| 1 | Clear water Boosting P/Plant -W.T.P Campus at Jhajapara. |
| 2 | Cost towards repairing & servicing of motor control panel having FASD starter – 2 nos. and 200 Amp, 415 Volts MCCB -01 No., 100 Amp outgoing MCCB-02 Nos. with following works-i. Changing L&K MNX contactor –with L&K MNX contactor as Main contactor -MNX-70.ii. Star contactor MNX-50 and delta contactor MNX- 70 -01 No. each with Front (2NO+2NC) & Side (1NO+1NC) Add on Auxiliary contacts- 04 nos. each. iii. MNX 50 A Contactor spare contact Kit-01 set iv. MNX 50 A Contactor spare Coil 240 volt-02 Nos.v. Timer (03-30 sec)-01 No. (L&K Make)/ timer (30- 120 Sec.)-01No. GIC vi. ON-OFF push buttons-02 Nos. vii. 3 Ph LED Voltmeter CI 0.5-01 No.-01 No.viii. 3 Ph LED Ampere meter CI 0.5-01 No., ix. LED Phase indicating bulb-06 Nos., x. Auto/manual Selector switch-03 Nos.xi. MPD (Multi protection relay)-1 no. xii.16 mm2 single Core power cable grip to panel board-15 Mtrs., and 2.5 sq. Single core copper cable-35 mtrs. etc. with all fitting & electrician charges at P/Plant. |
| 3 | S/F of 90 watt LED Flood lighting luminaire with pressure die cast housing and toughened glass cover , operating voltage range 100V-270V AC with structure, stand, clamp, tee, wires and switches etc. all complete. |
| 4 | S/F of 90 watt LED street lighting luminaire with pressure die cast housing and toughened glass cover, operating voltage range 100V-270V AC with structure, stand, clamp, tee, wires and switches etc. all complete. |
| 5 | Cost towards painting of Electro-mechanical components as Motor Pump, Panel board, Sluice valve, NR Valves, Suction pipe line, common header pipe line inside Pump Chamber with primer and two coat of Metal Oil paint as required at WTP. |
| 6 | Supplying and fitting of 415 volt, S-D-F FN 250 A TPN main switch and SS enclosure suitable for DIN fuse link with HRC fuses make L&T/ Havel’s/ C&S with all labour & tools and materials installing at pump house. |
| 7 | Raw water P/Plant –Intake Well at Jhajapara |
| 8 | Providing all labours, tools, tackels and technician for disconnection and taking out 20 HP VT p/set with column pipe from intake well all complete set with additional arrangement of welding m/c, making of 1 set clamp etc. at p/plant. |
| 9 | Cost towards all labour, tools, tackles and technician for opening, dismantling, repairing and overhauling of 20 HP 04 stage bowl assembly VT pump having head 29 meter, discharge- 30 LPS speed 1460 rpm with changing of following accessories.i. C.I. retainer bearing (Spider bearing)-05 Nos. as per sample.ii. Spider cut less rubber bushes- 05 Nos.iii. Locks.iv. 30mm dia. S.S. line shaft- 10 ft. each 3 Nos.v. 30mm dia. S.S. line shaft- 5 ft. each 2 Nos.vi. 30mm dia. S.S. head shaft- 5 ft. each 1 No.vii. S.S. shaft coupling (S.S Socket) -6 Nos. viii. 30 mm S.S. shaft & lever (S. S. Bush)-6 Nos.ix. S. Box –bush-01 No.x. S.S. Reducing Socket-01 No. xi. Impeller copper bush-8 Pcs. xii. Ferro collar ball rubber bush- 4 Pc. xiii. Ball sleeve bush- 04 Nos. Changing Nut Bolts of Column pipe joints & VT pump bowl assembly with S.S. nut bolts -10 kg etc. as per sample all materials as per required reassembling the same at workshop, complete lathe work for line shaft threading, key & lock making and refitting etc. all complete job. (rate after deducting the scrap materials). |
| 10 | Providing all labours, tools, tackels and technician for lowering after repairing of 20 HP VT P/Set with column pipe, line shaft, Nut bolts etc. as per required into intake well all complete and testing on full load. |
| 11 | Cost towards transportation charges of above pump motor set and other fittings materials from p/plant to workshop and vice versa. |
| 12 | Cost towards repairing & servicing of motor control panel with FASD starter – 2 nos. and 160 Amp, 415 Volts MCCB -01 No., 100 Amp outgoing MCCB-02 Nos. with following works-i. Changing L&K MNX contactor –with L&T MNX contactor as Main contactor -MNX-50.ii. Star contactor MNX-40 and delta contactor MNX- 50 -01 No. each with Front & Side Add on Auxiliary contacts- (2NO+2NC) -04 nos. each.iii. Thermal overload Relay MN(45-70)-01 No.iv. MNX 50 A Contactor spare contact Kit-01 set.v. MNX 50 A Contactor spare Coil 240 volt-02 Nos.vi. Timer (03-30 sec)-01 No. (L&T Make).vii. ON-OFF push buttons-02 Nos.viii. Digital Voltmeter (L1-L2-L3)-01 No.ix. Digital Ampere meter-01 No.x. Single phasing, reverse current, under voltage, over voltage protection relay-01 set each for both motor (MPD).xi. LED Phase indicating bulb-06 Nos.xii. Selector switch-01 No.xiii. Bus bar as per sample- 3 nos.xiv. 16 mm2 single Core power cable grip to panel board-15 Mtrs., and 2.5 sq. Single core copper cable-35 mtrs. etc. with all fitting & electrician charges at P/Plant. |
| 13 | S/F of 90 watt LED Flood lighting luminaire with pressure die cast housing and toughened glass cover , operating voltage range 100V-270V AC with structure, stand, clamp, tee, wires and switches etc. all complete. |
| 14 | Cost towards painting of Electro-mechanical components as Motor Pump, Panel board, Sluice valve, NR Valves, Suction pipe line, common header pipe line inside Pump Chamber with primer and two coat of Metal Oil paint as required at Intake well. |
| 15 | Add 18% GST |
| 16 | Add 1% Labour Cess Please Enable Macros to View BoQ information |