Tender For Completion Of Incomplete Work For Provision Of Otm Accn & Allied Facilities At Along Under Cce (Army) No 1, Dinjan Serial Page No.
Tender Value
8.13 Crore
Estimated cost
Bid Submission
21 Jul 2026
20 days left
EMD
15 Lakhs
Bank guarantee accepted
Document Fee
3000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
West Siang → Arunachal Pradesh
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Completion Of Incomplete Work For Provision Of Otm Accn & Allied Facilities At Along Under Cce (Army) No 1, Dinjan Serial Page No.
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 18-Jun-2026 | Timeline details amendment | Date | 21-Jul-2026 |
BOQ
| Sl. No. | Item Description |
| 1 | BoQ_Ver3.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) Tender Inviting Authority: HQ Chief Construction Engineer (Army) No. 1 Dinjan, Military Engineer Services Name of Work: COMPLETION OF INCOMPLETE WORK FOR PROVISION OF OTM ACCN & ALLIED FACILITIES AT ALONG UNDER CCE (ARMY) NO 1, DINJAN Serial Page No. Contract No: CCE/DIN/ALONG/03/2026-27 Bidder Name : SCHEDULE 'A'(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only ) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # NUMBER # Srl.No. Item Description Item Code / Make Quantity Unit Estimated Amount (for Prepriced Schedule only) Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency Rate in Figures To be entered by the Bidder Rs. P Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT TOTAL AMOUNT With Taxes TOTAL AMOUNT in Words Quoted amount in form of Percentage (%) Above or Below wrt Estimated amount (for Prepriced Schedule only) |
| 2 | Total amount of Sch 'A' Part I (Building and Structure) (Pre Priced Amount as in Col 7, brought forward from Total of Sch 'A' Part-I) |
| 3 | Total amount of Sch 'A' Part II (Dismantling and Demolition of Buildings) (Pre Priced Amount as in Col 7, brought forward from Total of Sch 'A' Part II) |
| 4 | Total amount of Sch 'A' Part III (Site Clearence, Earth Work And Area Development) (Pre Priced Amount as in Col 7, brought forward from Total of Sch 'A' Part III) |
| 5 | Total amount of Sch 'A' Part IV (Retaining Wall (For Height Upto 5.5 M) (Pre Priced Amount as in Col 7, brought forward from Total of Sch 'A' Part IV) |
| 6 | Total amount of Sch 'A' Part V (Internal Electrification and Lightning Protection) (Pre Priced Amount as in Col 7, brought forward from Total of Sch 'A' Part V) |
| 7 | Total amount of Sch 'A' Part VI (Internal Water Supply) (Pre Priced Amount as in Col 7, brought forward from Total of Sch 'A' Part VI) |
| 8 | Total amount of Sch 'A' Part VII (Road / Path / Culvert) (Pre Priced Amount as in Col 7, brought forward from Total of Sch 'A' Part VII) |
| 9 | Total amount of Sch 'A' Part VIII (External Electrification) (Pre Priced Amount as in Col 7, brought forward from Total of Sch 'A' Part VIII) |
| 10 | Total amount of Sch 'A' Part IX (External Water Supply) (Pre Priced Amount as in Col 7, brought forward from Total of Sch 'A' Part IX) |
| 11 | Total amount of Sch 'A' Part X (Sewage Disposal) (Pre Priced Amount as in Col 7, brought forward from Total of Sch 'A' Part X) |
| 12 | Total amount of Sch 'A' Part XI (Area Drainage) (Pre Priced Amount as in Col 7, brought forward from Total of Sch 'A' Part XI) |
| 13 | Total amount of Sch 'A' Part XII (Fencing and Gate) (Pre Priced Amount as in Col 7, brought forward from Total of Sch 'A' Part XII) |
| 14 | Total amount of Sch 'A' Part XIII (Solar Water Heating System) (Pre Priced Amount as in Col 7, brought forward from Total of Sch 'A' Part XIII) |
| 15 | DISMANTLING AND DEMOLITION OF BUILDINGS (SCHEDULE 'A' PART-XV) |
| 16 | Taking down old copper / aluminium point wiring (light, fan socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fittings etc, complete all as specified and directed. |
| 17 | Taking down ceiling fan / exhust fan, of any size and capacity and deposite to MES store yard complete all as specified and directed. |
| 18 | Taking down MCBs DB and connected service cable of any type, capacity and size complete all as specified and directed. |
| 19 | Taking down geyser of capacity upto 25 Lts in any position and situation and deposite to MES store5 yard complete all as specified and directed. |
| 20 | INTERNAL ELECTRIFICATION & LIGHTENING PROTECTION:- |
| 21 | Supply and fix flame proof / weather proof rotary on /off switch complete all as specified and directed |
| 22 | M & L for concealed flush to wall factory made sheet metal enclosure for MCB DBs, Manufactured prewired double door designed, DB's VTPN 415V 12 way 63 Amp fixed on wall / MS box complete with 250 Amps neutral link dinrail suitable for mounting MCCB's complete, IP-54 protection complete all as specified and directed. |
| 23 | M & L for concealed flush to wall factory made sheet metal enclosure for MCB DBs, manufactured prewired double door designed, DB's VTPN 8 way 63 Amp fixed on wall / MS box complete with 250 Amps neutral link dinrail suitable for mounting MCCB's complete, IP-54 protection complete all as specified and directed. |
| 24 | S & F LED tube light 22 Watt Delite Plus LED Tube Light , 6500K Surface / Recess mounted Decorative ultra slim aluminium square profile LED lighting fixture with high lumen output 100 Lumen per watt, environmental friendly, energy efficient, etc complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and directed. |
| 25 | S & F LED Tube Light 20 Watt E-Lite LED Pride Plus 100 Lumen per watt, 6000K Surface/Recess mounted Decorative ultra slim aluminium square profile LED lighting fixture with high lumen output, environmental friendly, energy efficient, etc complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and directed. |
| 26 | S & F flame Proof LED 20 Watt CMRI Certified LED Flameproof suitable for Gas / Vapor Group of IIA & IIB and Zone 1 & 2. IP65 Protection, complete with all accessories prewired and including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and directed |
| 27 | S & F LED Tube Light 18 Watt E-Lite LED Pride Plus 100 Lumen per watt, 6000K Surface/Recess mounted Decorative ultra slim aluminium square profile LED lighting fixture with high lumen output, environmental friendly, energy efficient, etc complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and directed. |
| 28 | S & F LED Tube Light 2x18 Watt Magnum Retro, long life, corrosion resistant, impact proof, surface mounting IP65 luminaire with PC housing & opal finish cover suitable for LED tubes, etc complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and directed Make- Crompton or equivalent make as approved by PM. |
| 29 | S & F Bulk Head with 10W LED Light with all accessories suitable for fitting and including connecting up with twin core twisted flexible copper conductor cable with suitable size of 230V, 50Hz complete all as specified and directed. |
| 30 | S & F 6 Watt LED Light for mirror 4000K at 100 Lumen per watt AC 170-240V, complete with all accessories prewired and including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and directed. |
| 31 | S & F 24W Recess mounted Downlighter with pressure die-cast aluminium heat sink & PC diffuser in white powder coated finish with integrated driver. Product desvription 24W 830 complete with all accessories prewired and including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and directed. Make- Havells or equivalent make as approved by PM |
| 32 | S & F 15 Watt EDGE Plus Series LED Street Light pressure die cast housing with toughened glass and individual LEDs with secondary optics and IP65 Protection, complete with all accessories like GI Pipe suitable for fitting and including connecting up with twin core twisted flexible copper conductor cable with suitable size of 230V, 50Hz. complete all as specified and directed. |
| 33 | S & F HD 750 mm sweep (SS-390 Metallic) ceilling fan including cost of material, labour and T & P as per drawing complete, for proper completion of work complete all as specified and directed. Make:- Crompton/Khatian/Havells/Orient |
| 34 | S & F Telephone Jack Modular with Shutter Type fixed on 2 Module white cover plate with fram, 2 Module metal flush Box complete all as specified and directed. |
| 35 | S & F drawing twin core telephone wire 0.5mm in PVC conduit of 25mm size complete in all respect, including cost of material, labour and T & P as per drawing complete all as specified and directed. |
| 36 | S & F T.V Socket with Shutter Type fixed on 2 Module white cover plate with fram, 2 Module metal flush Box completedrawing 25mm dia PVC concealed conduit connection complete in all respect complete all as specified and directed. |
| 37 | S & F Co-Axial TV Cable Electrolytic grade solid annealed Copper conductor, JF, Al wire Braided (RG-6 Foam type) in PVC conduit of 25mm size complete in all respect complete all as specified and directed. |
| 38 | ROAD / PATH / CULVERT :- |
| 39 | M & L for applying 3mm thick retro reflective thermoplastic road marking paint using thermoplastic road marking compound, conforming to MORTH, AAHTO M249 and BS 3262 with 30-40% pre mixed glass beads conforming to BS 6088, on existing road surfaces including preparation of surface complete all as specified and directed. |
| 40 | S & F Cat Eyes / Glow studs of size 100x100x20mm, made of heavy duty body fixed on the road as per manufacturer's instruction complete all as specified and directed.. |
