND REPAIR OF COMPOUND WALL, DRAINS,CULVERTS, CONCERTINA COIL, CHAIN LINK, FENCING, BARBED WIRE FENCING, POST AND STRUTS, GATES AND HARD STANDING IN AKASH VIHAR AREA AT AF STN GORAKHPUR UNDER GE(AF) GORAKHPUR. Contract No.: GE(AF)/GKP/E-13 OF 2026-27 File No. 9451/E8 Serial Page No.15 Name of the Bidder/ Bidding Firm / Company : PRICE SCHEDULE(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only ) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # Sl.No. Description of item Item Code / Make Quantity Units Estimated Rate inRs. P Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency BASIC RATE In Figures To be entered by the Bidder Rs. P Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e. DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit, if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT Without Taxes inRs. P TOTAL AMOUNT With Taxes TOTAL AMOUNT In Words |
| 2 | Demolition of cement concrete (unreinforced) in ground floors and roof and paving not exceeding 15 cm thickness (below or above ground level) .complete all as specified and directed at site. |
| 3 | Dismantling stone slab & tiles of any description or thickness in floors Complete all specified and directed |
| 4 | M&L 75mm thick cement concrete 1:4:8 type D2 using (40mm graded stone aggregate) as in sub base complete all as specified. |
| 5 | M&L in repair Chequered cement concrete coloured tiles with grey cement & pigment 20cm x 20cm x 25mm thick, set, jointed and pointed in neat cement slurry in floors laid over screed bed or beding layer of mortar 20mm thick in cement mortar 1:6 for laying floor finishes. all as specified and directed. |
| 6 | M&L 100mm thick cement concrete 1:4:8 type D2 using (40mm graded stone aggregate) as in sub base complete all as specified. |
| 7 | M&L in repair Machine pressed precast concrete interlocking paver block vibro compacted rubber moulded with grey cement and pigment any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand complete all as specified as directed. |
| 8 | M&L for refixing of Machine pressed precast concrete interlocking paver block vibro compacted rubber moulded with grey cement and no pigment any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand complete all as specified as directed. complete all as specified and directed by Engr-in-Charge. |
| 9 | M&L 100mm thick PCC 1:2:4 type B-1, using 20mm graded stone aggregate as in hard standing finished even and smooth without using extra cement complete all as specified. |
| 10 | M&L for preparation of new plaster surfaces of wall and applying two coats of cement base paint over a coat of alkali resistant primer complete all as specified as directed. |
| 11 | M&L for preparation of new plastered surfaces applying two coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10+E35 sqm over new surfaces. complete all as specified and directed. |
| 12 | M&L for preparation of old plaster surfaces of wall and applying two coats of cement base paint complete all as specified as directed. |
| 13 | Dismantling chain link fencing of any description complete all as specified and directed by Engineer-in-Charge. |
| 14 | Fixing only chain link M S galvanised fencing (IS-272) mesh as required but weight of mesh not exc 4.0 kg/sqm complete all as specified and directed. |
| 15 | Supply only chain link MS galvanised fencing, any size or type of minimum dia 3.15 mm or above including line wires complete all as specified & directed.Note:- weight of chian link fence shall be decided through BOO. |
| 16 | M&L in repair mild steel round bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips. |
| 17 | S&F in repairs Galvanised. 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails strain- ing bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc. complete all as specified and directed. |
| 18 | S&F in repair MS Posts and struts in fencing (any size of angle) mm including cutting tops to shapes as directed including driling holes for bolting of MS flat iron in horizontal, vertical & diagnal faces of each pannel to be intertwined with Chain link fencing, and fixed to posts with MS nut bolts and washers ,wind ties for sign board posts and struts, and similar work confirming to Fe 290 Gde E-165 complete al as spd and directed. |
| 19 | M&L preparation of new painted steel surfaces of any description, over 10cm width or girth and apply two coat of synthetic enamel paint over a coat of red oxide complete all as specified and as directed . |
| 20 | M&L plain cement concrete (1:2:4) type B-2 using 40mm graded stone aggregate in surface channels and drains complete all as specified and directed. |
| 21 | Extra for forming fair finished drain or channel up to 30 cm inner girth in cement concrete using extra cement incl forms, moulds, mitred/stopped ends etc. |
| 22 | S&F in repair of 610 mm dia punchhed tape concertina coil (effectve dia 550mm at stretch iength of coil 6 m) two hendle and spikes at bot ends of ends of coil with dove tail clipes (18 SWG ) including razor wire (07 No) 6m length in each wire width medium size ,barbed length 20 mm and barbed 14mm inclucding 51 pins 128 No of clips in each coil inluding 230 gm / sqm Zinc coating on core ire complete all as spd and directed. |
| 23 | Demolition of reinforced cement concrete cover slab for MH/Spetic tank( reinforcement cut as required to facilitate demolition) complete all as specified and directed at site. |
| 24 | M&L for PCC (1:4:8) type D-2, (using 40mm graded stone aggregate) as in foundation, mass fillings, mass concrete etc. complete all as specified & directed. |
| 25 | M&L for Precast RCC 1: 2:4 type B1 (nominal mix ) using 20mm graded stone aggregates as in drain/MH cover slab including necessary formwork etc complete all as specifide and directed . |
