| 1 | SITC of 82.5 kVA Diesel GENERATOR |
| 2 | OD114392/2024-2025:Supply, Conveyance, Installation, testing and Commissioning of 82.5 kVA DG set withintegral acoustic enclosure confirming to CPCB 4 and latest amendments with accessories asper the technical details given below :- i. Engine a. Make of Engine : As per Specified in theList of Materials b. Type of Engine : Diesel Engine c. No. of Cylinders : Suitable to develop therequired BHP as per manufacturers standard d. Method of Cooling: Water Cooling (withradiator) e. Aspiration : Tubro charged after cooled f. Design : Suitable for generator setapplication g. Output : BHP ratings specified by the respective manufacturers capable ofdelivering the required power for alternator. ii. Standard accessories with Diesel Engine a.Flywheel housing and flywheel to suit single bearing alternator (Close coupled arrangement) b.Air Cleaner c. Coolant Kit d. Fuel Pump e. Electronic governor with solid state potentiometeraccepting digital pulse input from PLC(backed with mechanical governor supplied as standardwith the set by the manufacturer) f. Fuel filter g. Lubricating Oil filter h. Residential typeexhaust silencer iii. Engine Instrument Panel a. Starting switch with key or button b.Lubricating oil temperature gauge c. Lubricating oil pressure gauge Water temperature gauge e.RPM Indicator with hour meter f. Battery charging ammeter iv. Safety Controls for Engine a.Trip for low lubricating oil pressure b. Trip for high water temperature c. Providing necessarywarning system and other safeties as contemplated in relevant ISS d. Fuel shunt off facility atover speed. iv. Fuel Pipe: Oil resistant flexible hoses 25mm dial or nearest size MS pipe as permanufacturers requirement for fuel line extension with regulator valve. v. Alternator a. Make :As per Specified in the List of Materials . b. Type : Self exited and self regulated c. Capacity :82.5 kVA d. System of Voltage : 3 phase, 415V e. Speed : 1500rpm f. Voltage regulationband : +1.00% of rated voltage g. Insulation : Class F/H h. AVR : AVR shall be provided with amotorized or solid state potentiometer. i. IP rating of enclosure : IP 23 j. Waveform distortion :No load < 1.5%, non- distorting, balanced Linear load <5 Total harmonic factor :Better than 2% Standard control panel with suitably rated 4 pole MCCB .m.12V,15A AutomaticBattery charger suitable for required Ah Battery, having . Full protection against batteryovercharging & reverse polarity. Over voltage, overload & short circuit protection,reverse battery protection The alternator should confirm to IS 4722. Routine tests as perrelevant ISS shall be conducted and test reports of the same shall be furnished at the time ofdelivery. vii. Fuel tank. Integral type fuel tank of adequate capacity with 20 litters Diesel viii.Battery: Required number of suitably rated fully charged battery with leads and terminals asrequired as per manufacturers requirement. ix Operation manual, service manual, list of sparesetc x. Acoustic Enclosure with CPCB Norms 4 a. The DG set shall be supplied along withspecially designed, company fabricated (to be fabricated in the same company from where theDG set is delivered) acoustic enclosure to meet the CPCB norms 4 ,. b. Sufficient space andclearance shall be maintained inside the enclosure to have optimum serviceability. c. Air inletlouvers shall be designed in such a way as to operate the set at rated load even at 50 degreeCelsius enclosure temperature. d. The enclosure shall be with UV resistant powder coatingcapable to withstand extreme environment. e. Hardware used shall be of only stainless steelmake. f. Insulation material shall conform to IS 8183 specifications for better attenuation. xi.Documents to be supplied. a. Engine manual. b. Spares parts book c. Warranty certificate d.Alternator manual & test certificate 1 set control wiring drawing xii. Installation It shall beinstalled in the pre-constructed concrete bed complying to relevant IS standards, IErules and as per the direction of the departmental officials. xiii. Testing and Commissioning :xiv. During the 3 year Guarantee period comprehensive maintenance including all services periodic maintanance as per manufacture recommendation and repairs shall be arranged from date ofcommissioning . |
| 3 | 90.14.5:Supply and fabrication conveyance and installation of angle iron frame work for wall mounting panel board |
