Name of Work:- Construction of MRF Platform and Partition work at MR 5 C & D Plant in ward no 4
Sl. No.
Item Description
1
Boring,ProvidingandinstallingcastinsitusingleunderreamedpilesofspecifieddiameterandlengthinM20cementconcrete,excludingthecostofsteelreinforcementbutincludingthecostofboring,cementconcrete,allcomplete.(Lengthofpileforpaymentshallbemeasured upto to the bottom of pile cap) :
2
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering All work up to plinth level. Cement concrete grade M-10 (Nominal Mix) with 40 mm maximum size of stone aggregate
3
Brick work will well burnt open bhatta bricks crushing strength not less than25kg/cm² and water absoption not more than 20% in foundation and plinthIn cm 1:6.
4
Providing and laying in position specified grade reinforced cement convrete excluding the cost of centering and shuttering, finishing and reinforcement - All work up to plinth level. Cement concrete grade M-20 (Nominal Mix) with 20 mm maximum size of stone aggregate
5
Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete. Thermo-Mechanically Treated Bars
6
Centering and shuttering including strutting, propping etc.and removal of form for : Foundations, footings, bases of columns, etc. For mass concrete.
7
18mmcementplasterintwocoatsunderlayer12mmthickcementplaster1:5(1cement:5coarsesand)finishedwithatoplayer6mmthick cement plaster 1:4 (1 cement: 4 fine sand).
8
Providing and Laying Cement Concrete Grade M-10with 40 mm graded crushed stone aggregate, spreadingthe concrete by shovels mixing shall be in mechanicalmixer, compacting by use of pin/plate/screed vibratorsincluding form work by strong steel girders fixed byspikes.
9
Providing and laying Cement Concrete grade M-20 (Nominal mix 1:1.5:3)with 20 mm graded crushed stone aggregate, mixing shall be inmechanical mixer, laying with paver compacting by use of pin, plate /screed vibrators including form work by strong steel girders fixed byspikes, separation membrane 125 micron thick, i/c cutting of joints @ 4 to5 m interval & filling it with hot applied bituminous sealant (without dowelbars). (max. thickness 20cm)
10
Wallpaintingwithplasticemulsionpaintofapprovedbrandandmanufacture to give an even shade: Two or more coats on new work Please Enable Macros to View BoQ information