| 1 | Surface excavation n.exc 30cm deep and averaging 15cm deep and getting out in Hard/dense soil. |
| 2 | Excavating in Over areas n exc 1.5 in depth and getting out hard / dence soil complete all as specified and directed. |
| 3 | Excavating in Over areas exc 1.5 m but n exc 3 m in depth and getting out hard rock complete all as specified and directed. |
| 4 | Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, laying of pipes etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out hard/dense soil complete all as specified & directed. |
| 5 | Returning, filling in, trenches including spreading, leveling, watering and well ramming in layers not exceeding 25 cm complete all as specified and directed. |
| 6 | M&L for Sand filling under interlocking tiles or in foundations including watering and consolidation complete all as specified & directed by Engr-in-charge. |
| 7 | Removing excavated material not exc.50 m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed |
| 8 | M& L for Broken stone or boulders Hand packing (any thickness) at back of walls over arches etc. and raising (or lowering) to the required level complete all as specified and as directed. |
| 9 | M & L for hard core of gauge not exc. 63mm, deposited, spread and leveled in layers not exc. 15 cm thick, watered and rammed to a true surface using broken stone or boulders complete all as specified and directed. |
| 10 | M&L for Cement concrete type D-2 1:4:8 (40mm graded aggregate) in foundations, filling,sub base and mass concrete complete all as specified & directed by Engr-in-charge. |
| 11 | M&L for PCC C-1 1:3:6 (20 mm graded aggregate), in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, as directed complete all as specified and directed. |
| 12 | M&L precast cement concrete 1:3:6 type C1 (using 20mm graded aggregate) as in block masonry with solid blocks exc 10 cm in width and set in cement mortar 1:6 complete all as specified & directed. |
| 13 | M&L RCC (Design Mix ) M-30 using (20 mm graded aggregates ) as in foundation including rafts , Footing foundation beams plinth beam bases for column and mass concrete complete all as specified and directed.Note : Design/Sectional detail of RCC structure shall be decided by Engr-in-Charge as per ground requirement. |
| 14 | M&L RCC (Design Mix) M-30 using (20 mm graded aggregates ) for columns, pedestals, pillars, piers, posts and struts complete all as specified & directed.Note : Design/Sectional detail of RCC structure shall be decided by Engr-in-Charge as per ground requirement. |
| 15 | M&L for formwork to flat foundation, footing bases of columns raft and raft beams, sides and soffits of foundation and plinth beams and similar work fair finished flat surface of concrete complete all as specified |
| 16 | M&L for formwork to sides of pillars, posts, struts, piers, columns, pedestals and stanchions fair finished flat surface complete all as specified & directed |
| 17 | M&L for formwork edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/ PCC bands in walls, horizontal or sloping and similar work exc 10cm but n exc 20cm wide with fair finished flat surface of concrete complete all as specified |
| 18 | M&L for Mild steel HD bolts (machine made) of dia 20mm with hexagonal or squre heads at one end and screwed the other, or screwed both ends,each screwed end to be fitted with washers and one hexagonal or squre nut , 100 cm long icluding fixing in concrete casting complete all as specified and directed by engr-in-charge. |
| 19 | M&L for TMT bars 10 mm dia and over cut to length bent to shape recquired, includind cranking bendind spirally for hooping for column hooking ends and binding with and including MS wire (anneled) not less than .9 mm dia complete all as specified and directed |
| 20 | M&L for TMT bars 6 mm to 8 mm dia and over cut to length bent to shape recquired, includind cranking bendind spirally for hooping for column hooking ends and binding with and including MS wire (anneled) not less than .9 mm dia complete all as specified and directed |
| 21 | M&L for Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, including reqd welding, fixing of Gde-E-250 quality-A including cutting to dead length where required, notching, drilling, fitting, riveting and/or welding or connecting with bolts and nuts (including rivets or bolts and nuts), providing and fitting angle cleats, fish plates, gusset plates etc., also for wedging, plumbing, truing up and fixing, connections complete all as specified & directed by Engr-in-charge. |
