| 1 | Supplying and fixing PVC Rigid Conduit 'FR' [Precision Make] on wall, ceiling with saddles and other accessories as required and mending good damages to building works25 mm size |
| 2 | Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) of the following sizes in the prelaid polythene pipe/ PVC Rigid Conduit and by the prelaid GI fish wire and making necy. connection as required4x80/0.4 (10 sqmm) + 2x84/0.3 (6 sqmm) as ECC |
| 3 | Supply of following XLPE insulated & Sheathed cables for Working Voltage up to 1100 Volts of following sizes [Make:- Polycab/Havells/Gloster/Finolex/KEI/RR Kabel/As per choice of EIC]4 core 50 sq. mm. multy stranded Aluminium conductor Armoured cable. [Make:- Polycab/Havells/Gloster/Finolex/KEI/RR Kabel/As per choice of EIC] |
| 4 | Supplying and fixing compression type gland and finishing those for following XLPE / PVC armoured cable (2/4 / 3.5)Core as per GS. 4 Core 50 Sq. mm |
| 5 | Laying of cable having following size, on wall/ surface including S & F MS clams with earthing attachment having following size GI (Hot Dip) Wire, making hole etc. as necy., mending good damages and paintingLaying of cable from 3/3½ core 35 sqmm to 50 sqmm on wall/surface incl. S & F MS saddles with earthing attachment in 2x 10 SWG GI (Hot Dip) Wire, making holes etc. as necy., mending good damages and painting |
| 6 | S & F G.I cable looping box of size (250x150x100)mm with all accessories as per GS on wall having One nos. 230/415V, 6A, C-Curve [Legrand Make] SP MCB on DIN rail and 4 pole connector.(250x150x100)mm |
| 7 | Supplying & fixing medium gauge GI Pipe ( ISI-Medium) Protection with necessary fittings and jointing materials as required.50 mm dia. |
| 8 | Supplying and fixing double door Vertical TPN MCB Distribution board for MCCB incomer with IP-42/43 protection, on angle iron frame on wall & mending good the damages to original finish as per GS.Up to 160A, 6 Way [Make- Legrand/L&T/ABB/Siemens] |
| 9 | Supplying and fixing double-door Horizontal TPN MCB Distribution Board with IP-42/43 protection, concealed in wall as per GS.6 Way [Make- Legrand/L&T/ABB/Siemens] |
| 10 | Supplying and fixing 415 V Four Pole MCCB of Breaking capacity 25kA/35kA with fixed thermal and fixed magnetic / adjustable thermal and fixed magnetic setting in existing DBs / enclosure and necessary connection as per GS.160 A FP [Make- Legrand/L&T/ABB] |
| 11 | Supplying and fixing 240/415 V MCB Isolator on din rail of existing DBs and necessary connection as per GS.63 A FP [Make- Legrand/L&T/ABB] |
| 12 | Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection as per GS.63 A TP [Make- Legrand/L&T/ABB] |
| 13 | 6-32 A SP [Make- Legrand/L&T/ABB] |
| 14 | Dismantling main switch, existing wiring & unserviceable materials incl. Mending good the damaged and storing the dismantled materials within 500 mtrs of the site as per instruction of EIC. |
| 15 | Note: 1) All the above rates should be quoted inclusive of all taxes, duties and all ancilery charges with cost of maintenance, servicing, supply & replacement of spares for 1 (One) year from the date of commissioning. Please Enable Macros to View BoQ information |