| 1 | Notes for whole BOQ : (i) The complaints in respect of AC and other equipment to be repaired under this contract shall be registered by contractor at the E/M complaint cell of AGE E/M (ii) Stationary required such as complaint book, job cards etc shall be arranged by the contractor and proper record shall be maintained by the contractor.(iii) Tools, Technician with helper and Transport with driver for attending of all the complaints shall be arranged by contractor. (iv) The rate quoted by the contractor for the items of BOQ shall be inclusive of cost of works under note (i) to (iii) above. (v) The said complaints shall be rectified within 12 Hrs of the registration of the complaints failing which recovery of Rs.1000/ per complaint per day shall be made for contractor's due payment (vi) The stores/item required for the comlaints shall be measured separately under relevant items of BOQ(vii) The repair of AC and other equipment shall be carried out a trained ITI qualified technician only. |
| 2 | Material and labour for Descaling of condenser tubes required to meet the designed pressure conditions and cooling specifications for desired rate of flow of refrigerant in compressor and water in condenser including circulation of chemical inside tubes and cleaning tubes, provision of new gaskets, in every 03 months etc complete all as specified and directed. Note : Spares required to be measured and paid separately under relevent items. |
| 3 | 52 TR capacity at Signal Center |
| 4 | 52 TR capacity at OPS Room |
| 5 | 15 TR capacity at 4 ASD |
| 6 | Supply and charging compressor oil conforming to IS 4578 or any other relevant IS for synthetic oils (of any make to be approved by GE in writing) including flushing/cleaning of oil chamber etc complete all as specified and directed. Note: (i) Oil shall be brought by the contractor at site from authorised dealer/manufacturer company in sealed canes of standard packing with test certificate and purchase Vrs.(ii) Re-filling shall be done in the presence of Engr-in-Charge. |
| 7 | Nitrogen testing for the any capacity of compressors including condensing unit and gas piping complete as per the manufacturer instructiions and entire satisfaction complete all as specified and directed. Note :- (i) Nitrozen pressure should be held with out any drop in pressure inside the unit continue for 24 hrs after leakage testiing required gas will be fill and satisfaction of the Engineer in Charge. |
| 8 | S & F in repairs flexible twin core 4076 with copper conductor including connecting fan complete all as specified and directed. |
| 9 | Supply and filling Refrigerant gas R-407 of 11 Kg Each cylinder for AC plant compressor complete all as specified and directed. |
| 10 | Supply and filling Refrigerant gas R-22 of 11 Kg Each cylinder for AC plant compressor complete all as specified and directed. |
| 11 | M&L dismantling electric motor of any make, 3 phase 415V of following capacity, opening the motor for rewinding using super enamelled copper wire of suitable gauge to match with the existing winding as per manufacturer design including varnishing & drying and re-assembling the motor, connecting with proper alignment and testing complete including transporting to workshop for rewinding complete all as specified and directed. |
| 12 | 10 HP |
| 13 | 7.5 HP |
| 14 | 1 to 3 HP |
| 15 | M & L for Servicing of water pump split casing type set by removing & dismantling pump and connected pipes & electric connections etc and replacing of unserviceable parts with new gland packing set Gun metal bushes, bearing, water seal packing complete cleaning of impeller greasing etc reassembling and refixing in original position complete with packing and necessary nut & belt etc including testing for smooth functioning etc of following capacity complete all as specified and directed. |
| 16 | 10 HP |
| 17 | 7.5 HP |
| 18 | 1 to 3 HP |
| 19 | Supply and fixing in repair/replacement power assembly expansion valve for up 52 TR AC palnt at EHU / ERS complete all as specified and directed. |
| 20 | Supply and fix of V-belt size A-68 including taking down old belt . |
| 21 | All as above Ser item No 10 as above but of size A-46 . |
| 22 | All as per Ser item No 10 as above but of size B- 78. |
| 23 | Realignment of compressor and motor of any capacity on existing foundation complete all as specified and directed. |
| 24 | Supply and fixing of CI butterfly valves with matching flanges,gaskets,hardware duly insulated with preformed pipe section fabricated to shape and bonded with adhesive. removable cover is required valves in 26swg aluminium sheet,cover should be divided in to portions quick release toggles shall be used for assembly of covers complete all as specified and directed. |
| 25 | 50 mm bore. |
| 26 | 65mm bore. |
| 27 | Supply and fix High pressure control switch type MP-5 including taking down old switch complete all as specified and directed. |
| 28 | Supply and fix oil pressure control switch type MP-55 including taking down old switch complete all as specified and directed. |
| 29 | Supply and fix low pressure control switch type MP-01 including taking down old switch complete all as specified and directed. |
| 30 | Supply and fix LP/HP cut out type MP-15 inlcuding taking down old cutout complete all as specified and directed. |
| 31 | All as above Ser item No 18 but type ML-4 |
| 32 | All as above Ser item No 18 but type ML-3 |
| 33 | All as above Ser item No 18 but type ML-2 |
| 34 | All as above Ser item No 18 but type ML-1.5 |
| 35 | Supply and fixing power contract assembly complete MNX-25 complete all as specified and directed. |
| 36 | Supply and fixing power contract assembly complete MNX-12 with one NO and NC complete all as specified and directed. |
| 37 | Supply and fixing power contract assembly complete MNX 32 including taking down old contactor complete all as specified and directed. |
| 38 | Supply and fixing spare Kit without coil type MU-1 including taking down old kit complete all as specified and directed. |
| 39 | All as above Ser item No 26 but type ML-1.5 |
| 40 | All as above Ser item No 26 but type ML-2 |
| 41 | All as above Ser item No 26 type ML-3 |
| 42 | All as above Ser item No 26 but type ML-4 |
| 43 | Supply and fixing Overvload relay range 9-15 amps suitable for ML-1/ML-1.5 contactor complete all as specified and directed. |
| 44 | Supply and fixing Overvload relay range 20-33 Amps suitable for ML-2/ML-3 contactor complete all as specified and directed. |
| 45 | Supply and fixing Overvload relay range upto 7.5 Amps suitable for MNX contactor complete all as specified and directed. |
| 46 | Supply and fixing indicator lamp assembly complete LED type suitable for the existing system supply voltage for the existing system supply voltage 230V / 440 V AC including taking down old lamp assembly complete all as specified and directed. |
| 47 | Supply and fixing in repair of MCCB 3 pole 415 volts AC , 400 Amps breaking capcity 36 KA, complete all as specified and directed. |
| 48 | Supply and fixing in repair of MCCB 3 pole 415 volts AC , 250 Amps breaking capcity 25 KA, complete all as specified and directed. |
| 49 | Supply and fixing in repair of MCCB 3 pole 415 volts AC , 100 Amps breaking capcity 25 KA, complete all as specified and directed. |
| 50 | Supply and fixing in repair of MCB 3 pole 415 volts AC , 40 Amps breaking capcity 25 KA, complete all as specified and directed. |
| 51 | Supply and fixing in repair of MCB 3 pole 415 volts AC , 32 Amps breaking capcity 25 KA, complete all as specified and directed. |
| 52 | Taking out old and unserviceable PVC fins of cooling tower of any capacity AC plant and replacing with new one including setting complete all as specified and directed. |
| 53 | Supply and fix in repair in repair DOL starter suitable for 5HP motor capacity 9 to 14 Amp complete with over load relay , single phasing preventer under volt release etc complete all as specified and directed. |
| 54 | Supply and fix in repair in repair DOL starter suitable for 10 HP motor capacity 14 to 23 Amp complete with over load relay , single phasing preventer under volt release etc complete all as specified and directed. Please Enable Macros to View BoQ information |
| 55 | Supply and fix in repair in repair DOL starter suitable for 10 HP motor capacity 14 to 23 Amp complete with over load relay , single phasing preventer under volt release etc complete all as specified and directed. Please Enable Macros to View BoQ information |