| 22 | M&L Compound girders and stanchions, lattice girders, aerial masts, staging for water tanks and the like including caps, bases, splices etc. built up from two or more beam or channel sections or angles with plates, including all lattice bars, stiffeners, gusset plates, etc of Gde-E-250 quality-A including cutting to dead length where required, notching, drilling, fitting, riveting and/or welding or connecting with bolts and nuts (including rivets or bolts and nuts), providing and fitting angle cleats, fish plates, gusset plates etc., also for wedging, plumbing, truing up and fixing,connections complete all as directed by Engr-in-charge |
| 23 | M&L for Stairs (framed) including stringers, treades, landing, balusters, hand rails etc. including cleats, brackets, fixing, welding etc.of Gde-E-250 quality-A including cutting to dead length where required, notching, drilling, fitting, riveting and/or welding or connecting with bolts and nuts (including rivets or bolts and nuts), providing and fitting angle cleats, fish plates, gusset plates etc., also for wedging, plumbing, truing up and fixing, connections complete all as specified & directed by Engr-in-charge. |
| 24 | M&L for Factory Made, Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 80 mm thickness M-40 Grade with grey cement & no pigment complete all as specified by Engr-in-charge. |
| 25 | M&L for Chequered cement concrete tiles 25mm thick with grey cement & pigment in reqd proportion, set,area of each tile exceeding 0.05 sqm but not exceeding 0.09 sqm, jointed and pointed in near cement slurry in floors,laid on screed bed or bedding layer of mortar 15mm thick 1:6 cement mortar complete all as specified & directed |
| 26 | M&L for 150 mm thick plan cement concrete 1:2:4, type B1 (using 20 mm graded stone aggregate) as in hardstanding, path, flooring surface finished even & smooth without using extra cement complete all as specified & directed by Engr-in-charge. |
| 27 | M&L for rendering 15 mm thick on brick or concrete surface of walls in cement mortar 1:4 finished even & smooth without extra cement including mixing only water proofing compound as per manufacturer instruction on external wall complete. |
| 28 | M&L for raised pointing to block in course or ashlar masonry or concrete block walling in Cement mortar1:4 as specified by Engr-in-Charge and as directed |
| 29 | Material & Labour for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces complete all as specified. |
| 30 | M&L for preparation of new surfaces of steel exc 10cm width or girth and applying two coats of Aluminium paint over a coat of aluminium red oxide primer complete all as specified and as directed by Engineer-In-Charge. |
| 31 | S&F of GI water tubing medium grade. including all GI fittings and accessories as required at site complete all as specified and dircted for the sizes of 80mm dia bore |
| 32 | S&F of GI water tubing medium grade. including all GI fittings and accessories as required at site complete all as specified and dircted for the sizes of 50mm dia bore |
| 33 | S&F PVC pipe (SWR) pipes 75mm dia single socketed in any length with rubber ring joints, fixed to walls or floors as in weep holes complete all as specified & directed. |
| 34 | Supply & fixing cast iron sluice valve of size 50mm bore class-I PN-1.6 with gun metal spindle both and flanged long body type complete with all fitting and Including taking down the old one all as specified and directed by engineer in charge |
| 35 | Supply & fixing cast iron sluice valve of size 80mm bore class-I PN-1.6 with gun metal spindle both and flanged long body type complete with all fitting and Including taking down the old one all as specified and directed by engineer in charge |
| 36 | M&L for food grade epoxy coating on internal surface of steel / RCC water tank including thorough surface preparation by mechanical means (wire brushing / sand blasting as required) to remove rust, oil, grease and loose particles, making surface dry and dust free, applying one coat of approved epoxy primer and two coats of food grade epoxy coating (solvent free), each coat of required thickness, complete all as specified and as directed. |
| 37 | Disconnecting of existing 01 x incoming 80mm GI pipe line, 02 x 50mm water distribution line and reconnecting with new water steel tank complete all as specified and directed. |
| 38 | M&L for construction of brick masonary valve pit/chamber of size 600x600x900 mm (internal dimension) with brick work of sub class 'B' old size bricks built in cement morter 1:4 and 10mm thick rendering on internal and exposed external surface and including 40x40x6 mm mild steel angle frame 3.15mm thick mild steel sheet cover in two Nos shutters duly painted with one coat of bituminious paint of approved quality, with handle and locking arrangement complete including provn of Godrej(Freedom) lock complete all as specified and directed by Engr-in-Charge. Please Enable Macros to View BoQ information |