| 1 | Clear water Boosting P/Plant -W.T.P Campus at Rajpara |
| 2 | Cost towards supplying and laying of 240 sq.mm x 3.5 core XLPE aluminium armoured 1.1 KV grade cable from Transformer to main switch to panel board in the pump house.(Confirms to IS:7098,PART-1). |
| 3 | Cost towards opening, dismantling, cleaning and repairing and overhauling of 167 HP HSC C/F multi stage pump set having 1475 rpm head 197 mtrs. discharge 123m3/hr four impeller type Make- Mather & Platt (WILO) with following works:i. Complete dismantling of Pump set from base plate and opening & cleaning of Pump with all labour, tools and tackles.ii. Re-metaling, turning & finishing of SS pump shaft as per sample at lathe & fitting after repairing -01 No.iii. S.S. Shaft sleeves both sides- 02 Nos. as per sample.iv. Making neck-ring as per sample- 02 Nos.v. Cheek Nut- 01 No.vi. S/F coupling nut bolts as per sample-06 Nos.vii. Making of gland titener as per sample.-02 Nos.viii. Repairing of bearing housing -02 Nos.ix. Ball bearing as per sample-02 Nos.x. Ball bearing 6310-01 No.xi. Paper Packing, Nut-bolts as required. Complete re-assembling and overhauling of Pump, installing at site with all labour, tools & tackles and Testing on full load with transportation charge up & down etc. including the deduction of scrap materials all complete job. Make- Mather & Platt (WILO). |
| 4 | Supplying all labour tools and tackles for complete opening, dismantling, cleaning of its slots of stator by brush & petrol then complete rewinding of 167 H.P. 440 volts, 50c/s, Star delta, 3 phase, squirrel cage induction motor by supplying super enameled copper wire & then tapping, varnishing, heating & complete reassembling then testing on full load including the deduction of cost burnt copper Wires and transportation charges from p/plant to workshop and back to the same etc. all complete at WTP p/plant Rajpara.Wt. of Copper wire approx-38.00 kg. With changing of following bearing:- (i) Ball bearing-DE/NDE bearing 6319-C3 -01 No. (SKF Make) at c/w water p/plant. |
| 5 | Cost towards repairing & servicing of motor control panel with FASD starter – 2 nos. and 400 Amp, 415Volts MCCB -01 No. 320 Amp outgoing MCCB-02 Nos. with following works-i. Changing L&T MNX contactor –with L&T MNX contactor as Main contactor MNX-250ii. Star contactor MNX-185 -01 No. with Front & Side Add on Auxiliary contacts-(2NO+2NC)-02 nos. iii. thermal overload Relay MN(135-225)-01 No,iv. MNX 185 Contactor spare contact Kit-01 set v. MNX 185 Contactor spare contact Coil 240 Volt -02 set vi. Timer (12-120 sec)-01 No. (L&T Make) vii. ON-OFF push buttons-02 Nos. viii. 3 Ph LED Voltmeter CI 0.5-01 No.ix. 3 Ph LED Ampere meter CI 0.5 -01 No., x. Single phasing, reverse current, under voltage, over voltage protection relay-01 set each for both motor. xi. LED Phase indicating bulb-06 Nos., xii. Auto/Manual Selector switch-03 Nos.xiii. 4 sq. mm Single core copper cable-20 mtrs. for control wiring etc. with all fitting & electrician charges at P/Plant. |
| 6 | Supplying and fitting of 415 volt, S-D-F FN 630A TPN main switch and SS enclosure suitable for DIN fuse link with HRC fuses make L&T/ Havel’s/ C&S with all labour & tools and materials installing at pump house. |
| 7 | Supplying and fitting of 150 mm dia. Flange type C.I. foot valve having single leather flap and gun metal seating, Valve shall be fixed on suction side of pump as per requirement including jointing material and hardware as per IS:4038. |
| 8 | S/F of 150 mm dia. Double flange sluice valve confirming for IS – 2906/14846 including worn gear arrangement as per test pressure stainless steel spindle should be fixed filter unit pipe line including all required size nut bolt rubber insertion and transportation charge etc. all complete. |
| 9 | S/F of 150 mm dia. double flange NR valve confirming for IS – 5312Part-1(1984) including worn gear arrangement as per test pressure stainless steel spindle should be fixed on delivery line of motor pump set including all required size nut bolt rubber insertion and transportation charge etc. all complete. |