| 4 | OD110579/2024-2025:Supply and providing the following size of B class MS pipe conforming to relevant IS specifications complete with heavy guage specials such as bends, flanges etc welded and fixed at appropriate locations, providing cork sheet in between the flanges at the joints, bolting the flanges together, painting the pipe, flange etc with 2 coats of heat resistant paint suitable for outdoor applications, fixing the pipe firmly with fabricated structure/wall/any other mechanical support etc as required.- 80 mm dia B class MS pipe as extended exhaust pipe. |
| 5 | 14.1:Excavation for foundation in soft soil including dressing of sides and ramming of bottoms, lift upto 1.5 m including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 metres. |
| 6 | 14.7:Providing and laying in position cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) in foundation of pump, DG set etc including form work etc as required. |
| 7 | 14.11:Providing brick work (in width 225 mm or more) with F.P.S. bricks of class designation 7.5 in cement mortar 1:4 (1 cement : 4 coarse sand) at all levels. |
| 8 | OD110580/2024-2025:Providing 15mm thick cement plaster of mix 1;4 (1 cement;4 fine sand) at all levels |
| 9 | OD42243/2026-2027:Dismatling the existing 15 kVA DG set and AMF pannel after disconnecdting cable connections ,earth connections , dismantling MS exhaust pipe etc. Lifting and placing to the same to suitable location as required. |
| 10 | 5.4:Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. |
| 11 | 90.12.7.31:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 95 sq mm |
| 12 | OD43674/2026-2027:Supply, laying and clamping of 1 no. 2.5 sqmm 6 core PVC/ XLPE insulated armoured controlcables with copper conductors for working voltages up to and including 1100 V conforming toIS 1554 part I 1988 for PVC and IS 7098 Part I for XLPE grade of the following sizes usingclamps noted along with the cables, spacing of clamps not exceeding 60cms, making good thedamages , colour washing etc. as required. |
| 13 | 9.1.24:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 95 sq. mm (45mm) |
| 14 | 9.1.1:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.2 X 6 sq. mm (19mm) |
| 15 | 90.16.3.9:Supply and clamping the following size of strips on surface of wall/ parapet/ existing cable tray using clamps fabricated from 20 X 3 mm GI flat duly painted or heavy duty GI spacer saddles spacing of clamps not exceeding 1 m, making good the damages, colour washing etc. as required ( for horizontal run)25 x 3 mm copper strip |
| 16 | OD43004/2026-2027:Supply and laying 25x6 mm GI strips laid 0.60 m below ground level including excavatingtrench of suitable size and refilling etc. as required |
| 17 | OD110582/2024-2025:Supply and providing 25x3mm brass nut and bolt etc. as required. |
| 18 | OD110583/2024-2025:Supply and providing test joint for the earthing system using 2Nos of the following sizes of strips including cutting and bending to shape, drilling necessary holes and fixed to the watering pipe ete as required. 2 x 25 x 3 mm GI strip |
| 19 | OD110584/2024-2025:Supply and providing earth lead from the test joint to the earth electrode using the followingsizes of conductors/strips including cutting,drilling necessary holes(in case of strip) and fixingfirmly with plate test joint etc as required.25 mm x 3 mm G.I Strip. |
| 20 | 1.17.12:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 2.5 sq. mm |
| 21 | 1.21.1:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm |
| 22 | 1.21.2:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm |
| 23 | 90.10.1.3:Supply & Fixing the following types/ sizes of boxes suitable for modular accessories in surface/ recess including making good the damages, colour washing etc as required (RoHS compliant )3 module moulded plastic box on surface |
| 24 | 1.28.2:Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.3 Module |
| 25 | 1.24.3:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch |
| 26 | 1.24.5:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet |
| 27 | OD305758/2024-2025:Supply and Installation of ABC stored pressure type 6 Kg capacity Fire Extinguisher with pressure indication complete conforming to IS 15683 with initial charging and Installation brackets etc as required |
| 28 | OD110592/2024-2025:Supply and fixing First Aid Chart |
