Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Sch 'A' Part-I B/R work:-Demolition of brick work , built in cement mortar or cement lime mortar including all quions, arches, pillars, etc including demolition of precast rcc articles and disposal of debris out of MoD land complete all as specified and directed. |
| 2 | M&L for Brickwork with old size bricks, straight or curved on plan exc 6m mean radius, built in CM (1:6) complete all as specified and directed. |
| 3 | M&L for Brickwork with old size bricks, straight or curved on plan to any radius in half brick thick walls built in cement mortar 1:4 complete all as specified and directed. |
| 4 | Demolition of cement concrete or lime concrete (unreinforced) in ground floors and Pavings not exc 15 cm thick (below or above ground level ) and removing the debris outside from defence land complete all as specified and directed . |
| 5 | M&L for Cement concrete 1:3:6, type C-1 (using 20mm graded crushed stone aggregate) as in plinth protection and paving 75mm thick laid in slope finished even and fair including making joints at every 2.5 m and at corner filled with bitumen 85/25 and sand in ratio 1:2 by weight and complete all as specified. |
| 6 | M&L for 25mm thick Cement concrete in sub base for receiving floor tiles and mass concrete using Type B-1,1:2:4 (using 20 mm graded crushed stone aggregate) complete all as specified and directed.Note:- Finishing surfaces of concrete to be even and rough to receive the topping layer or floor tiles etc |
| 7 | Dismantling floor, hearth or wall tiling including cement mortar bedding ( but not backing) removing serviceable tiles to store and rubbish off the premises and removing the debris outside from defence land complete all as specified and directed . |
| 8 | Demolition stone slabs and tiles of any description or thickness in floors, approns etc and removing the debris outside from defence land complete all as specified and directed . |
| 9 | M&L for 20mm thick granite (pure black) work (table rubbed and polished) in steps, jambs pillars, window cills ,cooking platform and like including pointing in white cement (1:2) using marble dust with admixture of pigments to match with shade or granite over including 15mm thick screed bed or bedding layer in cement mortar 1:6 etc complete all as specified and directed.Note:- The stone slab shall be in one piece over kitchen plateform,window cill and making gas pipe holes 25mm dia with rounded holes and all open edges to be half rounded. |
| 10 | M&L for coloured Glazed ceramic tiles in vertical surface such as dado etc 450mmX 300mmX 7 to 8mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match the shade of the tiles over and including 10mm thick rough cement plaster to receive tiles in CM 1:4 complete all as specified and as directed. Note:-The texture ,colour ,Shade of tiles & laying of tiles to any pattern & any design with one or more colours shall be approved by GE and Rates also including in this item for necessary raking circular cutting or notching and waste on tiles. |
| 11 | S&F joint free non skid coloured Ceramic tiles 08mm to 10mm thick (square/ rectangular) polished, area of each tiles exceeding 0.11 Sqm but not exceeding 0.18 Sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15mm thick screed bed in CM 1:4 complete all as specified and directed.Note:-The texture ,colour ,Shade of tiles & laying of tiles to any pattern & any design with one or more colours shall be approved by GE and Rates also including in this item for necessary raking circular cutting or notching and waste on tiles. |
| 12 | S&F joint free non skid coloured Ceramic tiles 10 mm thick (square/ rectangular) polished, area of each tiles exceeding 0.18 Sqm but not exceeding 0.38 Sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15mm thick screed bed in CM 1:4 complete all as specified and directed.Note:-The texture ,colour ,Shade of tiles & laying of tiles to any pattern & any design with one or more colours shall be approved by GE and Rates also including in this item for necessary raking circular cutting or notching and waste on tiles. |
| 13 | Demolition of Roofs, floors (other than ground floors), beams staircases, landing, cooking platform ,chajjas, & similar suspended work cement concrete is reinforced (reinforcement cut as required to facilitate demolition) and disposal of debris out of MoD land complete all as specified and directed.Note:- Demolition will be done only by mechanical cutter only . |
| 14 | M&L for RCC type B-1 (1:2:4) using 20 mm graded crushed stone aggregate in Slabs supported on walls, beams and columns in floors, roofs, landings, blaconies, canopies, deck slabs and in shelves and the like such as cover slab of septic tank/soak well etc complete all as specified and as directed. Note:- Reinforcement shall be measured and paid separately). |
| 15 | Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings & similar work; not exc. 200mm thick (Horizontal or sloping) Rough finished surfaces of concrete flat complete all as specified and as directed |
| 16 | Formwork to edges of concrete flats, treads, window cills, concrete railing, floors & roof exc 5 cm but n. exc 10cm wide (Horizontal or sloping) Rough finished surfaces of concrete flat complete all as specified and as directed |
| 17 | M&L for Mild steel TMT bars 10mm dia & over,cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends & binding with & including mild steel wire (annealed) not less than 0.9mm dia or securing with clips quality complete all as specified and as directed. |
| 18 | M&L for cutting down plants / trees of girth not exc 15 cm & surface area not exc 0.36 Sqm each from roof tops /sides of external walls of buildings, chajja, wall junctions, junctions of of rain water / soil /waste vent pipes including taking out roots entered in wall/slab surfaces and making good the surfaces including repairing the CI/GI/PVC joints of affected locations by applying TUFALO (herbal medicine )and making good to suit the adjoining surfaces using PCC type 1:2:4, type B-O or cement mortar 1:2 complete all as per manufacturer instructions and as specified. NOTE: Any CI/GI/PVC pipes and fittings damaged during work shall be replaced by new one to insure leakage / seepage free joint without any extra cost to the department and Unit rate quoted by tenderer shall included for use of all scaffolding, trestles, ladders, cradles etc ,hoisting, lowering and protective measures etc up to four storeys height of bldgs and removing of debris out of MoD land complete all as specified and as directed. |
| 19 | Taking down chowkhats or frames exc 1.50 and n.exc 4 Sqm each (without talking off shutters from the freme) complete all as specified and directed. |
| 20 | Taking down chowkhat or frames with shutters (without taking off shutters from the frames) area not exc1.5 Sqm each and removing from site. |
| 21 | Taking down shutters of any description exc 1 sqm but not exc 2 sqm each and removing from site complete all as specified and directed. |
