| 1 | Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth for laying of pipe, cable, foundation of electric pole etc and getting out in soft/loose soil, complete all as specified and directed. |
| 2 | Returning, filling in including spreading leveling watering and well ramming in layers not exc. 25 cm thick complete all as specified and directed. |
| 3 | Removing surplus soil to a distance not exc. 50 M and depositing where directed at a level not exceeding 1.5 Mtr above the starting point complete all as specified and directed. |
| 4 | Supply and spreading fine sand in trenches for cushioning of under ground cable/ filling of cable ducts all as directed by Engr-in-Charge at site. Note:- Only punned thickness 18 cm shall be measured for payment purpose complete all as specified and directed. |
| 5 | M&L for Burnt bricks sub class 'B' laid flat dry across the cable for cable protection complete all as specified and directed. |
| 6 | Sppply & Laying XLPE insulated, armoured, electric cable with aluminium conductor, 1100 volts grade, laid in trenches, fixed on poles/ walls or passing through pipes including provision of necessary lugs and glands & making necessary connection including taking down old unsv cable of any core complete all as specified and directed, for the following :- |
| 7 | All as per Srl item No. 6.00 above but 10 Sqmm 2 core complete all as specified and directed. |
| 8 | All as per Srl item No. 6.00 above but 10 Sqmm 4 core complete all as specified and directed. |
| 9 | All as per Srl item No. 6.00 abive but 16 sqmm 4 core complete all as specified and directed. |
| 10 | S&F in repair 4 pole power contractor type MCX of capacity 25 Amps conforms To IS/ IECN 60947-4-1 & IEC 60947-4-1 including taking down old unsv one complete all as specified and directed. |
| 11 | S&F in repair 4 pole power contractor type MCX of capacity 32 Amps conforms To IS/ IECN 60947-4-1 & IEC 60947-4-1 including taking down old unsv one complete all as specified and directed. |
| 12 | S&F in repair 4 pole power contractor type MCX of capacity 40 Amps conforms To IS/ IECN 60947-4-1 & IEC 60947-4-1 including taking down old unsv one complete all as specified and directed. |
| 13 | S&F in replacement of Automatic Street Light control switch for three phase load of 5 KW, using Infrared Sensor based NATURE SWITCH for automatic switching of street light. Nature Switch operation should be based on Natural Light Lux level. Required illuminance level for switching ON is ≤ 30 Lux and for switching OFF ≥ 10 Lux. The sensor should also have part night operation facility of min. 4 hrs to max. 12 hrs. The Sensor along with 03 Nos contactors each of 20 to 25 Amps capacity, Incoming MCBs and Outgoing MCBs of 20-25 Amps (03 Nos) and auto/ manual operation (Senser by Pass), size of circuit wiring should be multistranded FRLSH min size of 10 Sqmm should be enclosed in a pole/ wall mounted enclosure made of rust proof, Electric shock Proof, Termite proof and FR grade SMC Junction box conforming to IP54 and model Swadeep 02EC5KW3P complete all as specified and directed. |
| 14 | Supply and fixing in repair flexible heavy duty, 4 core 4 Sqmm PVC sheathed copper conductor cable, 1100 Volts grade conforming to IS:694/ IS: 1554 (Part-1), laid/ connecting in existing highmast poles/ pipes/ on wall/ ceiling including dressing, clamping, saddles, identification ferrules, glands and lugs if required at site complete all as specified and directed. |
| 15 | Supply and fixing in repair 3 core 1.5 Sqmm PVC insulated and PVC sheathed copper conductor cable, 1100 Volts grade conforming to IS:694, laid/ connecting in existing poles/ highmast poles/ light fittings at site. complete all as specified and directed. |
| 16 | M&L in repair, servicing, overhauling & maintenance of 30 mtr highmast poles asseccories/ connected parts such as lantern carriage assembly including guide rollers, brackets and lubrication, servicing of head frame assembly including pulley blocks and bearings, servicing of of motorized winch system including electric motor and gearbox, servicing including greasing of manual winch mechanism including worm gear assembly, servicing of guide pulley system incl lubrication, checking and tightening of foundation bolts and base plate, cleaning of lantern carriage flood lights, checking and tightening all electrical connections, testing of motorized raising and lowering complete with complete satisfaction, complete all as specified and directed. |
