|
| 1 | 14.7 Demolishing brick work including stacking of serviceable materials and disposal of unserviceable materials with all lift sand up to a lead of 50 m etc.complete as per direction of the Engineer- in-charge: 14.7.3 In cement mortar. |
| 2 | 5.19 Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. 5.19.4 Thermo-Mechanically Treated bars of grade Fe-500D or more |
| 3 | 5.8 Centering shuttering including struttings, propping etc. and removal of form work for: 5.8.6.1 Columns, Pillars, Piers, Abutments, Posts and Struts with shuttering ply |
| 4 | 5.8Centering shuttering including struttings, propping etc.and removal of form work for:5.8.5.1 Lintels, beams, plinth beams, girders, bressumers andcantilevers with shuttering ply |
| 5 | 4.1 Providing and laying in position cement concrete of specified grade excluding the cost of centring andshuttering --All work upto plinth level: 4.1.3 1:2:4 ( 1 Cement: 2 fine sand : 4 graded stone aggregate20 mm nominal size) |
| 6 | 5.2 Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and skirting courses, fillets, columns, pillars, piers, abutments, posts and struts etc. upto floor five level excluding cost of centring, shuttering, finishing and reinforcement-5.2.3 1:2:4 ( 1 Cement: 2 fine sand : 4 graded stone aggregate 20 mm nominal size) |
| 7 | 5.3 Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto floor five level excluding the cost of centring, shuttering, finishing and reinforcement- 5.3.3 1:2:4 ( 1 Cement: 2 fine sand : 4 graded stone aggregate 20 mm nominal size) |
| 8 | 6.1 First class brick work in foundation and plinth including cost of all materials as required complete:- 6.1.3 In cement mortar 1:4 ( 1 cement : 4 fine sand ). |
| 9 | 2.19 Supplying and filling in plinth, under floor, foundations etc. with sand (fine) from local quarry with all lifts includingspreading in horizontal layers, watering, grading to required slope, ramming, consolidating and compacting each layer by using plate compactor or by any suitable method complete. |
| 10 | 6.10 Half brick masonry work with first class bricks in foundation and plinth including cost of all materials as required complete:- 6.10.3 In cement mortar 1:4 ( 1 cement : 4 fine sand ). |
| 11 | 12.1 12 mm cement plaster of mix 12.1.2 Cement mortar 1:4 (1 cement : 4 fine sand) |
| 12 | 12.2 15 mm cement plaster on the rough side of single or half brick wall of mix: 12.2.2 Cement mortar 1:4 (1 cement : 4 fine sand) |
| 13 | 8.46 Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. all complete. 8.46.2 Fixed to openings /wooden frames with rawl plugsscrews etc. |
| 14 | 9.12 Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.9.12.1 Hot finished welded type tubes |
| 15 | 8.1 Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position : 8.1.2 Karai wood |
| 16 | 8.18 Providing and fixing ISI marked flush door shutters conforming to IS: 2202 (Part I) decorative type, core of block board construction with frame of 1st class hardwood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters.8.18.1 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws. |
| 17 | 8.5 Providing and fixing panelled / or panelled and glazed shutters for doors, windows and clerestory windows including ISI marked bright finished / black enamelled M.S butt hinges with necessary screws excluding panelling and or glazing, which will be paid for separately but including the wooden beading of 20 × 12 mm for fixing panelling and or glazing as per direction of Engineer-In-Charge.8.5.1 Local Teak wood8.5.1.1 35 mm thick shutters |
| 18 | 8.114 Providing and fixing factory made UPVC door frame made of UPVC extruded, section having an overall dimension, as below (tolerance +/- 1mm) with wall thickness 2.0mm+/- 02mm. corners of the door frame to be jointed with galvanized brackets and stainless screws, joint mitred and plastic wilded. The hinge side vertical of the frames reinforced by galvanized MS tube of size 19 × 19 mm and 1 mm +/- 0.1 mm wall thickness and 3 nos stainless steel hinges fixed to the frame complete as per manufacturers specification and direction of Engineer-in-Charge.8.114.2 Extruded section Profile size 42x50 mm. |
| 19 | 8.115 Providing and fixing to existing door frames. 8.115.2 30mm thick factory made Polyvinyl Chloride (PVC) doorshutter made of styles and rails of a UPVC profile section of size 30mm x 60mm and wall thickness 2mm ± 0.2mm with inbuilt decorative moulding edging on one side. The styles and rails with plastic brackets of size 75×220 mm mitred and welded at the corners. The styles of the shutter reinforced by inserting galvanised MS tube of size 25×20 mm and 1 mm ± 0.1 mm wall thickness. The lock rail made up of \\"H\\" Section, a UPVC profile section of size 30×100 mm and 2 mm ± 0.2 mm wall thickness welded to the shutter style with a UPVC profile section single panel of size not less than 620 mm, having overall thickness of 20 mm and 1 mm ± 0.1 mm wall thickness with 20 mm panel beading of suitable size/Glass (4 mm thick plain glass)/ louver section, louver frame of suitable size, complete as per manufacturer's specification and direction of Engineer- In-Charge. (for W.C. and Bathroom door shutter). |