| 22 | Taking down shutters of any description exc 1 sqm and n exc 2 sqm and refixing in same opening after easing, adjusting and replacement of minor nails etc, complete all as specified and directed. |
| 23 | S&F pressed steel frames 105 x 60 x1.25 mm with one or more rebates including necessary fixing lugs/hold fast duly tarred with bitumen and sanding with sharp clean sand, hinges, lock strike plate including one shop coat of primer complete all as spd and directed |
| 24 | S&F pressed steel frames 165 x 60 x1.25 mm with one or more rebates including necessary fixing lugs/hold fast duly tarred with bitumen and sanding with sharp clean sand, hinges, lock strike plate including one shop coat of primer complete all as spd and directed |
| 25 | M&L for cement concrete type C-0, 1:3:6 using 12.5 mm graded crushed stone aggregate as in back filling of hollow portion of frame with plain cement concrete and for fixing of hold fast complete all as specified and directed. |
| 26 | S&F 30mm thick flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides, confirming to IS-2202 (part-1-1999), ISI marked complete all as specified and directed. |
| 27 | S&F 35mm thick factory made 2nd class hard wood Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain,chamfered or rounded. fitted with cut and mitred beads for securing glass,etc.; sizes of members of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to chowkats Note: wire cloth shall be measured separately |
| 28 | M&L for preparation of new wooden surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer all as specified. |
| 29 | S&F stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.18mm and fixed with stainless steel wire staples or using metal nut and bolts complete all as specified and directed. |
| 30 | S&F in repair stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples or using metal nut and bolts complete all as specified and directed. |
| 31 | Hacking out old broken glass ( any thickness, size, quality or description ) from wooden frames or stone concrete or brick surrounds, glazed with putty or fixed with beads complete. |
| 32 | S&F 3 mm thick sheet glass ordinary quality and glazing with oil putty wire clips in square n.exc 0.5 sqm in each pane upto tripple story building complete all as specified and directed. |
| 33 | S&F 3mm thick figured glass, pin head type and glazing with oil putty in square n-exc 0.5 sqm in each pane upto tripple story building complete all as specified and directed. |
| 34 | S&F solid PVC door frame of size50 x 47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube suppling fixing in opening as per specification & drawing complete all as specified & directed. |
| 35 | S&F factory made solid panel PVC door shutter 30mm thick (style) consisting of frame, made out of MS tubes for top and bottom rails MS frame shall be covered with heat moulded plain colour PVC , ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for to rail & bottom rail, paneling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the stiles & rails with suitable PVC sheet beading and jointed to getter with solvent cement, supplying & fixing in the frame at site as per specification & drawing for Item No. 08080 on page No 156 of SSR 2010 (Part-II). |
| 36 | S&F steel window/Ventilator factory made box type and shutter (double shutter) with sash bar made out of section using flash butt welding, hinges shall be provided to both shutters complete including all fittings including grills made out of 10 mm dia round bars glazing with 3 mm thick oridinary glass, guaging (wire mesh stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.18mm and fixed with stainless steel wire staples or using metal nut and bolts ) and two coat synthetic enamel paint over and including a coat of red oxide primer all as per drg No CEPZ/ TD/032/13 Sheet 1/2 including taking out old windows all as specified and directed. |
| 37 | M&L for repairing of Hinges in old steel windows for repairing or welding drilling out old bolts or set screws as required. including repairing for handle pegstag, wiremesh and glass change, painting one coat etc as servicable condition as per directed by Engr-in Charge. |
| 38 | M&L for repairing of Hinges in Old doors for repairing or welding drilling out old bolts or set screws as required. including repairing for handle, Hinges, wiremesh, and etc including painting one coat etc as servicable condition as per directed by Engr-in Charge. |
| 39 | S&F in reapirs for 18 to 20 mm thick PVC prelaminated solid board with one side decorative choice laminate and other side balancing white including 3mm thick lipping and equal to thickness of board as in kitchen cabinet, cupboard etc fixed with screws to steel/timber frame work including taking down old shutters of any description etc complete all as specified and directed. |
| 40 | S&F Ball catches with 8mm dia steel ball, and brass body and striking plate including letting in and fixed complete all as specified and directed. |
| 41 | S&F 40mm dia, cupboard knobs fixed with nut, screw and washer of brass, polished complete all as specified and directed |
| 42 | S&F hasp and staple, safety type, brass with mild steel hinge pin including bolt to hinge plate and fixed with screws, Size of hasp and staple in mm 100 complete all as specified and directed. |
| 43 | S&F Continuous (piano) hinges 30mm Width of flaps (when open) ,mild steel, bright finish or electrogalvanised complete all as specified and directed |
| 44 | S&F stainless steel butt hinges of size 100mm long etc complete all as specified and directed. |
| 45 | S&F Aluminium, anodised, barrel tower bolts of extruded section and fixed, Length of bolt in 150mm complete all as specified and directed |
| 46 | S&F Aluminium, anodised, barrel tower bolts of extruded section and fixed, Length of bolt in 200mm complete all as specified and directed |
| 47 | S&F Aluminium handles, cast type, anodised Size of handle in 150mm complete all as specified and directed. |
| 48 | S&F Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or castaluminium alloy and fixed Length of bolt in 250 mm complete all as specified. |
| 49 | S&F Floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring. Fixed in floor Overall length of cover plate 140mm complete all as specified and directed. |
| 50 | S&F 300mm, mild steel ordinary rat tail rod pattern springs including roller and roller plate including welding to steel frames.complete. |
| 51 | S&F in Repair stainless steel butt hinges of size 100mm long etc complete all as specified and directed. |
| 52 | S&F in Repair Aluminium, anodised, barrel tower bolts of extruded section and fixed, Length of bolt in 150mm complete all as specified and directed |
| 53 | S&F in Repair Aluminium, anodised, barrel tower bolts of extruded section and fixed, Length of bolt in 200mm complete all as specified and directed |
| 54 | S&F in Repair Aluminium handles, cast type, anodised Size of handle in 150mm complete all as specified and directed. |
| 55 | S&F Repair Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or castaluminium alloy and fixed Length of bolt in 250 mm complete all as specified. |
