| 1 | Solar Fencing |
| 2 | Clearing the jungle, including the uprooting of rank vegetation, grass, brush, wood,trees, and saplings . Removal of rubbish up to a distance of 50 m outside the peripheryof the area cleared (based on FSR 115- 9.884 USW/Hect) |
| 3 | OD39094/2026-2027Energiser with the following specifications:a) 12 V Energizer (i) must be from a reputed company.b) Must conform to BIS std 302-2-76 and national and international standards ofsafety.c) Switch to high and lowd) Power setting solar panel option to recharge 12 V battery.e) Should possess the following output characters:Peak output voltage not more than 10 KV on soak load.2 Output energy: 3.5 minutes 3 Pulse duration:1.01 - 3.0 msec 4 Pulse interval: 1.1 - 1.4 sec.5 Peak current: 7.0 - 8.0 A.f) 3-year warranty against manufacturing defects. |
| 4 | OD39082/2026-2027Solar module with the following specifications:1) 200 Watt 12 Volt solar module with a minimum 10-year warranty againstmanufacturing defects.2) Solar charge controller to regulate the charging of the battery.Solar Panel: IEC 61215 & IEC 61730, Charger controller IS16221 with a minimum10-year warranty from reputed companies |
| 5 | OD39099/2026-2027Module Stand with Housing Box, Galvanized material, including 2 coats of painting,accommodates 1 No. 100AH Battery, Energizer, Charge Controller, and alarm system (The contractor/supplierwill be responsible for quality assurance) |
| 6 | OD39102/2026-2027Supplying and Installation of Battery (Tubular) 100 AH/12V with 3 years replacement warranty from reputed companies and quality must be ensured. Must be capable of diverting stray lightening. The diverter assembly must be adjustable for spark gaps.Lightning diverter kit should be as close as possible to the Energiser. Adequate earthing to be provided.(The contractor/ supplier will be responsible for quality assurance) 12 V Tubular battery, IS 13369 Category: C-10 battery |
| 7 | OD39080/2026-2027Lightning Diverting Kit:Function: Must be capable of diverting stray lightning. The diverter assembly must beadjustable for spark gaps. The lightning diverter kit should be as close as possible to the Energizer.Adequate earthing to beprovided, IEC 62305, IEC 60335-2-76 |
| 8 | OD39090/2026-2027The earthing system must contain an earth mixture capable of retaining moisture.and 14 mm dia copper bonded steel, 2 m long, IS 3043 > 200 micron copper coating |
| 9 | OD39093/2026-2027Supply and fixing 50mm dia, 2.40 mtre length pipe with IS 1239 standard, 3.2 mmthickness, 350-500 GSM. including the cost of pipe, cutting, welding, painting, andfixing. |
| 10 | OD39091/2026-2027Supply and installation of supporting post, IS 1239 standard, 40mm, 3.2 mm thickness.Including the cost of pipe, cutting, welding, and proper fixing, all charges |
| 11 | OD39092/2026-2027Tension spring, stainless steel 304 grade, and non-rusting quality |
| 12 | OD39088/2026-2027A wire-tightening bolt tightener for proper tensioning of wires should be made withGI, non-rusting quality. ISO2062, galvanizing-4759, GSM-80-120 M |
| 13 | OD39100/2026-2027Strain insulator Must be of polypropylene plastic rated for 15 KV, UV stabilised. |
| 14 | OD39103/2026-2027Reel insulator , must be of polypropylene plastic rated for 15 KV, UV stabilized.PP reel Insulators |
| 15 | OD39095/2026-2027Supplying and fixing 12-gauge GI HT wire, IS 280 & IS 4826 (200-250 GSM) |
| 16 | OD39097/2026-202714-gauge GI HT binding wire, IS 280:2006, hot-dip galvanized (IS 4826), high-qualityzinc-coated wire, 200-250 GSM. |
| 17 | OD39085/2026-2027Warning sign boards - Polyethylene plastic with statutory warning and signs |
| 18 | OD39096/2026-2027Tooi kit- Includes wire tightening handle, Twisting tool, Pliers, and Double-handedspanner. from reputed companies |
| 19 | OD39089/2026-2027Lead out cable- Double insulated, withstanding 15KV voltage and inner core wire must be hot dip galvanized.For under -gate and base unit connection (EC-60335-2-76) |
| 20 | OD43611/2026-2027Supplying and laying Solar DC cable 4 mm for connecting panel to battery and chargecontroller.EN 50618. TUV Certified |
| 21 | OD39086/2026-2027Digital volt meter-Must display fence voltage, digitally up to 12KV, made of nonshockingmaterial from reputed companies. Standards: IS 1248 / IEC 60051 &IEC 61010 |
| 22 | OD39079/2026-2027Supply of C-Clamp 50mm, hot-dip galvanized, 2.5mm thickness. Standards: IS 4759,IS 2062. |
| 23 | OD39083/2026-2027Gate set for 3-1 lines - Gate with 3+1 steel ropes and handle (3+1 handles for one gate) and spring assembly to connect the strain insulator. The handle is made ofpolyethylene. |
| 24 | OD39087/2026-2027Installation charge for digging pits, proper fixing of posts with sufficient depth, andinstallation of lines as per the direction ofthe officer in charge |
| 25 | OD43675/2026-2027Supplying and fixing 12 V DC Siren with amplefire compatible with energizer. qualityproducts from reputed companies. |
| 26 | OD43677/2026-2027Supplying and fixing 1mm 2core cable for Siren Please Enable Macros to View BoQ information |