| 29 | OD43696/2026-2027:Supply and providing 2mm thick Elastomeric fire retardent insulating mat as per IS 15652/2006 to withstand 3.3 KV dielectric strength. |
| 30 | 90.12.5.3:Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.2 core 10 sq mm |
| 31 | 90.12.7.3:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.2 core 10 sq mm with factory made clamp |
| 32 | 9.1.2:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.2 X 10 sq. mm (19mm) |
| 33 | 9.1.33:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 16 sq. mm (28mm) |
| 34 | 90.12.7.41:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 16 sq mm with factory made clamp |
| 35 | 1.17.21:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 4 sq. mm |
| 36 | 1.17.6:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.6 x 1.5 sq. mm |
| 37 | 1.17.24:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.6 x 4 sq. mm |
| 38 | 90.16.1.2:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required2.65 mm copper conductor (12 SWG) |
| 39 | 90.16.5.2:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.2.65 mm (12 SWG) |
| 40 | 90.12.10.2:Supply & laying of DWC pipe in ordinary soil 0.75m below ground level including excavation50/38 mm or nearest size |
| 41 | 90.11.1.15:Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required6 way (8+18) - double cover TPN vertical DB with provision for fixing 4P MCB / Isolator/ RCCB/ RCBO as incomer and SP/ TP MCB as outgoing (IP 42/43) |
| 42 | 90.11.1.10:Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required4 way (8+12) - three phase double cover (IP 42/43) |
| 43 | 2.3.1:Supplying and fixing following way, single pole and neutral, sheet steel, MCBdistribution board, 240 volts, on surface/ recess, complete with tinned copperbus bar, neutral bus bar, earth bar, din bar, interconnections, powder paintedincluding earthing etc. as required. (But without MCB/RCCB/Isolator)6 way, Double door |
| 44 | 2.10.1:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, \\"\\"C\\"\\" curve, miniaturecircuit breaker suitable for inductive load of following poles in the existing MCBDB complete with connections, testing and commissioning etc. as required.Single pole |
| 45 | 2.10.4:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, \\"\\"C\\"\\" curve, miniaturecircuit breaker suitable for inductive load of following poles in the existing MCBDB complete with connections, testing and commissioning etc. as required.Triple pole |
| 46 | 2.12.1:Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps |
| 47 | 2.13.1:Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps |
| 48 | 2.15.1:Supplying and fixing following rating, four pole, (three phase and neutral), 415volts, residual current circuit breaker (RCCB), having a sensitivity current 30milli Amperes in the existing MCB DB complete with connections, testing andcommissioning etc. as required.25 amps |
| 49 | 2.11:Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. |
| 50 | OD42184/2026-2027:Supply and fixing 16A 4 Way Bakelite Connector in exixing MS box and giving connection as required. |
| 51 | 1.22.7:Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc as required.200 mm X 150 mm X 60 mm deep |
| 52 | 2.13.2:Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps |
| 53 | 2.14.1:Supplying and fixing following rating, double pole, (single phase and neutral),240 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 amps |
| 54 | 2.15.3:Supplying and fixing following rating, four pole, (three phase and neutral), 415volts, residual current circuit breaker (RCCB), having a sensitivity current 30milli Amperes in the existing MCB DB complete with connections, testing andcommissioning etc. as required.63 amps |
| 55 | 90.14.1.2:Fabrication, supply, conveyance, installation testing and commissioning of floor or wall mounting, dust and vermin proof, cubicle type MV panel board comprising of the following components/ devices & complying to IS 8623.Fabrication of fully partitioned, dust and vermin proof enclosure for panel assembly as per form 4 of IS 8623 (with latest amendments) using CRCA sheet as per approved design and requirement, with front and rear access facility, bus bar chambers, hinged doors for all switch gear compartments, earthing the doors using 4 sq mm braided copper conductor, providing necessary cut-outs for mounting meters, relays, indication lamps, bus bar interconnection etc, detachable covers for bus bar chamber and cable alley, powder coating the assembly after subjecting to 7 tank process etc as required. CRCA sheet alone be used for the fabrication. Angles/ flats/ slotted angles etc shall not be used for the fabrication of panel assembly. The measurments will be taken the area of the complete sheets used for panel board including partitions, folding, shrouding etc.Supply and fabrication of MV panel board using 1.6mm CRCA sheet, powder coated (excluding base frame) |
