| 1 | Erection of I1KV OH line by using 80mm2 AAAC & 6nos 11Mtr WPB Poles =0.175Km (5-Spans) (C-D) (C.P=2nos.) - 11mtrs WPB Pole with Base Plate (30.44Kg/m) |
| 2 | 9Mtr 100x116mm joist pole (23Kg/Mtr) asstud pole |
| 3 | Stud Clamp |
| 4 | GI base plate (500x500x10mm) @20Kg/Pc |
| 5 | Earthing device Coil type |
| 6 | No-8 GI wire (Dia 4.6mm) 0.131 KG/ Mtr.- 2Mtr. For connecting pole with Coil earthing |
| 7 | 11KV V Cross arm (10.2 Kg each) |
| 8 | GI Back Clamp for 11KV 'V' Cross Arm |
| 9 | 11 KV F clamp 2.9 Kg |
| 10 | 11KV Pin insulator Polymer |
| 11 | 100x50x6 mm channel for straight Crossarm 1.2 mtr each 2 no & 0.2 mtr long 2 No. including tapping point |
| 12 | Disc insulator (B&S) 70KN polymer |
| 13 | Hardware fitting 70KN (3Bolted) |
| 14 | PG Clamp for 80mm2 AAAC |
| 15 | 80mm2 AAAC |
| 16 | HT Stay Set |
| 17 | Stay Wire (7/10 SWG) |
| 18 | Stay Insulator |
| 19 | Stay Clamp |
| 20 | G.I nuts, bolts and washers |
| 21 | Anticlimbing Device (GI barbed wire 3kg per support) ’ |
| 22 | Back Clamp for danger Plate 25X3 mm. flat 0.59Kg/Mtr. Flat of 0.510mtr length 4 no's = (4x0.59x0.510) |
| 23 | Danger board |
| 24 | Back Clamp for danger Plate 25X3 mm. flat 0.59Kg/Mtr. Flat of 0.510mtr length 2 no's = (2x0.59x0.510) |
| 25 | Black Paint |
| 26 | Yellow colour paint for Back ground |
| 27 | Sundries (Clamp, connector, binding, Tape etc) |
| 28 | Construction of I1KV OH line with 3Cx50mm2 XLPE Cable = 0.025KM (l-Span) (Single Circuit) (From D-A) - 3Cx50mm2 11KV XLPE Cable (Armoured) |
| 29 | Heat shrinkable jointing kit suitale for 3Cx50 mm2 11KV XLPE Cable (out door type) |
| 30 | GI pipe Earthing 40 mm dia medium gauge(3.25 mm thick ness) 3 mtr long |
| 31 | Dead End Clamp |
| 32 | Eye Hook for (XLPE Cable) |
| 33 | Pole clamp for eye hook for XLPE Cable |
| 34 | XLPE Cable clamp to hold support wire |
| 35 | 7/12 GI Stay Wire for supporting Cable |
| 36 | 9 KV 10KA 11 KV Lighting Arrestor |
| 37 | 25 x 4 mm GI flat (For Lightning arrester) |
| 38 | 75x40x6mm GI Channel for LA |
| 39 | G.I nuts, bolts and washers |
| 40 | Sundries (Clamp, connector, binding, Tape etc) |
| 41 | Construction of 11KV DP for MU=1 No. - 11mtrs WPB Pole with Base Plate (30.44Kg/m) |
| 42 | Earthing device Coil type |
| 43 | Top Pressure Channel 100 x 50 x 6mm GI channel each 2.8 mtr. Long 2Nos @9.2Kg/mtr |
| 44 | Metering unit mounting chhanel l00x50x6mm GI channel each 2.8mtr. Long 2Nos @9.2Kg/mtr |
| 45 | 75x40x6mm GI Channel for bracing 2.8mtr long 2Nos @6.8Kg/mtr |
| 46 | 50x50x6mm GI Angel for cross bracing 4mtr long 2Nos & 4.5Kg/mtr |
| 47 | 9 KV 5KA 11 KV Lighting Arrestor |
| 48 | G.I nuts, bolts assorted size |
| 49 | GI pipe Earthing 40 mm dia medium gauge(3.25 mm thick ness) 3 mtr long |
| 50 | 25x6 mm GI Flat (@1.2kg/mtr) |
| 51 | HT Stay Set Complete |
| 52 | HT Stay Set Insulator |
| 53 | HT Stay Set Clamp |
| 54 | 7/10 SWG Gl Stay wire |
| 55 | Anticlimbing Device(G I barbed wire 3kg per support} |
| 56 | Back Clamp for anticlimbing device 25X3 min. flat, 0.S9Kg/Mtr. Flat of 0.5l0mfr length 8 no's = (8x0.59x0.510) |
| 57 | Danger plate |
| 58 | Back Clamp for danger rlate 25X3 mm. flat, 0.S9Kg/Mtr. £lat of 0.510natr length 2 no's = (2x0.59x0.510) |
| 59 | Black paint |
| 60 | Yellow colour paint for back ground |
| 61 | Sundries for clamp, connector, bind tape etc. |
| 62 | Erection of 11KV line by using 3Cx50mm2 XLPE cable= 0.05Km (Double Circuit) (1-Span) (A-B) - Cement Concrete for Stay Anchor plate / stud CC foundation 1:3:6 size by using 4cm size HBG metal= (0.45 x0.45x1.5)mtr=0.3037Cum. 04158.84=1263.03 or 1270.00 |
| 63 | Concreting of poles in ratio 1:1.5:3 for 11MtrWPB Poles |
