| 1 | M&L for taking out of different size cable from trench |
| 2 | M&L in for Surface dressing of the ground of substation yard area including clearing of all vegetation, grass, roots, rubbish, and loose materials, removal of top organic soil (if required) not exceeding 15 cm deep, and dressing the ground to required lines, levels, and slopes. The surface shall be properly levelled, compacted, and rammed to achieve a firm and even subgrade, ensuring proper drainage and elimination of undulations Complete all as speicified. |
| 3 | M&L in rep for Exc in trenches not exc. 1.5 m wide and not exc. 1.5 in depth for foundation of poles, stay assy etc. and getting out in hard / dense soil complete all as specified and directed. |
| 4 | M&L in rep for Returning filling in including spreading levelling watering and well ramming in layers not exc. 25 cm thick each complete all as specified and directed. |
| 5 | M&L in rep for Removing excavated material to a distance not exc. 50 mtr and depositing where directed at a level not exc. 1.5 mtr above the starting point of any type of soil complete all as specified and directed. |
| 6 | Supply and laying in rep for Sand cushioning for the purpose of floors and laying of cables including watering and consolidation. |
| 7 | Supplying and laying in rep for reinforced precast concrete cable cover class LV , type 1 ,size flat size 250 x 150 x 40 mm all asper required and directed . |
| 8 | M&L in rep for replacement of XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 120 sq. mm 3.5 core complete all as directed by Engr-In-Charge. |
| 9 | -do- but for 95 sqmm 3.5 core |
| 10 | -do- but for 70 sqmm 4.0 core |
| 11 | -do- but for 50 sqmm 4.0 core |
| 12 | M&L in rep for laying of 40 mm crushed stone aggregate at eletrical inst, Complete all as specified and directed by Engr-in-Charge. |
| 13 | Material & labour in rep for earthing complete with galvanized steel earth plate electrode 600mm x 600mm x 6mm buried directly in ground (earth pit not less than 2.25 metre deep below ground level) vertically, with top edge of the plate not less than 1.5 mtr below normal ground level, connected to galvanized iron earth strip of size 32 x 6mm by means of nuts, bolts, washers of GI steel all as shown on electrical plate No 3 of MES schedule part I-2009 connected to earthing test point & to main switch board and testing on completion with and including necessary excavation and earth work in any type soil, earth lead connected to earth test point & to main switch board etc with & including adequate quantity of charcoal dust and common salt, test point, PCC (1:3:6) type C-1 (using 20mm graded black trap/granite/Basalt stone aggregate) for earth pit with 40 x 40 x 6mm mild steel angle iron frame for cover, internal surface of concrete shall be given 10mm thick plaster in CM 1:4, pre cast RCC (1:2:4) type B-1 (using 20mm graded black trap/granite/Basalt stone aggregate) 40mm thick cover, reinforced with 8mm dia deformed or TMT bars 3 Nos both way with 12mm dia round bar handle, GI light grade watering pipe 20 mm dia with funnel and wire mesh and 40mm dia GI light grade earth lead protection pipe etc complete all as specified and directed. NOTE: - (i) Earth strip and its protection pipe upto and including 7.5 mtr only from the top of earth electrode are included under this item (ii) Any joints in earth strip from earth electrode to test point shall not be allowed / permitted. |
| 14 | M&L in rep for earth continuity conductor using GI strip 32 x 6 mm as earthing lead complete all as directed incl taking down the old unserviceable complete. |
| 15 | Supply and fix in rep for light grade galvanised iron tube 80 mm bore with all fittings and fixed to walls / ceiling or laid in floor, pole or laid in trenches and road crossings including sealing ends with Hession cloth impregnated with bituminous compound in ground and with teak wood bushes for ends fixed with walls / poles complete all as specified and as directed. |
| 16 | Supply and laying in rep Rubber insulation mate 2M x1M x12mm chequered black in colour Make: Jyoti/ Insulica/ Bitex |
| 17 | Supply only rubber hand gloves suitable for 33kv grade all as approved |
| 18 | M & L in rep for 50 mm thick PCC 1:2:4 type B1 (using 20 mm graded stone aggregate) as in floor finishing even and smooth without using extra cement and making impression of expanded metal, whilst concrete is green over 100 mm thick PCC (1:4:8) type D-2(using 40 mm graded stone aggregate) complete all as specified and directed by the Engineer in Charge. |
| 19 | M&L in rep for fabrication of Fire fighting eqpt post made of angle iron frame structure with roof canopy the structure angle size not less than 50x50x6mm and canopy sheet steel 3 mm thick in shape and One coat of approved primer (suitable for steel) shall be applied uniformly and allowed to dry completely. Thereafter, two coats of synthetic enamel paint in red colour of approved make and as directed by EIC including housing of different equipment's as taken under below . |
| 20 | Supply only fire extinguisher CO2 Wheeled Fire Extinguisher ISI marked conforming to IS: 16018. Capacity 9Kg. Complete with composite trolley with handle & wheel, operation manual, wheel type release valve, locking arrangement and shut-off valve fitted with delivery hose horn. Operating Temperature: -30ºC to + 55ºC. Brand LIFEGUARD |
| 21 | Supply only Powder type Fire Extinguisher (Stored Pressure type) Capacity 06 Kg duly ISI marked conforming to IS: 15683:2018, with IS 4308, ISI marked ABC powder complete with squeeze grip release valve, discharge pipe, locking arrangement, pressure gauge, operation manual and bracket. Operating Temperature: -30ºC to + 60ºC. Brand LIFEGUARD |
| 22 | Supply only iron fire bucket 10 ltr capacity complete all as approved |
| 23 | Supply only fire hook with 7 feet bamboo handle all as approved |
| 24 | Supply only fire beater with 7 feet bamboo handle all as approved |
| 25 | M&L in rep for fabricating, and erecting an outdoor shed for DG set and their electric panel, using 40 mm × 40 mm x 2.5 mm, MS square hollow sections for structural framework including columns, beams, purlins, bracings, etc., conforming to relevant IS standards. The members shall be cut, aligned, welded, and erected in position true to line and level, including necessary base plates, gussets, anchor fasteners, and all fittings as required. Roofing shall be done with corrugated galvanized iron (CGI) sheets of approved thickness (not less than 0.50 mm), fixed over the framework with J-hooks, nuts, bolts, washers, and bitumen washers, including necessary overlaps (end and side laps) to ensure watertightness. |
| 26 | Total contract sum shall be calculated after deduction of schedule of credit amount of Rs. 10,850.00 Please Enable Macros to View BoQ information |