BOQ
| Sl. No. | Item Description |
| 1 | Demolition of existing roof complete of any description and in any position not otherwise specifically provided including removing rubbish material from work site at any distance all as specified. |
| 2 | M&L for cement concrete type C-2 1:3:6 (40mm graded aggregate) in MS pipe posts and mass concrete on roof top. |
| 3 | Use and waste of form work to sides of square, rectangular or polygon in shape columns, pillars, posts, rough finished surface of concrete. |
| 4 | S&F 0.63 mm thick Plain, galvanised, mild steel sheeting, in ridges, hips, valley gutters, drip and straight flashings (length and girth as fixed) with L or J type bolt, grade of zinc coating 275 gm/sqm complete all as specified and as directed. |
| 5 | S&F PVC (SWR) pipes of dia 110mm bore single socketed in any length with rubber ring joints fixed to walls with necessary clamps all as directed |
| 6 | S&F Steel work in MS tublar sections/Structural trusses, MS Square/RectangularCircular Tube & Joists /MS angle as columns / rafters including special shaped washer etc complete using ERW or indication butt welded tubes confirming to I.S 1161-1998 grade St-240 |
| 7 | S&F Rolled sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates Fe -410-W(Gde-E-250 qaulity-B) all as specifed and directed by Engr-in -Charge. |
| 8 | S&F plates(plain or chequered) channels,square cut or notched (ordinary and counter shunk forming holes,without any attachement. All as specified and directed by Engr-in-Charge |
| 9 | S&F MS flat wind ties for roof including securing bolts ,posts and struts including all necessary drilling bolt or riveting etc. and similar work confirming to FE-290 Gde e-165 |
| 10 | S&F Pre-painted galvatume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall,fixed with self tapping screws as specified. |
| 11 | S&F Pre-painted galvatume aluminium zinc coating GI based plain steel sheet 0.50mm thick on ridge an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall,fixed with self tapping screws as specified. |
| 12 | M&L for preparation of new steel surfaces, of any description, not otherwise described, over 10 cm in width or girth and applying two coats of anti-corrosive epoxy(poly Urethane based) over a coat of epoxy primer of approved make complete all as specified and directed. |
| 13 | Demolition of Reinforced cement Concrete water tanks of any size and any height over roof slab and making roof surface good including removing debris Outside of Mod land as directed by Engg-in-Charge. |
| 14 | S&F Rotational moulded polyethylene water storage tanks (cylin-drical vertical with closed top) triple layerd 1000 ltrs capacity hoisted and fixed in position including 25mm dia float ball brass valve and flynut complete,screwed for iron pipe or brass ferrule and fixed all as specified |
| 15 | Taking up or down steel tubing 25/32 mm and connection, including cleaning for refixing or removal to store complete all as specified. |
| 16 | S&F CPVC pipes, SDR 11, 25 mm outer dia of pressure rating 6 kgf/sqcm conforming to IS-15778 with all fittings such as Tee,Bends, elbows ,unions ,sockets and end pieces etc to receive fittings and fixed with solvents fixed to walls/ floors with all clamps in Shafts/ducts with all necessary scaffolding to fix the pipes and testing the joints under prescribed pressure |
| 17 | Complete removal of external treatment & applying one coat of alkali primer incl crack filling complete all as specified. |
| 18 | M&L for 2mm thick Rigor Texture of approved pattern on wall, chajja over primed surfaces (Excluding primer) complete all as specified. |
| 19 | M&L for One coat of No Damp waterproofing base coat complete all as specified. |
| 20 | M&L for Two coat of No Dust Exterior Emulsion of Approved Shade complete all as specified. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
CompletedCorrigendum-2 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 2 daysBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 2 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 4 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender