| 1 | Construction of Building |
| 2 | 15.17.1:Dismantling steel work in single sections including dismembering and stacking within 50 metes lead in:R.S. Joists |
| 3 | 50.6.1.4:Solid block masonry using pre cast solid blocks (Factory made) of size 30x20x20cm or nearest available size confirming to IS 2185 part I of 1979 for foundation and plinth with thickness 20cm and above in: CM 1:6 ( 1 cement : 6 coarse sand ) etc complete |
| 4 | 5.1.3:Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 5 | 5.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more |
| 6 | 50.12.4.2:Providing and fixing false ceiling with 7.5 mm thick PVC wooden grains panel board ceiling of approved quality in aluminium frame work with necessary screws etc complete ( aluminium frame work shall be paid separately) |
| 7 | 21.5:Providing and fixing powder coated aluminium work ( minimum thickness of powder coating 50 micron) consisting of tee /angle sections, of approved make conforming to IS : 733 in frames of false ceiling including aluminium angle cleats with necessary C.P brass/ stainless steel sunk screws, aluminium perimeter angles fixed to wall with stainless steel rawl plugs @ 450 mm centre to centre and fixing the frame work to G.I level adjusting hangers 6 mm dia. with necessary cadmium plated machine screws all complete as per approved architectural drawings and direction of the Engineer-in-Charge ( level adjusting hangers, ceiling cleats and expansion hold fasteners to be paid for separately ). |
| 8 | 13.61.1:Painting with synthetic enamel paint of approved brand and manufacture to give an even shade:Two or more coats on new work |
| 9 | 10.16.1:Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Hot finished welded type tubes |
| 10 | OD38308/2026-2027:Providing and fixing aluminium profile sheet(size ,shape, and pitch of corrugates as approved by engineer) 0.46 mm or nearest available thickness. The sheet shall be fixed using self drilling , self tapping series of size (5.5x5.5 mm) EDPM seal complete cutting etc ( OD 71/21-22 Approved Data CE circular Dated 18-08-2016 ) |
| 11 | 10.28:Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) |
| 12 | OD38306/2026-2027:Designing, fabricating,testing and installing Curtain Wall with Aluminium CompositePanel Cladding, with open grooves for linear as well as curvilinear portions of the building , for all heightsand all levels etc. including:Providing, fabricating and supplying and fixing panels of aluminium composite panel cladding INCLUDINGaluminium base frame work in pan shape in metalic colour of approved shades made out of 3mm thickaluminium composite panel material. The aluminium composite panel cladding sheet shall be coil coated,with Kynar 500based PVDF / Lumiflon based fluoropolymer resin coating of approved colour and shade onface # 1 and polymer (Service) coating on face # 2 as specified using stainless steel screws, nuts, bolts,washers, cleats, weather silicone sealant, backer rods etc.with aluminium composite panel cladding till thehanding over of the building for occupation. The Contractor shall provide curtain wall with aluminiumcomposite panel cladding, having all the performance characteristics all complete, as per the Architecturaldrawings, as per item description, as specified, as per theapproved shop drawings and as directed by theEngineer-in-Charge.However, for the purpose of payment, only the actual area on the external face of thecurtain wall with Aluminum Composite Panel Cladding (including width of groove) shall be measured in sqm.up to two decimal places.OD86/21-22 - Modified data 25.7 |
| 13 | OD38305/2026-2027:Supply and fixing multiwood with acrylic letters of 20mm thick including all material charges, fixing, conveyance etc complete as per the direction of departmental officers. |
| 14 | 11.37:Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete |
| 15 | 4.1.3:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand (zone-III)derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) Please Enable Macros to View BoQ information |