| 41 | S&F Sign boards on road as 900mm x 600mm size, as per IRC made out of 2.0mm thick aluminium sheet with front face of aluminium sheet to be fully covered by white diamond grade micro prismatic type 1 x Retroreflective sheeting matter by over lay red colour film and back side painted with grey appoxy paint including fixing provision of 1 post of MS pipe 75mm dia 3.80m long dully painted in black and white alternate bands of synthetic enamel paint and hold fast at bottom complete in all respects all as approved by PM complete all as specified and directed. |
| 42 | EXTERNAL ELECTRIFICATION :- |
| 43 | Supply, install, testing and commissioning of HT 11 KV, 18.4 KA, 3 Phase, 50 Hz 3 wire totally enclosed metal clad ,extensible type indoor floor mounted horizontal draw out type with roll on floor, horizontal isolation type Vacuum Circuit Breaker 400 Amps motor operated spring charged having rupturing capacity 250 MVA and consisting of the following :- 01No 11KV, 400 Amps, VCB comprising of :- (i) Assembly of 3 vaccum interrupters complete with epoxy support insulator and self-aligning finger type isolating contacts. (ii) Hand and motor(220 volt AC) charged independent spring closing/tripping trip free operating mechanism with manual closing and tripping push buttons and mechanical breaker closed /open, spring charged/discharged indication. (iii) Electrical release coil 24V DC- 01 No (iv) Mechanical operation counter. (v) Breaker operated auxiliary switch-03 Nos (vi) Bus bar chamber including a set of 3 phase 630 Amp copper bus bar -01 No (vii) 230 volts AC single phase 80 W rated strip type heater -02 Nos with indicator complete. (viii) Voltage transformer (VT) incorporating 3 phase 3 limb with drawable type VT having ratio 11KV/110V and output of 100 VA per phase with accuracy class I as per IS-3155 complete with HT and LT HRC fused n primary and secondary sides respectively (confirming related IS specification) -02 set . (ix) Current transformer (CT) chamber incorporating 3 single phase resin cast, dual ratio CTS of ratio 40/20/5 Amp with suitable VA burden and accuracy class. (j) Rear cable termination provision for terminating 3 core 120 sq. mm XLPE cable. (x) Ammeter dual range with selector switch size 144 sq. mm 0 20/10A.(l) Voltmeter with selector switch . Note : SOP and safety precaution to operate the main HT & LT sub station to be fixed on wall in English and Hindi in font size 16 pt (or 5.6mm) Each |
| 44 | (xi) Triple pole non-directional IDMT relays having minimum 02 element for over current setting 50% -200% and one element for earth fault protection setting 20%-80% with instruments high set element -01 (xii) On/Off /Trip Indication-01(xiii) TNC Switch-01 (xiv) 3 Phase RYB indications with lamp & holder - 01 set with cable glands of suitable size (xiii) Trip circuit healthy indication lamp with push button-01 (xv ) Power factor meter digital type-01 (xvi) Frequency meter -01 (xvii) Cable gland of suitable size (xviii) Shunt trip 24 volts DC including maintenance free battery bank, battery charger (xix) In built integral earthing (xx) Electronic, digital KWH meter CT type suitable for metering CT-01 No. complete all as specified and directed. Make Crompton/Schneider/ABB/ITE Gurgaon |
| 45 | Supply and installation of 11 KV single phase in door resin cast CT draw type of ratio 400/200/5- 5A class 1.0/ 5P10,burden 15VA – 15 VA, including all connection complete all as specified and directed. |
| 46 | Supply and installation of 11 KV single phase in door resin cast PT (Potential transfer) draw type of ratio 11 KV/rt3/110 V/rt3/110V/rt3,Class 0.5-3, Burden 50 VA – 50 VA with associated gun type HRC fuse and MCB or HT/LT isolation, including cost of material, labour including making all connection complete all as specified and directed. |
| 47 | Supply and fix HT 11 KV, out door type triple pole mounted on polymer based insulator with expulsion fuse set single pole drop out type incl expulsion fuse carriers and fuse elements upto 25 Amp and fitted on suitable for horizontal / vertical mechanically operated mechanism from ground level consisting of operating load of 25mm bore heavy grade GI pipe of suitable length worked from ground level and with locking arrangement incl pad lock with key flat iron with clamp 50mm x 6mm complete gang operated air-break switch suitable for horizontal or vertical complete with 9 insulators of rating upto 200 Amps, complete all as specified and directed. |
| 48 | Supply and fix lightning arrestor HT 11 KV 10 KA station class, duly fixed on two pole structure complete all as specified and directed. |
| 49 | Supply & install, testing and commissioning indoor type 30 Volts battery bank including charger suitable for and including 15 C Batteries of 120AH input supply single phase 230 volts and output Float 24-35 Volts DC @10 A, Boost 29 Volts at power factor 0.8 and degree of protection IP 4X, complete internal wiring with suitable copper condutor wires and each battery & charger should be mounted in the same panel with suitable ventilation, floor mounting panel fabricated out of 2 mm thick CRCA sheet with suitable angle iron frame and legs made of suitable angle iron, painted with powder coated and pre coted primer including with locking arrangement complete all as specified and directed by Engr-in-Charge. Make : ABB/Schnieder/Seimens/ L & T |
| 50 | Supply, installation testing and commissioning of digital UPS system for power back up single phase AC input 140V to 270V and out put 220V + 10% capacity 4 KVA including 02 Nos , 12V batteries of 150 AH, VRLA (Valve regulated lead acid batteries with interconnection cables and battery rack complete all as specified and directeed. |
| 51 | Supply & laying Synthetic Insulating mat of size 2.00Mtr x 1.00Mtr x 3 mm thick or as per latest IS complete all as specified and directed . |
| 52 | Supply and fixing 40 mm dia GI pipe for street light bracket on LT pole \\"medium grade\\" of 1.5 mtr long and make to shape fixing with suitable size of flat iron clamp nut , bolts and washers connection including two coat of synethetic enamel paint over a coat of red oxide zinc chrome primer and fixing the light fitting on bracket and all the electrical connection complete all as specified and directed. |
| 53 | Supply and fixing LED street light fitting 45 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed. |
| 54 | Supply installng testing and commissioning of factory made and tested CPRI approved LT panel board, indoor type, platform mounted suitable for 415 Volts 3 phase 4 wire, 50 HZ AC supply , having bus bar chamber wih insulated aluminium bus barsof 600 Amp insulated on porcelain insulators. The panel shall be dust and vermin proof, IP 54 class protection and made of 2mm CRCA MS Sheet and 50 x 50x 6mm thick angle iron frame work, powder coated finish fronback opening type, with aprons for cable entry from bottom and fixing 02 Nos danger notice plate with letter , figures and conventional skul bones in signal red colour and fixed front & back door LT panel etc with voltage and danger indicated in Hindi and English with double door shutter and lockingarangement , internal wiring with PVC insulated, stranded copper conductor, FRLS cable, IS-694 marked of adequate size but not less than 2.5 Sqmm. The platform shall be such that of size 16 to 400 Sqmm and compising of the following: (for transformer No-01 (200 KVA)(a) Bus bar chamber of 3 phase and neutral 4 strip 415 volts with 600 Amps Aluminium - 1 set (a)3 Phase 4 wire 50 Hz MCCB 4 Pole 415 V 400 Amps, 35 kA -2 Nos. (Incoming) (b) Ammeter 0- 1000 Amps 96 mm x 96mm electro mechancial type with three way ON/OFF rotary type selector switch and 3 current transformer of suitable ratio and capacity Qty 1 No (c) Indicating lamps for three phases Qty 1 set of 3 Nos |
| 55 | (d) Voltmeter 0 - 500 Volts 96 mm x 96mm electro mechanical type with 3 way ON/OFF rotary type selector switch - Qty 01 No make AE/Rishab /Meco/Enercon). Outgoing:- (a) 4 pole MCCB 63 Amp 50 HZ 415 V,25 kA-1 no. (b) 4 pole MCCB 160 Amp 50 Hz 415 V, 35 kA - 01 no. (c). 4 pole MCCB 100 Amp 50 Hz 415 V, 35 kA - 01 no (d) TPN 40 Amp , 50 HZ 415 V, 35 kA -01 No(e). On load Change over Switch of capacity 400Amp - 1 No. (f). MCCB 400 A, 36 kA - 1 No. , including cost of material, labour and T & P as per drawing complete, for proper completion of work all as specified and directed.. (d) Platform of panel :- platform for the panel with PCC 1:4:8 type D2 with 40mm graded crushed stone , 15cm thick in foundation, brick work in CM 1:6 with sub class 'B' old size bricks, rendering 15cm thick in in CM 1:6 on exposed surfaces and 100mm thick PCC padding 1:3:6 type -1 using 20mm graded crushed stone aggregate on toop and grouting bolts etc for panel The The various feeders shall be indicated by 50mm size letters in synthetic enamel white paint.The platform shall be such that it is of a height 45 cm above the nearest road level.Notes :- (i) All termination of existing cable should be provided with aluminium/thimbles and suitable size of glands & rate for the same is deemed to be included in the item (iii) Provision of one spare MCCB and one spare MCB chamber in panel to be made for future extension. (iii) The various feeders shall be indicated by 50mm size letters in synthetic enamel white paint. |
