| 1 | S&F solar street light luminaire efficacy of 120 lumen/watt and system wattage of 30 watt having compact and fully integrated design with intelligent features includes a built in solar Panel, lithium Ferro phosphate Battery, charge Controller and Motion sensor including all fixing accessories for existing pole complete all as specified and direced by Engr in Charge. |
| 2 | Supply, install and erect in true vertical position (or to be fixed in an inclined position as strut pole) 6 mtrs Ohot dip Galvanized Octagonal pole, silver color complete with Top dia 70mm, Bottom dia 130 mm, 3mm thick, MS base plate 200X200X12mm and foundation bolt M20X600mm and street light bracket single arm suitable of LED street light including PCC and drilling of holes of required size etc complete all as specified and directed by Engr-in-Charge. |
| 3 | S&F in replacement outdoor type LED Rope (wave AC Rope 60D Strip IP65 50mtr long Rope) bright & even illumination with 270 lm/m light output, warm white colour/Blue Operting Voltage 140-270 Volts AC Supply 50Hz supply connection complete all as specified and directed by Engr-in-Charge. |
| 4 | S&F in replacement outdoor type Tiranga LED Rope light suitable for 9/11 mtr electric PCC/Steel Pole decorative, Operting Voltage 140-270 Volts 240V AC Supply 50Hz supply connection from down side Jn box including driver and two run of 1.5 sqmm single core unarmoured wire from Junction box complete all as specified and directed by Engr-in-Charge. |
| 5 | S&F in replacement capacity luminaires 500 watt LED >5700K with suitable bracket and nut bolt of new Flood light IP 66, pressure die cast aluminium body, Operating Voltage 140-270 Volts,140Lum/Watt, toughned class,indl LED with secondary lens incl making electric connection using two run of 1.5 sqmm single core unarmoured wire min length 1.5mtr complete all as specified and directed by Engr-in-Charge. |
| 6 | S&F in replacement outdoor type busbar of size not less than 70 x 50 x 25 cm suitable for 440 volt 3 phase 4 wire system made out of 3.15mm CRCA sheet powder coated,Four Nos 45cms long Aluminium bus bar capacity 250 Amp mounted on epoxy insulators provided with rust proof nuts bolts and washers having gasketed front two hinged doors with locking arrangement complete with suitable size of rust proof nuts, bolts, and washers etc.. complete with mounting accessories including PCC work complete all as specified and directed by Engr-in-Charge. |
| 7 | S&F in replacement of Circular, LED Post Top light, 45 watt 3000K, & 4500 lumens output & CRI>80, IK 10 with optical grade PC diffuser,Pressure die cost aluminium single body and IP66 , anti corrosive epoxy powder coated, the dia of the light suitable for top of the pole dia 60mm complete all as specified and directed by Engr-in-Charge. |
| 8 | S&F LED luminaire Post Top light, 45 watt 3000K , With 50000 Hourning hours of maintenance output & 4950 lumens output & CRI>70, IK 08 with aluminium housing . Bajaj CAT Part No BOR NX 45W 30K DO C3 GG S PT or equivalent in Philips/Havells/Wipro make complete all as specified and directed by Engr-in-Charge. |
| 9 | Taking out unsv street light including control switches and replacement with S/I/T/C of microprocessor based automatic Power Management Unit (PMU) suitable for operation on three phase 4-wire. The PMU shall maintain a constant voltage of 400V AC three-phase for a variable input range of 320-480V AC Three Phase, Frequency - 50Hz, Duty Cycle-Continuous, Oil Cooled (with Oil). In addition to above the PMU shall be provided with facility for automatic switching ON and switching OFF of the street lights settable astronomically according to the latitude and longitude and the Sunset and Sunrise of the location. The PMU shall also be provided with mains indicator in each phase, digital voltmeter to read Input and output, Auto/Manual operation facility, Input Low/High voltage indication, Press Button switches to increase/decrease the output in manual mode, Input/output connecting terminals, Automatic Low/High Voltage cut off,Overload and short circuit protection through suitable rated MCB in each phase, The PMU shall be provided with bypass switch of suitable rating including inter connections to isolate the PMU & Bypass the mains supply, input and output terminations. The entire assembly shall be housed in a sheet steel enclosure duly painted with two coats of Enamel paint. Specifications Advance Microcontroller based design and real-time clock base systems. Real time clock with inbuilt battery with life of more then 8 years Controller operates 365 days on real-time