| 1 | Taking down chowkats or frame of any description exc 1.5 Sqm each and n.exc 4Sqm (without taking off shutters from the frames) & remove off the premises complete all as specified and directed. |
| 2 | Taking down Shutters of any description exc 1 sqm but n. exc 2 sqm each of any description complete all as specified and directed. |
| 3 | Taking down chowkats or frame of any description n.exc. 1.5 Sqm each (without taking off shutters from the frames) & remove off the premises complete all as specified and directed. |
| 4 | Taking down Shutters of any description n. exc 1 sqm each of any description complete all as specified and directed. |
| 5 | Resecuring or easing and adjusting door shutters of any size and any description without taking down shutter from frame complete all as specified and directed. |
| 6 | S&F Pressed steel door frame for single door, size 105 x 60 x 1mm with one rebates incl necessary fixing lugs, hinges, lock strike plate, holdfast (size 25mm x 3mm) of length 30 cm) etc., including Cutting holes in brick walls built in cement mortor for inserting holdfasts and making good dismantled portion in cement mortor 1:3 or cement concrete 1:2:4 Type B-1, depth of embedded portion of holdfasts exc. Half brick but not exc. One brick from the face of the jamb intl the wall complete all as specified and directed. |
| 7 | S&F Pressed steel door frame for single door, size 165 x 60 x 1mm with one rebates incl necessary fixing lugs, hinges, lock strike plate, holdfasts (size 25mm x 3mm) of length 30 cm) etc., including Cutting holes in brick walls built in cement mortor for inserting holdfasts and making good dismantled portion in cement mortor 1:3 or cement concrete 1:2:4 Type B-1, depth of embedded portion of holdfasts exc. Half brick but not exc. One brick from the face of the jamb intl the wall complete all as specified and directed. |
| 8 | M&L for PCC 1:2:4 type B0 (12.5mm graded) aggregate for filling in pressed steel door framed complete all as specified and directed. |
| 9 | S&F Second class hard wood plain, solid, straight chowkats and frames, wrought, framed, rebated on the solid, rounded or chamfered, put together with glue pinned at joints complete all as specified and directed. |
| 10 | S&F 35mm thick second class hardwood rail and style, Plain, framed, panelled shutters Plain framed, panelled shutter (two panel) with lock rail and panel of 9 mm B.W.P. commercial ply or 12mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS : 1003 (Part I), kiln seasoned and chemically pressure treated complete all as specified and directed. |
| 11 | S&F Solid single PVC door frame of size 50mm x 47mm made out of 5mm single side prelam PVC sheet used instead of Plain colour PVC sheet reinforced with M.S. tube, edges will be painted to match with prelam sheet suppling & fixing in opening as per specification & drawing including all fixtures shown on drawing. |
| 12 | Factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of M.S tubes for top & bottom rails. M.S frame shall be covered with heat moulded plain colour PVC 'C' channel having a PVC sheet strip if 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bootom rail on either side & as gap insert for top rail and bottom rail; Panelling of plain colour PVC sheet to be fitted in the MS frame welded/ sealed to the stiles. & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling and fixing in the frame at site complete as per specification & drawing |
| 13 | S&F 35mm thick Flush shutters, solid core construction, with block board core & plywood face panels, commercial type on both sides complete all as specified and directed. |
| 14 | S&F 35mm thick 2nd class hard wood glazed and skeleton shutters open rebated and prepared to receive glass gauge etc with cut and mitred beads for securing glass etc size of member of shutter as specified in SSR Pt-1 section 8 and clause 8.24 (a) complete all as specified and directed. |
| 15 | S&F powder coated alumiuium frame for doors window, ventilator with one or more rebates including joining cleat for fixing etc complete all as specified and directed. |
| 16 | S&F Powder coated Aluminium ventilator, fixed type without sash bar, aluminum section weighing 0.55 Kg/ RM including necessary joining cleats, glazing clips, rubber packing, anodised aluminum snap beading, screws etc. including 50% of bottom portion is fixed with 4mm pin headed glass and balance 50% of top portion is fixed with 4mm thick pin headed glass lowers and cover with 0.36mm dia stainless steel wire mesh at top portion complete all as specified and directed. |
