| 1 | Schedule-A |
| 2 | Taking down carefully copper/aluminium point wiring (light, Fan, Socket or power) fitting such as switches, ceiling roses, pendents, regulators, sockets etc complete removing material to store for keeping in safe custody and making good disturbed surfaces of walls, floors etc all as specified as directed. |
| 3 | Taking down of existing old unserviceable submain wiring complete all as specified and as directed. |
| 4 | Taking down of building security lights/high bay lights of any type and capacity complete all as specified and as directed. |
| 5 | Taking down of LED T/L/Ceilling light/Round light/Bulkhed light of any type and capacity complete all as specified and as directed. |
| 6 | M & L for concealed point wiring for light/Fan/Independant sockets point with 1.50 sqmm (nominal area), FRLS PVC insulated, unsheathed, single core multi-stranded copper conductor cable, 1100 volts grade,ISI marked controlled by one one-way switch, drawn through and including concealed medium grade PVC conduit not less than 20 mm dia, ISI marked, with all accessories(PVC Casing and caping to be done wherever wiring to be run on ceilings and concrete surfaces including one run of 1.5 sqmm FRLS muti stranded copper conductor (Green colour cable) as earth continuity wire connected to common earth dolly, including sunk sheet steel terminal box made out of 1.20 mm thick and not less than 60 mm in depth GI/MS/ prssed steel terminal box to be conclead in wall, duly painted with two coates of anti corrosive black bituminous paint over a coat of red oxide primer in and out sides and two coated of aluminium paint on internal surface , including laminated hylum sheet cover, ISI marked of Make\\" Hylem\\" for mounting of fittings like switches, sockets, fan regulators etc. fixed with galvanised screw and cup washer complete all as specified and directed. Note : Wiring to be done as per arroved colour code in IE rule.Rate includes chase cutting for concealed wiring. |
| 7 | one light point controlled by two-way switches with cables 1.5 Sqmm size |
| 8 | Supply and Fixing of modular switches 1 way, 6 Amp 1 module complete all as specified & directed by Engineer - In-Charge. |
| 9 | Supply and fixing in replacement of switch 2 way 6 Amps, 1 module |
| 10 | M&L for modular Metal flush box 3 module fixed on wall in concealed position and making good the same to match the existing surface |
| 11 | M&L for modular Metal flush box 6 module fixed on wall in concealed position and making good the same to match the existing surface |
| 12 | S&F white cover plate with frame of following module complete all specified and directed. |
| 13 | white cover plate with frame 3 module |
| 14 | white cover plate with frame 4 module |
| 15 | Fixing of Ceiling Rose, 3 phase polycarbonate isolated body complete all as specified & directed by Engineer - In-Charge.Note : Ceiling rose will be issue by the department. |
| 16 | Supply and fixing LED lights fitting 1x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete. |
| 17 | Supply and fixing LED building security light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and as directed. |
| 18 | S&F bracket made of GI pipe light grade 40mm bore bent to shape as required at site for street light fitting 1.2 m in length and fixed on wall/pole including necessary MS clamps, nuts, bolts etc complete all as specified and as directed. |
| 19 | M&L sub main wiring with two single core PVC-FRLS insulated unsheathed multi strand copper conductor cable of size 6 sqmm drawn in new /existing conduit with 6 Sqmm PVC-FRLS insulated unsheathed multi strand copper conductor as a continuous earth wire complete all as specified incl. taking down old unserviceable sub main wiring completeNote for item Srl No 20: (i) Two single core cable and one run of earth copper conductor will be measured and paid as one unit length |
| 20 | Supply and fixing in replacement of heat proof rubber pvc Gasket suitable for 25 Lrs geyser as per site requirement and complete all as specified & as directed by Engineer-in-charge. |
| 21 | Supply and fixing in replacement of heavy duty element holding assembly with provision of safety valve in its inlet pockets for thermostate, drain plug complete all as per site requirement and all as specified & directed by Engineer-in-charge. |
| 22 | Supply & fix in replacement of insulation of 25 Ltrs geyser as per existing insulating material in existing quantity for each geyser complete all as specified and as directed by Engineer-in charge. |