| 10 | S/F of 90/100 watt LED Flood lighting luminaire with pressure die cast housing and toughened glass cover , operating voltage range 100V-270V AC with structure, stand, clamp, tee, wires and switches etc. all complete. |
| 11 | S/F of 90/100 watt LED street lighting luminaire with pressure die cast housing and toughened glass cover , operating voltage range 100V-270V AC with structure, stand, clamp, tee, wires and switches etc. all complete. |
| 12 | Cost towards supplying and fitting of lightening arrester suitable for 11 kv Line for protection of transformer in place of damaged lightening arrester with copper wire etc. all complete job. |
| 13 | Cost towards supplying and fitting of lightening arrester suitable for building protection with Earthling Electrode, Earthling Compound, copper wires and earth work etc. all complete job. |
| 14 | Cost towards replacing of old damaged Cables passing through energy meter by MRT division of Electricity Department including meter shifting and testing charge with all labour, tools and materials. |
| 15 | Cost towards denting and painting of Electro-mechanical components as Motor Pump ,Panel board, Sluice valve, NR Valves ,Suction pipe line ,common header pipe line inside Pump Chamber with primer and two coat of Metal Oil paint as required at WTP boosting unit and Raw water p/plant. |
| 16 | For Back Wash Tank Unit |
| 17 | Cost towards replacing of old & damaged 5’’ dia. M.S. Suction Pipe-45 ft. each for both pump sets with MS Flange- 5’’dia.-18 Nos., M.S. bend 5’’ dia. – 4 Nos. each, Nut Bolt 20 kg. short piece 5″-2 Nos., cutting & welding of pipe where required with Rubber insertion, paint and cutting & welding charges etc. with all labour tools and materials. |
| 18 | Cost towards supply installation and testing of single stage centrifugal Backwash pump of Make- Mather & Platt/ Kirloskar /WPIL capable of discharging -9 lps. Head range-12 mtrs. to 19 mtrs., duty point head- 16 meters, Size of Pump-80x65 mm, Pump Eff.- 65%, coupled with suitable -3 phase, 2840 RPM, 50 Hz, TEFC sq. cage induction motor Make-Kirloskar/CG/ABB/Aqua mounted on a common M.S. channel fabricated base plate with following accessories-1. Suitable size N.R. Valve 01 No.2. Suitable size sluice valve 01 No.3. Suitable size Check valve/Foot Valve 01 No.4. M.S. Base Plate 01 No.etc. all complete. |
| 19 | Making of New PCC foundation 2.5’x2’x2’ size & M.S. joint 4″×6″-2 nos. with supplying all mortar materials & foundation bolts 6 Nos. with all labour tools and tackles loading unloading with alignment leveling and jointing as per P.W.D. Specification (1:2:4) etc. all complete. |
| 20 | Cost towards installation of above P/Set connecting suction 80 mm dia-45′, Delivery Pipe- 100 mm dia-10 ft. Flange 100 mm dia.- 9 Nos. each, M.S. bend 100mm dia. – 2 Nos. , reducer, Nut Bolt 20 kg. short piece 100 mm dia.- 6 Nos., Rubber insertion, paint, grease, gland packing and cutting & welding charges etc. with all labour tools and materials. |
| 21 | Supplying and laying of 6 sq. mm x 3 core X 1.1 KV grade with ISI mark PVC insulated and unarmoured flexible copper Cable from MCP to Backwash. motor terminal box with suitable copper lugs socket etc. work (for new backwash and priming mono block pump set) |
| 22 | Cost towards s/f of DOL starter suitable for operating of 3 h.p. backwash Pump Motor having relay range 7-10 Amp., working on 415 Volt,50 Hz. with relay contact, On-of Push buttons. Make-Havells/C&S/L&T make.( 5 H.P. DOL satarter) |
| 23 | Supplying and fitting of 415 volt, S-D-F FN 63A TPN main switch and SS enclosure suitable for DIN fuse link with HRC fuses make L&T/ Havell’s/ C&S with all labour & tools and materials installing at blower pump unit. |
| 24 | Raw water P/Plant –Intake Well at Rajpara |
| 25 | Providing all labours, tools, tackels and technician for disconnection and taking out 25 HP VT p/set with column pipe from intake well all complete set with additional arrangement of welding m/c, making of 1 set clamp etc. at p/plant. |