based clock with auto calculate sunrise and sunset times as per geographic location. Inbuilt auto recovery systems for power failure which helps in streetlight operation. Scrolling display of events which helps to monitoring the systems. key board operation. Auto / Manual facility by way of relay operation for faster service mode. User settable On Delay up to 99 minutes Staggering facility to switch OFF and switch ON lights by late night can save energy Three mode of staggering system 1) Rotation mode in this one phase will off at predetermine time and phase will selected on date basis to equal burning of all lamp. i.e to day R phase off tomorrow y phase OFF and day fater tomorrow B phase will be OFF ( 33 % energy saving ) 2) Alternate phase system in which to day R phase off tomorrow Y and B Phase OFF . For equal burning of lamp. ( 50 % energy saving ) 3) Any phase can be switch off at any time and any time can be ON ( Energy saving in range of 33 to 100 % ) Eight Date range programming facility to disable staggering mode for festival and special occasion. Manual stagger off facility for special requirement. Technical Specification Supply:3 Phase 230 VAC/ph + / – 25 %, R Y B N 4 Wire supply Systems. 50 Hz (+ / - 10 %) Power Consumption:2 W (Stand by) 5 W (on full load) Controller : 8 Bit micro controller Programming function : Switching on Longitude & Latitude base Real Time Clock : Inbuilt battery, with battery life of more then 8 years Parameter data protection : With special device which hold the data for more then 10 years without any power and Password protected. Display : 16 character and two lines LCD display with backlight. Contacts : 3 Potential free contacts for normal and staggering With fuse protection. Redundancy:Operates up to single phase 170 V Ac By pass : Provision to by pass by way of Auto / manual switch. |
| 10 | Repair of existing street light/Security light of any type or discription, fixed in vertical position with poles/wall/Boundry wall including disconnecting the electric connection, removing from pole/wall/Boundry wall if required, carrying out minor repairs like disconection of wire/cable, detecting and repair of UG cable fault, cleaning of carbon on OH/UG line and replacing starter/fuses,etc as required at site to make the items functional and refixing the same at same location or any other location, connecting with electric feeder and testing for functioning engaging sufficient man power and tool and plant etc to ensure safety of light/pole as well as working persons complete all as specified and directed.Note : (i) The un-serviceable items shall be replaced under respective items of relevent schedule as below .(ii) T&P viz tools , Trolly mounted transportation veh with operator, ladder any type are provided by the contractor to the electrician party. (iii) The contractor shall be rectified the street light complaint on priority within the 04 hrs. One complaint shall be considered as one Job.(iv) Everyday one electrician and one helper shall be check all Street light & security light whole the area of 23 Wing(v) All safety precaution will be taken by the Electrician/Helper incase of any lapse contractor will be responsible for the same.(vi) Before climbimg on parameter light contractor shall ensure that there is no power supply on parameter fencing by concerned AF Department.(vii) In addition with domestic area complaints contractor shall attend the compaints of all wing area if there is any emergency or requirement. |
| 11 | S&F in replacement capacity luminaires 45 watt LED >5700K with driver of new street light/security light IP 66,Operating Voltage 140-270 Volts, PF (0.90),LED driver current > 850 mA,external Surge Voltage Protection,toughned class,indl LED with secondary lens incl making electric connection using two run of 1.5 sqmm single core unarmoured wire min length 1.5mtr complete all as specified and directed by Engr-in-Charge. |
| 12 | S&F in replacement capacity luminaires 60 watt LED >5700K with driver of new street light/security light IP 66,Operating Voltage 140-270 Volts, PF (0.90),LED driver current > 850 mA,external Surge Voltage Protection,toughned class,indl LED with secondary lens incl making electric connection using two run of 1.5 sqmm single core unarmoured wire min length 1.5mtr complete all as specified and directed by Engr-in-Charge. |
| 13 | S&F in replacement capacity luminaires 90 watt LED >5700K with driver of new street light/security light IP 66,Operating Voltage 140-270 Volts, PF (0.90),LED driver current > 850 mA,external Surge Voltage Protection,toughned class,indl LED with secondary lens incl making electric connection using two run of 1.5 sqmm single core unarmoured wire min length 1.5mtr complete all as specified and directed by Engr-in-Charge. |