| 56 | S&F in Repair Floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring. Fixed in floor Overall length of cover plate 140mm complete all as specified and directed. |
| 57 | S&F in Repair 300mm, mild steel ordinary rat tail rod pattern springs including roller and roller plate including welding to steel frames.complete. |
| 58 | S&F in repair Door seal (Snake guard) with Aluminium frame powder coated up to 900 to 1000mm door opening complete all specified |
| 59 | S&F in repair 25mm outer dia stainless steel decorative drapery rod of thickness 20 gauge and for every 01 RM length, provide 10 numbers stainless steel rings with 50 mm dia and proportionate for part there off, with stainless steel brackets near to ends with stainless steel finish for 25mm dia drapery rod at both ends. The drapery rod shall be projecting 150 mm outer side from the clear opening of doors/windows. ( Including necessary fittings) |
| 60 | S&F peg set of 4, brass chromium plated, fancy type, superior quality and fixed with screws complete all as specified and directed. |
| 61 | Taking up or down 15mm bore, steel tubing and connection including cleaning for refixing or removal from site complete all as specified and directed. |
| 62 | S&F 15mm bore Steel water tubing 'medium grade', galvanised with all fittings like elbow, tee, socket, bend etc and fixed to wall, ceiling or laid in floor complete all as specified and directed. |
| 63 | Fixing only 15mm bore old Steel water tubing including all new galvanized fittings like elbow, tee, socket, bend etc and fixed to wall, ceiling or laid in floor complete all as specified and directed. Note: - Old Steel water tube/pipe any type retrieved from taking down shall be used along with all new GI fittings) |
| 64 | Taking up or down 20mm bore, steel tubing and connection including cleaning for refixing or removal from site complete all as specified and directed. |
| 65 | S&F 20mm bore Steel water tubing 'medium grade', galvanised with all fittings like elbow, tee, socket, bend etc and fixed to wall, ceiling or laid in floor complete all as specified and directed. |
| 66 | Fixing only 20mm bore old Steel water tubing including all new galvanized fittings like elbow, tee, socket, bend etc and fixed to wall, ceiling or laid in floor complete all as specified and directed. Note: - Old Steel water tube/pipe any type retrieved from taking down shall be used along with all new GI fittings) |
| 67 | Cutting chases in brick walls, pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, shelves, lintels, etc, and cutting chases for concealed water tubing or conduit wiring, etc and making good, cutting not exceeding 10cm girth complete all as specified and directed |
| 68 | S&F in repair Gun-metal, globe or gate valves 15mm bore, with iron wheel head, screwed both end for iron pipe |
| 69 | S&F in repair Gun-metal, globe or gate valves 20mm bore, with iron wheel head, screwed both end for iron pipe |
| 70 | S&F Rotational moulded polyethlene water storage tanks three layers white in colour of 500 ltrs capacity ISI marked (cylindrical vergical with closed top) hoisted and fixed in position all as specified in SSR Part I including 20mm thick Ball valves high pressure of PTMT with epoxy coated Aluminium rod & high-density plastic bal screwed for iron pipe and fixed. (Minimum weight 20mm-210 gms including Dismantling of old brocken water tanks and refixing of inlet, outlet & over flow pipe etc complete all as specified and as directed. |
| 71 | S&F Rotational moulded polyethlene water storage tanks three layers white in colour of 1000 ltrs capacity ISI marked (cylindrical vergical with closed top) hoisted and fixed in position all as specified in SSR Part I including Ball valves high pressure of PTMT with epoxy coated Aluminium rod & high-density plastic bal screwed for iron pipe and fixed. (Minimum weight 20mm-210 gms including Dismantling of old brocken water tanks and refixing of inlet, outlet & over flow pipe etc complete all as specified and as directed. |
| 72 | Cleaning and removing all scale and dirt, etc, from capacity in exc 250 not exc 500 litres tanks any size and from mouths of circulating pipes, etc. and replacing and fixing broken covers complete all as specified and directedNote: While cleaning Float valve to be removed and refixed as and where is fixed incase of damage it is to be changed with no extra cost to the Govt. |
| 73 | All as per sel item No. 73 here-in-before but capacity exc 500 but n. exc 1000 litres tanks |
| 74 | S&F in repair Ball valves 20mm bore high pressure of PTMT with epoxy coated Aluminium rod & high-density plastic bal screwed for iron pipe & fixed. (min. weight 20mm-210 gms) |
| 75 | S&F in repair PVC tank lid/cover for water storage tank of 500 ltrs capacity with fixing arrangement complete all as specified and directed. |
| 76 | S&F in repair 15 mm bore long body CP Bib taps cast copper alloy fancy type with capstan heads (chromium plated),and cup screwed down , high pressure for iron pipe complete all as spd & directed. |
| 77 | S&F in repair two way bib cock/angle cock 15 mm bore fancy type chromium plated, with capstan head, high pressure, screwed down, screwed for iron pipe or for brass ferrule fixed to iron pipe. |
| 78 | S&F in repair hand shower dia 105 mm round shape single flow with air effect (ABS BODY & FACE PLATE CHROME PLATED) with rubit cleaning system including shower flexible tubes 8 mm dia & 1.5 m long with nuts complete all as specified and directed by Engr-in-Charge. |
| 79 | S&F in repair health faucet (ABS Body) mild steel chromium plated suitable for 15mm dia pipe with 1.25 meter long flexible tube and ABS wall 1.25 m long flexible tube and ABS wall hook including making connection and fixed in position complete all as spd |
| 80 | S&F in repair stainleess steel towel rack 600 MM long with lower hanger, fancy type, superior quality, fixed with and including chromium plated screws and wooden/plastic cleats complete all as specified and directed by Engr-in-Charge. Make : ACN-CHR-1181S of JAQUAR or equivalent in ESS ESS, Players. |
| 81 | S&F in repair stop cock/angle valve cast copper alloy screwed down high pressure ,with crutch or butterfly handle screwed both ends for iron pipe or for union of 15 mm bore complete all as specified & directed Make: Parryware,Jaquar,Prayag |
| 82 | S&F in repair stop valves (ISI marked), 15mm dia, cast copper alloy,chromium plated fancy type with long shank and cup(concealed type) screwd down,high pressure with crutch or butter fly handle,screwed both ends for iron pipes or for unions and fixed in pipe all as specified and directed. |
| 83 | S&F in repair 15mm dia Bib tap standard of PTMT any colour high pressure screwed for iron pipe and fixed. (Minimum weight 15mm-90gms/20mm- 125gms). |
| 84 | S&F in Repair 15mm dia Pillar taps of PTMT any colour high pressure screwed for iron pipe and fixed.(Minimum weight 15mm-110gms |
| 85 | S&F in Repair 15mm dia Stop valve of PTMT any colour high pressure screwed for iron pipe and fixed. (Minimum weight 15mm-90gms/ 20mm-92gms) |