| 26 | Cost towards all labour, tools, tackles and technician for opening, dismantling, repairing and overhauling of 25 HP 04 stage bowl assembly VT pump having head 29 meter, discharge- 123 m3/hr. speed 1460 rpm. with changing of following accessories.i. C.I. retainer bearing (Spider bearing)- 05 Nos. as per sample.ii. Spider cut less rubber bushes- 05 Nos.iii. Locks.iv. 30mm dia. S.S. line shaft- 10 ft. each 3 Nos.v. 30mm dia. S.S. line shaft- 5 ft. each 2 Nos.vi. 30mm dia. S.S. head shaft- 5 ft. each 1 No.vii. S.S. shaft coupling (S.S Socket) -6 Nos. viii. 30 mm S.S. shaft & lever (S. S. Bush)-6 Nos.ix. S. Box –bush-01 No.x. S.S. Reducing Socket-01 No. xi. Impeller copper bush-10 Pcs. xii. G.M. impeller- 4 Nos. xiii. Ferro collar ball rubber bush- 8 Pc. xiv. Ball sleeve bush- 08 Nos. Changing Nut Bolts of Column pipe joints & VT pump bowl assembly with S.S. nut bolts -10 kg etc. as per sample all materials as per required reassembling the same at workshop, complete lathe work for line shaft threading, key & lock making and refitting etc. all complete job. (rate after deducting the scrap materials). |
| 27 | Providing all labours, tools, tackels and technician for lowering after repairing of 25 HP VT P/Set with column pipe, line shaft, Nut bolts etc. as per required into intake well all complete and testing on full load. |
| 28 | Cost towards transportation charges of above pump motor set and other fittings materials from p/plant to workshop and vice versa. |
| 29 | Cost towards repairing & servicing of motor control panel with FASD starter – 2 nos. and 200 Amp, 415 Volts MCCB -01 No., 100 Amp outgoing MCCB-02 Nos. with following works-i. Changing L&T MNX contactor –with L&T MNX contactor as Main contactor -MNX-70.ii. Star contactor MNX-50 and delta contactor MNX- 70 -01 No. each with Front & Side Add on Auxiliary contacts- (2NO+2NC) -04 nos. each iii. thermal overload Relay MN(45-70)-01 No,iv. MNX 50 A Contactor spare contact Kit-01 set v. MNX 50 A Contactor spare Coil 240 volt-02 Nos..vi. Timer (03-30 sec)-01 No. (L&T Make) vii. ON-OFF push buttons-02 Nos. viii. Digital Voltmeter (L1-L2-L3)-01 No..ix. Digital Ampere meter-01 No., x. Single phasing, reverse current, under voltage, over voltage protection relay-01 set each for both motor(MPD).xi. LED Phase indicating bulb-06 Nos., xii. Selector switch-01 No.xiii.16 mm2 single Core power cable grip to panel board-15 Mtrs., and 2.5 sq. Single core copper cable-35 mtrs. etc. with all fitting & electrician charges at P/Plant. |
| 30 | Supplying and fitting of 415 volt, S-D-F FN 250 A TPN main switch and SS enclosure suitable for DIN fuse link with HRC fuses make L&T/ Havel’s/ C&S with all labour & tools and materials installing at pump house. |
| 31 | Cost towards supplying and laying of 70 sq.mm x 3.5 core XLPE aluminium armoured 1.1 KV grade cable from meter to main switch to panel board in the pump house.(Confirms to IS:7098,PART-1) |
| 32 | S/F of 150 mm dia. Double flange sluice valve confirming for IS – 2906/14846 including worn gear arrangement as per test pressure stainless steel spindle should be fixed filter unit pipe line including all required size nut bolt rubber insertion and transportation charge etc. all complete. |
| 33 | S/F of 150 mm dia. double flange NR valve confirming for IS – 5312Part-1(1984) including worn gear arrangement as per test pressure stainless steel spindle should be fixed on delivery line of motor pump set including all required size nut bolt rubber insertion and transportation charge etc. all complete. |
| 34 | S/F of 90 watt LED Flood lighting luminaire with pressure die cast housing and toughened glass cover , operating voltage range 100V-270V AC with structure, stand, clamp, tee, wires and switches etc. all complete. |
| 35 | Cost towards supplying and fitting of lightening arrester suitable for 11 kv Line for protection of transformer in place of damaged lightening arrester with copper wire etc. all complete job. |
| 36 | Cost towards supplying and fitting of lightening arrester suitable for building protection with Earthling Electrode, Earthling Compound, copper wires and earth work etc. all complete job. |
| 37 | Add 18% GST |
| 38 | Add 1% Labour Cess Please Enable Macros to View BoQ information |