| 56 | Supply installng testing and commissioning factory made and tested CPRI approved LT panel board, outdoor type, canopy headed, platform mounted suitable for 415 Volts 3 phase 4 wire, 50 HZ AC supply , having bus bar chamber wih insulated aluminium bus bars of cap 250 Amp insulated on porcelain insulators. The panel shall be dust and vermin proof, IP 65 class protection and made of 3.15mm CRCA MS Sheet and 50 x 50x 6mm thick angle iron frame work, powder coated finish fronback opening type, with aprons for cable entry from bottom and fixing 02 Nos danger notice plate with letter , figures and conventional skul bones in signal red colour and fixed front & back door LT panel etc with voltage and danger indicated in Hindi and English with double door shutter and lockingarangement , internal wiring with PVC insulated, stranded copper conductor, FRLS cable, IS-694 marked of adequate size but not less than 2.5 Sqmm. The platform shall be such that of size 16 to 400 Sqmm and compising of the following: (Location E) (a)MCCB 4 pole 415 V 160 Amps.35 KA Adjustable type -2 No (01 Spare) (Incoming) (b)Ammeter 0- 500 Amps 96 mm x 96mm electro mechancial type with three way ON/OFF rotary type selector switch and 3 current transformer of suitable ratio and capacity Qty 1 No (c) Indicating lamps for three phases Qty 1 set of 3 Nos (d) Voltmeter 0 - 500 Volts 96 mm x 96mm electro mechanical type with 3 way ON/OFF rotary type selector switch - Qty 01 No make AE/Rishab /Meco/Enercon). |
| 57 | Outgoing:- (a) 4 pole MCCB 63 Amp, 50 HZ 415 V-02 nos. (b). 4 pole MCCB 40 Amp, 50 HZ 415 V-01 no. (c) TPN 40 Amp , 50 HZ 415 V -01 No , including cost of material, labour and T & P as per drawing complete, for proper completion of work all as specified and directed.(d) Platform of panel :- platform for the panel with PCC 1:4:8 type D2 with 40mm graded crushed stone , 15cm thick in foundation, brick work in CM 1:6 with sub class 'B' old size bricks, rendering 15cm thick in in CM 1:6 on exposed surfaces and 100mm thick PCC padding 1:3: 6 type -1 using 20mm graded crushed stone aggregate on toop and grouting bolts etc for panel The The various feeders shall be indicated by 50mm size letters in synthetic enamel white paint.The platform shall be such that it is of a height 45 cm above the nearest road level.Notes :- (i) All termination of existing cable should be provided with aluminium/thimbles and suitable size of glands & rate for the same is deemed to be included in the item (ii) Provision of one spare MCCB and one spare MCB chamber in panel to be made for future extension. (iii) The various feeders shall be indicated by 50mm size letters in synthetic enamel white paint. |
| 58 | Supply installng testing and commissioning factory made and tested CPRI approved LT panel board, outdoor type, canopy headed, platform mounted suitable for 415 Volts 3 phase 4 wire, 50 HZ AC supply , having bus bar chamber wih insulated aluminium bus bars of cap 100 Amp insulated on porcelain insulators. The panel shall be dust and vermin proof, IP 65 class protection and made of 3.15mm CRCA MS Sheet and 50 x 50x 6mm thick angle iron frame work, powder coated finish fronback opening type, with aprons for cable entry from bottom and fixing 02 Nos danger notice plate with letter , figures and conventional skul bones in signal red colour and fixed front & back door LT panel etc with voltage and danger indicated in Hindi and English with double door shutter and lockingarangement , internal wiring with PVC insulated, stranded copper conductor, FRLS cable, IS-694 marked of adequate size but not less than 2.5 Sqmm. The platform shall be such that of size 16 to 400 Sqmm and compising of the following: (Location C ) (a)MCCB 4 pole 415 V 63 Amps, 25 kA -2 Nos (1 Spare) (Incoming) (b)Ammeter 0- 500 Amps 96 mm x 96mm electro mechancial type with three way ON/OFF rotary type selector switch and 3 current transformer of suitable ratio and capacity Qty 1 No (c) Indicating lamps for three phases Qty 1 set of 3 Nos (d) Voltmeter 0 - 500 Volts 96 mm x 96mm electro mechanical type with 3 way ON/OFF rotary type selector switch - Qty 01 No make AE/Rishab /Meco/Enercon). |
| 59 | Outgoing:- a) 4 Pole MCCB 40 Amp, 50 Hz 415 V, 25 kA -02 Nos, including cost of material, labour and T & P as per drawing complete, for proper completion of work and as per direction of Engineer in Charge. (d) Platform of panel :- platform for the panel with PCC 1:4:8 type D2 with 40mm graded crushed stone , 15cm thick in foundation, brick work in CM 1:6 with sub class 'B' old size bricks, rendering 15cm thick in in CM 1:6 on exposed surfaces and 100mm thick PCC padding 1:3:6 type -1 using 20mm graded crushed stone aggregate on toop and grouting bolts etc for panel The The various feeders shall be indicated by 50mm size letters in synthetic enamel white paint.The platform shall be such that it is of a height 45 cm above the nearest road level.Notes :- (i) All termination of existing cable should be provided with copper lugs/thimbles and suitable size of glands & rate for the same is deemed to be included in the item (iii) Provision of one spare MCCB and one spare MCB chamber in panel to be made for future extension. (iii) The various feeders shall be indicated by 50mm size letters in synthetic enamel white paint. |
| 60 | Supply installng testing and commissioning of factory made and tested CPRI approved LT panel board, indooor type, platform mounted suitable for 415 Volts 3 phase 4 wire, 50 HZ AC supply , having bus bar chamber wih insulated aluminium bus barsof 1200 Amp insulated on porcelain insulators. The panel shall be dust and vermin proof, IP 54 class protection and made of 2mm CRCA MS Sheet and 50 x 50x 6mm thick angle iron frame work, powder coated finish fronback opening type, with aprons for cable entry from bottom and fixing 02 Nos danger notice plate with letter , figures and conventional skul bones in signal red colour and fixed front & back door LT panel etc with voltage and danger indicated in Hindi and English with double door shutter and lockingarangement , internal wiring with PVC insulated, stranded copper conductor, FRLS cable, IS-694 marked of adequate size but not less than 2.5 Sqmm. The platform shall be such that of size 16 to 400 Sqmm and compising of the following: (for transformer No-02 (315 KVA)(a) Bus bar chamber of 3 phase and neutral 4 strip 415 volts with 1200 Amps Aluminium - 1 set (a) 3 Phase 4 wire 50 Hz ACB 4 Pole 415 V 800 Amps, 50 kA -1 Nos. (Incoming) (b) Ammeter 0- 1000 Amps 96 mm x 96mm electro mechancial type with three way ON/OFF rotary type selector switch and 3 current transformer of suitable ratio and capacity Qty 1 No (c) Indicating lamps for three phases Qty 1 set of 3 Nos |
| 61 | (d) Voltmeter 0 - 500 Volts 96 mm x 96mm electro mechanical type with 3 way ON/OFF rotary type selector switch - Qty 01 No make AE/Rishab /Meco/Enercon). Outgoing:- (a) 4 pole MCCB 63 Amp, 50 HZ 415 V, 25 kA-1 no. (b) 4 pole MCCB 160 Amp 50 Hz 415 V, 35 ka - 01 no(e). 4 pole MCCB 125 Amp 50 Hz 415 V, 35 ka - 01 no.(d). 4 pole MCCB 100 Amp 50 Hz 415 V, 35 kA - 01 no. (f) 4 pole MCCB 40 Amp, 50 HZ 415 V, 25 ka-2 nos. (g) TPN 40 Amp , 50 HZ 415 V , 25 kA-01 No (h). On load Change over Switch of capacity 400Amp - 1 No. (j) 3 Phase 4 Wire 50 Hz 400 Amp MCCB, 35 kA -01 (For Ring Main) , including cost of material, labour and T & P as per drawing complete, for proper completion of work and as per direction of Engineer in Charge. (k) Platform of panel :- platform for the panel with PCC 1:4:8 type D2 with 40mm graded crushed stone , 15cm thick in foundation, brick work in CM 1:6 with sub class 'B' old size bricks, rendering 15cm thicj in in CM 1:6 on exposed surfaces and 100mm thick PCC padding 1:3:6 type -1 using 20mm graded crushed stone aggregate on toop and grouting bolts etc for panel The The various feeders shall be indicated by 50mm size letters in synthetic enamel white paint.The platform shall be such that it is of a height 45 cm above the nearest road level.Notes : (i) All termination of existing cable should be provided with copper lugs/thimbles and suitable size of glands & rate for the same is deemed to be included in the item. (iii) Provision of one spare MCCB and one spare MCB chamber in panel to be made for future extension. (iii) The various feeders shall be indicated by 50mm size letters in synthetic enamel white paint. |
| 62 | Supply installng testing and commissioning of factory made and tested CPRI approved LT panel board, outdoor type, canopy headed, platform mounted suitable for 415 Volts 3 phase 4 wire, 50 HZ AC supply , having bus bar chamber wih insulated aluminium bus bars of cap 250 Amp insulated on porcelain insulators. The panel shall be dust and vermin proof, IP 65 class protection and made of 3.15mm CRCA MS Sheet and 50 x 50x 6mm thick angle iron frame work, powder coated finish fronback opening type, with aprons for cable entry from bottom and fixing 02 Nos danger notice plate with letter , figures and conventional skul bones in signal red colour and fixed front & back door LT panel etc with voltage and danger indicated in Hindi and English with double door shutter and lockingarangement , internal wiring with PVC insulated, stranded copper conductor, FRLS cable, IS-694 marked of adequate size but not less than 2.5 Sqmm. The platform shall be such that of size 16 to 400 Sqmm and compising of the following: (Location K ) (a)MCCB 4 pole 415 V 160 Amps, 35 ka -2 Nos (1 Spare) (Incoming) (b)Ammeter 0- 500 Amps 96 mm x 96mm electro mechancial type with three way ON/OFF rotary type selector switch and 3 current transformer of suitable ratio and capacity Qty 1 No (c) Indicating lamps for three phases Qty 1 set of 3 Nos (d) Voltmeter 0 - 500 Volts 96 mm x 96mm electro mechanical type with 3 way ON/OFF rotary type selector switch - Qty 01 No make AE/Rishab /Meco/Enercon). |