| 86 | S&F in Repair Swan neck CP Pillar taps fancy type 15 mm bore, cast copper alloy, with capstan heads screwed down high pressure, with or without lettered `Hot' or `Cold' with long screwed shankS&Fly-nuts, screwed for iron pipe complete all as specified and directed. |
| 87 | S&F in Repair Brass CP shower rose 125mm size including fixing to steel pipe or union complete all as specified and directed. |
| 88 | S&F in Repair Tubular towel rail, ISI marked 60cm long between flanges , 20mm dia 'D' type Brass Chromium plated incl brackets, fixed with chromium plated brass screws and wooden/plastic cleats complete all as specified and directed. |
| 89 | S&F in repair towel Ring round with round flange of brass chromium plated including brackets. complete all as specified and as directed.Make:Cera or equivalent. |
| 90 | S&F in repair 5mm thick looking mirror of size 600x450mm of selected quality glass mounted on 6mm thick AC building board or commercial plywood and aluminium angle beading around mirrior fixed on wall PVC plug and screws etc complete all as specified and directed |
| 91 | S&F in repair 600mmx450mm mirror cabinet of selected quality glass, mounted on PVC Shutter of the cabinet and fixed cup washers complete all as specified and directed. |
| 92 | S&F in Repair Sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with CP bracket guard & railing 60cm long fixed with chromium plated brass screws and wooden/plastic cleats complete all as specified and directed. |
| 93 | S&F in repair Vitreous China wash down water closet pan including P or S trap of bore 125/110 mm (pedestal pattern), white or in matching colour of tiles (excluding flushing cistern and flush pipe) including plastic water closet seat, white or in matching colour , closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device and wash down water closet complete all as specified and as directed. |
| 94 | S&F in repair internal fitting (complete Kit) of low level cistern (capacity 10 ltr) such as PVC handle, PVC washer, float valve with ball & rod, syphon, piston etc complete all as specified. |
| 95 | S&F in repair plastic water closet seat cover, Cream / white colour, closed pattern with flat bottom and cover and mild steel chromium plated aluminium hinging device for pedestral pattern WC. |
| 96 | S&F in repair viterous China squatting pan, `Orrisa' pattern, size 580 x440 mm white, witht integral foot rests (excluding flushing cistern and flush pipe) including connection to trap,and to flushing pipe, anti-syphonage pipe,etc. complete including making good to floor complete all as specified and as directed. |
| 97 | S&F in Repair 10 ltrs capacity PVC valveless, syphonic action type, flushing cistern, low level, white, with intel, ball valve, float and handle including brackets ,fush pipe of polyethylene of low or high density or PVC 32 mm dia complete all as specfied and as directed. |
| 98 | S&F in Repair Viterous China wash basin, white, flat back, size 550x400mm excluding taps etc but including brackets,including cutting for and pinning in ends of brackets or erecting stand but exclusive of fixing of supply and waste pipe complete all as specfied and as directed. |
| 99 | S&F in repair sink with drainage board made of stainless steel 1 mm thick with plugs, washers and wastes, including bedding in cement mortar to dwarf wall or including fixing cantilever brackets of angle iron and connecting union to pipe over all size 915 mm x460 mm and bowl size 410mmx330mmx 160mm complete all as specified and directed. |
| 100 | S&F in repair Stainless steel plate in repair rack (Utensil Rack) of size (900mm x 750mmx250mm ) made out of AISl 304 stainless steel 0.63 mm thick sheet fixed with brass screw of required size including necessary fittings/nuts,bolts & washers complete all as specified and as directed. |
| 101 | S&F in repair 15mm dia 600 mm long PVC connection including brass check nut at both ends screwed both end for iron pipes. |
| 102 | S&F in repair 32/40 mm bore PVC waste down take pipe 900 to 1000mm for WHB, sink etc complete. |
| 103 | S&F in repair 32mm dia Waste coupling, brass , chromium plated for basins etc. with long screwed shanks and fly -nuts , flange end bedded in red lead cement and other end fixed |
| 104 | S&F in repair 40mm dia Waste coupling, brass , chromium plated for sink etc. with long screwed shanks and fly -nuts , flange end bedded in red lead cement and other end fixed |
| 105 | Demolition and breaking up drain pipes (Salt glazed ware, PVC/AC or Reinforced concrete) set in cement mortar,and taking out of trenches, if required, Internal dia of pipe in 75MM/100mm |
| 106 | S&F PVC (SWR) pipes 75mm bore single socketed, in any length with rubber ring joints laid in trenches or in floors all as specified and directed. |
| 107 | S&F PVC (SWR) pipes 110mm bore single socketed, in any length with rubber ring joints laid in trenches or in floors all as specified and directed. |
| 108 | Taking down eaves gutter and rain water pipe any size any pattern , PVC/ AC pipe including all fittings ,heads shoes, bends etc including removal to store ,Internal dia of pipe in 75MM/110mm complete all as specified and directed.all as specified and directed. |
| 109 | S&F PVC (SWR) pipes 75mm bore single socketed in any length with rubber ring joints fixed to walls all as specified and directed. |
| 110 | S&F PVC (SWR) pipes 110mm bore single socketed in any length with rubber ring joints fixed to walls all as specified and directed.(ISI MARKED) |
| 111 | S&F PVC (SWR) bends any radius 75mm dia all as specified and directed.(ISI MARKED) |
| 112 | S&F PVC (SWR) bends with accessible door any radius 75mm dia all as specified and directed.(ISI MARKED) |
| 113 | S&F PVC (SWR) bends any radius 110mm dia all as specified and directed.(ISI MARKED) |
| 114 | S&F PVC (SWR) bends with accessible door any radius 110mm dia all as specified and directed.(ISI MARKED) |
| 115 | S&F in Repair 75mm PVC floor trap, ISI marked with cp grating with/without waste pipe hole incl jointing to waste pipe fixed with solvent cement complete all as specified and as directed. |
| 116 | S&F in Repair 125 mm stainless steel grating fixed with white cement complete all as specified and as directed. |
| 117 | Dismanting of Asbestos cement (corrugated, semi corrugated , etc) sheets in roof coverings etc complete all as specified and as directed. |
| 118 | S&F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed. |
| 119 | Dismantling timber scantling 40 Sq cm and over in section, in any position framed work. |
| 120 | M&L for framed work in rolled sections as in joist, channel, angle or tee section; square or round hollow section in rafters, purlins of Fe-290-W(Gde-E-165) complete all as specified and directed. |
| 121 | M&L for 75mm thick plain cement concrete 1:4:8, type D-2 using 40mm graded crushed stone aggregate as in sub base complete all as specified and as directed. Note:- Finishing surfaces of concrete to be even and rough to receive the topping layer. |
