| 1 | Shuttering for soffits of RCC Column,beams ,etc.,including strutting 3m high using mild steel sheets of size 90cmX 60cm X and B.G 10 stiffened with M.Sangles of size 25mm X 25mmX 3mm laid over silver Oak (C.W) joists of size 10cmX6.5cm (spaced at about 90cmc/c )and supported by casurina props of 10cmtol 3cmdia(spacedof 75cmC/C) © complying with standard specification and directed - 10 m 2 (P & D)Data 38 |
| 2 | Centering for soffits of RCC slabs of plane surface like lintels, beams etc. including strutting 3m high using mild steel sheets of size 90cmX 60cm X and B.G 10 stiffened with M.Sangles of size 25mm X 25mmX 3mm laid over silver Oak (C.W) joists of size 10cmX6.5cm (spaced at about 90cmc/c )and supported by casurina props of 10cmto13cmdia(spacedof 75cmC/C) complying with standard specification and directed - 10 m 2 (P & D)Data 38 |
| 3 | Reinforced Cement concrete 1:1.5:3 (one cement,one and half M.sand & three course aggregate) using 20mm gauge hand broken/and broken granite stone for all RCC items of works excluding centering shuttering and cost of reinforcement but including curingetc.,complete and also including fixing fan clamps and fixtures in rec works wherever necessary as directed by departmental officer etc., complete. |
| 4 | Supplying, fabricating and placing in position RTS rods for all RCC works including cost of steel and binding wire also in all floors complete complying with standard specification |
| 5 | FLY ASH BRICK WORK in cement mortar 1:5 (one cement and five sand) using best quality of second class (Table molded chamber burnt ) bricks of size 9\\"x4 44\\"x3\\" for the following including curing etc., complete complying with standard specifications. (Masonry projections wherever necessary for obtaining the required elevation shall be done without extra cost, |
| 6 | Plastering with cement mortar 1:5 (one cement and five sand by volume) 12mm thick for all internal/external surfaces like super structure, rainwater, ducts, elevation in all floors complying with standard specifications. |
| 7 | Special Ceiling Plastering and finishing all the RCC exposed surfaces such as RCC slabs, sunshades, canopies, staircase steps, landing slabs, etc. with cement mortar 1:3 (one cement and three sand) 10mm thick and including hacking the surfaces and providing necessary cement mortar nosing beading as per size, specification wherever necessary using the same mix as directed by the departmental officers etc complete complying with standard specification. |
| 8 | Paving the floor with design Antiskirt ceramic tiles (colour and shade as directed) of size 305mmx305mmx6mm in all floors over a base layer of cement mortar I:3(One part of Cement and Three part of Pfastering Sand(P Sand)),20mm thick laid in-situand pointed with samec oloured cementn. |
| 9 | Dadoomg walls with ceramic tiles of sizes 300mmX450mmX8mm size of approved make and quality and colour Set in cement mortar 1:2(One past of Cement and two part of Plastering Sand(P-Sand))over! 0mm base layer plastering and pointing with white cement neatly as directed, (SLNo.360f) |
| 10 | Weathering Course with Concrete Broken Brick Jelly 20 mm gauge inpure slaked lime (nos and to be added) over roof slab,the proportion of brick jelly to lime being '32 to 12.5 well beated with wooden beatcrs for giving required slope and thickness as directedby thedepart mental officers etc., complete.10 cum (SLNo.316) |
| 11 | Finishing the top of roof with one course of machine pressed tiles of size200mmx200mmx 20mmof approved quality in Cement Mortar1:3(One part of Cement and Three part of Plastering Sand (PSand)), 12 mm thick mixed with water proofing compound conforming to ISS at 2%by weight of cement used and the joints pointed neatly to full depth of tiles with the same cement mortar mixed withred oxide and water proofing compound including curing etc., complete |
| 12 | Supply and fixing of PVC Solid Doors using 19 gauge 19mmMSSoq,tubes for stylesand frames, 1SmmMS Sq.tubes for to, Lock and bottom rails. The Steel Tubes shall be coveredwith 5mm thick Solid PVC sheets.Shutter using 5mm thick solid PVC sheets for panelling shall rigidly fixed in position including furniture and fittings. Theoverall sizeof styles shall be 50mmX30mm.Theoverall sizeof toprail, Lock rail and bottom rail shall be75mmX30mm.Theover allsizeof framesshallbe50mmX45mm with suitable tabate for housing the shutter etc, completeas per standard specification. |
| 13 | Painting with First Quality Emulsion paint two coat including cleaning, scrapping, removal of dust and necessary plaster of paris putty works wherever required etc., complete. |
| 14 | Painting two coats over New iron works such as steel doors, windows, ventilators, window bars, balustrades etc., with best approved best quality of synthetic enamel paint of approved colour over the existing priming coat etc., complete complying with standard specifications and as directed by the departmental officers. |