| 63 | Outgoing:- a) 4 Pole MCCB 63 Amp , 50 HZ 415 V, 25 kA -03 Nos,(e) Platform of panel :- platform for the panel with PCC 1:4:8 type D2 with 40mm graded crushed stone , 15cm thick in foundation, brick work in CM 1:6 with sub class 'B' old size bricks, rendering 15cm thick in in CM 1:6 on exposed surfaces and 100mm thick PCC padding 1:3:6 type -1 using 20mm graded crushed stone aggregate on toop and grouting bolts etc for panel The The various feeders shall be indicated by 50mm size letters in synthetic enamel white paint.The platform shall be such that it is of a height 45 cm above the nearest road level.Notes :- (i) All termination of existing cable should be provided with copper lugs/thimbles and suitable size of glands & rate for the same is deemed to be included in the item (ii) Provision of one spare MCCB and one spare MCB chamber in panel to be made for future extension. (iii) The various feeders shall be indicated by 50mm size letters in synthetic enamel white paint. |
| 64 | Supply installng testing and commissioning of factory made and tested CPRI approved LT panel board, outdoor type, canopy headed, platform mounted suitable for 415 Volts 3 phase 4 wire, 50 HZ AC supply , having bus bar chamber wih insulated aluminium bus bars of cap 200 Amp insulated on porcelain insulators. The panel shall be dust and vermin proof, IP 65 class protection and made of 3.15mm CRCA MS Sheet and 50 x 50x 6mm thick angle iron frame work, powder coated finish fronback opening type, with aprons for cable entry from bottom and fixing 02 Nos danger notice plate with letter , figures and conventional skul bones in signal red colour and fixed front & back door LT panel etc with voltage and danger indicated in Hindi and English with double door shutter and lockingarangement , internal wiring with PVC insulated, stranded copper conductor, FRLS cable, IS-694 marked of adequate size but not less than 2.5 Sqmm. The platform shall be such that of size 16 to 400 Sqmm and compising of the following: (Location L ) (a)MCCB 4 pole 415 V 125 Amps, 35 ka -2 Nos (1 Spare) (Incoming) (b)Ammeter 0- 500 Amps 96 mm x 96mm electro mechancial type with three way ON/OFF rotary type selector switch and 3 current transformer of suitable ratio and capacity Qty 1 No (c) Indicating lamps for three phases Qty 1 set of 3 Nos (d) Voltmeter 0 - 500 Volts 96 mm x 96mm electro mechanical type with 3 way ON/OFF rotary type selector switch - Qty 01 No make AE/Rishab /Meco/Enercon). |
| 65 | Outgoing:- (a) 4 Pole MCCB 63 Amp , 50 HZ 415 V, 25 kA -02 Nos,(b) Platform of panel :- platform for the panel with PCC 1:4:8 type D2 with 40mm graded crushed stone , 15cm thick in foundation, brick work in CM 1:6 with sub class 'B' old size bricks, rendering 15cm thicj in in CM 1:6 on exposed surfaces and 100mm thick PCC padding 1:3:6 type -1 using 20mm graded crushed stone aggregate on toop and grouting bolts etc for panel The The various feeders shall be indicated by 50mm size letters in synthetic enamel white paint.The platform shall be such that it is of a height 45 cm above the nearest road level.Notes :- (i) All termination of existing cable should be provided with copper lugs/thimbles and suitable size of glands & rate for the same is deemed to be included in the item (iii) Provision of one spare MCCB and one spare MCB chamber in panel to be made for future extension. (iii) The various feeders shall be indicated by 50mm size letters in synthetic enamel white paint. |
| 66 | Supply installng testing and commissioning of factory made and tested CPRI approved LT panel board, outdoor type, canopy headed, platform mounted suitable for 415 Volts 3 phase 4 wire, 50 HZ AC supply , having bus bar chamber wih insulated aluminium bus bars of cap 160 Amp insulated on porcelain insulators. The panel shall be dust and vermin proof, IP 65 class protection and made of 3.15mm CRCA MS Sheet and 50 x 50x 6mm thick angle iron frame work, powder coated finish fronback opening type, with aprons for cable entry from bottom and fixing 02 Nos danger notice plate with letter , figures and conventional skul bones in signal red colour and fixed front & back door LT panel etc with voltage and danger indicated in Hindi and English with double door shutter and lockingarangement , internal wiring with PVC insulated, stranded copper conductor, FRLS cable, IS-694 marked of adequate size but not less than 2.5 Sqmm. The platform shall be such that of size 16 to 400 Sqmm and compising of the following: (Location P ) (a)MCCB 4 pole 415 V 100 Amps, 25 ka -2 Nos (1 Spare) (Incoming) (b)Ammeter 0- 500 Amps 96 mm x 96mm electro mechancial type with three way ON/OFF rotary type selector switch and 3 current transformer of suitable ratio and capacity Qty 1 No (c) Indicating lamps for three phases Qty 1 set of 3 Nos (d) Voltmeter 0 - 500 Volts 96 mm x 96mm electro mechanical type with 3 way ON/OFF rotary type selector switch - Qty 01 No make AE/Rishab /Meco/Enercon). |
| 67 | Outgoing:- a) 4 Pole MCCB 63 Amp, 50 HZ 415 V, 25 kA -02 Nos,(e) Platform of panel :- platform for the panel with PCC 1:4:8 type D2 with 40mm graded crushed stone , 15cm thick in foundation, brick work in CM 1:6 with sub class 'B' old size bricks, rendering 15cm thick in in CM 1:6 on exposed surfaces and 100mm thick PCC padding 1:3:6 type -1 using 20mm graded crushed stone aggregate on toop and grouting bolts etc for panel The The various feeders shall be indicated by 50mm size letters in synthetic enamel white paint.The platform shall be such that it is of a height 45 cm above the nearest road level.Notes :- (i) All termination of existing cable should be provided with aluminium/thimbles and suitable size of glands & rate for the same is deemed to be included in the item (ii) Provision of one spare MCCB and one spare MCB chamber in panel to be made for future extension. (iii) The various feeders shall be indicated by 50mm size letters in synthetic enamel white paint. |
| 68 | Supply installng testing and commissioning of factory made and tested CPRI approved LT panel board, indoor type, platform mounted suitable for 415 Volts 3 phase 4 wire, 50 HZ AC supply , having bus bar chamber wih insulated aluminium bus barsof 100 Amp insulated on porcelain insulators. The panel shall be dust and vermin proof, IP 54 class protection and made of 2mm CRCA MS Sheet and 50 x 50x 6mm thick angle iron frame work, powder coated finish fronback opening type, with aprons for cable entry from bottom and fixing 02 Nos danger notice plate with letter , figures and conventional skul bones in signal red colour and fixed front & back door LT panel etc with voltage and danger indicated in Hindi and English with double door shutter and lockingarangement , internal wiring with PVC insulated, stranded copper conductor, FRLS cable, IS-694 marked of adequate size but not less than 2.5 Sqmm. The platform shall be such that of size 16 to 400 Sqmm and compising of the following: (LT panel No- 08 , Raw water Pump house)(a) Bus bar chamber of 3 phase and neutral 4 strip 415 volts with 100 Amps Aluminium - 1 set (a) 3 Phase 4 wire 50 Hz MCCB 4 Pole 415 V 63 Amps, 36 kA -2 Nos. (Incoming) (b) Ammeter 0- 1000 Amps 96 mm x 96mm electro mechancial type with three way ON/OFF rotary type selector switch and 3 current transformer of suitable ratio and capacity Qty 1 No (c) Indicating lamps for three phases Qty 1 set of 3 Nos (d) Voltmeter 0 - 500 Volts 96 mm x 96mm electro mechanical type with 3 way ON/OFF rotary type selector switch - Qty 01 No make AE/Rishab /Meco/Enercon). |
| 69 | Outgoing:- (a) 4 Pole MCCB 63 Amp , 50 HZ 415, 25 kA -03 Nos (b) TPN MCB 40A, 25 kA - 1 no. (c). Star Delta starter for 10 HP Motor - 2 nos. (d). Fully automatic Star Delta starter 30 HP for 20 HP Motor - 1 nos (e) Platform of panel :- platform for the panel with PCC 1:4:8 type D2 with 40mm graded crushed stone , 15cm thick in foundation, brick work in CM 1:6 with sub class 'B' old size bricks, rendering 15cm thick in in CM 1:6 on exposed surfaces and 100mm thick PCC padding 1:3:6 type -1 using 20mm graded crushed stone aggregate on toop and grouting bolts etc for panel The The various feeders shall be indicated by 50mm size letters in synthetic enamel white paint.The platform shall be such that it is of a height 45 cm above the nearest road level.Notes : (i) All termination of existing cable should be provided with aluminium/thimbles and suitable size of glands & rate for the same shall deemed to be included in the item (ii) Provision of one spare MCCB and one spare MCB chamber in panel to be made for future extension. (iii) The various feeders shall be indicated by 50mm size letters in synthetic enamel white paint. |