| 14 | S&F capacity luminaires 100 watt LED >5700K with suitable bracket and nut bolt of new Flood light IP 66,Operating Voltage 140-270 Volts, PF (0.90),LED driver current > 850 mA,Surge external Surge Voltage Protection,toughned class,indl LED with secondary lens incl making electric connection using two run of 1.5 sqmm single core unarmoured wire min length 1.5mtr complete all as specified and directed by Engr-in-Charge. |
| 15 | S&F capacity luminaires 120 watt LED >5700K with suitable bracket and nut bolt of new Flood light IP 66,Operating Voltage 140-270 Volts, PF (0.90),LED driver current > 850 mA,external Surge Voltage Protection,toughned class,indl LED with secondary lens incl making electric connection using two run of 1.5 sqmm single core unarmoured wire min length 1.5mtr complete all as specified and directed by Engr-in-Charge. |
| 16 | S&F capacity luminaires 150 watt LED >5700K with suitable bracket and nut bolt of new Flood light IP 66,Operating Voltage 140-270 Volts, PF (0.90),LED driver current > 850 mA,external Surge Voltage Protection,toughned class,indl LED with secondary lens incl making electric connection using two run of 1.5 sqmm single core unarmoured wire min length 1.5mtr complete all as specified and directed by Engr-in-Charge. |
| 17 | S&F LED aviation light 10 watt, rating voltage 215-240 V including necessary connection with two run of 1.50 sqmm single core unarmoured copper cable from junction box to High raised building/OH Water Tank/Tower etc fixed in repairs, complete all as specified and directed by Engr-in-Charge. Note :(i) A certificate from the manufactures for warranty minimum upto 3 years shall be obtained and submitted to the AGE/GE(ii) Any touch up of the existing surface due to changing of fittings shall be done by contractor with similar surface finish without extra cost to the departmet. |
| 18 | Labour only for taking down and lifting up high mast light fitting including replacing the unserviceable items to make the fitting serviceable ,serving, greasing of steel rope and adjust/repair the timer, S&Fin replacement the contacts lifting mechanism with all accessories as required, complete all as directed by the Engineer-in-Charge. Note :- LED Strip & LED Drivers will be measured and paid separately |
| 19 | M&L for Preparation of old cement based painted surfaces of RCC pole 9 mtr by cleaning of deposited materials, and painting with one coat of exterior emulsion weather coat paint of approved make and colour above the top of PCC coping. Painting of pole from top of coping to a height of 1.5mtr with two coats of synthetic enamel paint in white and sky blue alternate strip complete all as specified and directed by Engineer-in-Charge |
| 20 | S&F single core PVC insulated unshesthed cable copper conductor of size 1.5 sqmm multistranded drawing in non-metalic PVC rigid conduit complete all as specified and directed by Engr-in-Charge. (Note;- PVC Conduit will be Measure and paid seperatly as relevent item.) |
| 21 | S&F single core PVC insulated unshesthed cable copper conductor of size 2.5 sqmm multistranded drawing in non-metalic PVC rigid conduit complete all as specified and directed by Engr-in-Charge. (Note;- PVC Conduit will be Measure and paid seperatly as relevent item.) |
| 22 | S&F single core PVC insulated unshesthed cable copper conductor of size 10 sqmm multistranded for panel wiring complete all as specified and directed by Engr-in-Charge. |
| 23 | S&F PVC insulated heavy duty twin core 2.5 Sqmm Copper cable with an inner sheathing of PVC tape and over all PVC Sheathed in multi stranded conductor 1100 volts grade incl taking down old unserviceable one. |
| 24 | S&F two core flexible copper wire .75 Sqmm Copper cable PVC Sheathed insulated multi stranded conductor 1100 volts gradecomplete all as specified and directed by Engr-in-Charge. |
| 25 | S&F in replacement thermoplastic polycarbonate cable junction box hinged door type of size 200x160x 98 mm for 3 Phase and Nutral incoming cable, 3 Phase and Nutral outgoing cable and single Phase & Nutral connection for light fitting with aluminiuam bus bar of 15 x 3mm strip, 4 pole, 415 volt with insulator porceline and one MCB sp 6 Amp, 240 Volt and clamp system (screw less), shock proof safe IP-55, weather proof, rust, dust and water proof internally embedded gasket with provision for cable entry through gland alongwith MS clamps and mounting brackets as required at site complete all as specified & directed. |