| 26 | M&L plain cement concrete (1:3:6) type C-2 using 40mm graded stone aggregate as in surface channels and drains complete all as specified and directed. |
| 27 | M&L plain cement concrete (1:2:4) type B-1 using 20mm graded stone aggregate as in coping complete all as specified and directed. |
| 28 | S&F 10mm diaTMT bars cut to legth, bent to shape required including cranking bending spirally for hooping for slab for manhole etc complete all as directed. |
| 29 | S&F 6mm to 8mm diaTMT bars cut to legth, bent to shape required including cranking bending spirally for hooping for slab for manhole etc complete all as directed. |
| 30 | Extra for forming fair finished drain or channel up to 30 cm inner girth in cement concrete using extra cement incl forms, moulds, mitred/stopped ends etc. |
| 31 | Demolition of brick work built in cement mortar, or cement lime mortar .complete all as specified and directed at site. |
| 32 | M&L Brick work with sub class B bricks straight or curved on plan exc 6m mean radius built in CM 1:6 complete all as specified and directed at site. |
| 33 | All as per Item No above but except bricks..complete all as specified and directed at site. |
| 34 | M&L for brickwork with subclass 'B' bricks, straight or curved on plan exc 6m mean radius in half thick brick walls built in cement mortar (1:4) complete all as specified and directed |
| 35 | Taking down cement or cement lime plaster any description on brick or stone walls, etc including raking out joints, hacking for key scrubbing down with water etc complete all as specified and directed |
| 36 | M&L Rendering 15mm thick in CM 1:4 on fair faces of brick work or concrete surfaces, finished even and smooth without using extra cement complete all as specified and directed |
| 37 | M&L for preparation of new plaster surfaces of wall and applying two coats of cement base paint with one coat of white cement primer on new surface complete all as specified as directed. Note - (Steel Grey Shade and tint shall be decided by the GE). |
| 38 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed |
| 39 | M&L Non skid joint less colour Ceramic tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15 mm thick cement mortar 1:6 bedding .complete all as specified and directed at site. |
| 40 | S&F Glazed ceramic coloured tiles 300x450x7mm thick in skirting dados risers to steps etc set and jointed in neat cement slurry and pointed in coloured cement to match tiles over 10mm thick cement plaster in cm 1:4 complete all as specified as directed.. |
| 41 | S&F in repair Vitreous China wash down water closet pan (pedestal pattern, with EWC including p or s trap ,seat cover , including connection to trap /drain and to flushing pipe anti syphonage pipe etc complete including making good floorcomplete all as specified as directed. |
| 42 | S&F in repair vitreous chaina squating pan orissa pattern size 580X 440mm white with intregal foot rest complete including lime concrete(excl flushing cistern and flush pipe) but connecting to flushing pipe, anti-symphonage pipe etc complete fixed in repair complete all as specified as directed. |
| 43 | S&F in replacement two way bib taps 15mm bore cast copper alloy chromiumplated fancy type with round head, screwed down, screwed for ironpipeor for brass ferruleandComplete all as specified and directed by Engr in Charge. |
| 44 | S&F in repairs Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete all as specified and directed. |
| 45 | S&F in repairs 10 Litre capacity PVC low level flushing cistern with ball valve and handle/push button 32mm dia PVC flush pipe including taking down unserviceable cistern complete all as specified and directed. |
| 46 | S&F in repairs 15 mm bore PVC connection 60cm long with brass nuts and washers on both ends all as in repairs specified and directed. |
| 47 | Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., including cleaning or refixing or removal to Store (measured overall as fixed along the centre line over fittings and accessories) |
| 48 | S&F for 110mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls all as specified & directed . |
| 49 | S&F for 110mm bore PVC (SWR) bends provided with access door all as specified & directed . |
| 50 | S&F for 75mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls , all as specified & directed . |
| 51 | S&F for 75mm bore PVC (SWR) bends provided with access door all as specified & directed . |
| 52 | S&Fin repair PVC (SWR) P or S trap 125/110 mm,setting and jointing with solventcement complete all specified and directed. |
| 53 | M&L in repair 75mm dia PVC (SWR) floor trap, plane with grating including jointing with solvent cement complete all specified and directed. |
| 54 | M&L for excavation in trenches n.exc 1.5M wide and n.exc 1.5M depth and n.exc 10 Sqm on plan and getting out in soft/loose soil (for manholes and sewage lines, drain etc.) .complete all as specified and directed at site complete all specified and directed. |
| 55 | M&L for returning filling in including spreading watering and well raming in layer . exc 25 cm each in loose/soft soil complete all as specified and directed. |
| 56 | M&L for removing excavated soil to a distance not exc 50 m and depositing where directed, complete all as specified and directed |
| 57 | Demolition and breaking up 150mm dia drain pipes ( salt glazed ware, AC or reinforced Concrete ) set in cement mortar complete all specified and directed. |
| 58 | M&L for concrete bed to drain pipes in PCC 1:4:8 type D2 using 40mm grade stone aggregate including packing under and haunching against the sides of pipe after they are laid and tested for the following 150mm bore pipe complete all specified and directed. |