| 70 | Supply installng testing and commissioning of factory made and tested CPRI approved LT panel board, indoor type, platform mounted suitable for 415 Volts 3 phase 4 wire, 50 HZ AC supply , having bus bar chamber wih insulated aluminium bus barsof 100 Amp insulated on porcelain insulators. The panel shall be dust and vermin proof, IP 54 class protection and made of 2mm CRCA MS Sheet and 50 x 50x 6mm thick angle iron frame work, powder coated finish fronback opening type, with aprons for cable entry from bottom and fixing 02 Nos danger notice plate with letter , figures and conventional skul bones in signal red colour and fixed front & back door LT panel etc with voltage and danger indicated in Hindi and English with double door shutter and lockingarangement , internal wiring with PVC insulated, stranded copper conductor, FRLS cable, IS-694 marked of adequate size but not less than 2.5 Sqmm. The platform shall be such that of size 16 to 400 Sqmm and compising of the following: (LT panel No- 09 , Clean water Pump house)(a) Bus bar chamber of 3 phase and neutral 4 strip 415 volts with 100 Amps Aluminium - 1 set (a) 3 Phase 4 wire 50 Hz MCCB 4 Pole 415 V 63 Amps, 25 kA -2 Nos. (Incoming) (b) Ammeter 0- 1000 Amps 96 mm x 96mm electro mechancial type with three way ON/OFF rotary type selector switch and 3 current transformer of suitable ratio and capacity Qty 1 No (c) Indicating lamps for three phases Qty 1 set of 3 Nos (d) Voltmeter 0 - 500 Volts 96 mm x 96mm electro mechanical type with 3 way ON/OFF rotary type selector switch - Qty 01 No make AE/Rishab /Meco/Enercon). |
| 71 | Outgoing:- (a) 4 Pole MCCB 63 Amp , 50 HZ 415V, 25 kA -02 Nos (b) TPN MCB 40A, 25 kA - 1 no. (c). Star Delta starter for 10 HP Motor - 2 nos, (d) Platform of panel :- platform for the panel with PCC 1:4:8 type D2 with 40mm graded crushed stone , 15cm thick in foundation, brick work in CM 1:6 with sub class 'B' old size bricks, rendering 15cm thick in in CM 1:6 on exposed surfaces and 100mm thick PCC padding 1:3:6 type -1 using 20mm graded crushed stone aggregate on toop and grouting bolts etc for panel The The various feeders shall be indicated by 50mm size letters in synthetic enamel white paint.The platform shall be such that it is of a height 45 cm above the nearest road level.Notes :- (i) All termination of existing cable should be provided with aluminium/thimbles and suitable size of glands & rate for the same is deemed to be included in the item (ii) Provision of one spare MCCB and one spare MCB chamber in panel to be made for future extension. (iii) The various feeders shall be indicated by 50mm size letters in synthetic enamel white paint. |
| 72 | Supply installng testing and commissioning of factory made and tested CPRI approved LT panel board, outdoor type, canopy headed, platform mounted suitable for 415 Volts 3 phase 4 wire, 50 HZ AC supply , having bus bar chamber wih insulated aluminium bus bars of cap 63 Amp insulated on porcelain insulators. The panel shall be dust and vermin proof, IP 65 class protection and made of 3.15mm CRCA MS Sheet and 50 x 50x 6mm thick angle iron frame work, powder coated finish fronback opening type, with aprons for cable entry from bottom and fixing 02 Nos danger notice plate with letter , figures and conventional skul bones in signal red colour and fixed front & back door LT panel etc with voltage and danger indicated in Hindi and English with double door shutter and lockingarangement , internal wiring with PVC insulated, stranded copper conductor, FRLS cable, IS-694 marked of adequate size but not less than 2.5 Sqmm. The platform shall be such that of size 16 to 400 Sqmm and compising of the following: (Panel 10 for street light ) (a)MCCB 4 pole 415 V 32 Amps, 25 ka - Nos (Incoming) (b)Ammeter 0- 500 Amps 96 mm x 96mm electro mechancial type with three way ON/OFF rotary type selector switch and 3 current transformer of suitable ratio and capacity Qty 1 No (c) Indicating lamps for three phases Qty 1 set of 3 Nos (d) Voltmeter 0 - 500 Volts 96 mm x 96mm electro mechanical type with 3 way ON/OFF rotary type selector switch - Qty 01 No make AE/Rishab /Meco/Enercon). |
| 73 | Outgoing:- (a) 4 Pole MCCB 32 Amp , 50 HZ 415 V, 25 kA -03 No (b). Timer switch, Controlled relay, Contactors etc,(c) Platform of panel :- platform for the panel with PCC 1:4:8 type D2 with 40mm graded crushed stone , 15cm thick in foundation, brick work in CM 1:6 with sub class 'B' old size bricks, rendering 15cm thick in in CM 1:6 on exposed surfaces and 100mm thick PCC padding 1:3:6 type -1 using 20mm graded crushed stone aggregate on toop and grouting bolts etc for panel The The various feeders shall be indicated by 50mm size letters in synthetic enamel white paint.The platform shall be such that it is of a height 45 cm above the nearest road level.Notes :- (i) All termination of existing cable should be provided with aluminium/thimbles and suitable size of glands & rate for the same is deemed to be included in the item (ii) Provision of one spare MCCB and one spare MCB chamber in panel to be made for future extension. (iii) The various feeders shall be indicated by 50mm size letters in synthetic enamel white paint. |
| 74 | Supply installng testing and commissioning of factory made and tested CPRI approved LT panel board, outdoor type, canopy headed, platform mounted suitable for 415 Volts 3 phase 4 wire, 50 HZ AC supply , having bus bar chamber wih insulated aluminium bus bars of cap 160 Amp insulated on porcelain insulators. The panel shall be dust and vermin proof, IP 65 class protection and made of 3.15mm CRCA MS Sheet and 50 x 50x 6mm thick angle iron frame work, powder coated finish fronback opening type, with aprons for cable entry from bottom and fixing 02 Nos danger notice plate with letter , figures and conventional skul bones in signal red colour and fixed front & back door LT panel etc with voltage and danger indicated in Hindi and English with double door shutter and lockingarangement , internal wiring with PVC insulated, stranded copper conductor, FRLS cable, IS-694 marked of adequate size but not less than 2.5 Sqmm. The platform shall be such that of size 16 to 400 Sqmm and compising of the following: (Panel B) (a)MCCB 4 pole 415 V 100 Amps, 25 kA -2 Nos (01 spares) (Incoming) (b)Ammeter 0- 500 Amps 96 mm x 96mm electro mechancial type with three way ON/OFF rotary type selector switch and 3 current transformer of suitable ratio and capacity Qty 1 No (c) Indicating lamps for three phases Qty 1 set of 3 Nos (d) Voltmeter 0 - 500 Volts 96 mm x 96mm electro mechanical type with 3 way ON/OFF rotary type selector switch - Qty 01 No make AE/Rishab /Meco/Enercon). |
| 75 | Outgoing- (a) 4 pole MCCB upto 40 Amp 50 HZ 415 V, 25 kA-3 nos.,(b) Platform of panel :- platform for the panel with PCC 1:4:8 type D2 with 40mm graded crushed stone , 15cm thick in foundation, brick work in CM 1:6 with sub class 'B' old size bricks, rendering 15cm thick in in CM 1:6 on exposed surfaces and 100mm thick PCC padding 1:3:6 type -1 (using 20mm graded stone aggregate) on toop and grouting bolts etc for panel The The various feeders shall be indicated by 50mm size letters in synthetic enamel white paint.The platform shall be such that it is of a height 45 cm above the nearest road level.Notes :- (i) All termination of existing cable should be provided with aluminium/thimbles and suitable size of glands & rate for the same is deemed to be included in the item (iii) Provision of one spare MCCB and one spare MCB chamber in panel to be made for future extension. (iii) The various feeders shall be indicated by 50mm size letters in synthetic enamel white paint. |
| 76 | Supply installng testing and commissioning of factory made and tested CPRI approved LT panel board, outdoor type, canopy headed, platform mounted suitable for 415 Volts 3 phase 4 wire, 50 HZ AC supply , having bus bar chamber wih insulated aluminium bus bars of cap 160 Amp insulated on porcelain insulators. The panel shall be dust and vermin proof, IP 65 class protection and made of 3.15mm CRCA MS Sheet and 50 x 50x 6mm thick angle iron frame work, powder coated finish fronback opening type, with aprons for cable entry from bottom and fixing 02 Nos danger notice plate with letter , figures and conventional skul bones in signal red colour and fixed front & back door LT panel etc with voltage and danger indicated in Hindi and English with double door shutter and lockingarangement , internal wiring with PVC insulated, stranded copper conductor, FRLS cable, IS-694 marked of adequate size but not less than 2.5 Sqmm. The platform shall be such that of size 16 to 400 Sqmm and compising of the following: (Panel S ) (a)MCCB 4 pole 415 V 63 Amps, 25 ka - 2 Nos (01 Spare (Incoming) (b)Ammeter 0- 500 Amps 96 mm x 96mm electro mechancial type with three way ON/OFF rotary type selector switch and 3 current transformer of suitable ratio and capacity Qty 1 No (c) Indicating lamps for three phases Qty 1 set of 3 Nos (d) Voltmeter 0 - 500 Volts 96 mm x 96mm electro mechanical type with 3 way ON/OFF rotary type selector switch - Qty 01 No make AE/Rishab /Meco/Enercon). |
| 77 | Outgoing- (a) 4 pole MCCB upto 63 Amp 50 HZ 415 V, 25 kA-1 nos.,(b) TPN MCB 40 Amp-01 No(e) Platform of panel :- platform for the panel with PCC 1:4:8 type D2 with 40mm graded crushed stone , 15cm thick in foundation, brick work in CM 1:6 with sub class 'B' old size bricks, rendering 15cm thick in in CM 1:6 on exposed surfaces and 100mm thick PCC padding 1:3:6 type -1 (using 20mm graded stone aggregate) on top and grouting bolts etc for panel The The various feeders shall be indicated by 50mm size letters in synthetic enamel white paint.The platform shall be such that it is of a height 45 cm above the nearest road level.Notes :- (i) All termination of existing cable should be provided with aluminium/thimbles and suitable size of glands & rate for the same is deemed to be included in the item (iii) Provision of one spare MCCB and one spare MCB chamber in panel to be made for future extension. (iii) The various feeders shall be indicated by 50mm size letters in synthetic enamel white paint. |
