| 1 | Taking down carefully copper/aluminium any type of point wiring (light/fan/socket /power) complete (fittings such as switches, ceiling roses, holders, sockets,regulators light fittings) and removal from site and making good the disturbed surfaces of (wall/floors/ceiling etc) complete all as specfied & directed. |
| 2 | M&L for point wiring with PVC FRLS insulated multistranded unsheathed cable 1.5 Sqmm size with stranded copper conductor, 1100 volts grade conforming to IS:694 drawn in an existing conduit or as per site requirement making good the surfaces as per existing surfaces with concealed sunk in pressed steel/GI terminal boxes of 1.6 mm thick factory made fixed with brass screws and cup washers including single core stranded copper conductor 1.5 sqmm PVC insulated unsheathed cable as earth wire to common earth and connected to earth dolly drawn in an existing conduit or as per site requirement completed all as specified for the following:- |
| 3 | One light/fan/bell/Exhaust fan/Fresh Air Fan point controlled by one way switch 5 amps. |
| 4 | M&L for point wiring using approved colour coding as per IS (Red, Black and Green for single phase circuits), with multi stranded copper conductor 1.5 sqmm nominal cross sectional area, single core, PVC insulated and unsheathed FRLSH cable 1100 volts grade, ISI-694 marked with valid CML No in and including medium grade, PVC concealed conduit of dia not less than 20 mm and conduit accessories concealed in wall (Brick/stone masonary), ISI marked with valid CML No (IS-9537-1983 for conduits and IS: 3419:1976 for conduit accessories), with modular metal flush boxes of size 1.6 mm thick including cover plate with frame of white colour of suitable size as required at site, including PVC insulated multi stranded copper conductor 1.5 sqmm nominal cross sectional area single core FRLSH cable as earth continuity conductor to common earth and connecting to earth duly complete including replastering and making good the surface of wall and painting with existing colour all as specified and directed at site for the following: |
| 5 | One light/fan/bell/Exhaust fan/Fresh Air Fan point controlled by one way switch 5 amps. |
| 6 | M&L for point wiring using approved colour coding as per IS (Red, Black and Green for single phase circuits), with multi stranded copper conductor 4.0 sqmm nominal cross sectional area, single core, PVC insulated and unsheathed FRLSH cable 1100 volts grade, ISI-694 marked with valid CML No in and including medium grade, PVC concealed conduit of dia not less than 20 mm and conduit accessories concealed in wall (Brick/stone masonary), ISI marked with valid CML No (IS-9537-1983 for conduits and IS: 3419:1976 for conduit accessories), including PVC insulated multi stranded copper conductor 4.0 sqmm nominal cross sectional area single core FRLSH cable as earth continuity conductor to common earth and connecting to earth duly complete including replastering and making good the surface of wall and painting with existing colour all as specified and directed.(For AC point) |
| 7 | Identifying and rectifying the defects pertains to ceiling fans/exhaust fans/fresh air fans and connects electric circuit, tightening of loose wiring/conduits/ fan capacitors and connection carrying out minor repairs incl blade alignments,screwing/tightening the nuts/bolts/washers etc incl taking down & refixing properly in the same position after repairs, complete all as specified and directed. |
| 8 | M&L for rewinding of ceiling fans of any type and make with super enamelled copper wire of appropriate gauge suiatble for existing make in the workshop including necessary lathe work on shaft, both sides of rewinding covered with high quality varnish and provisions of new nuts/pins including taking out old burnt wind of copper/aluminium complete all as specified and directed. |
| 9 | Ditto- all as per Item No. 6 here-in-before but Air ventilation PVC body/ metal body exhaust fan of size 200/230/300 mm sweep. |
| 10 | M&L for overhauling of celing fan 1200mm/1400mm by greasing and oiling,replacement of unserviceable/defective components, except rewinding of starter winding complete all as directed. |
| 11 | Note Sl.No. 6 : (a) Spare parts found unserviceable/defective will be measured and paid separately under relevant item as Supply and fix in repair . |
| 12 | Supply in repairs/replacements of following spare of Ceiling fan 1200mm /1400mm sweep of different make :- |
| 13 | S&F in repair MS clamp with rubber reel, nuts, bolts, split pin etc suitable for 1200/1400 mm sweep ceiling fan complete all as specified and as directed. |
| 14 | Ball bearing of size 6201/6202 as per sample complete all as specified and directed. |
| 15 | Gun metal bush as per sample. |
| 16 | Fan canopy pvc body, white in colour, suitable for existing fan, as per sample and directed. |
| 17 | Ceiling fan blade 1200 mm sweep made up of aluminium body having provision of free size monting nuts/screw all as per requirement at site complete all as specified and directed. |
| 18 | S&F in repair of MS down rod 300/450 mm for fixing of ceiling fan complete all as specified and as directed. |
| 19 | S&F in repair stainless steel louver shutter of exhaust fans suitable for 300 mm size at the height from 3 mtr to 14 mtr making good surface of disturbed area including taking down old louver shutters complete all as specified & directed.Note: Contractor shall arrange suitable T&P including necessary form work, scaffolding and safety measures to fix properly the exhaust fan shutter complete all as specified and directed. |
| 20 | M&L for Overhauling/Dismantling of defective/rusted Geyser of 25 Ltr capacity, removing inlet/outlet connections, taking out U/S parts by unscrewing bolts and nuts etc. Checking defects and re-assembling the Geyser after refixing serviceable/new parts & cleaning, dicling and refixing only serviceable items and re-installing the Geyser in suitable place/position and connecting inlet-outlet connections & testing complete, all as specified and directed by Engr-in-charge.Note:(a) Items required for replacement of U/S parts will be measured and paid separately under relevant item of sch \\"A\\" ). |