| 26 | S&F Rigid non-metallic PVC conduit 25mm dia (Heavy duty) in concealed exclusive of boxes (junction/terminal) but inclusive of all tees, bends,elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc. including taking out old conduit complete all as specified and directed by Engr-in-Charge. |
| 27 | S&F MCB SPN 40 Amps C Curve 25 KA with Sheet metal encloser,complete all as specified and directed by Engr-in-Charge. |
| 28 | S&F MCB Single Pole Neutral 16/25 Amps C Curve 25 KA with Sheet metal encloser, complete all as specified and directed by Engr-in-Charge. |
| 29 | S&F Sheet metal encloser,DB Two Way complete all as specified and directed by Engr-in-Charge. |
| 30 | S&F LED Post top light 45W 5700K made in die cast aluminium bottom housing and spun aluminium top reflector with decorative PMMA Opal and clear diffuser and IP65 protection complete all as specified and directed by Engr-in-Charge. |
| 31 | S&F LED Garden light 9 W 5700K made in die cast aluminium alloy spigot and optical grade PMMA diffuser and IP65 protection height not less than 1.2mtr complete all as specified and directed by Engr-in-Charge. |
| 32 | S&F LED Road signal light(Red/Yellow/Green) made in die cast aluminium alloy and IP66 protection complete all as specified and directed by Engr-in-Charge. |
| 33 | S&F PVC insulated sheathed service wire twin core 04 Sqmm aluminium multi stranded conductor 1100 volts grade incl taking down old unserviceable one. |
| 34 | S&F PVC insulated sheathed service wire twin core 06 Sqmm aluminium multistranded conductor 1100 volts grade incl taking down old unserviceable one. |
| 35 | S&F PVC insulated sheathed service wire twin core 10 Sqmm aluminium multistranded conductor 1100 volts grade incl taking down old unserviceable one. |
| 36 | S&F PVC insulated sheathed service wire twin core 2.5 Sqmm aluminium multistranded conductor 1100 volts grade incl taking down old unserviceable one. |
| 37 | Preparation of old painted surface of 9 Mtr. steel tubular poles above the top of PCC coping. Painting of pole from top of coping to a height of 1.5mtr with two coats of synthetic enamel paint in white and sky blue alternate strip and painting the rest portion of pole of (approx length 7 mtr)including painting of cross arms/clamps etc complete with two coats of synthetic enamel aluminium paint and to the entire satisfaction of Engineer-in-Charge complete all as specified and directed |
| 38 | Supply and laying & testing UG cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (Heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 sq mm, 4 core, complete including disconnecting and taking out old existing unserviceable cable all as specified and directed by Engr-in-Charge. |
| 39 | All as per srl item No 38 here-in-before but of size 25 Sqmm 3.5 Core. |
| 40 | All as per srl item No 38 here-in-before but of size 35 Sqmm 3.5 Core. |
| 41 | All as per srl item No 38 here-in-before but of size 50 Sqmm 3.5 Core. |
| 42 | All as per srl item No 38 here-in-before but of size 10 Sqmm 4 Core. |
| 43 | All as per srl item No 38 here-in-before but of size 10 Sqmm 2 Core. |
| 44 | All as per srl item No 38 here-in-before but of size 6 Sqmm 2 Core. |
| 45 | Taking out carefully manually by excavation of existing LT/HT cable with loops and relaying with DWC pipe/brick the same after repair of cutting the damages / burnt parts of cable and reconnecting its into original positions complete with cable joints all as specified and directed by Engineer-in-Charge.Note:-(i) HT/LT Cable Joint & DWC Pipe/Brick will be measured and paid sepearetly. (ii) Unit rate shall be included in excavation and returning filling. (iii) Handling of UG cable to working site as ordered shall be carried out by the firm and rate for the same shall deem to be included in the unit rate. |
| 46 | Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth and getting out in any type of soil for laying of LT UG cables complete. Note:- The Rate quoted deemed to including cutting and removal of PSP Sheets wherever occured during excavation and the same shall be staged at desired location as directed at site |
| 47 | Returning, filling in, including spreading levelling, watering and well ramming in layers not exceeding 25 cm thick in hard dense soil |
| 48 | Removing excavated material not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point |