| 78 | Supply and fixing of metal juction box of suitable size with aluminium bus bar rated for 415 V ,50 Hz, AC supply with 10 Amp, SP MCB for controlling of street light, for proper completion of work complete all as specified and directed. |
| 79 | Supply and fixing cable route indicator made out PCC pole (0.3m X 0.3m X 1.0m ) (LXWXH) on H T / LT cable upto 1mtr depth grouted in the ground with sutaible PCC work with writing LT/HT cable / Joint with pole number complete all as specified and directed. |
| 80 | EXTERNAL WATER SUPPLY |
| 81 | Materials and Labour for centrifugally cast (spun) ductile iron pressure pipes for water mains, with spigot and socketed ends, Class K9, ISI Marked [IS 8329:2000 (Re affirmed 2005)], in any length, jointed by push-on flexible joints with rubber gaskets conforming to IS 5382, laid in trenches, complete all as specified and directed. of following size:- ( For rising main ) |
| 82 | (a) 200 mm dia. |
| 83 | (b) 150 mm dia. |
| 84 | (c) 100 mm dia. |
| 85 | M & L for construction of valve chamber for gate / sluice valve of following size all as specified including necessary excavation and earthwork, MS sheet cover and angle iron frame, painting with two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer including necessary locking arrangement of following sizes complete all as specified and directed. |
| 86 | (a) 1.2M x 1.2M x 1.2 M |
| 87 | b) 0.9M x 0..9M x 0.9 M |
| 88 | (c) 0.75M x 0.75M x 0.75M |
| 89 | Materials and Labour for,100 mm bore, centrifugally cast (spun) ductile iron pressure pipes for water mains, with spigot and socketed ends, Class K7, ISI Marked [IS 8329:2000 (Reaffirmed 2005)], in any length, jointed by push-on flexible joints with rubber gaskets conforming to IS 5382, laid in trenches, complete all as specified and directed. |
| 90 | Supply and laying ductile iron fittings for spigot and socketed pipes such as bends (any type, radius and angle) tapers any type, (straight, bend, increasing, decreasing or double socket etc.) Tee pieces single branch. \\"Y\\" junction, double branch, cross (all sockets or socket and spigot) collars, caps and plugs, ISI Marked [IS 9523 :2000 (Re-affirmed 2005)], suitable for bore of pipe up to 450 mm, complete all as specified and directed. |
| 91 | S & F Valve reflux with by pass arrangements supplied and installed complete of size 100 mm dia, complete all as specified and directed. |
| 92 | M & L for Drilling trial Bore of suitable diameter with reverse rotary circulation or direct circulation method or combination of both by using power rig for housing B345:D348of 250 mm nominal bore reduced to 150 mm below ground level in any kind of soil strata including hard stone/ boulder etc. complete all as specified and directed. (100 Mtr x 02 borewell as different location) complete all as specified and directed. NOTE:- The anticipated depth of boring of the tube well at site is 100 metres below ground level. However, the depth of boring may be varied maximum upto 40 Metres (Plus or Minus) as ordered by PM in writing. |
| 93 | M & L for Development of trial bore by reaming in steps viz From 250 mm to 350 mm ; From 350 mm to 450 mm ; From 450 mm to 525 mm; From 525 mm to 675 mm, up to 60 RM from ground level for insertion of casing pipe 350 mm bore for 02 Nos borewell complete all as specified and directed. |
| 94 | Development of trial bore by reaming in steps viz From 250 mm to 350 mm ; From 350 mm to 450 mm ; From 450 mm to 525 mm, exceeding 60 Rm but not exceeding 100 RM from ground level for insertion of casing pipe/stainer, 250 mm bore, complete all as specified and directed.NOTES: - (a) Depending upon the availability of water bearing strata, if drilling beyond 100.00 Metre is required, the same shall be carried out only after obtaining written approval from PM. |
| 95 | Supply, lowering and fixing in position 250 mm nominal bore ERW heavy duty MS casing pipe of 7.10 mm wall thickness and welding joints with MS coupler ring around the pipes with MS flat iron 80 mm X 6 mm complete all as specified and directed. |
| 96 | Supply, lowering and fixing in position 350mm nominal bore ERW heavy duty MS casing pipe of 7.10 mm wall thickness and welding joints with MS coupler ring around the pipes with MS flat iron 80 mm X 6 mm complete all as specified and directed. |
| 97 | Supply lowering and fixing in position 250 mm bore, 8.00 mm wall thickness, low carbon galvanized steel (LCG) strainer, 'V' wired type (inwardly widening to give no clogging property and shall have minimum geometrical resistance to water flow to reduce frictional head losses) , with 1 mm continuous slot to offer not less than 25 % open area, and with bevelled end, conforming to IS 8110:2000 (Reaffirmed 2006), butt jointed by welding in suitable length with MS flat iron 80 X 6 mm coupler ring all around the pipe complete all as specified and directed. |
| 98 | Supply lowering and fixing in position MS reducing socket 350 mm X 250 mm nominal bore, 8 mm thick and duly welded to pipe with MS flat iron 80 mm X 6 mm coupler ring complete all as specified and directed. |
| 99 | S & F development of tube well with compressed air and after with 25% extra capacity pump by pumping muddy water, including cost of material, labour and T & P as per drawing complete,all as specified and directed. |
| 100 | Supply and Fix, Bail Plug having 3.00 Metre length, fabricated out of ERW heavy duty MS casing pipe of 7.10 mm wall thickness and suitable for 250 mm bore, including welding joints with MS coupler ring around the pipes with MS flat iron 80 mm X 6 mm, complete all as specified and directed. |
| 101 | Supplying, pouring and packing pea-gravel of size 3 mm to 8 mm and packed all around the entire bore well to fill in the annular space between pipe assembly and bore hole, complete all as specified and directed. |
| 102 | Providing water logging test with electro logging equipment and required machinery for ascertaining / logging aquifers encountered in trial bore and arranging and defining the water availability test giving test report of Geo-Hydrologist from Govt. approved laboratory recommending water bearing zones, TDS of water etc., complete all as specified and directed. |
| 103 | M & L for yield test for bore well by continuous pumping for 15 hrs to determine safe pumping yield complete all as specified and directed. |
| 104 | Supply, fixing and lowering 100 mm bore MS, column pipe, both end flanged, 3.00 Metre long, fitted with flanges at both ends made out of heavy grade pipes of 5.4 mm wall thickness, ISI Marked (IS: 1239-Part-I), complete with bolts, nuts, gaskets etc. as required complete all as specified and directed. |
| 105 | Supply and fixing well cap made out of 5 mm thick MS plate with provision of suitable holes for passing through two runs of flat three core, PVC insulated industrial cable for submersible motor, 16.00 Sq. mm and suitable for fixing to 350 mm nominal bore ERW heavy duty MS casing pipe of 8.00 mm wall thickness complete all as specified and directed. |
| 106 | Supply, installation, testing and commissioning of submersible pump set , electric driven 415 V, 50 Hz, Three Phase, 20 HP, 15 KW, speed 2900 RPM (Sync) , delivery size suitable for 150mm size NRV, having discharge capacity 670 Litres per minute at 75 Metre head, suitable for lowering inside existing casing pipe of bore well (300/350mm) including necessary jointing to existing GI column pipes with flanged joints, with rubber gaskets, nut, bolts & washers of required size, and including electrical connection from starter panel to motor with existing submersible cable, complete all as specified and directed.[Model No :- ‘UPHA 293/4 + HBC 203’ of Make ‘KSB’ or equivalent model of Make ‘Crompton Greaves' / 'Calama']. NOTE:- Column pipe with flanged joints and submersible cable will be measured and paid seperately. |
| 107 | Materials and Labour for, flat three core, PVC insulated industrial cable for submersible motor, 10.00 Sq. mm (Nominal area) with multi stranded copper conductor, 1100 Volts grade, conforming to IS: 694 all as per product Code No WHPNDSKB3010 of Make ‘Havells’ or equivalent make of Finolex / RR Cable, connected from starter to submersible pump motor, complete all as specified and directed. |
| 108 | Supply, Installation, testing and commissioning of Chlorine Solution Dosing System (Make of approved list of department and approved by PM) comprising of dosing pump (suitable for chlorine solution prepared from calcium based granules), AC, single phase, 230 Volts, 50 Hz, electrically operated with high starting torque, having positive displacement diaphragm type accurated by a solenoid solid state pulsar, with discharge capacity of 1 to 8 Litres / Hour of standard mixture of calcium based calcium base chlorine granule with water, of any strength and suitable for injecting chemical mixture at 4 to 6 Kg per sq cm pressure, with provision of polypropylene / LDPE suction and discharge pipes of suitable size and length with swing seal foot valve at bottom end of suction pipe, and with 100 Litres capacity FRP tank with FRP Lid having post hole for pouring calcium based chlorine granules and water, including provision for mounting the dosing pump on the lid/wall of FRP tank , provision of Level Gauge, Agitator (1280 to 1400 RPM) with shaft and blade in SS 316 (FRP Coated/Epoxy Coated /Plastic Coated) mounted on tank complete with all accessories required for installation as per Manufacturers instructions including supply of 02 (Two) Years normal maintenance Spares i.e. (i) PVC Pump roller tube – 02 (Two) Nos. (ii) Mixing Blade complete with PVC shaft and pin as per Manufacturers instructions – 02 (Two) Sets. and including making provision of mounting the pump set and provision of PCC foundation for placing the FRP tank, complete all as specified and directed. |