| 122 | M&L for non abrasive paving (endura) tiles 300mm x 300mm x10mm thick (square/ rectangular) polished, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement over & including 15mm screed bed CM 1:4 to match complete al as specified and directed.Note:-The texture ,colour ,Shade of tiles & laying of tiles to any pattern & any design with one or more colours shall be approved by GE and Rates also including in this item for necessary raking circular cutting or notching and waste on tiles |
| 123 | M&L for Coloured (glossy) machine pressed precast concrete interlocking paver block any shape & size confirming to IS 15658-2006 of 60 mm thickness, M-40 grade rubber moulded glossy finish with grey cement and pigment complete all as secified and as directed.Note-Shapes of interlocking paver block shall be triangular/Zigzag/Haxagon/or other ,Colour of paver blocks & laying pattern approved by GE. |
| 124 | M&L for sand filling under floors or in foundations including watering and consolidation or layer of sand cushioning below interlocking paver block complete all as specified and as directed. |
| 125 | M&L for 100 mm thick plain cement concrete type B-1 , 1:2:4 (using 20 mm graded crushed stone aggregate) finished even and smooth without using extra cement as in flooring complete all as specified and directed.Note- Glass dividing strips shall be measured & paid separately as supply only. |
| 126 | Supplied only 38 mm wide and 3 mm thick glass dividing strips in flooring by fixing in position and making square or rectagle for casting concrete in flooring. |
| 127 | Taking down cement plaster of any description and thickness on walls/ceilings etc including racking out joints, hacking for key, scrubbing down with water etc including necessary scaffolding up to four storeys height of bldgs if required and removing of debris out of MoD land complete all as specified and as directed. |
| 128 | M&L for rendering 15mm thick on other than fair faces of brick work or concrete surface of wall in CM 1:4 finished surface even and smooth without using extra cement complete all as specified and as directed. |
| 129 | M&L for rendering 15 mm thick on fair faces of brick work or concrete surfaces of wall in cm 1:6 finishing surfaces even and smooth without using extra cement complete all as specified and as directed. |
| 130 | M&L for Rendering 5mm thick on fair faces of brick work or concrete surfaces in CM (1:3) as on ceiling complete all as specified and as directed. |
| 131 | M&L for preparation of newly plastered surfaces of ceiling and applying three coats of white wash complete all as specified and as directed. |
| 132 | M&L for preparation of old surfaces of ceiling and applying one coats of white wash complete all as specified and as directed. |
| 133 | M&L for preparation of newly plastered internally surfaces of wall by scrapping with mechanical wall sander , having RPM not less then 1500 and applying min 1.00 mm thick wall care putty on the surfaces & making the surface absolutely smooth surface and applying one coat of primer (as per manufacturer’s recommendations) on the surfaces and applying two coats of distemper oil emulsion finished without any brush marks on the surface in any colour including necessary scaffolding up to four storeys height of bldgs if required ,Shade/colour shall be approved by GE,all painted areas site to be cleaned and hand over as earlier without any extra cost to Govt complete all as specified and as directed. |
| 134 | M&L for preparing internally old surface of wall by washing, rubbing & scrapping with mechanical wall sander , having RPM not less then 1500 and applying min 1.00 mm thick wall care putty on the surfaces and making surface absolutely smooth and applying one coat of primer (as per manufacturer’s recommendations) on the surfaces and applying two coats of distemper oil emulsion without any brush marks on the surface in any tint including necessary scaffolding up to four storeys height of bldgs if required ,Shade/colour shall be approved by GE,complete all as specified and as directed. |
| 135 | M&L for preparation of old surface of wall with mechanical wall sander and applying one coats of distemper oil emulsion without any brush marks on the surface in any tint including necessary scaffolding up to four storeys height of bldgs if required ,Shade/colour shall be approved by GE,all painted areas site to be cleaned and hand over as earlier without any extra cost to Govt complete all as specified and as directed. |
| 136 | M&L for preparation of newly plastered external surfaces of wall by scrapping with mechanical wall sander , having RPM not less then 1500 and applying Two or more coats of water based premium acrylic smooth exterior paint (weather proof/weather coat: APEX ULTIMA) having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade with silicon additives @ 1.79 litre(undiluted)/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm (weather proof/weather coat) over and including water proof cement based 1.5mm thick wall care putty without any brush marks on the surface in any colour over including necessary scaffolding up to three storeys height of bldgs,Shade/colour shall be approved by GE, complete all as specified and as directed. |
| 137 | M&L for complete removal of existing treatment externally surface of wall by scrapping with mechanical wall sander , having RPM not less then 1500 and applying Two or more coats of water based premium acrylic smooth exterior paint (weather proof/weather coat: APEX ULTIMA) having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade with silicon additives @ 1.79 litre(undiluted)/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm (weather proof/weather coat) over and including water proof cement based 1.5mm thick wall care putty without any brush marks on the surface in any colour over including necessary scaffolding up to three storeys height of bldgs,Shade/colour shall be approved by GE, complete all as specified and as directed. |
| 138 | M& L for preparing old plaster or unplastered wall surfaces including cornices, pillasters by brooming down with steel wire brushing scrapping down smoke soot, moulds and effloresent salts and treating oily and greasy spots etc and applying one coat of Premium water proof cement base paint for external services without any brush marks on the surfaces complete all as specified and directed. |
| 139 | M&L for preparation of old wooden surfaces of any description over 10 cm width or girth and applying one coat of synthetic enamel paint all as specified. |
| 140 | M&L for preparation of old painted steel and iron surfaces of any description over 10 centimeter width or girth and applying one coat of synthetic enamel paint in any colour finished without brush mark on surface including necessary scaffolding up to four storeys height of bldgs if required,Shade/colour shall be approved by GE,all painted areas site to be cleaned and hand over as earlier without any extra cost to Govt complete all as specified and as directed. |
| 141 | M&L for preparation of new steel surfaces of any description over 10 cm width or girth and applying two coats of synthetic enameled paint over a coat of red oxide primer all as specified and directed. |