| 15 | Wiring with 2x1.5sqmm (22 / 0.3 ) PVC insulated single core unsheathed copper conductor cable of 1100V grade in suitable heavy gauge MS conduit pipe on wall and ceiling with MS accessories with MS switch Box and SA F.T. switchwith painting of suitable colour continuous earth wire connection of 14 SWG TC wire for light pont / Fan point |
| 16 | Waring with 2 x1.5sqmm (22 / 0.3 ) PVC insulated single core unsheathed copper conductor cable of 1100V grade insuitable heavy gauge MS conduit pipeon wall and ceiling with M.S.accessories inflush with wall with 150mm x 100mmx 75mm MS switchbox with 3mm thick hylum sheet cover for 5A 3pin non interlocking CS plug with contmuous earthwire connection of 14SWG TC wire and making good of the concealed portion with suitable colour for concealed plug point. |
| 17 | Supply and fixing of single box type 4'40 W flu fitting complete with copper choke and condensor with TW round blocks on wall or ceiling with flu tube with PVC unsheathed Copper leads from terminals to the fitting. |
| 18 | Supply and run of 4x6 sq.mm (84/0.3) PVC insulated SC unsheathed Cu. Conductor of 1100V on 7/20 GI bearer wirefor service connection mains |
| 19 | Supply and run2x1.5sqmm (22/0.3)PVC insulated SC unshethed Cu.conductor of 1100V grade in 25mm dia GI pipe(Class ' B') suitably bent at both ends with necessary angle iron up right and end supports for mains. |
| 20 | Supplying and fixing of PVC Water Tank |
| 21 | Supplying and fixing in position Indian water closet of size 580X 440mm, white glazed earthen ware of approved quality with 'P’ trap or 'S' trap confirming to 1S:2556Part XIlwith sand cushion and forming flooringalround the close at using40mm broken brick jelly in lime concrete 1:2:5 (onepartof lime, twoparts of sand and five parts of brick jelly) 100mm thick and finishing the top to required slope and including 4 giving necessary connection to cast iron soil pipes/ PVCpipes by dismandling brickmasonry, reinforced cement concrete roof /floor slab and making good the disturbed portion to original condition without leahage etc., complete complying with standard specifications and as directed by the departmental officers. |
| 22 | Supplying and fixing in position best quality approved make white glazed earthenware wash hand basin of size 550X400mm with a pair of cast iron brackets, including cost of 15mm diametre brass chromium plated piller tape,32mmdiametreC.P.Waste union, 32mmdiametreP. V.C. waste pipe with rubber plug and chain,15mm dia metre G.M.wheel valve, 15mm dia brass nipple, 15mm dia nylon connections etc., including fixing thewash hand basin in thewall in position with apair of C.I. brackets with teakwood plugs and screws and giving necessary water supply connection and paintiung the brackets with two coats of paint over a primimg coat of anticorrosive paint including testing for leackage etc.,complete complying with standard specifications. |
| 23 | Supplying and fixing UPVC (Un-Plasticized Polyvinyl Chloride) Louvered Ventilators of from the profile the size of outer frame 60mmx58mm and shutter profile size of 60x78mm both profile sare reinforced with GI/Imm 125GSM and 100% corrosion free, the profile are multi chambered sections with wall thick of 2mm. The EPD Mrubber (black colour) covered with all over the edges of frame and shutter. The comers and joints should be welded and cleaned. Radiation spin headed glass 4mm thick should be provided in the louvers. The window should be fixed to the wall with 100% packing with screws and silicon packing all round the frames. The ventilator should be got approved from the Executive Engineer be foreuseon work |
| 24 | Supplying and fixing of ms angle truss and door including cost and all accessories etc complete |
| 25 | Supplying and fixing of materials |
| 26 | 63mm dia PVC pipe 6kg/cm2 |
| 27 | 90mm dia PVC pipe 6kg/cm2 |
| 28 | 90mm dia PVC Elbow |
| 29 | 90mm dia Tea |
| 30 | Manufacturing. Supplying and Fixing of Stainless Steel Hand rails for staircase using 50mm dia 304L Grade Stainless Steel pipe of 1.60mm thick at required locations to a height of 900mm from finished floor level welded to 38mm dia Stainless Steel pipe post of 1.00mm thick as vertical at 900mm centre with 2 Nos. of 25mm dia intermediate horizontal stainless steel pipe of 1.60mm thick in between. The vertical pipe has to be welded to the 100 X 100 X 6mm MS base plate encased in the base concrete. The rate is inclusive of the charges for cutting, bending, welding, grinding, polishing, conveyance, electrical charges, etc. complete |
| 31 | Paving the floor with Double charged Vitrified tiles of approved quality and colour of size 600x600x8mm thick of approved make, quality and colour in all floors over a base layer of cement mortar 1:3 (One part of Cement and Three part of Plastering Sand (PSand)), 20mm thick and laid straight alignment and pointed neatly with colour cement at the rate of 0.40kg/m2 laid without any air gap in the tiles neatly and fixing in position as per standard specifications and as directed by the departmental officer. The colour & quality of tiles should be got approved by Municipal Engineer before use on work |
| 32 | Provision for opening granite stone size of (0.60x1.05)using golden letters Please Enable Macros to View BoQ information |