| 21 | Supply in repairs/replacements of following spare parts of geyser storage type of different make for capacity 25 ltrs all as samples as required. |
| 22 | Apparatus assembly duly prewired without heating element and thermostat/thermal cutout. |
| 23 | Indication lamp (Green/Red) as per sample. |
| 24 | Thermostat as per sample. |
| 25 | Heating element 2.0 KW round, square, triangular bottom suitable for 25 Ltrs or as per sample complete all as specified and directed. |
| 26 | Cover outer for geysers suitable for any make/capacity/type of Geysers installed at site duly painted with two quotes with enamel (Deco) paint of colour & shade complete all as specified and directed |
| 27 | Stainless Steel inner tank of 25 Ltrs capacity complete all as specified and directed as . |
| 28 | Bottom and top cover for Geysers suitable for any make/capacity/type of Geysers installed at site duly painted with two quotes with enamel (Deco) paint of colour & shade complete all as specified and directed. |
| 29 | Geyser SS braided pipe of 12 mm (internal dia) suitable for hot/cold water, 600 mm long with nuts and rubber washers complete all as specified and directed. |
| 30 | S&F in repair RCBO, 230 Volt, 40 Amp, 30mA, 50 Hz, with 10 kA short circuit capacity of double pole for ensuring protection from leakage current, short circuit & over load, complete all as specified and as directed. |
| 31 | Taking down carefully sub main wiring three single run 6/10 Sqmm of any make and type complete all as directed. |
| 32 | Supply, laying and drawing submain wiring in and including 20 mm dia concealed PVC rigid conduits including cutting of chases for laying conduit making good the surfaces as per existing surfaces or as directed on walls 02 runs of IC x 6.00 sqmm (Main Cable and neutral) and one run of IC x 6.0 sqmm (as earth wire) of multistranded copper conductor PVC insulated, FRLSH, unsheathed cables of 1100 volts grade conforing to IS : 694 of 2010 complete including connection all as specified and directed. Note :- Two runs of IC x 6.00 sqmm (Phase wire and neutral ) and one run of IC x 6.00 sqmm (as earth wire) will be measured as one unit length. |
| 33 | Taking down DBs,VTPN DBs of any make and type from the site and making good to the disturbed surfaces complete all as specified and directed. |
| 34 | S&F in repair factory made epoxy polyester powder coated distribution board TP & N 4 way (VTPN MCCB DB) with metal double door (IP-54 & IK 09 protection) fabricated from minimum 1.6 mm thick CRCA sheet and fixed on wall and suitable for universal mounting and including 100 Amps copper bus bar, Neutral bar, standard DIN rail, earth bar and cable ties for cable management, top and bottom removable gland plates with provn for 100 Amps, 4 pole MCCB and ELM as incommer and 12 SP MCBs outgoings including blank spacer for blank space complete all as specified and conforming to IS: 8623 including taking down old DBs all as specified.NOTE :-(a) MCBs/MCCBs shall be measured and paid separately.(b) All cables terminating into MCBs shall be connected by using suitable copper lugs/thimbles/sleeves and its cost shall be deemed to be included under respective item of Sch. |
| 35 | S&F in repair MCCB 125 Amps, 4 Pole 415 volts 16 KA 50 HZ complete all as specified and directed. |
| 36 | S&F in repair sheet metal enclosure SP and Neutral with a two pin earth plug and socket complete with a MCB SP 20 Amp 220 volts, 50 Hz, 10 KA breaking capacity complete all as specified and directed. |
| 37 | S&F in repair copper wind motor, single phase, 240V suitable for PVC fresh air fan of sweep size 225/ 250/300 mm as per sample given at site complete all as specified and directed. |
| 38 | S&F in repair copper wind motor, single phase, 240V suitable for metallic heavy duty exhaust fan of sweep size 250/300/400 mm as per sample given at site complete all as specified and directed. |
| 39 | S&F in repair copper cable flexible 2 core PVC insulated of size 40/.0076 ll complete all as specified and directed. |
| 40 | S&F in repair Fresh Air Fan made of sturdy Engineering plastic complete with louver shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 200/250 mm sweep, single phase,including cutting of holes in wall/windows for fixing the fresh air fan complete all as specified and directed. |
| 41 | S&F in repair Nut and Bolt full thread hexagon bolt mild steel of size (1/2x6) inch alongwith washer suitable for fixing of Geyser 25 ltrs. complete all as per site requirement all as specified and directed. |
| 42 | M&L for taking down & refixing and repair of BLDC ceiling fans of any type and make complete including repair/replacement of PCB & ball bearing as requirment and provisions of new nuts and pins for 1200 sweep as per site reqiurement complete all as specified and as directed. |
| 43 | M&L in repair switch piano flush type 6 Amp SP one way complete all as specified and directed. |
| 44 | M&L in repair ceiling rose 3 phase PVC polycorbonate,insulated body complete all as specified and directed. |
| 45 | S&F in repair switch type normal electronic fan regulator 5 step complete all as specified and directed. |
| 46 | M&L in repair Modular switch 1 way 6A,1 module, 230V, 50 Hz complete all as specified and directed. |
| 47 | S&F in repair Modular ceiling fan regulator, step type for BLDC ceiling fan 1 or 2 module. (As per sample) |
| 48 | S&F in repair metal plug top 20 Amps 3 pin 230 volts complete all as specified and directed. |
| 49 | S&F in repair PVC plug socket 20 Amps 3 pin 230 volts complete all as specified and directed. |
| 50 | S&F in repair 15A plug top 240 Volt AC and connection complete all as specified and as directed |
| 51 | S&F in repair ceiling fan capacitor for 1200/1400 mm sweep 2.5 mfd all specfied and directed Please Enable Macros to View BoQ information |