| 23 | Supply & Fix in replacement of fasteners up to 8 inch for fixing of geyser complete all as specified and as directed by Engineer- in Charge. |
| 24 | S&F in replacement of metal clad plug 20A 2P+E, 230V AC , complete all as specified and as directed by Engr-in-Charge. |
| 25 | S&F in replacement of metal clad socket 20A 2P+E, 230V AC , complete all as specified and as directed by Engr-in-Charge. |
| 26 | Supply and fixing in replacement of 3 core flexible copper conductor of size 2.5 sqmm cable 1100V grade complete all as specified and as directed by Engineer- in Charge. |
| 27 | Supply and fixing in replacement of brass ends wiremesh type stainless steel flexible hotwater connection pipe upto 2.0 feet as per requirement complete all as specified and as directed by engineer-in-charge. |
| 28 | Supply and fixing in replacement of auto cutoff system for geyser as per matching existing complete all as specified and as directed by Engineer- in Charge. |
| 29 | Supply and fixing in replacement of MTS thermostate for geyser as per matching existing complete all as specified and as directed by Engineer- in Charge. |
| 30 | Supply and fixing in replacement of MTS rectangle element 1.5/2.0 KW for geyser as per matching existing complete all as specified and as directed by Engineer- in Charge. |
| 31 | Supply and fixing in replacement of MTS round element 1.5/2.0 KW for geyser as per matching existing complete all as specified and as directed by Engineer- in Charge. |
| 32 | Supply and fixing in replacement of triangle type heating element 1.5/2.0 KW for geyser as per matching existing complete all as specified and as directed by Engineer- in Charge. |
| 33 | Supply and fixing in replacement of indicating lamps as per the site requirement complete all as specified and as directed by Engineer-in-charge. |
| 34 | Supply & Fix in replacement of inner tank suitable for 25 Lrs capacity geyser as per existing gauge and shape complete all as specified and as directed by Engineer-in charge. |
| 35 | Supply & Fix in replacement of inner tank suitable for 50 Lrs capacity geyser as per existing gauge and shape complete all as specified and as directed by Engineer-in charge. |
| 36 | Supply & Fix in replacement of outer body 18 gauge complete with bottom and top cover as per matching to existing type and size for upto 50 Ltrs capacity geyser complete all as specified and as directed by Engineer- in Charge.. |
| 37 | Supply & Fix in replacement of top cover complete as per matching to existing type and size for upto 50 Ltrs capacity geyser complete all as specified and as directed by Engineer- in Charge. |
| 38 | Supply & Fix in replacement of bottom cover complete as per matching to existing type and size for upto 50 Ltrs capacity geyser complete all as specified and as directed by Engineer- in Charge. |
| 39 | Supply & Fix in replacement of outer ring GI steel of 18 gauge upto 3 inches height for holding of tank in geyser of capacity 25 to 50 Ltrs capacity complete all as specified and as directed by Engineer- in Charge. |
| 40 | Supply & Fix in replacement of apparture plate for geyser of capacity 25 to 50 Ltrs capacity as per matching to existing complete all as specified and as directed by Engineer- in Charge. |
| 41 | Supply & Fix in replacement of sleeve for protection of wire of geysers complete all as specified and as directed by Engineer-in-charge. |
| 42 | S&F in replacement of MCB SP of rating, 20 Amps, 240 volt, 10 KA 'B' Series complete all as specified and as directed by Engineer- in Charge. |
| 43 | Supply & fix in replacement of sheet metal enclosure for 220 volts 20 Amps with a three pin and earth plug top with socket and one single pole MCB 20 amps complete as well as specified and directed. |
| 44 | Disconnecting carefully water and electric connection from geysers and taking down of storage type water heater of capacity upto 50 ltr, 230 volt for cleaning and descaling of inner tank, heating plate assembly and element with suitable descaling solution properly including welding, soldering/brazing if required to arrest the minor leakage and re-assembling the complete geyser and refixing in existing position with fixing arrangement including necessary testings complate all as specified and directed. |