| 56 | 90.14.2.1:Supply and providing 2mm SMC sheet as shrouding for bus interconnection / terminations etc. including required nut & bolt etc. |
| 57 | 2.2.14:Providing and fixing following rating and breaking capacity MCCB withthermomagnetic release and terminal spreaders in existing cubicle panel boardincluding drilling holes in cubicle panel. making connections. etc. as required.125 Amp, 36 KA |
| 58 | OD42142/2026-2027:Supply and fixing 125A, 4 pole Automatic Transfer Switch (ATS) with auto / mannual operation without enclosure with DGON/OFF Module in the existing panel board and giving connection etc asrequired . (Make LK CK90161BATS) |
| 59 | 90.14.11.12:MCCB AccessoriesSupply and fixing shunt release for all voltage range up to 630A. |
| 60 | 90.14.11.13:MCCB AccessoriesSupply and fixing rotary handle, External type (including BUC handle with door interlock ) in the existing MCCB of rating up to 250 A |
| 61 | 90.14.11.2:MCCB AccessoriesSupply and fixing one number earth fault Relay up to 125A to 200A with CBCT. |
| 62 | OD42995/2026-2027:Supply and fixing of 120/5 A, 5 VA, accuracy class 1, Resin Cast Metering CT |
| 63 | OD43002/2026-2027:Supplying and fixing 2 A, 240/415 volts, Single pole "C" curve, miniature circuit breaker in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 64 | OD42996/2026-2027:Supply and fixing of Blue colour LED indicator, AC/DC, 22.5 mm cut out dia |
| 65 | OD42997/2026-2027:Supply and fixing Digital Multifunction meter to read: V, A, F, 3 phase accuracy class 1 |
| 66 | OD42998/2026-2027:Supply and fixing of Red, Green, Black, Yellow, Orange colours LED indicator, AC/DC, 22.5 mm cut out dia |
| 67 | OD42999/2026-2027:Supply and fixing of Danger 415 V, 150 x 100 mm aluminium anodised legend plates as required. |
| 68 | 90.14.3.2:Supply and providing heavy duty 'A' section neoprene gasket in the panel boardU' section rubber beeding suitable for 1.60/ 2.00 mm sheet |
| 69 | OD113216/2024-2025:Supply and fixing 160A, HRC Fuse with HRC Fuse link with connections, in existing meter board |
| 70 | OD113231/2024-2025:Supplying and fixing 100 A, 2 Way neutral links mounted on DMC/SMC base with connections, in existing meter board |
| 71 | OD113234/2024-2025:Supply and fixing 40 mm dia 6Kgff/cm2 PVC pipe including fixing the pipe with clamp/clips at 60cm spacing. etc as required (For Service Pipe) |
| 72 | OD113235/2024-2025:Supply and providing suitable Iron Hook grouted on wall for binding the service wire |
| 73 | OD305744/2024-2025:Charges for Preparation of electrical /fire drawings in A3 sheet as per requirements for submitting electricalinspectorate/ fire department for approvals-First copy |
| 74 | OD305745/2024-2025:Charges for Preparation of electrical /fire drawings in A3 sheet as per requirements for submitting electricalinspectorate/ fire department for approvals- Additional copy |
| 75 | Roofing |
| 76 | 50.10.1:Steel work in built up G I tubular ( round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting,fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete |
| 77 | 50.10.2:Steel work for purlin/single section with G I pipes including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete |
| 78 | 12.1.3:Providing corrugate G.S. sheet roofing including vertical/ curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete ( up to any pitch in horizontal / vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.0.63 mm thick with zinc coating not less than 275 gm/m2 |
| 79 | 15.7.4:Demolishing brick work manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-Charge.In cement mortar |
| 80 | 15.12.2:Dismantling doors, windows and clerestory windows (steel or wood ) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead:Of area beyond 3 sq. metres Please Enable Macros to View BoQ information |