| 17 | Supply, fixing, testing and commissioning in repair LED aviation obstruction light (Red colour) suitable for installation on high mast pole including lamp, driver and weatherproof housing with GI mounting bracket/ clamp for fixing obstruction light on top of highmast aviation light complete with 3 core 1.5 Sqmm PVC insulated copper cable and weatherproof junction box for connection, complete all as specified and directed. |
| 18 | S&F in repair galvannized steel/ stainless steel wire rope of 6mm dia having breaking load approx 2000-2200 kg, 7X19 strand wire rope for lantern carriage in high mast light of 30 m height including fixing with winch drum and necessary clamps including taking down old unsv one complete all as specified and directed. |
| 19 | Supply and fixing air terminal lightning rod copper, 16mm dia, 1 m long as air terminal (lightning rod) on top of high mast including necessary clamps, nuts, bolts and mounting bracket complete all as specified and directed. |
| 20 | Supply and fixing graphite grey powder coated; matt finished pressure diecast aluminium housing designed to act as heat sink for efficient dissipation of heat, Heat resistant toughened glass provided with silicon gasket for efficient Ingress protection, LEDs are provided with secondary polycarbonate lens optics to get optimum optical performance, Constant current LED driver used is specially designed to have built-in surge voltage, open/ short circuit protections. Luminaire is provided with a MS mounting bracket fixed on pressure die-cast aluminium housing for aiming adjustment of 400 watt LED flood light with high power led lumnious efficacy 120 lm/ watt,correlated color temperature 5665K±355K, luminous flux 48000 lm, CRI >70 , Die cast aluminum body with toughned glass along with pennut lens, Impact resistence 08, Ingress protection >66, Built surge protection 4kv and 10kv both will be inbulid in fixture only, Maintenance of lumen output will be minum 50,000 hours as per L70B50 clause, Led Chip will be reputed brand only Osram, Cree, Nichee, Birgdelux, philips only, Power factor will be >0.95 not less than .95. Warranty certificate of LED fitting should be atleast 5 years and same should be prodused to department through OEM directly. Any defects within warranty period will be rectified by contractor and earth connection of each light fitting should be connected to the system earth point either with 3 core cable or though seprate earth cable including taking down old unsv complete all as specified and directed. |
| 21 | Supply of LED Flood light Luminaires of Wattage 200 watt with IP 66 rating. ANSI rated LEDs from reputed makes such as LG/ Nichia, Japan/ Cree, USA/ Bridgelux, USA/ Lumiled USA/ Osram/ Philips should be provided. LEDs shall have optical grade polycarbonate/ PMMA lens to provide street light distribution. The fixture should be made of pressure die cast Aluminium having heat sink in Aluminium Extrusion and clear flat glass. The housing should be with manufacturer's name embossing permanent mark on the die cast housing (Stickering/ screen printing is not acceptable). Control gear shall be provided with die cast aluminium cover for safety. Short Circuit protection should be such that it recovers automatically after fault condition is removed. Integral control gear, IK 07 or above. The fixture should have lumen maintenance of at least 70% at 50000 burning hours at ambient temp of 35 degree C. The driving current for LED should be Max 1A ±10 % .CCT should be 5700 K (+-300K). The efficacy of fixture should be at least 120 lumens/ watt. The power factor of driver should be > 0.9 and the THD < 10% & Internal surge Protection should be 4Kv with external surge protection should be at least 10Kv for better safety of fixture where CRI > 70%. The Fixture should be complete with LED, Driver and all other accessories. Fixture should have discreet LED type and not Chip on board for better heat management system and long life of LED. Own lab certificate calming third party won’t be accepted. Manufacturer to have his own R&D lab for testing & should be approved from ministry of science government of India. vendor should provide third party NABL LM 79 & LM 80. The Lighting Fixtures should be supplied with 3 years Warranty against any manufacturing defect. In case of any failure of LED module or driver or any other part of fixture, same shall be replaced by the vendor during this tenure. All certificates required before supply of material, complete all as specified and directed. |
| 22 | S&F in repair Decorative Post top for 360 degree indirect light 40 watts (Gate Light) with IP 65 Protection gate light (Prismatic), made up of high grade Resistant to Impact and corrosion, and Glare free and better Uniformity with all necessary fixing arrangement including connection complete all as specified and directed. |
| 23 | Supply and fixing in repair of new generation IP 65 LED post-top, 15 watt to 30 watts Gate light family, energy saving environmental friendly, long life aesthetically designed with symmetrical light distribution, spun aluminium landscape luminaire with high power LEDs as light source. Clear cover offers bright illumination for different application, including all fixing arrangement with PVC pipe fitting of suitable size complete all as specified and directed. |
| 24 | S&F in repair of LED 10 Watt Bollard garden lights fittings, integral pole mounted decorative LED post top with IP 65 protection with robust design and efficient light distribution and taking out old defective fittings and all necessary fixing arrangements complete all as specified and directed. |
| 25 | Supply and fix in repairs Post Top Lantern 25 watts fully aluminium cast body finished with polyurethane paint (with prior treatment) with acrylic window cover .Total length 635mm and Max breadth 323mm, heritage look, spigot entry 78mm as per IS 10322 complete incl altration in mounting by welding/ threading/ placing addl GI socket to place lantern truely vertical in position complete all as specified and directed. |
| 26 | S&F in repair Decorative gate light (Moon light) made up of high grade unbreakable polycarbonate material suitable for retrofit LED lamp B22 base with IP 65 protection with robust design and efficient light distribution and taking out old defective fittings and all necessary fixing arrangements complete all as specified and directed. |
| 27 | M&L for PCC 1:4:8, type D2 (using 40mm graded crushed stone aggregate) as in base foundation of the pole, complete all as specified and directed. |
| 28 | M&L for PCC 1:3:6, type C2 (using 40mm graded crushed stone aggregate) as in foundation and mass filling for poles, stays etc. complete all as specified and directed. |
| 29 | M&L for PCC 1:2:4 type B1 using (20mm graded crushed stone aggregate) as in foundations, filling and mass/ concretein coping of poles including necessary form work and finishing exposed surfaces complete all as specified and directed. |
| 30 | M&L in repair for Earthing complete with galvanised steel earth plate electrode 60cm x 60cm. x 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to galvanised iron strip 32 x 6mm as earthing lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion |
| 31 | M&L in replacement for Earthing with galvanised steel earth plate electrode 60cm x 60cm x 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to galvanised iron strip 25 x 4mm as earthing lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point including taking down old earthing all as specified or indicated including testing on completion and submission of test report by contractor complete all as specified and directed. |
| 32 | M&L in replacement for earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6mm thick buried directly in ground vertically (earth pit not less than 2.25m deep below ground level) with top edge of the plate not less than 1.50 mtr deep below normal ground level, connecting to GI earth wire 4mm dia by means of bolts, nuts, check nuts, and washers of galvanized iron or steel including 15mm dia. medium grade protection pipe for earth lead complete with charcoal and common salt including watering arrangement with galvanized iron pipe light grade 20mm dia, PCC Chamber, CI frame and cover, MS funnel with wire mesh all as shown in electrical plate No. 3 of SSR Part-I, including excavation and earthwork in any type of soil/ strata and testing on completion including taking down old unsv complete all as specified and directed. Note:- GI earth wire 4mm dia and 15mm dia protection pipe up to 7.5 mtr from earth plate is deemed to be included in rate quoted. |
| 33 | M&L in replacement for Earthing complete with galvanised copper plate 60 x 60cm x 3.15mm thick electrodeand 20 x 3mm copper strip asearthing lead, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, all as shown in electrical Plate No. 3 connected to earthing test point all as specified or indicated including testing on completion, complete all as specified and directed. |