| 45 | Taking down unsv any type of submain wiring and M&L for concealed sub main wiring of two run with 04 Sqmm single core PVC insulated, FRLS, flexible multi stranded copper conductor cable 1100 volts grade, drawn through and including PVC conduit pipe 25 mm dia medium grade and accessories of suitable size and fixed on concealed surface of wall/ceiling with cutting chases for conduit including one run of 4.0 Sqmm single core PVC insulated, FRLS , flexible multi stranded copper cable as earth continuity conductor in green color all as specified and as directed.Note- (a) Two runs of single core cable with one run of earth continuity cable including PVC conduit and its accessories will be measured and paid as one unit.(b) Make disturbed surface good to wall/floors . |
| 46 | Taking down unsv any type of submain wiring and M&L for sub main wiring of two run with 04 Sqmm single core PVC insulated, FRLS, flexible multi stranded copper conductor cable 1100 volts grade, drawn through and including PVC conduit pipe as per site requirement medium grade and accessories of suitable size and fixed on wall/ceiling including one run of 4.0 Sqmm single core PVC insulated, FRLS , flexible copper cable as earth continuity conductor in green color all as specified and as directed. |
| 47 | Supply and fixing in replacement of PVC conduit pipe of size of size 20 mm complete all as specified and as directed by Engineer- in Charge. |
| 48 | Supply and fixing in replacement of 16 amp 3 pin plug complete all as specified and as directed by Engineer- in Charge. |
| 49 | Supply and fixing in replacement of 16 amp 3/5 pin Multi socket complete all as specified and as directed by Engineer- in Charge. |
| 50 | Supply and fixing in replacement of 16 amp 3 pin Switch complete all as specified and as directed by Engineer- in Charge. |
| 51 | S&F LED driver 15W 240 Volt 50Hz suitable for existing philips fancy rounded ceilling light Type: DN170C LED10S-6500 PSU WH complete all as specified and as directed by Engr-in charge. |
| 52 | S&F LED driver 21 W 240 Volt 50Hz suitable for existing Philips fancy rounded ceilling light Type: DN170C LED10S-6500 PSU WH complete all as specified and as directed by Engr-in charge. |
| 53 | S&F in replacement of wall Red & Green lamp fitting with bulb holder & LED Bulb complete with all accessories as per sample. |
| 54 | S&F in replacement of 2'X2' Surface /ceiling mounted light fitting 40/42W(10 % variation) LED including white diffuser complete with all connected accessories as per sample. |
| 55 | S&F in replacement of LED driver 38/40 W 240 Volt 50Hz suitable for existing 2'×2' rectangular ceilling light complete all as specified and as directed by Engr-in charge. |
| 56 | S&F in replacement of Lamp/ batten Holder for wall/surface mounted light fitting complete all as specified and as directed by Engineer- in Charge. |
| 57 | S&F in replacement of fancy type wall fitting with LED Bulb of 07W complete with all accessories as per sample complete all as specified and as directed by Engineer- in Charge. |
| 58 | S&F in replacement of Surface mounted round shaped 7 watt LED light fitting including white diffuser complete with all connected accessories as per sample complete all as specified and as directed by Engineer- in Charge. |
| 59 | Supply & fix in replacement of fluorescent tube light fitting flame proof FLP-WP of T5,1×28 W including integral reflector made of aluminium alloy LM6, with electronic ballest, bipin holders, connector blocks, etc and all accessories pre-wired and including connecting up with twincore twisted flxible copper condector with suitable size complete all as spceified and as directed by Engr-ni charge. |
| 60 | S&F in replacement 40/42 Watt (+/- 5%) LED recess mounting fitting(1' x 4') CRCA powder coated having polycarbonate diffuser powedered by independent electronic LED driver haing IP 20 protection,CCT 6000 K,230/240 VAC,lumen efficacy > 140 lm/w including connecting up with twin core twisted flexible copper conductor cable with suitable size all as specified and as directed. |
| 61 | Supply and fix in replacement of industrial wall mounted plug socket combined in polycarbonate enclosure suitable for IP44 degree of protection 16/20 Amps rating 2P+E, complete all as specified and as directed by Engineer- in Charge. Please Enable Macros to View BoQ information |
| 62 | Supply and fix in replacement of industrial wall mounted plug socket combined in polycarbonate enclosure suitable for IP44 degree of protection 16/20 Amps rating 2P+E, complete all as specified and as directed by Engineer- in Charge. Please Enable Macros to View BoQ information |