| 1 | GENERAL SUMMARYNOTE: Schedule ‘A’ Part - II to XIII are prepriced by MES under Ser No. 03 to 14. Bidders shall insert their lumpsum amount in the Green coloured field under Col-6 only. |
| 2 | Lumpsum price worked out by the tenderer for \\"BUILDINGS/STRUCTURES\\" as listed in Schedule ‘A’ Part- I |
| 3 | Construction of RCC retaining wall upto 4 m height and 150m length by Analysis, design, Engineering, detailing, & Structural drgs including concertina coil over retaining wall as required at site and as marked on site plan for the entire area of Site Plan as per the DBR vetted by IIT/NIT and approved by Accepting Officer.Note: If the actual length of Retaining wall as per the Contractor's design / proposal of site development as shown on site plan turns out to be different the variation in length shall be measured using Pro-rata. |
| 4 | Lumpsum price worked out by the tenderer for \\"EXCAVATION & EARTHWORK INCLUDING SITE CLEARANCE AND LAND DEVELOPMENT\\" as listed in Schedule ‘A’ Part- II |
| 5 | Lumpsum price worked out by the tenderer for \\"EXTERNAL WATER SUPPLY\\" as listed in Schedule ‘A’ Part-III |
| 6 | Lumpsum price worked out by the tenderer for \\"EXTERNAL ELECTRIC SUPPLY\\" as listed in Schedule ‘A’ Part- IV |
| 7 | Lumpsum price worked out by the tenderer for \\"ROAD / PATH / CULVERT/HARD STANDING\\" as listed in Schedule ‘A’ Part- V |
| 8 | Lumpsum price worked out by the tenderer for \\"AREA DRAINAGE\\" as listed in Schedule ‘A’ Part- VI |
| 9 | Lumpsum price worked out by the tenderer for \\"SEWAGE DISPOSAL\\" as listed in Schedule ‘A’ Part- VII |
| 10 | Lumpsum price worked out by the tenderer for \\"COMPOUND WALL,FENCING,GATES\\" as listed in Schedule ‘A’ Part- VIII |
| 11 | Lumpsum price worked out by the tenderer for \\"COOLING APPLIANCES\\" as listed in Schedule ‘A’ Part- IX |
| 12 | Lumpsum price worked out by the tenderer for \\"CONDUITS\\" as listed in Schedule ‘A’ Part- X |
| 13 | Lumpsum price worked out by the tenderer for \\"CHEMICAL EARTHING\\" as listed in Schedule ‘A’ Part- XI |
| 14 | Lumpsum price worked out by the tenderer for \\"FLAME PROOF LIGHTS, INDUSTRIAL SOCKETS & HIGH BAY LIGHTS\\" as listed in Schedule ‘A’ Part- XII |
| 15 | Lumpsum price worked out by the tenderer for \\"LIGHTNING PROTECTION\\" as listed in Schedule ‘A’ Part- XIII |
| 16 | Schedule \\"A\\" Part - XIV [Miscellaneous Items] [Tenderer has to quote unit rate under Col 6] |
| 17 | Supply of approved soil from outside of MD land at a distance exceeding 5 KMs but not exceeding 15KMs and depositing where directed at a level not exceeding 1.5m above starting point complete all as specified and directed by Engr-in-Charge.Note : Road/ HS area soil Qty taken upto sub grade level i.e upto bottom of Granular Sub Base (GSB) . |
| 18 | M & L for addition alteration in old GI pipe, screwing, cutting, threading fixing of valve, attend the minor work regarding pipe line complete all as specified and directed by Engr-in-Charge. |
| 19 | M & L for Valve Chamber of internal size 900mm x 900mm x 900mm including excavation, brickwork, GI Plate, Angle iron work etc complete all as specified and directed by Engr-in-Charge. |
| 20 | M & L cutting of road, hard standing made of concrete or premix carpet, WBM, soiling and morrum filling for laying of pipeline all as directed and making good the road/hard standing by using all old/new materials and with PCC (1:2:4) etc, required to match with the existing surface complete all as specified and directed by Engr-in-Charge. |
| 21 | Supply, install testing and commissioning weather and vermin proof Outdoor type L.T. Panel board (Main LT Panel Board) factory fabricated cubicle/kiosk type totally enclosed IP 54 made out of 3 mm thick CRCA sheet metal enclosure of suitable size, with angle iron frame of M.S. angle 50x50x6 mm suitable for operation on 3 phase 4 wire, 440 volts 50 HZ system, with hinged panel doors (covers) on two sides with handles, bottom gland plate and locking arrangement consisting of sufficient Nos of circular cable entry holes at bottom only with suitable PVC/rubber bushes to prevent ingress of water/vermin etc, inside the enclosure, the required nos of holes to be fixed with chromium plated brass cable glands for cable entry and exit complete with necessary internal wiring with stranded copper conductor PVC insulated cables of adequate size, duly spray painted grey hammer tone with one coat of red oxide primer and two coats of synthetic enamel paint of gray or any other approved colour, including connecting with L.T. armoured incoming and outgoing cables and including required sizes of cable lugs of aluminum complete all as specified and directed and consisting of following :- (a) Copper bus bar 800 Amps for 3 phase & neutral (b) ACB 4 Pole, 415 V, with Michroprocessor based EOD (Manual Fixed type) of capacity 630 Amps - 01 No. (As Incomer) Please Enable Macros to View BoQ information |
| 22 | Supply, install testing and commissioning weather and vermin proof Outdoor type L.T. Panel board (Main LT Panel Board) factory fabricated cubicle/kiosk type totally enclosed IP 54 made out of 3 mm thick CRCA sheet metal enclosure of suitable size, with angle iron frame of M.S. angle 50x50x6 mm suitable for operation on 3 phase 4 wire, 440 volts 50 HZ system, with hinged panel doors (covers) on two sides with handles, bottom gland plate and locking arrangement consisting of sufficient Nos of circular cable entry holes at bottom only with suitable PVC/rubber bushes to prevent ingress of water/vermin etc, inside the enclosure, the required nos of holes to be fixed with chromium plated brass cable glands for cable entry and exit complete with necessary internal wiring with stranded copper conductor PVC insulated cables of adequate size, duly spray painted grey hammer tone with one coat of red oxide primer and two coats of synthetic enamel paint of gray or any other approved colour, including connecting with L.T. armoured incoming and outgoing cables and including required sizes of cable lugs of aluminum complete all as specified and directed and consisting of following :- (a) Copper bus bar 800 Amps for 3 phase & neutral (b) ACB 4 Pole, 415 V, with Michroprocessor based EOD (Manual Fixed type) of capacity 630 Amps - 01 No. (As Incomer) Please Enable Macros to View BoQ information |