| 142 | M&L for writing letters or figures (Block, Roman or Indian) not exc 30 cm high for bldg no/direction board with synthetic enamel paint in black colour or any other colour complete all as specified and as directed. |
| 143 | M&L for replacement of GI socket 15mm bore medium grade ISI marked complete all as specified and directed.Note: Cost of taking down GI tubing for replacement of worn out/defective GI fitting & refixing there after shall be deemed to be included in the rates quoted by the contractor |
| 144 | All as per Srl item No. 143 here-in-before but GI elbow 15 mm dia. |
| 145 | All as per Srl item No. 143 here-in-before but GI nipple 15 x 50mm |
| 146 | All as per Srl item No. 143 here-in-before but GI nipple 15 x 75mm |
| 147 | All as per Srl item No. 143 here-in-before but GI union coupling 15 mm dia |
| 148 | All as per Srl item No. 143 here-in-before but GI tee 15 mm dia. |
| 149 | M&L for replacement of GI socket 20mm dia medium grade ISI mark complete all as specified and directedNote: Cost of taking down GI tubing for replacement of worn out/defective GI fitting & refixing there after shall be deemed to be included in the rates quoted by the contractor |
| 150 | All as per Srl item No. 149 here-in-before but GI elbow 20 mm dia. |
| 151 | All as per Srl item No. 149 here-in-before but GI nipple 20 x 50mm |
| 152 | All as per Srl item No. 149 here-in-before but GI nipple 20 x 100mm |
| 153 | All as per Srl item No. 149 here-in-before but GI union coupling 20 mm dia. |
| 154 | All as per Srl item No. 149 here-in-before but GI nipple 20 mm dia for tank. |
| 155 | All as per Srl item No. 149 here-in-before but GI tee 20 mm dia. |
| 156 | S&F in Repair of rubber washer for stop cock, bib tap, Pillar tap ,gate valve of any type all as specified and directed |
| 157 | S&F in Repair brass spindle/disc suitable for cp piller tap, cp bib tap, cp stop cock, cp angle cock all as specified and directed |
| 158 | All as per sel item No 157 here-in-before but for concealed type stop cock |
| 159 | Sch 'A' Part-I E/M Work:-M&L for point wiring in repair for light / fan controlled by one switch with 1.50 sqmm PVC insulated unsheathed multistrand copper conductor FRLS-H cable in existing PVC concealed conduit terminated in new anodise pressed steel sunken box of approved thickness with ISI marked bakelite laminated sheet fixed with cadmium plated screws and washers for switches and sockets, including 1.5 sqmm PVC insulated unsheathed multistrand copper conductor FRLS-H as earth continuity conductor connected to common earth dolly including, cutting chiseling for concealed boxes, including insulation test of point wiring and making good disturbed surface area and white wash/colour wash to matching with the existing colour including taking down of old existing wiring any type and all as specified .Note: colour coding is to be maintained .(Ph-Red, N-Black, Half -Yellow, Earth- Green). |
| 160 | All as per Srl item No 159 here-in-before but for call Bell point complete all as specified and directed . |
| 161 | All as per Srl item No 159 here-in-befor but for 5 pin 5 amps socket outlet or independent board complete all as specified and directed. |
| 162 | All as per Srl item No 159 here-in-befor but for 3 pin 5 amps socket outlet on the same board with other switch complete all as specified and directed. |
| 163 | M&L for point wiring in repair with 2.5 sqmm PVC insulated unsheathed multistrand copper conductor FRLS-H cable in existing PVC concealed conduit terminated in new anodised pressed steel sunken box approved thickness with ISI marked bakelite laminated sheet fixed with cadmium plated screws and washers for switches and sockets, including 2.5 sqmm PVC insulated unsheathed multistrand copper conductor FRLS-H as earth continuity conductor connected to common earth dolly including, cutting chiseling for concealed piping ,including insulation test of point wiring and making good disturbed surface area and white wash/colour wash to matching with the existing colour including taking down of old existing wiring any type and all as specified .Note: colour coding is to be maintained .(Ph-Red, N-Black, Half -Yellow, Earth- Green). |
| 164 | S&F in replacement switch piano flush type one way 5 amps SP 240 volts complete all as specified and directed. |
| 165 | S&F in replacement switch piano flush type one way 15 amps SP 240 volts complete all as specified and directed. |
| 166 | S&F in replacement socket outlet 2 in 1, 3 pin 5 amps flush type 240 volts complete all as specified and directed. |
| 167 | S&F socket outlet 2 in 1, 5 pin, 5 and 15 amps flush type 230 volts complete all as specified and directed. |
| 168 | S&F in replacement switch Bell push, flush type, 5 amp one way complete all as specified and directed by Engr-in-charge. |
| 169 | S&F in replacement ceiling fan regulator electronic socket type 5 stage speed variation ISI marked complete all as specified and directed. |
| 170 | S&F in replacement lamp holder/batton holder/angle holder insulated body with bakelite back plate suitable for fittings complete all as specified and directed. |
| 171 | S&F in replacement of Bell Ding Dong, AC 230 Volts single Phase complete all as specified and directed by Engr-in-charge. |
| 172 | S&F in replacement ceiling rose 65 x 50mm three terminals complete all as specified and directed. |
| 173 | S&F in replacement sleek LED mirror light fitting 2 feet long 1x10 W including LED tube 2 feet long of same make having ballast , bipin holder, connector block etc. complete with all accessories prewired and connecting electrically to ceiling rose using PVC insulated and overall sheathed flexible copper conductor cable of suitable size complete all as required at site or directed. |
| 174 | S&F in replacement of LED Lamp, B22 type ,12 watt,complete all as specified and directed. |
| 175 | S&F in replacement energy saving decorative LED 20W box type (4 Feet), frame , light fitting extruded aluminium housing provided for efficient heat dissipation with polycarbonate diffuser & integrated electronic driver complete with all accessories prewired without tube and making connections with 3 core twisted flexible copper cable of suitable size from ceilling rose/PVC connector to light fittings complete all as spd and directed by Engr -in -charge. |
| 176 | S&F in replacement LED Bulkhead fitting 10 watt all as specified and directed by Engr-in-charge. |
| 177 | S&F in replacement LED decorative wall light fixturemade up of polycorbonate, suitable for retro fit LED Lamp alongwith 12W LED lamp complete all as specified and as directed. |
| 178 | S&F in replacement 20mm Rigid non-metallic PVC conduit heavy duty exclusive of boxes (junction/terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc complete all as specified and directed. |
| 179 | S&F in replacement of existing unsv sheet metal enclosure with sheet metal enclosure MCB distribution board single pole and neutral with a two pin and earth plug and socket 20 amps 240 volts, complete with one single pole MCB of 20 amps 'C' curve complete all as specified and directed . |