| 49 | S&F GI tubing light grade 50mm dia along the wall/in trenches/in duct/in culvert/road crossing/garden light/decorative road light and including provisioning of suitable mild steel flat iron clamps and bolts, nuts and double washers etc for holding of GI pipe alongwith poles including taking out old broken GI pipes, complete all as specified and as directed by Engr-in-Charge. |
| 50 | All as per srl item No 49 here-in-before but of dia 80 mm. |
| 51 | S&F in repairs ISI mark aluminium thimbles suitable for under ground LT cables of sizes 16/25 sqmm including cutting of exsting burn/dammaged cable after disconnecting from exsting position ,extending the cable from cable loop including neccesory earth work and reconnecting the same. |
| 52 | All as per srl item No 51 here-in-before but of size 35/50 Sqmm |
| 53 | Dismantling of interlocking cement concrete (any thickness/size), on floor fixed in cement mortar in single layer complete all as specified and directed by Engr-in-Charge. |
| 54 | M&L for machine pressed precast concrete interlocking paver block any shape and size confirming to IS- 15658-2006 of 60mm thickness , M-35 grade, with grey cement and pigment. complete all as specified and directed by Engr-in-Charge. |
| 55 | All as per srl item No 54 above but except interlocking cement concrete tiles, (Any thickness/size) (old interlocking tiles obtained from srl items No 30,complete all as specified and directed by Engr-in-Charge. |
| 56 | M&L 25 mm thick sand fillimg under floor/interlocking tiles etc complete all as specified and directed by Engr-in-Charge. |
| 57 | Demolition of cement concrete in ground floors and paving not exceeding 15cm thickness (below or above ground level) and disposing the rubbish to a distance exceeding |
| 58 | M&L for PCC 1:4:8 type D-2 (using 40mm graded stone aggregate) in sub base of floor finishing foundation filling and mass concrete complete all as specified and directed by Engr-in-Charge. |
| 59 | Supply LT Insulation tape High quality size minimum 20 mtr long x 2.5 CM width complete all as specified and directed by Engr-in-Charge. |
| 60 | S&F in replacement of MCCB 160 Amps 4 pole 25 KA adjustable thermal and fixed magnetic setting,complete all as specified and directed by Engr-in-Charge. |
| 61 | S&F in replacement of MCCB 100 Amps 4 pole 25 KA adjustable thermal and fixed magnetic setting,complete all as specified and directed by Engr-in-Charge. |
| 62 | S&F in replacement of MCCB 350 Amps 4 pole 36 KA with adjustable thermal and fixed magnetic setting, complete all as specified and directed by Engr-in-Charge. |
| 63 | S&F in replacement of MCCB 250 Amps 4 pole 35 KA with adjustable thermal and fixed magnetic setting, complete all as specified and directed by Engr-in-Charge. |
| 64 | S&F capacity luminaires 250 watt LED >5700K with suitable bracket and nut bolt of new Flood light IP 66,Operating Voltage 140-270 Volts, PF (0.90),LED driver current > 850 mA,external Surge Voltage Protection,toughned class,indl LED with secondary lens incl making electric connection using two run of 1.5 sqmm single core unarmoured wire min length 1.5mtr complete all as specified and directed by Engr-in-Charge. |
| 65 | S&F capacity luminaires 350 watt LED >5700K with suitable bracket and nut bolt of new Flood light IP 66,Operating Voltage 140-270 Volts, PF (0.90),LED driver current > 850 mA,external Surge Voltage Protection,toughned class,indl LED with secondary lens incl making electric connection using two run of 1.5 sqmm single core unarmoured wire min length 1.5mtr complete all as specified and directed by Engr-in-Charge. |
| 66 | Exacavation for cables loops near the poles LT Panels transformers, cutting the damages/burnt parts of cable and reconnecting its positions complete with thimbles, nut bolts, sleaves all as specified and directed by Engineer-in-Charge. |
| 67 | S & F in replacement Analog time switch complete (FM/1 Quartz,type QT(Daily)) 240V, 50Hz contact rating 16A/250 VAC (Resistive) Product code: J648B1 for aviation light ON/OFF complete all as specified and directed by Engr-in-Charge. |
| 68 | Supply and laying of DWC (Double Wall Corrugated) HDPE Pipe, ISI Marked IS 16205 Part-II, of outer dia of 50 mm and inner dia 38 mm with smooth internal and profiled external surface for non pressure under ground cable including all connected accessories like coupler, 'O' Ring etc, for protection of cable complete all as specified and directed by Engr-in-Charge. |
| 69 | SCHEDULE 'A' PART-II (Schedule of credit) Credit amount of Rs (Refer schedule of credit) for retrieved material mentioned in Sch 'A' Part-II of Tender documents in PDF form will be deducted offline during acceptance of tender of lowest bidder. Please Enable Macros to View BoQ information |