| 1 | Demolition of Reinforced cement concrete of any description and in any position not otherwise specifically provided for complete all as specified and as directed |
| 2 | Separating, scraping and cleaning of reinforcement (Demolition of concrete measured separately) complete all as specified and as directed |
| 3 | Removing of demolished RCC debris/roacks exc. 250m but n.exc 500M and depositing where directed at a level n.exc 1.5M above the starting point complete all as specified and as directed |
| 4 | M&L for brickwork with sub class `B` bricks, in straight or curved on plan exc 6m mean radius, built in CM 1:6 complete all as specified and as directed |
| 5 | Taking down steel tubing and connections including removing from site of 15mm bore pipe complete all as specified and as directed |
| 6 | Description same all as per item No 5 here-in-above but 20mm bore complete all as specified and as directed |
| 7 | S&F for 15mm bore steel water tubing medium grade , galvanized ISI marked with all fittings fixed to wall & ceiling or laid in floors complete all as specified and as directed |
| 8 | Description same all as per item No 7 here-in-above but 20mm bore complete all as specified and as directed |
| 9 | Description same all as per item No 7 here-in-above but 40mm bore complete all as specified and as directed |
| 10 | S&F in repair 110mm dia PVC SWR pipes of pressure 6kgf/cm2 fixed complete to walls ceilings, in floors etc including all necessary fitting arrangements etc in rainwater pipe complete all as specified and as directed |
| 11 | S&F for PVC stack clamps out of suitable for 110 mm bore dia SWR pipe including bolts and nuts and securing ends of stays to wall or roofs complete all as specified and as directed |
| 12 | S&F for PVC SWR (110) bends any radius complete all as specified and as directed |
| 13 | Supply only Integral waterproofing compound complete all as specified and as directed |
| 14 | S&F for triple layer black/white colour rotational moulded vertical water storage tanks with closed tops ( cylinderical) with cover, hoisted and fixed in position 500 ltr capacity complete all as specified and as directed |
| 15 | Dismantling of brick tiles laid bedded and pointed in any morter or brick tiles on roof of any description including leeping or any other treatment over roof complete all as specified and as directed |
| 16 | Demolition of cement concrete of any description and in any position not otherwise specifically provided any thickness including plastering and leeping (whether full thickness removed or only a part thereof) complete all as specified and as directed |
| 17 | M&L for cement concrete PCC (1:2:4) Type-B-1, using 20mm graded aggregate in coping, bedding, leveling course, bed plate, tank staging etc complete all as specified and as directed |
| 18 | M&L for bedding layer 10mm thick in cement mortar (1:3) cover concrete surfaces of roof, mixed with @ 200ml liquid water proofing compound by 50Kg weight of cement (1 bag) as per manufacturerrs instruction inclduing finishing surfaces even and smooth without using extra cement complete all as specified and as directed.Note : WPC shall be measured and paid separately. |
| 19 | M&L for preparation of new surface and applying a coat of hot blown bitumen of grade 85/25 conforming to IS 702 over and including cleaning the dust,dirt and any other foreign material from roof surface and applying a coat of bituminous primer @ 0.40 ltr / Sqm uniformily and primer shall be allowed to dry as conforming to IS 3384-1986 primed surface of roof slab @ 1.20 Kg/Sqm complete all as specified and as directed |
| 20 | M&L for APP based polymeric water proofing membrane minimum weight 3 Kg/ Sqm and minimum 3mm thick reinforced with polyster non wove fabrick (Weight not less than 150gms/Sqm or as per IS), laid over hot bitumen surface by torched application with the strict supervision of technical supervisor. Membrane shall be laid with 100mm side/end lap on prepared surface as per manufacturer instruction work shall be carried out strictly with the technical tradesmen complete all as specified and as directed |
| 21 | M&L for 40mm thick brick tiles laid on cement mortar 1:6 and grouted flush in CM (1:3), mixed with 5% of crude oil by weight of cement on 15mm thick screed bed in CM (1:6) complete all as specified and as directed |
| 22 | Description same all as per item No 21 here-in-above but except Tiles, complete all as specified and as directed |
| 23 | M&L for preparation and applying two coats of Aluminium paint over a coat of hot blown bitumen of grade 85/25 conforming to IS 702 @ 1.20 Kg/Sqm a coat of bituminius primer @ 0.30 liters per square meter uniformily on APP membrane complete all as specified and as directed |
| 24 | S&F for 20mm bore brass ball/ float valves high pressure with polythene float and flynut and epoxy coated aluminium rod & high density plastic ball screwed for iron pipe and fixed complete all as specified and as directed |
| 25 | S&F for stop Valve / Gate Valve 20 / 25mm dia cast copper alloy, screwed down, high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and as directed |
| 26 | S&F for stop Valves/Gate valves 15 mm dia cast copper alloy,screwed down, high pressure with crutch or butterfly handel, screwed both ends for iron pipe or for unions and fixed complete all as specified and as directed |
| 27 | Schedule of Credit (MINUS) Rs. 1,78,000.00 B/F from Serial Page No. [Note : Details of items for schedule of credit is given on Srl Page No. _____] This amount shall be automatically deducted to arrive at tendered sum Please Enable Macros to View BoQ information |