| 17 | S&F powder coated alumnium (minium thickness of powder coating 50 micron) for shutters of doors, window & ventilator sliding, side hung type without sash bars, aluminium sections weighing 0.55 kg/m including poviding and fixing hinges/ pivots any making provision for fixing of fittings whereever required incuding the cost of EPDM rubber/ neoprene gasket required (fittings shall be paid for separately) wth extruded built up standard tubular sections/appropriate Z sections and other secitons of approved make conforming to IS:733 and IS:1285, fixing with dash fasteners of required dia and size, incl necessary filling up the gapsat junctions, i.e at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Alumiuium sections shall be smooth, rust free, straigth, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, CP brass/ stainless steel screws incl handles, pegstay, locking arrangements etc complete as per architechtural drawings and the directions of Engineer-in-charge complete all as specified and directed. |
| 18 | S&F 150mm size aluminium, anodised barrel tower bolt of extruded section complete all as specified and directed. |
| 19 | S&F 125mm size aluminium, anodised barrel tower bolt of extruded section complete all as specified and directed. |
| 20 | S&F 300mm length, aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy complete all as specified and directed. |
| 21 | S&F 120mm size, butt hinges, heavy weight, cold rolled mild steel complete all as specified and directed. |
| 22 | S&F100mm size, butt hinges, medium weight, cold rolled mild steel complete all as specified and directed. |
| 23 | S&F 150mm size extruded aluminium alloy handles, fabricated type complete all as specified and directed. |
| 24 | S&F 125mm size extruded aluminium alloy handles, fabricated type complete all as specified and directed. |
| 25 | M&L for Preparation of new wooden surfaces over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed. |
| 26 | S&F in repair Stainless steel curtain rod/ rail 25mm dia medium weight with premium quality incl SS brackets with decorative caps as approved by Engr-in-Charge complete all as specified and directed. |
| 27 | Hacking out old broken glass (any thickness, size, quality or description) from metal frame incl punching or drilling out old glazing pins/ spring clips and providing and fixing new ones complete all as specified and directed. |
| 28 | M&L for 4mm thick sheet glass, ordinary quality and glazing with oil putty and fitted in wooden/ steel window in square n exc 0.5 Sqm in each pane complete all as specified and directed. |
| 29 | M&L for 4mm thick sheet figured glass, pin headed type and glazing with oil putty in square n exc 0.5 Sqm in each pane complete all as specified and directed. |
| 30 | S&F in repairs Galvanised mild steel wire cloth, 0.63mm nominal dia of wire and average width of aperture 1.40mm and fixed with tinned tacks, or galvanised wire staples complete all as specified and directed. |
| 31 | M&L in fixed in repairs 18/19mm thick Prelaminated particle board, interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed with screws to timber frame work complete all as specified and directed. |
| 32 | S&F in repair PVC water tank covers premium quality fitted to tank. Make - Syntex or equivalent water tanks of Cap 500 ltrs to 1000 ltr complete all as specified and directed. |
| 33 | S&F 1000 litres capacity Rotational moulded polyethylene water storage tanks (Cylindrical vertical with closed top) hoisted and fixed in position including taking down old unsv PVC water tank in SSR Part-I, complete all as specified and directed. |
| 34 | S&F 500 ltr capacity rotational moulded polythyiene water storages tanks (cylindrical vartical with closed top) hoisted and fixed in position including taking down old unsv PVC water tank in SSR Part-I, complete all as specified and directed. |
| 35 | Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed. |
| 36 | M&L for Framed work such as grills, gratings, etc. with ends of bars shouldered and/ or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified and directed. |
| 37 | Taking up or down 15mm bore steel tubing and connections, complete all as specified and directed. |
| 38 | S&F of CPVC 20mm outer dia pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ ceiling or laying in floors incl taking up or down steel tubing pipes complete all as specified and directed. |
| 39 | Taking up or down 20mm bore steel tubing and connections, complete all as specified and directed. |
| 40 | S&F of CPVC 25mm outer dia pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ ceiling or laying in floors incl taking up or down steel tubing pipes complete all as specified and directed. |