| 20 | 8.61 Providing and fixing ISI marked oxidised M.S. tower bolt black finish, (Barrel type) with necessary screws etc. complete :8.61.1 250x10 mm |
| 21 | 8.64 Providing and fixing ISI marked oxidised M.S. handles conforming to IS:4992 with necessary screws etc. complete : 8.64.1 125 mm |
| 22 | 8.60 Providing and fixing ISI marked oxidised M.S.sliding door bolts with nuts and screws etc. complete 8.60.1 300×16 mm |
| 23 | 8.51 Providing 40 × 5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embedding in cement concrete block 30 × 10 × 15 cm 1:3:6 mix (1 cement : 3 fine sand : 6 graded stone aggregate 20mm nominal size) |
| 24 | 8.68 Providing and fixing IS : 12817 marked stainless steel butt hinges with stainless steel screws etc. complete :8.68.1 125 x 64 x 1.90 mm |
| 25 | 13.37 Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. |
| 26 | 12.46 Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound ) content [Payment shall be made aftersubmission of Test Certificate issued by theManufacturer]. 12.46.3 With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre |
| 27 | 12.35 Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 grams/ litre, of approved brand and manufacture to give an even shade [Payment shall be made after submission of Test Certificate issued by the Manufacturer] :12.35.1 New work ( two or more coats) over and including water thinnable priming coat with cement primer. |
| 28 | 12.41 Finishing walls with acrylic smooth exterior paint of required shade of approved brand and manufacture[Payment shall be made after submission of Test Certificate issued by the Manufacturer] :12.41.1 New work ( two or more coats applied @ 1.67 litre/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) |
| 29 | 12.45 Applying priming coat [Payment shall be made after submission of Test Certificate issued by theManufacturer] :12.45.1 With ready mixed Pink or Grey primer of approved brand and manufacture on wood work ( hard & soft wood ). |
| 30 | 12.45 Applying priming coat [Payment shall be made after submission of Test Certificate issued by theManufacturer] : 12.45.3 With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/steel works |
| 31 | 12.61 Painting with synthetic enamel paint, having VOC (Volatile Organic Compound) content less than 150 grams/ litre, of approved brand and manufacture,including applying additional coats wherever required to achieve even shade and colour [Payment shall be madeafter submission of Test Certificate issued by the Manufacturer]. 12.61.2 Two coats |
| 32 | 13.47 Painting on wood work with oil type wood preservative ( one or more coats ) of approved brand and manufacture on old work including preparation of surface as required complete as per direction of theEngineer in charge. |
| 33 | 10.54 Providing and fixing Precast chequered cement concrete tiles 18 mm thick, laid in footpath & courtyard, on 20 mm thick bed of cement mortar 1 : 4 ( 1 cement : 4 fine sand ) jointed with neat cement slurry including rubbing and cleaning etc. all complete as per direction of Engineer-in-charge.10.54.1 In dark shade using ordinary cement |
| 34 | 10.40 Providing and fixing 1st class quality ceramic glazed wall tiles conforming to IS : 15622 - 2017 (thickness to be specified by the manufacturer) of approved make in all colours, shades of any size as approved by Engineer-incharge in skirting, risers of steps and dados, laid over 12 mm thick bed of cement mortar 1 : 3 (1 cement : 3 fine sand) jointed with ordinary cement slurry including pointing with white cement mixed with pigment of matching shade etc. all complete as per direction of the Engineer in-charge. 10.40.1 450 mm X 300 mm in all shades and design |
| 35 | 10.40 Providing and fixing 1st class quality ceramic glazed wall tiles conforming to IS : 15622 - 2017 (thickness to be specified by the manufacturer) of approved make in all colours, shades of any size as approved by Engineer-incharge in skirting, risers of steps 10.42 Providing and laying 1st class quality vitrified floor tiles in different sizes (thickness to be specified by themanufacturer) with water absorption less than 0.08% and conforming to IS: 15622 - 2017, of approved make, in all colours and shades, laid over 20mm thick cement mortar 1:4 (1 cement : 4 fine sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints withwhite cement and matching pigments etc. all complete as per direction of the Engineer-in-charge. 10.42.4 Glazed Vitrified Tiles - Full Body (Glossy / Mat Finish/Anti-Skid)10.42.4.1 Size of tile 600 mm x 600 mm |
| 36 | 19.54 Providing and fixing PTMT bib cock of approved quality and colour. 19.54.4 15mm nominal bore, 90 mm long, weighing not less than 93 gms. |
| 37 | 18.7 Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps,32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require :18.7.1 White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps |
| 38 | 18.31 Providing and fixing 600x450 mm bevelled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. |
| 39 | 18.73 Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fitting arrangement of approved qualityand colour. 18.73.2 600mm long towel rail with total length of 645mm, width 78mm and effective height of 88mm, weighing not less than 190gms. |
| 40 | 19.12 Providing and fixing G.I. pipes of medim class as per IS : 1239 with latest amendment complete with G.I.fittings including trenching and refilling etc. complete as per CPWD specification and direction of the Engineer - in - charge.External work 19.12.2 20 mm dia. nominal bore |
| 41 | 18.28 Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. 18.28.2 Flexible pipe18.28.2.1 32 mm dia |
| 42 | 19.7 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain &brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cementand testing of joints complete as per direction of Engineer in Charge.Internal work - Exposed on wall 19.7.2 20 mm nominal outer dia .Pipes. |
| 43 | 18.84 Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised RigidPVC soil, waste & vent pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion: 18.84.5 Bend 87.5°18.84.5.1 75mm |
| 44 | 18.18 Providing and fixing P.V.C. low level flushing cistern with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete.18.18.1 10 litre capacity-White |
| 45 | 19.22 Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet: 19.22.2 150 mm diameter |
| 46 | 11.22 Supply & installation of pre-painted Galvalume sheets for roofing/cladding (size, shape and pitch of corrugation as approved by Engineer-in-charge) in 550mpa steel grade, made out of Cold Rolled Steel coated with Zinc-Aluminium alloy coating of 43.5% Zn, 55% Al and 1.5% Silicon confirming to ASTM A792/A792M and AS1397, Alloy coating AZ150/AZ70, colour coated with high quality Polyester coating, top coated of modified polyester of 20 micron, back side coat of 5 micron, having epoxy primer coat of 5 micron on both side. Sheet should have protective guard film of 25 microns minimum to avoid scratches while transportation and should be supplied in single length upto 12 metre or as desired by Engineer-incharge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55mm) with EPDM washers filled with white lead complete upto any pitch in horizontal/ vertical or curved surfaces excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required and as per direction of Engineer-in-charge. 11.22.3 0.50mm thickness |
| 47 | 11.23 Supply & installation of pre-painted Galvalume sheets roofing accessories in 550mpa steel steel grade, madeout of Cold rolled steel coated with Zinc-Aluminium alloy coating of 43.5% Zn, 55% Al and 1.5% Silicon confirming to AASTM A792/A792M and AS1397, Alloy coating AZ150/AZ70, colour coated with high quality polyester coating, top coated of modified polyester of 20 micron, back side coat of 5 micron, having epoxy primer coat of 5 micron on both side etc. complete as per direction of Engineer-in-charge. Sheet should have protective guard film of 25 microns minimum to avoid scratches while transportation. Sheet should have protective guard film of 25 microns minimum to avoid scratches while transportation. The sheet shall be fixed using self drilling /self tapping screws with EPDM washers complete forRidges/Valley/Gutter/Flashing of width 610mm: 11.23.3 0.50mm thickness |
| 48 | 11.40 Providing and fixing mineral fibre false ceiling tiles at all heights of size 595X595mm of approved texture, design and pattern. The tiles should have Humidity Resistance (RH) of 99%, Light Reflectance ?85%, Thermal Conductivity k = 0.052 - 0.057 w/m K, Fire Performance as per (BS 476 pt - 6 &7)in true horizontal level suspended on interlocking TGrid of hot dipped all round galvanized iron section of 0.33 mm thick (galvanized @120 gsm ) comprising of main T runners of 15x32 mm of length 3000 mm, cross T of size 15x32mm of length 1200 mm and secondary intermediate cross T of size 15x32 mm of length 600 mm to form grid module of size 600x600 mm suspended from ceiling using galvanized mild steel item (galvanised@80gsm) 50 mm long 8mm outer diameter M-6 dash fasteners, 6 mm diameter fully threaded hanger rod up to 1000 mm length and L-shape level adjuster of size 85x25x2 mm, spaced at 1200 mm centre to centre along main ‘T’. The system should rest on periphery walls /partitions with the help of GI perimeter wall angle of size24x24X3000 mm made of 0.40 mm thick sheet, to be fixed to the wall with help of plastic rawl plug at 450 mm centre to centre & 40 mm long dry wall S.S. screws. The exposed bottom portion of all Tsections used in false ceiling support system shall be prepainted with polyester baked paint, for all heights. The work shall be carried out as per specifications, drawings and as per direction of Engineer-in-charge.11.40.1 With 16 mm thick beveled tegular mineral fibre false ceiling tile (NRC 0.55 to 0.6). Please Enable Macros to View BoQ information |