| 64 | Couping of poles in ratio 1:1.5:3 for 11MtrWPB Poles |
| 65 | Concreting of poles in ratio 1:1.5:3Joist Poles |
| 66 | Materials for Massionary work for Earth Pit,CharcoaI, Salt etc including construction of earthing chamber (Size: 2\\"x2\\") and RCC slab cover |
| 67 | Dismantle of HT Pole at C |
| 68 | Survey of incremental/delta network and assets changes of I1KV network and updation in GESW database |
| 69 | Installation of 15/5A Metering Unit=1No - Sundries |
| 70 | Installation of 250KVA, 11/0.4KVA Plinth mounted S/S-1 No. - 11mtrs WPB Pole with Base Plate (30.44Kg/m) |
| 71 | Earthing device Coil type |
| 72 | Top Pressure Channel (100x50x6)mm (9.2 Kg/Mtr) Rs.10.00 added for Galvanistaion |
| 73 | AB Switch mounting channel (100X50X6)mm (9.2 Kg/Mtr) |
| 74 | HG fuse mounting channel (75X40X6)mm (6.8 Kg/Mtr) Rs.10.00 added for Galvanization |
| 75 | Channel for cantilever arrangement (75X40X6) (6.8Kg/mtr.)Rs.10.00 added for Galvanization |
| 76 | Angle for cantilever arrangement (50X50X6)mm(4.5 Kg./Mtr.)Rs.10.00 added for Galvanization |
| 77 | DP Bracing Channel (100x50X6)mrn (9.2 Kg./Mtr.)RS.10.00 added for Ga1vanization(4 Nos.) |
| 78 | DP Bracing angle (50X50X6) mm 7Mtr. (4.45 Kg./Mtr.)RS.10.00 added for Galvanization |
| 79 | Angle for mounting LT distribution box (50X 50X6)mm(4.3 Kg./Mtr.)Rs.10.00 added for Galvanization |
| 80 | 400Amp 3 pole AB Switch |
| 81 | 400Amp 3 pole HG Fuse |
| 82 | LA (9KV,5KA class) |
| 83 | 11KV Disc insulator (B& S) 70 KN, Polymer |
| 84 | HW fitting (B & S) 70KN 3 bolted |
| 85 | 11KV Pin insulator Polymer |
| 86 | H.T Stay set |
| 87 | 7/10 SWG G.I stay wire |
| 88 | Stay Insulator |
| 89 | Stay Clamp |
| 90 | GI pipe earthing 40 mm dia medium gauge 2.5 mtr long. |
| 91 | 25x4mm GI flat for sub station earth |
| 92 | 50x6mm GI Flat for Neutral earthingof 250KVA |
| 93 | LT Distribution box with MCCB, Alluminium Busbar for 3 Bay with Kit kat fuse for 250KVA S/S |
| 94 | 250 KVA ,11/0.4 KV(AL) Transformer with tap changer BIS Energy level -II |
| 95 | GI Nut Bolt & Washer |
| 96 | 80mm2 A AAC conductor for jumpering |
| 97 | 1Cx300 mmsq LT XLPE Cable(Armored) |
| 98 | G.I Barbed Wire anticlimbimg device 3. kg per support |
| 99 | Back Clamp for anticlimbing device 25X3mm flat, 0.59Kg/Mtr. Flat of 0.510mtrlength 4 no's = (4x0.59x0.510) |
| 100 | Danger Board |
| 101 | Back Clamp for danger Plate 25X3 mmflat, 0.59Kg/Mtr. Flat of 0.510mtr length 2 no's = (2x0.59x0.510) |
| 102 | Black paint |
| 103 | Yellow colour paint for back ground |
| 104 | Sundries for clamp, connector, bind tape etc. |
| 105 | Civil Part - Cement Concrete for Stay Anchor plate / stud CC foundation 1:3:6 size by using 4cm size HBG metal= (0.45 x0.45x1.5)mtr=0.3037Cum. 04158.84=1263.03 or 1270.00 |
| 106 | Concreting of poles in ratio 1:1.5:3 for 11MtrWPB Poles |
| 107 | Couping of poles in ratio 1:1.5:3 for 11MtrWPB Poles |
| 108 | Materials for Massionary work for Earth Pit,CharcoaI, Salt etc including construction of earthing chamber (Size: 2\\"x2\\") and RCC slab cover |
| 109 | Brick work with F.P.S. bricks of class designation 75 in Foundation and plinth in Cement mortar 1:6 (1 Cement : 6 Coarse sand) as per TPSODL specifcation. Scope includes supply of all material with Locking arrangement ( for 14 Running material) |
| 110 | Civil cost for making TRF plinth from 250KVA of upto I000KVA.BA has to provide necessary civil material,manpower, machinary for construction of plinth as per standard drawing |
| 111 | Survey and digitization oi New DSS and its intervals including attrubutes |
| 112 | Survey and digitization of new klCCB/ LTDB and its internals including attrubutes Please Enable Macros to View BoQ information |