| 41 | S&F of CPVC brass elbow (3/4\\" x ½\\") for 20mm outer dia CPVC pipe complete all as specified and directed. |
| 42 | S&F of CPVC Male Brass Threaded Adaptor (MTA/ MBTA) for 25mm outer dia pipe complete all as specified and directed. |
| 43 | S&F of CPVC Tank Adaptor for 25mm outer dia pipe complete all as specified and directed. |
| 44 | S&F of CPVC union for 25mm outer dia pipe complete all as specified and directed. |
| 45 | S&F in repairs 18mm thick factory made PVC sheet one side pre-laminated sheet kitchen cabinet/ cupboard shutter. The 18mm thick sheet shutter bent at 90 degree and finish all edges at level for marking edge lipping bending for 0.5mm thick PVC sheet lipping at all four edges using bonding tape etc complete all as specified and directed. |
| 46 | S&F in repairs factory made PVC shelf/ partition of required size consisting of panel of 18mm thick required size consisting of panel of 18mm thick celuka PVC ply and for supporting the hold of shelf/ partition and shall provided 3 edges in size 18mm x 18mm as per required lenght the front side of the edge visible in the front of the shelf/ partition to be edge lipped by 18mm width x 1mm thick PVC sheet of density 600 kg/cum manufactured by ISO 9001-2015 Certified Company, using solvent cement etc. complete all as specified and directed. |
| 47 | S&F in repairs factory made PVC shelf/ partition of required size consisting of panel of 12mm thick required size consisting of panel of 12mm thick celuka PVC ply and for supporting the hold of shelf/ partition and shall provided 3 edges in size 18mm x 18mm as per required lenght the front side of the edge visible in the front of the shelf/ partition to be edge lipped by 12mm widht x 1mm thick PVC sheet of density 600 kg/cum manufactured by ISO 9001-2015 Certified Company, using solvent cement etc. complete all as specified and directed. |
| 48 | S&F stainless steel shelf closing hinges 75mm size for PVC door shutters complete all as specified and directed |
| 49 | S&F 50 x 15mm size magnet door catcher for closing for PVC door shutter complete all as specified and directed. |
| 50 | S&F 100mm size MS mat/glossy finish handle complete all as specified and directed. |
| 51 | S&F modular type stainless steel cutlery basket size 20 x 19 x 4 inches (dia of wire not less than 3.00mm) of any shape withside sliding roller clip and silding rails on both side fixed with steel screws incl all fixing arrangements complete all as specified and directed. |
| 52 | All as per Srl item No. 51.00 above but cup and saucer basket size 20 x 17 x 4 inches complete all as specified and directed. |
| 53 | All as per Srl item No. 51.00 above but plain basket size 20 x 19 x 6 inches complete all as specified and directed. |
| 54 | All as per Srl item No. 51.00 above but grain basket size 20 x 17 x 6 inches complete all as specified and directed. |
| 55 | All as per Srl item No. 51.00 above but thali basket size 20 x 19 x 8 inches complete all as specified and directed. |
| 56 | All as per Srl item No. 51.00 above but plain basket size 20 x 17 x 8 inches complete all as specified and directed. |
| 57 | Dismantling boarding, any description, fixed in any position with screws complete all as specified and directed. |
| 58 | Dismantling of Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified and directed. |
| 59 | S&F Pre- painted galvalume aluminum zinc coating GI based profile steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa, hot dip alloy of 55%, Aluminium 43.5%, Zinc 1.5%, Silicon and finished with resin coat on both surfaces as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed. |
| 60 | Dismantling of timber scantling as fillets, rails, posts, rafters, purlins, any section & any description complete all as specified and directed. |
| 61 | S&F Steel work in tubular trusses, purlins etc including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161-1979 grade St.-240etc complete all as specified and directed. |
| 62 | Taking down cement or cement lime plaster of any description including racking out joints, hacking for keys, scrubbing down with water etc, complete all as specified and directed. |
| 63 | M&L for Rendering 15mm thick on fair faces of concrete/ brick interior surfaces in cement mortar 1:6 as per manufacturer's instruction, finished fair and even without using extra cement complete all as specified and directed. |
| 64 | M&L for Rendering 5mm thick on fair faces of brick work or concrete surfaces of ceiling, chajja in CM 1:3 surface finished even and smooth without using extra cement complete all as specified and directed. |
| 65 | M&L for preparation of newly plastered surfaces of walls and applying two coat of distemper oil emulsion incl priming the surface and incl one coat of wall putty complete all as specified and directed. |