| 109 | Supply, Installation, testing and commissioning of integrated water treatment plant including all mechanical works, electrical control panel, piping works, interconnection works, civil works in foundations and required components with accessories as per details here in after complete all as specifies and directed.(a) DUAL MEDIA FILTER PLANT. 50 cum/hr capacity for removal of suspended solids, dirt, reduce silt density index, reduce turbidity limit and lower down the parameters upto permissible limits as per IS: 10500, complete with MS epoxy coated vessel as per IS 2825 [Thickness not less than 8mm], with suitable filter media (i) anthracite, iii (quartz sand iv) coarse sand etc. and with suitable common raw water feed pumps, common air compressor, common back washing pumping facility, mechanical, electrical control panel, piping works, pressure guage 10 kg/cm2. Material quality IS: 2062 design IS: 2825 for shell.(b) IRON REMOVAL FILTER PLANT. 50 cum/hr capacity for removal of iron from the raw water and lower down upto permissible limit, complete with MS epoxy coated vessel as per IS 2825 (Thickness not less than 8 mm), with suitable filter media i)sand, ii) gravel, iii) MnO2, iv) Berm etc. and with suitable common air compressor, common back washing pumping facility, mechanical, electrical control panel, piping work, pressure guage 10 kg/cm2. Material quality IS: 2062 design for shell.(c) ACTIVATED CARBON FILTER PLANT. 80 cum/hr capacity for removal of color, smell/odour, free residual chlorine and oil from the raw water and lower down upto permissible limit as per IS:10500, complete with MS epoxy coated vessel as per IS:2825 (Thickness not less than 8 mm), suitable media [(i) Activated carbon with high degree of microporosity etc.] and with suitable common air compressor, common back washing pumping facility, mechanical, electrical control panel, piping works, pressure guage 10 kg/cm2. Material quality IS:2825 for shell.(d) 02 (two) Nos [01 working + 01 Standby] best efficient, suitable common raw water feed pumps. (e) Commom air compressor (f) Common back washing pumping facility.(g) All mechanical, electrical, control panel, piping, civil works, pressure gauges, cocks, air vent systems, back washing arrangements with suitable size CI sluice / butterfly valves. |
| 110 | Supply, install, testing & commissioning of Centrifugal Monoblock Pump set of cast Iron impeller with gland packing coupled with induction moter with ‘F’ Classs insulation and IP 55 protection suitable for 3 phase, 300 to 415 Volts, 2900 RPM, discharge not less than 10 lps at minimum 36 meter head with power rating 7.5 KW and 10 HP, impeller, delivery casing and moter body made of cost iron, pump shaft made of carbon steel, sealing with gland packed. Suitable for suction from pipe of size 50 mm dia and delivery to pipe of size 40 mm dia including of Star delta starter of brand Schneider with single phase preventer and over load protection , with provision of 3 crore 10 Sqmm Flat copper cable from starter pannel to pump set, priming line watering arrangement complete using 20mm dia GL pipe Med grade of length upto 10 RM, gate valve 20mm dia- 10 No with necessary PCC foundation with suitable size of nuts, bolts grouted & washers and complete all as specified and as directed and The rates are inclusive of testing of pump set installation for satisfactory functioning / running & minimum 2 years warranty complete all as specified and directed. Make:-Kirloskar/Crompton/GE |
| 111 | Supply and fix fully automatic star delta strarter in sheet steel enclosure, suitable for 20HP motor (30 HP starter)3 phase , 415 V, 50 Hz relay range 13-21 A, coil voltage 360V as as per specified and directed. MAKE:- L & T or equivallent in BCH / Seimens / Abb |
| 112 | Supply, installation, commissioning and testing silent diesel engine driven Generating Set 50 KVA (40 KW at 0.8 PF) capacity 415 Volts, 3 phase, 4 wire & with including acoustic weather proof enclosure as per CPCB norms and noise level shall not be exceeding 75 db at a distance of 1 metre from all sides, complete in all respects & comprising the following components. MAKE :- Kirloskar Green / Kirloskar Cummins |
| 113 | (A) Diesel Engine developing suitable BHP at 1500 RPM conforming to BS 5514/ISO0346 series capable of taking 10% overloading for 01 hour after 12 hours of continuous operation inclusive of the following accessories:- |
| 114 | (i) Radiator and Radiator fan |
| 115 | (ii) Spider coupling guard |
| 116 | (iii) Fly wheel |
| 117 | (iv) Fly wheel housing complete with starter gear ring and coupling as per manufacturer design. |
| 118 | (v) Air cleaner dry type. |
| 119 | (vi) Fuel and lubricant oil filter. |
| 120 | (vii) By-pass filter |
| 121 | (viii) Coolant inhibitor |
| 122 | (ix) Fuel pump DTR type/in line mono block fuel injecting pump. |
| 123 | (x) Water pump |
| 124 | (xi) Lub oil pump and inclusive of first filling of lubricant oil & coolant. |
| 125 | (xii) Electric starter 12 Volts DC as manufacturer's design. |
| 126 | (xiii) Battery charging generator (DC alternator) |
| 127 | (xiv) Industrial silencer |
| 128 | (xv) Lubricant oil cooler |
| 129 | (xvi) Flexible pipe for silencer |
| 130 | (xvii) DC volt meter |
| 131 | (xviii) Water temperatures gauge, lub oil pressure gauge |
| 132 | (xix) Speedo meter and Engine running hours meter |
| 133 | xx) Display for fault |
| 134 | (xxi) Suitable size of turbo-charger |
| 135 | (xxii) Shut off coil with safeties for LLOP/HWT. |
| 136 | (xxiii) Mechanical Governor. |
| 137 | (xxiv) Maintenance free secondary batteries 12 Volts as per manufacture design. |
| 138 | (xxv) Safeties and indications against Low Lube Oil Pressure & High Coolant Temperature. |
| 139 | (xxvi) In-line monoblock Fuel Injection Pump with Mechanical Governor and fuel feed pump. |
| 140 | (xxviii) Engine mounting supports. |
| 141 | (xxix)Engine control panel consisting of OFF/ON/START keys, Lube Oil Pressure Gauge, |
| 142 | (xxx)Ammeter, Electric Hour meter. |
| 143 | (xxxi)Engine Operator/Maintenance & Spare parts Manual. |
| 144 | (xxxii)Engine Spare parts Manual. |
| 145 | (xxxiii)Engine Warranty Certificate. |
| 146 | (xxxiv)Engine test certificate. |
| 147 | (xxxv) Asbestos Rope |
| 148 | (B) Alternator:- Synchronous alternator 50 KVA,1500rpm, 415 Volts,50Hz, 3 phase system, brushless type,screen protected revolving filled self excited, self regulated, confirming to IS 4772 of 1992/BS 500. |
| 149 | (c) AMF panel : AMF Panel shall be of suitable size, factory made, indoor cubical type, front openable, fabricated from CRCA steel sheet 2 mm thick complete as per manufacturer specification of Diesel Engine suitablefor DG set of capacity 50 KVA, grouted in floor with PCC 1 :2:4 type B-2 foundation of suitable size as per manufacturer's recommendations complete in all respects. Cables are ferruled for proper maintenance / checking / wiring of panel. Detachable cable gland plates are provided. The panel will be equipped as follows: |
| 150 | (i) Contactor MLof suitable capacity |
| 151 | (ii) Copper bus bar of current rating up to 100 Amp |
| 152 | (iii) Sensitivity relay set with suitable CTs |
| 153 | (iv) Electronic latch circuit with tripping indication |
| 154 | (v) Instantaneous tripping device for complete panel over current 0.5 AMP. |
| 155 | (vi) Reset facilities for complete protection of AMF Panel |
| 156 | (vii) Self sequential starting relay unit 12 Volts DC complete with alarm contactor. |
| 157 | (viii) Electronic timer 220 Volts for main contactor with 1 No. NC auxiliary contacts |
| 158 | (ix) Electronic timer 220 Volts but for fuel cut operation with 1 No. NC auxiliary contacts. |
| 159 | (x) Battery charging unit 12/24 Volts 10 Amp complete with digital volt meter & Amp meter. |
| 160 | (xi) All as per item No-(ix) here in befor but for fuel cut off operation. |
| 161 | (xii) Electric starter 12 Volts DC as manufacturer's design. |
| 162 | (xiii). Digital voltmeter 0-500 volts panel mounting type size 96mm square with selector switch digital |
| 163 | (xiv) 3 phase electronic energy meter for measuring meter for measuring generated units . |
| 164 | (xv) Frequency meter digital type |
| 165 | (xvi) Suitable type of MCCB for main supply/DG Supply adjustable over load and adjustable short circuit . |
| 166 | (xvii) The AMF panel shall have by pass arrangement in case failure of bypass AMF panel |
| 167 | (xviii) Acoustic enclosure with natural air curculation without loss of any power to ventilation fan. The enclosure shall be modular in construction with hinged bolted structure to provide easy dismantling and shall be made out of high quallity CRCA steel sheet of 1.6mm thick with sufficient accessories for maintenance work openable and lockable door air tight gasket interior lightening arangement of 20W fitting with On / Off switch to meet latest emission norms. |