| 180 | S&F in replacement of sheet metal enclosure MCB distribution board, double door with IP-43 protection single phase 240 volts 8 way, including suitable size copper bus bar and neutral link fixed flush in wall including chases in wall for fixing DB and making good the distributed wall surfaces to match with existing specification complete all as specified and directed. |
| 181 | M&L in replacement for MCB SP 240 volts any rating from 6 to 40 amps, 'C' cruve with rupturing capacity 10 KA, including providing thimble for out going cables complete all as specified and directed. |
| 182 | M&L in replacement for MCB SPN 240 volts any rating from 6 to 40 amps, 'C' cruve with rupturing capacity 10 KA, including providing thimble for out going cables complete all as specified and directed. |
| 183 | S&F in replacement sub Main Wiring with two PVC insulated unsheathed multistrand FRLS flexible copper conductor cable of size 2x6 sqmm and one PVC insulated multistrand unsheathed FRLS flexible copper conductor cable of size 6 sqmm (green colour) as earthing lead connecting to main earthing dolly drawn in and including non metallic PVC concealed conduit 20mm dia complete and making good to disturbed surface complete of wall/floor with cement mortar and finishes to match the existing surface complete all as specified and directed. |
| 184 | S&F in replacement bldg secuirty light fitting energy saving high efficiency LED street light fitting 35 Watts, 5700 K, IP 66, having pressure die cast housing with toughened glass and individual high power LEDs with secondary optics, prismatic polycarbonate cover complete including GI bracket of size 25 mm dia bent to shape having length on less than 0.9 mtr fixing with clamp etc and making connections using cord flexible 3 core copper cable of size 23/ .0076 from ceilling rose/ PVC connector to light fittings or as directed by Engr-in-chrage. |
| 185 | Maintenance of storage type electric water heater capacity 25/50 Ltrs comprising of the following activities : -(a) Taking down by disconnecting electric and water connection and making visual inspection opening and dismantling, de-scaling, brushing and cleaning of storage tank of any type and checking of each item for its servicieability and reasssemebed the same after necessary repair and testing complete all as specified and directed.(b) Checking the earth continuity of gysers water heater and accessories, complete all as specified and directed.(c) Visual examination of fusible plug, complete all as specified and directed. |
| 186 | S&F in replacement PVC flexible copper cable sheathed 3 core, 2.5Sqmm, universal colour code, complete all as specified and directed by Engineer-in-charge. |
| 187 | S&F in replacement heating element 2.0 KW & testing of electric connections as per site requirement, complete all as specified and directed. |
| 188 | S&F in replacement thermostate of 25/50 Ltrs capapcity, 250Volts,AC and testing complete all as specified and directed. |
| 189 | S&F in replacement PVC connection of size 15mm dia and 450mm long superior quality for Geyser, complete with brass adopted for Geyser hot/cold, complete all as specified and directed. |
| 190 | S&F in replacement metalclad plug top 20Amps,complete all as specified and directed. |
| 191 | S&F in replacement Plug top 15Amps,complete all as specified and directed. |
| 192 | S&F in replacement syphon assembly complete for 25 Ltrs capacity Geyser as exisiting on ground complete all as specified and directed. |
| 193 | S&F in replacement indicator lamps to Geyser of any make type & capacity complete all as specified and directed. |
| 194 | S&F in replacement inner tank of Geyser of capacity 25Ltrs of suitable size as per site requirement, make of steel as per exisitng gauge, complete all as specified and directed. |
| 195 | S&F in repair pressure release valve of geyser (ISI marked) of 15mm dia with rubber washer as per site requirement, complete all as specified and directed. |
| 196 | S&F in replacement Gang Box for 15 Amp Switch socket combined including 15Amp combiation complete all as specified and directed by Engr-in-charge. |
| 197 | S&F in replacement Gang Box for 5 Amp Switch socket combined including 5Amp combiation complete all as specified and directed by Engr-in-charge. |
| 198 | S&F in replacement Hylum sheet 4x4 to 4x6 inches for fixing of switchs sockets including cutting for switch socket and fixing to existing sunken box with brass screw complete all as specified and directed by Engr-in-charge |
| 199 | S&F in replacement Hylum sheet 6x10 to 8x10 inches for fixing of switchs sockets including cutting for switch socket and fixing to existing sunken box with brass screw complete all as specified and directed by Engr-in-charge |
| 200 | S&F in replacement sunken box of 4x4 to 4x6 inches for fixing of hylum sheet including cutting for switch socket and fixing to existing sunken box with brass screw complete all as specified and as directed by Engg-in-charge. |
| 201 | S&F in replacement sunken box of 6x10 to 8x10 inches for fixing of hylum sheet including cutting for switch socket and fixing to existing sunken box with brass screw complete all as specified and as directed by Engg-in-charge. |
| 202 | S&F in replacement switch socket combination 2 in 1, 3 pin, 6 and 16 amps flush type 230 volts complete all as specified and as directed by Engg-in-charge. |
| 203 | S&F in replacement switch socket combination 2 in 1, 3 pin, 6 amps flush type 230 volts complete all as specified and as directed by Engg-in-charge. |
| 204 | Taking down carefully 1200/1400mm sweep ceiling fan any make from the hook of OTM/MD Accn carrying to the wksp including rehanging the same at existing position after cleaning, greasing and connecting up with PVC insulated copper flexible wire 3 x single core 1.0 Sqmm from ceiling rose to connector of fan complete all as specified and directed by Engr-in-Charge .NOTE :-1. PVC copper flexible wire 1.0 Sqmm single core( 3 runs each) shall be measured and paid separately under relevant item. 2. Total service time from taking down to rehanging must not exceed 3 Days .3. T&P such as ladder and vechicle will be provided by contractor at their own expense . |
| 205 | Strip opening of ceiling fan 1200mm sweep and carrying out rewinding with proper grade/guage super enamelled copper winding wire so as to achieve original specifications i.e current rating and RPM (RPM test of ceiling fan with suitable tachometer will be done by contractor and shown to deptt , tachometer will be provided by contractor at their own expense) and all insulating materials (spares will be used and measure in respective items) and reasembling etc complete all as specified and directed by Engr-in-Charge. Note :- 1.Under liability period ,in case winding or any accessory i.e capacitor, becomes non functional, it will be repaired without any extra cost within 5 days of complaints received. |
| 206 | S&F ball bearings suitable for ceiling fans/exhaust fans of size 6201 complete all as specified and directed by Engr-in-Charge complete |
| 207 | All as per srl item No. 208 here-in-before but of size 6202 complete. |