| 66 | M&L for preparation of newly plastered surface of ceiling surface and applying three coats of white wash on ceiling complete all as specified and directed. |
| 67 | S&F, solid PVC wall panelling consisting of 5mm thick wood grain painted PVC sheet fillet of wight 35mm inclusive of solvent cement and fixing at site on PVC frame including dismantling old wall panelling any type, complete all as specified and directed. |
| 68 | S&F 30mm thick 2nd class hard wood glazed and skeleton shutters open rebated and prepared to receive glass gauge etc with cut and mitred beads for securing glass etc size of member of shutter as specified in SSR Pt-1 section 8 and clause 8.24 (a) complete all as specified and directed. |
| 69 | M&L for providing and injecting chemical emulsion for Post Constructional Antitermite Treatment along external wall where the apron is not provided using chemical emulsion at the rate of 7.5 litres per sqm of the vertical surface of the sub-structure to a depth of 300mm including excavating channel along the wall and rodding etc. complete all as specified and directed. |
| 70 | M&L for points of contact of wood work by chemical emulsion (in oil or kerosene based solution) @ 0.5 litre/ hole by drilling 6mm dia holes at a downward angle of 45 degree at 150mm centre to centre and sealing the same etc complete all as specified and directed. |
| 71 | M&L for applying Damp Proof chemical fibre reinforced, elastomeric coating course to horizontal or vertical surfaces including cleaning the existing surface complete all as specified and directed. |
| 72 | S&F in repair Vitreous china, (Single piece with flushing cistern) wash down water closet pan (pedestal pattern), white, including plastic water closet seat cover, closed pattern with flat bottom, connection to drain (or outgoing pipe) and to flushing pipe, antisiphonage pipe etc complete all as specified and directed. |
| 73 | M&L for welding in repairs n. exc. 2.5 cm in length on metal thickness exc. 6 mm but n. exc. 9mm complete all as specified and directed. |
| 74 | Supply & providing water proofing roof treatment with polymeric standard water proofing membrane, Aquaflex manufactured by M/s Bengal Bitumen, MULTIPLAS STANDARD, manufactured by STP TEXAS Ltd/ Hyperplas manufactured by IWL Ltd having 10 years gurantee for water tightness including taking down old water proofing treatment and removing rubbish to a distance not exc. 100 metres complete all as specified and described as under:-(a) Preparation of RCC roof surface and applying one coat of polymeric modified bitumen 85/25 @ 1.2Kg/Sqm over a coat of polymeric primer @ 0.30 Kg/sqm including cleaning surface all as per manufaturer's specification complete all as specified and directed. (b) Supply & providing water proofing with 3mm thick APP polymeric proofing membran of 3Kg/Sqm HYPERPLAS STANDARD/ MULTIPLAS STANDARD consisting of 100micron HMHDPE film centre core including coating the surface with compatible primer and torch application of membrane with 10cm overlaps as required thereof, complete all as specified and directed. (c) Aluminium bituminous paint @1.10 Kg/Sqm shall be applied over the APP membrane surface.Note:- The work of water proofing treatment shall be got executed through expert team of manufacturers or authorised applicator of manufacturer. |
| 75 | M&L for 10mm thick screed bed on concrete surfaces in CM (1:3) finished even and smooth without using extra cement complete all as specified and directed. |
| 76 | M & L for Elestomeric Water proofing on roof/ wall with the follwing steps:-STEP - I. Firstly to cleain the existing surface and make the surface dust free. STEP - II. Crack more then 0.5mm the opening of crack in V grove and filling with epoxy mortor. STEP - III. Initial coat (mixed 1/2 liter of water in 1 liter of Roof/ wall seal of Asian paint/ PIDILITE/ STP/ FOSROC/ ACC/ L&T/MARUIT) as a primer (Area cover 1 liter=9-10 sqmtr) STEP - IV. After six hours of primer, apply first coat (one coat) of Asian paint/ PIDILITE/ STP/ FOSROC/ ACC/ L&T/ MARUIT. roof/ wall seal in a particular direction without mixing of water. Now left it for six hours (Area cover 1 liter= 1.2 sqmtr). STEP - V. After again six hours of first coat and apply the second coat of Roof/ wall seal in a other direction without mixing of water (Area cover 1 liter= 1.2 sqmtr). Now left it 24 hours. complete all as specified and directed.Note:- The work of water proofing treatment shall be got executed through expert team of manufacturers of authorised applicator of manufacturer. Please Enable Macros to View BoQ information |