| 34 | Material & labour in replacement for Advance encapsulated compound based Chemical earthing CPRI tesed maintenance free, pipein -pipe technology upgraded (Zinc & Alloy coated). Zinc & Alloy coated (80 -100) microns with pure zinc (99.9%) & Alloy coating (200-250) microns. Earthing system conforming IS 3034. The outer and inner pipe should be 76.2mm and 41.9mm dia respectively of 3 mtrs long zinc coated with additional special alloy coating 300mm on top side for additional protection of the terminal. The annular space between the pipes to be filled up with Compact fill (CF) (Crystalline Conductive) mixture which should be machine pressed in the pipes not disintegrate or collapse when outer pipe corrodes. The inner pipe should be extended with terminals for connectivity. The job includes boring of 300mm dia bore up to 5.5 mtr depth in any type of strata/ soil for placing/ lowering the pipe in pipe electrode, filling of pure conductolite back filling compound (BFC Conductolite) having excellent moisture retaining capacity in 300mm bore all around the electrode min 4 bags of 25 KG per pit per unit.The earth pit should be provided with a FRP earth pit cover for protection and safe guard of terminals. The material of earth electrode should have good electrical conductivity & anti corrosion property in wide range of soil conditions. The job also include M&L for in PCC(1:3:6) type C-1 around the FRP cover for support and foundation and colouring the PCC work with desired colour. complete all as specified and directed.Make : ASHLOK ( Model ASEEL-39 AC 3 mtr length 76.3mm diaNote:- (i) Design of earth electrode should be of pipein-pipe technology.(ii) Contractor have to submit literature of earth electrode and get the make approved of GE before procurement.(iii) The earth electrode shall be CPRI tested to withstand short current test for 60 KA rms for 1.0 second and 150 KA for peak current.(iv) Contarctor has to fill pure back fill compound all around the earth electrode in 300mm bore up to full depth of bore.(v) Copper strip will be laid below 20 cm from ground level and connecting the test point through plinth protection using HDPE pipe for protection, necessary cost of repair to plinth protection and brazing and welding deemed to be included in the item.(vi) Contarctor shall submit the test report of earthing after satisfactorily completion.(vii) Contractor shall remove and disposed off the soil excavated from boring and clear the site before completion of work. |
| 35 | S&F in replacement of earth continiuty conductor or main earth lead fixed to wall on batten or recess or chases or burried in ground or drawn in conduit/ pipe or fixed to poles or any other indicated situation for earthing as required of size 32 x 6mm GI strip complete all as specified and directed. |
| 36 | All as per Srl item No. 35.00 above, but 25 x 4mm galvanised iron strip complete all as specified and directed. |
| 37 | All as per Srl item No. 35.00 above, but of size 25 x 3mm aluminium strip complete all as specified and directed. |
| 38 | S&F in replacement of earth continiuty conductor or main earth lead fixed to wall on batten or recess or chases or burried in ground or drawn in conduit/ pipe or fixed to poles or any other indicated situation for earthing as required of size 4mm dia galvanised iron or steel wire complete all as specified and directed. |
| 39 | Supply and fix in replacement air termination, single pointed aluminium rod 12mm dia and 300mm long complete all as specified and directed. |
| 40 | Supply and fix including replacement of old existing insulators for earthing systems/ Lightning arrestor and for GI/ copper strip from wall and recess, by elapped red DMC earthing GI strip insulators including fixing them by nut and bolts properly, for electrical installation and for lightning arrestor for (GI strip) of any size installation fixed on wall and recess complete all as specified and directed. |
| 41 | S&F in replacement mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, n exc 5cm long complete all as specified and directed. |
| 42 | M&L in repair for GI Pipe Light grade for cable protection of dia 50mm complete all as specified and directed. |
| 43 | All as per Srl item No. 42.00 above, but of size 40mm, complete all as specified and directed. |
| 44 | M&L in repair outdoor waterproof and weather proof (IP 65) flexible LED rope light in tricolour (orange, white, Green) with plug, driver, and accessories suitable for tree/ road/ garden decoration, fixing of rope light with plastic clips, cable ties, binding wire including proper dressing including connecting with 1.5 Sqmm 2 core flexible copper cable at site, complete all as specified and directed. Please Enable Macros to View BoQ information |