| 168 | (xix) Fuel tank of suitable capacity with inlet and outlet connectiions and fuel level indicator as per OEM. |
| 169 | (xx) Base frame made out of suitable channel duly reinforced and provided with adequate numbers of anti vibration pads to ensure minimum vibration as recommended by manufacturer. Note : Testing of DG set shall be done complete all as specified and directed by testing officer. Cost of fuel consumption during testing of DG Set shall deemed to be included in the quoted rates. |
| 170 | :Supply install testing and commissioning factory made LT panel board indoor type (CPRI approved) made out of 2 mm thick sheet metal angle iron base frame suitable for AC 3 phase 4 wire 50 HZ supply IP 54 complete. The Panel must be dust proof , vermin proff, powder coated finish fron and back opening platform of suitable size with shutter and locking arrangement for each switchgear and busbar of aluminium conductor suitable shape and size for 3 phase rating of 100 amps the follwing switchgear & controls. Incoming :-(a) 3 Phase 4 wire 50 Hz MCCB 4 Pole 415 V 40 Amps -2 Nos. (b)Ammeter 0- 1000 Amps 96 mm x 96mm electro mechancial type with three way ON/OFF rotary type selector switch and 3 current transformer of suitable ratio and capacity Qty 1 No (c) Indicating lamps for three phases Qty 1 set of 3 Nos (d) Voltmeter 0 - 500 Volts 96 mm x 96mm electro mechanical type with 3 way ON/OFF rotary type selector switch - Qty 01 No make AE/Rishab /Meco/Enercon). Outgoing:- (a) 4 pole MCCB 40 Amp, 50 HZ, 415 V, 25 kA -02 nos. (b) DOL Starter - 2 Nos. |
| 171 | Supply, install, testing & commissioning of Centrifugal Monoblock Pump set of cast Iron impeller with gland packing coupled with induction moter with ‘F’ Classs insulation and IP 55 protection suitable for 3 phase, 300 to 415 Volts, 2900 RPM, discharge not less than 5 lps at minimum 36 meter head with power rating 3.73 KW and 5 HP, impeller, delivery casing and moter body made of cost iron, pump shaft made of carbon steel, sealing with gland packed. Suitable for suction from pipe of size 50 mm dia and delivery to pipe of size 40 mm dia including of Star delta starter of brand Schneider with single phase preventer and over load protection , with provision of 3 crore 10 Sqmm Flat copper cable from starter pannel to pump set, priming line watering arrangement complete using 20mm dia GL pipe Med grade of length upto 10 RM, gate valve 20mm dia- 10 No with necessary PCC foundation with suitable size of nuts, bolts grouted & washers and complete all as specified and as directed and The rates are inclusive of testing of pump set installation for satisfactory functioning / running & minimum 2 years warranty complete all as specified and directed . Make:-Kirloskar / Crompton / GE |
| 172 | SEWAGE DISPOSAL |
| 173 | M&L for loose filling broken sewer bricks / brick bats as in soakage pits / soakage wells complete all as specified and directed. |
| 174 | M&L preparation of newly plastered or unplastered surface and applying two coats of weather proof paint to external surface of wall (Apex ultima) complete all as specified and directed. |
| 175 | AIR CONDITIONING & REFRIGERATOR :- |
| 176 | Supply, installation and commissioning BEE 5 star rated , double door Refrigerator of capacity 280 ltr, smart invertor frost free complete with humidity control, smart inverter Compressor, smart connect,Jet Ice, anti bacterial gasket working on single phase 230V, 50Hz all complete all as specified and directed. |
| 177 | Supply, installation and commissioning BEE 5 star rated , double door Refrigerator of capacity 220 ltr, smart invertor frost free complete with humidity control, smart inverter Compressor, smart connect,Jet Ice , anti Bacterial gasket working on single phase 230V, 50Hz complete all as specified and directed. |
| 178 | Supply, installation and commissioning of Deep freezer hard top of 150 ltr capacity working on single phase supply i.e 230V,50 Hz having single door, cooling range 18 degree centrigrade to 22 degree centrigrade, including locking arrangement with recess handle for durability, heavy duty castor wheels at bottom of freezeer with high density puff insulation for better holding time for items kept inside complete all as specified and directed. |
| 179 | Supply, installation and commissioning Stablizer for automatic operation single phase naturally air cooled indoor type & drsinged for input variation between 170V to 250V with output voltage stablized at 230 V with accuracy of + 2.5% of 1 kVA complete all as specified and directed. |
| 180 | SOLAR WATER HEATING SYSTEM :- |
| 181 | Supply & Fixing water Heater (Geyser) , Storage type electric of 25 Ltr capacity, BEE 5 Star rating, including fixing on wall with fasteners, nuts and bolts etc., PVC connection pipe of required length for hot and cold water supply complete all as per specified and directed. |
| 182 | Soil Investigation |
| 183 | Boring in any kind of soil upto a minimum depth of 10.00 (Ten) Metres from formation surface in cutting, including collection of distrubed and undistrubed sample at every 0.30 Metre or change of cohesive soil only, for conducting standard penetration test as per IS 2131-1985 and IS:2132-1985 at intervals/locations as directed by PM, alternative thereafter or on change of strata and identify SPT values, strata, maximum flood level and ground water level, finding angle of friction for cohesive soil collected in drained and un-drained conditions and triaxial tests on specimens at various depths from ground level upto 10 (Ten) Metres (Minimum) including the following tests, complete all as specified and directed. (i) Standard Practice for dry preparation of soil sample for particle size analysis as per IS:2720 (Part-I) 1963. (ii) Liquid limit, Plastic limit and Plasticity Index of soil as per IS:2720 (Part-V) 1975. (iii) Moisture Density relation of soil as per IS 2720 (Part-II) 1973 (iv) Specific Gravity (v) Bulk and Dry Density (vi) Free Swell Index and swelling pressure of soils as per IS 2720 (Part-XL) and IS 2720 (Part-XLI) (vii) Determination of permeability of soil as per IS 2720 (Part-36) 1987 and IS 2720 (Part-13) 1986 (xviii) Determination of organic material in soil by wet combustion as per IS 2720 (Part-XXII) 1972 (ix) Soil Classification Note: Quoted rate shall be deemed to be inclusive of the cost of mobilization all necessary equipments for boring and sample collection, testing charges for sample from the approved sources and submission of requisite test reports in quadraplicate, complete field work and laboratory test result including reccommendations for type of foundation , safe bearing capacity, whether effect of height of water table have considered in working out SBC, suggested size and depth of foundation for RCC structure. |
| 184 | Retaining wall |
| 185 | Design, Supply, fabrication, assembling, placing in position and filling of Gabion Boxes of sizes made from Mechanically woven double twisted hexagonal steel wire mesh conforming to IS 16014:2012 and MORTH clause 2500, mesh type 10 x 12 cm with mesh opening tolerance of (-02% to +2%), mesh wire dia 2.7/3.7mm (ID/OD) and selvedge wire dia 3.4/4.4mm (ID/OD), heavily coated with Zn + 10% AI Alloy with polymer coating, including diaphragms at 1.0 mtr interval, lacing/binding wire 2.2/3.2 mm (ID/OD), all necessary dressing, assembling, stretching, tying, placing in position including filling with approved hard stone/boulders, hand packed to obtain proper shape and alignment, complete all as specified and directed. Note :- Design methodology shall be as per IRC : SP : 116-2018 guidelines. The design and drawings of Gabian boxes shall be duly proof checked and vetted by IIT/NIT or any Govt Engineering Institute approved by Accepting Officer. |
| 186 | Supply & laying of bi-axial extruded polypropoylene thermo calendared UV stabilised needle punched Geotextile fabric sheet 400 gsm, 3.00mm thick conforming to ASTM standards for incorporation in back fill of retaining/Gabian wall, unrolled, stitched, wrapped, tied, anchored in straight or curved locations all as directed and shown at site by Dy PM/PM. |
| 187 | Preparation and submission of detailed structural design, design calculation and working drawings for RCC retaining wall of varying heights upto 10 mtr, based on approved soil investigation/ SBC report and site conditions, including stability analysis against sliding, overturning and bearing pressure, design of foundation and structural components, preparation of reinforcement detailing and bar bending schedules, complete duly proof checked and vetted by IIT/NIT or any Govt Engineering Institute approved by Accepting Officer including incorporation observation/comments and obaining final approval from Accepting Officer complete all as specified and directed Total in Figures 0.0 0.0 4.0 Construction of chamber for 100mm sluice plates item5 10.0 Nos Quoted Rate in Figures Select 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jun 18, 2026
11:30 IST
Tender Published
Tender notice published.
Completed
Jul 21, 2026
18:00 IST
Corrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 20 daysJul 21, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 20 daysJul 28, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 27 days