| 59 | S&F Reinforced conctrete 150mm bore of pipes class NP2, laid and jointed complete with collars all as specified and directed. |
| 60 | Demolition and breaking up 200mm dia drain pipes ( salt glazed ware, AC or reinforced Concrete ) set in cement mortar complete all as specified. |
| 61 | M& L for Concrete bed to drain pipes in PCC 1:4:8 type D2 using 40mm grade stone aggregate including packing under and haunching against the sides of pipe after they are laid and tested for the following 200mm bore pipe. |
| 62 | S&F Reinforced conctrete 200mm bore of pipes class NP2, laid and jointed complete with collars all as specified and directed. |
| 63 | M&L for Cutting into existing manholes for connecting new drains and making good to pipe and rendering cutting out existing bending for and forming branch channel in cement concrete 1:2:4 type B1 smooth finished and reforming benching as required for pipe 150mm bore complete all as specified and directed. |
| 64 | Cleaning of chocked sewer line by diesel running vehicle mounting hydraulic operated high pressure suction cum jetting sewer cleaning machine fitted with pump having 4000 litres suction capacity and 6000 litres water jetting tank capacity including skilled operator, supervising engineer etc for cleaning and partial desilting of manholes and dechocking of sewer lines. Dechocking and flushing of sewer line from one manhole to another by high pressure jetting system of 2200 PSI for sewer line from 100 mm dia upto 200 mm dia for all depth complete all as specified and directed. |
| 65 | Material and labour for Cleaning/removal of blockage from bathroom,EWC/IWC (any type), kitchen, WHB and urinals including connected Nahani traps / gully traps/floor traps, grating of trap, waste pipes, pipe in any length upto first manhole etc choked with mud / other accumulated sludge and getting out, washing thoroughly at any location, at any floor by rodding/choke remover/Pressure technique/manually or otherwise to clear blockage upto entire satisfaction of users,including refixing of oval assess door covers with new nuts & washers and refixing manhole covers, including removing of all wastes, solid or liquid sludge and depositing the sludge in a pit (at empty/open area) of suitable size at a distance exceeding 50 metres from the building where directed and covering the same with the soil obtained from excavation of pit after treating the sludge by spreading the bleaching powder as directed to reduce the foul gases including all excavations and earthwork complete all as specified andas directed .(a) Contractor must employ Minimum 2 Nos labourers daily deployed in Akash vihar, complete all as specified and as directed . (b) Contractor or his representative shall report daily at 09.00 AM excluding on Sunday/ National holidays in the office of Engineer-in-Charge/ Complaint cell to receive complaint slip and necessary directions. Complaints received through telephonic message from JE/ Engineer-in-Charge shall also be attended on the same day and the completion of work shall be reported by 05.00 PM of every working day to JE/ Engineer-in-Charge. (c) In case of non attedence of complaints by contractor on the same day, a penalty of Rs 50/- per complaint per day will be recovered from the contractor due RARs. (d) The cost for all necessary T&P such as bamboo strips, iron rods, sewage rodding machine, buckets, rope, ladder, safety mask, bleaching powder etc and all other other materials for execution of the work shall be included in the unit rate complete all as specified and as directed . (e) A complaint register shall be maintained by JE and proper record of complaints received and attended with date and time shall be recorded and signed daily by both the parties. After complete the work, the register shall be kept on record of Engineer-in-Charge for further complete all as specified and as directed . |
| 66 | Cleaning of septic tanks / Manholes including bailing out water, from it and removing sludge and blockages from inlet and outlet of sewer lines including taking out the excavated sludge and carting away the same to a distance far away from residential/office area and cover the same with fresh earth and recommissioning the septic tank including site clearance to a distance of 5 km around septic tank complete all as specified and directed for the following capacity :- (a) For Manhole n. exc 1.50m deep. |
| 67 | (b) For Manhole exc 1.50m but n.exc 3m deep. |
| 68 | (c) For septic tank of 25 to 50 user capacity. |
| 69 | (d) For septic tank of 50 to 100 user capacity. |
| 70 | Dewatering of septic tank, sump wells, grease traps including bailing out water with mechanical device like super sucker machine, high pressure jetting machine, from it and removing sludge and blockages from inlet and outlet of sewer lines including taking out the excavated sludge and carting away the same to a distance far away from residential/office area and cover the same with fresh earth and recommissioning the same including site clearance to a distance of 5 km around complete all as specified and directed. |
| 71 | S&F in repair CP Grating 125 mm size complete all as specified as directed. |
| 72 | S&F in repair vitreous china urinal half stall type white complete including providing and fixing plugs,etc all fittings including spreader (Exclusive of fixing supply pipe to flushing cistern, trap and waste pipe) complete all as specified and directed. |
| 73 | S&F in repair PVC waste pipe 32/40mm dia for wash basin/sink/urinal ISI marked complete all as specified and directed. Total in Figures 0.0 0.0 INR Zero Only 4.0 Construction of chamber for 100mm sluice plates item5 10.0 Nos Quoted Rate in Figures Select 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information |