| 208 | Taking out existing defective/worn out condenser any size/make and material and labour for condensor of capacity 2.5 mfd ,220 V including making connections etc complete all as specified and directed by Engr-in-Charge. |
| 209 | All as per srl item No.210 here-in-before but of capacity 1.5 mfd capacity. |
| 210 | M&L for rewinding of stator assembly of exhaust fan/bracket fans/wall mounting fans/pedestal fans 225 to 300mm sweep after strip opening of motor with proper grade/guage of super enamelled copper wiring so as to achieve original specifications i.e current rating and RPM including all insulating materials, re-assembling and replacement of worn out nuts, bolts, rubber bushes, clamps etc complete all as specified and directed by Engr-in-Charge. Note :- Taking down cleaning, greasing and re-fixing in position shall be measured and paid under srl item No.14 here-in-before.Note :-1. RPM test of exhaust fan with suitable tachometer will be done in the presence of Engr-in -Charge. 2. No T&P will be provided by the Dept. 3.Warranty period is 1 year,in case winding or any accessory i.e capacitor, ,becomes non functional within 1 year , it will be repaired without any extra cost within 5 days of complaints received. |
| 211 | Taking out existing worn out rubber reel, clamp and supply & fixing of rubber reel with clamps, MS nuts, bolts heavy duty of suitable size for hanging of ceiling fan to hook etc complete all as directed. |
| 212 | Taking out rusted screws & M&L for screws for fixing to different type/make blades of ceiling fans complete. |
| 213 | Taking out worn out/cracked canopy and supply & fixing canopy with screws to the celing fans of any size/make etc complete. (Set of 2 pieces) |
| 214 | Taking out rusted/worn out threaded down rod and supply & fixing down rod made out of 15 mm dia medium grade GI pipe having one side thread and on other side hole or both side threaded/hole 1.0 feet long complete. |
| 215 | Taking out existing defective flexible wire of any size and M&L for PVC copper cable flexible 3 core 1.0 Sqmm 1100 volts (FR) three core fixed to ceiling fan/exhaust fan (not more than 1.0 Mtrs to each fan). |
| 216 | Taking down worn out blades of exhaust fan off size 225 to 300mm sweep and supply and fixing new blades as per sample and make to the fan refixing in existing position etc complete. |
| 217 | Attending of complaints to continue electric supply after rectify the faults like no light, short circuit, sparking, current leakage etc including providing of small piece of electric wires if required of size upto 4 Sqmm single core and length n.exc 1 mtr complete all as specified and directed by Engineer-in-Charge.Note:-(i) any accessories found unserviceable will be replaced and shall be paid under respective items. (ii) one job will be considered for each bldg/Qtr per day irrespective of the No. of complaints. |
| 218 | Note - Rate quoated above all items inclusive provision as under :Making arrangement for establishment of centralized complaint centre in the existing building as under :- (a) Infrastructure required in Complaint cell i.e. telephone, furniture, stationary, transport and other necessary items/materials to establish a new complaint centre able to receive and manage complaints from the users by all means ie Manual complaint mechanism, Telephonic complaints mechanism, SMS complaint Mechanism and e-mail complaint mechanism and to maintain a consolidated list of complaints and its redressal mode indicating all its relevant data. (b) Computer data operator shall be able to manage all the necessary activities and having qualification as10+02 or Equivivalent in any discipline with minimum 6 month certificate course of computer applications (from a Govt recognized institute), (c ) Provision and maintenance of all tools, plants, equipment and safely gear required for tradesmen under this contract (d) Provision of communication facilities to supervisor and tradesmen. (e) Monitoring and management of complaints report from generation to execution of complaint including pending complaints. (f) Updating status of lodged complaints before change of eight hour shift. (g) Provision of motorized conveyance for deployment to all tradesmen under this contract. (h) Basic inputs to be noted from the complainants will be locality, Building No, Qtr No, Name and Rank of complaint and exact nature of complaint and mobile No/ telephone (j) On lodging the complaint, the Complaint No will be assigned for reference . Also system should indicate an approximate time for repairs. Accordingly a corresponding complaint slip shall be generated by the system with all relevant info. Complaint slip should be printed in triplicate and to be handed over immediately to Supervisor who shall detail appropriate tradesmen for repair with required materials/store. One copy of complaint shall be retained in complaint centre and two copies with tradesmen. |
| 219 | (k) On both copies of complaint slip, status of the complaint attended shall be endorsed by the complaint/user. One copy to be retained by the complainant and second copy to be with tradesmen for handing over in the complaint centre. Reasons for non attending of complaint etc shall be recorded alongwith estimate of expected time to attend and rectifying the complaint. (l) At the end of each day, summary of complaints shall be prepared and generated indicating No of complaints lodged, attended in time, Reasons for not attending , probable time required for attending the pending complaints etc. At the end of every month complaints attended, complaints completed & complaints balance submitted by the contractor.(m) JE in charge of MES will review the complaints recorded in the system daily and will carry out personal inspection of complaints attended and its status and will take remedial measures in this regard. (n) AGE will visit the complaint cell at least twice a week and GE at least once a weak to check the efficacy of the system and record their remarks accordingly. Note : Contractor shall be responsible for followings :- (i) Installation of landline telephone connection with internet broadband facility, obtaining SIM cards for mobile phones for supervisor and workers, deployed by the contractor. (ii) Payment of telephone bills, internet charges, mobile bills, expenses etc shall be borne by the contractor and no claim whatsoever on this account will be admissible by the department. (iii)A Computer/PC System with internet Connection for the Complaints lodging and Supervising will be Provided by the Contractor and will not be paid Seperately.(iv)Space for complaint cell/Office & Store will be Provided by the Department. And for any Security Breach/Theft Activity department will not be responsible. Contractor Have to arranged All Security Things By Self.(v) The penalty for Rs 50 per complaint will be imposed on contractor for not attending any complaint within 24 hours after reciept of complain by any means as specified. |
| 220 | Note:-The accepted amount will be arrived after deducting the Sch of credit i.e. Rs 1,05,062.00 and any other reduction if any from quoted amount. Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail