| 1 | Total amount of the \\"Rate Schedule\\" sheet SCHEDULE OF QUANTITY AND RATE FOR REPLACEMENT OF ACSR CONDUCTOR BY 11 KV AAAC AL-59, 99 SQMM. COVERED CONDUCTOR AT FOREST AREA OF NAYAGAON FEEDER UNDER EDSD, GANESHPUR UNDER EDD, MOHANPUR AGAINST E-TENDER SPECIFICATION NO.28/EDCRDDUN/2026-27 Name of The Bidder's Firm: 0.0 Sl. No. Description of Work Unit Qty Rate Amount Part [A] (Supply Portion) |
| 2 | Holding Clamp for ST Pole SP-33 With N&B |
| 3 | Stay Clamp for ST Pole SP-23 with Nut & Bolt |
| 4 | 11 KV IPC for Covered to Covered Conductor |
| 5 | 11 KV IPC for Covered to Bare Conductor |
| 6 | 11 KV Mid Span Jointing Kit |
| 7 | 11 KV IPC with Aluminium Bail for Earthing |
| 8 | 11 KV Suspension Ties/Cable Ties on Pin Insulator |
| 9 | 11 KV AAAC Covered Conductor AL-59, 99 Sqmm. |
| 10 | 11 KV Tension Clamp with Bail & IPC Total - Part [A] 0.0 Part [B] (Labour Portion) |
| 11 | Cartage of ST pole from store centre to construction site with loading, unloading at both points and proper stacking. (21-50 Km.) SP-33 Nos 15.0 0.0 |
| 12 | Cartage of other material (other than poles) by vehicle fro Store Center to nearest construction site Store including loading and unloading at both ends. (21-50 Km.) Rs.Per Qtl. Qtl 10.0 0.0 |
| 13 | Head load cartage of following Poles from road to site. Upto 0 to 1 Km. SP-33 Nos 15.0 0.0 |
| 14 | Head load cartage of Small material. Rates are per Km/Quintal including loading and Unloading. Upto 0 to 1 Km. Qtl 10.0 0.0 |
| 15 | Chemical Earthing:Earthing of distribution transformer including digging of pit of size 2.5 Mtr depth and make hole of size 150 mm. Placing of earthing electrode (to be supplied by contractor as per drawing No. A) as drawing B, connecting the same with G.I. Strip (to be supplied by contractor ) of size 35x6 mm as per drawing C for a minimum lenght 6 m. treatment of soil with highly condctive substance as per IS 30343 complete in all respect, result of earthing resistance to be recroded in M.B. before and after installation of earthing. The earth resistance after earthing should be less than 1 Ohm. |
| 16 | Fabrication of M.S. Channel Angle iron after cutting in required sizes with drilling of holes upto good finish for top channel, bracing and special type bracket etc. as per RESPO sehedule and local approved drawing. |
| 17 | Excavation of earth for stay pit of size 0.06x0.06x1/2 mtr. in all type of soil including proper dressing of sides and ramming of bottom including getting out the excavated soil and disposal of surplus excavated soil as directed complete work |
| 18 | Fixing , tightening and nozzaling of Stay with pole and stay rod on required tension as per drawing / RESPO manual. 11 KV line Nos 25.0 0.0 |
| 19 | Grouting of Stay in size 0.6x0.6x0.3 in CC ratio 1:4:8 (1 cement : 4 graded stone 20mm nominal size : 8 coarse sand ) block including cost of Cernent, sand and stone ballast back filling of soil and boulders in pit and ramming and proper alignment, leveling as per RESPO Manual. |
| 20 | Excavation of earth for pole pit of size 0.9x0.6x1/6 of full length of pole for erection of pole in all type of soil including proper dressing of sides and ramming of bottom including getting out the excavated soil and disposal of surplus excavated soil as directed complete work |
| 21 | Erection of following Single support pole in proper level and alignment alongwith fixing of all accessories, like top channel & clamps as per RESPO construction Manual. SP-33 Nos 15.0 0.0 |
| 22 | Grouting of pole in size 0.45x0.45x1/9 of the support in CC ratio 1:4:8 (1 cement : 4 graded stone 20mm nominal size : 8 coarse sand ) block including cost of Cement,sand and stone ballast back filling of soil and boulders in pit and ramming and proper alignment, leveling as per RESPO construction Manual. |
| 23 | Muffing of poles size 0.45 cm x 0.60 cm radius with cc 1:3:6 (1 cement: 3 coarse sand : 6 graded stone 10mm nominal size) block size 45cm height from ground level including cost of cement, stone and sand etc. |
| 24 | Route cleareance by cutting of tree branches / proning, lopping and chopping of trees for L.T., 11 & 33 KV line. |
| 25 | Straightening of Tilted ST Pole |
| 26 | Fixing of IPC with Aluminium Bail for Earthing |
| 27 | Jumper Section Pole |
| 28 | Fixing of 11 KV 90KN Tension Clamp B&IPC |
| 29 | Fixing of 11 KV Suspension Ties |
| 30 | Fixing of 11 KV Mid Span Jointing Kit |
| 31 | Fixing of 11 KV IPC for Covered to Covered Conductor |
| 32 | Fixing of 11 KV IPC for Covered to Bare Conductor |
| 33 | Supply & Fixing of Anti Climbing Device |
| 34 | Dismantling & Rejumpering of Conductor |
| 35 | Laying, Spreading, Stringing of AAAC Conductor |
| 36 | Removing Old Conductor by Opening Jumper |
| 37 | Painting of poles with angle and channel and all steel part by one coat of Rod Oxide Primer and two coats of aluminium Paint and two strip of fluorescent altemate Red and White paint 30 Cm wide upto 1.5 Mtrs. From ground level. |
| 38 | Back Cartage of Petty material, 0-20 Km. |
| 39 | Back Head load Cartage of petty material, 0-1 Km. Total - Part [B] 0.0 TOTAL [Part-(A) + Part (B)] 0.0 Place Date Superintending Engineer Please Enable Macros to View BoQ information |