| 1 | COST OF MATERIAL |
| 2 | Supply of 9.0 meters long R.C.C. Pole as per drawing No.CEE/E-565 Rev-3 and conforming to IS 785-1998 as amended upto date. The Component used for pole shall conform to following IS amended upto date.Ordinary Port land cement 53 grade : IS 12269Aggregate : IS 383-1970Torsteel : IS 1786-7985MS bar : IS 432 P 1&2-1982Erection includes transpotation, dragging of pole to the site of pit, clearing of bushes etc and excavation of pit of Size 0.60 x 0.60 x 1.5 mts in any type of soil classified under Soft Strata of Appendix A of CPWD-8 and back filling the pit after erection of the pole in pit by rubbleand excavated soil as shown in the Drg No. EE/IV/LT9.0RCC. ( Rubble is dealt seperately) |
| 3 | Supply of 7.5 meters long R.C.C. Pole as per drawing No.CEE/E-724 Rev 3 and conforming to IS 785-1998 as amended upto date. The Component used for pole shall conform to following IS amended upto date.Ordinary Port land cement 53 grade : IS 12269Aggregate : IS 383-1970Torsteel : IS 1786-7985MS bar : IS 432 P 1&2-1982Erection includes transpotation, dragging of pole to the site of pit, clearing of bushes etc and excavation of pit of Size 0.60 x 0.60 x 1.25 mts in any type of soil classified under Soft Strata of Appendix A of CPWD-8 and back filling the pit after erection of the pole in pit by rubble and excavated soil as shown in the Drg No. EE/IV/LT7.5RCC. ( Rubble is dealt seperately) |
| 4 | Supply of HDGI stay rod with plate complete for for 7.5 m long RCC pole as per technical specification. ( Rubble is dealt seperately) |
| 5 | Supply of Enamelled danger board as per DRG No. CEE/490 |
| 6 | Supply of HDGI stay rod with plate complete for 9 m long RCC pole as per technical specification ( Rubble is dealt seperately) |
| 7 | Supply of HDGI L.A./S.A. cross arm clamps suitable for 7.5 RCC pole as per Drg No. CEE/E-524. |
| 8 | Supply of MS Distribution Box alongwith 12nos. 200A Kit Kat fuse and MCCB of 400Amps, 415 Volts. The box shall be fabricated with MS sheet 12 gauge with overlapping rain proof slit ventilators on both sides of the distribution box with wire mesh to prevent entry of insects with pin head door hinges locking arrangement and shall have required number of bus bars made out of Aluminium strips of size 40 x 10mm for connecting MCCB, fuses and cables (for 4 feeder arrangement) & other accessories. The box shall also have 'magnetic hold' arrangement to ensure that the box doors always remains in 'closed' positiion when shut even without latching. |
| 9 | Supply of 100KVA, 11/0.433KV 3 PH. Aluminium Wound Distribution Transformer level -II |
| 10 | Earthing complete with 40mm GI Pipe, 2.5 mts long alongwith 20 kgs each salt, charcoal complete with brick masonary. |
| 11 | Supply of AAC ' ANT ' conductor of size 7/3.14mm. The stringing rate includes transportation, jointing, etc. 7.44 Kms of conductor shall be strung as phases for LT line. The conductor shall be comply to the technical specification. |
| 12 | Supply of AAC ' GNAT ' size 7/2.21mm conductor for neutral, streetlight and jumpering as well as guarding. The conductor shall be comply to technical specification. |
| 13 | Supply of HDGI 4 pin LT cross arm channel type as per Drg. No. CEE/E/705. |
| 14 | Supply of HDGI 2 pin LT cross arm channel type as per Drg. No. CEE/E/704. |
| 15 | Supply of a) L.T. brown glazed porcelain pin insulators of size 100mm x 70mm conforming to type 1 fig 1 of IS:1445/1977 with amendment 2 of Feb.1981 (second revision) as amended upto date. Minimum failing load shall be 3.5kN & b) Forged G. I. Pin conforming to IS 7935/1975 as amended upto date suitable for L.T. porcelain pin insulator type 1 conforming to fig.1 of IS: 1445/77 with amendment No. 2, Feb.1981, of size 100 x 70 mm. G. I. pin shall comprise of G. I. nut and spring washer and conform to fig. No. 2 of IS: 7935/1975. Minimum failing load of pin shall be 3.5 KN. The LT Pin Insulator shall be as per technical specification. |
| 16 | Supply of a) L.T. brown glazed shackle insulators of size 100mm x 115mm conforming to fig.No.4 and type 2 of IS: 1445/77 as amended upto date. Minimum failing load shall be 16kN & b) G. I hardware suitable for L. T. shackle insulators of size 100 x 115 mm. conforming to type 2, fig. 4 of IS: 1445/77 as amended upto date. Hardware or fitting shall conform to fig. 4 of IS 7935-1975 as amended up to date, comprise of 2 G. I. strips, 2 G. I. bolts and 2 nuts with spring washers. The LT shackel insulator shall be as per Technical specification. |
| 17 | Supply HDGI G.I. Hexagonal head bolts and hexagonal nuts conforming to IS 1363 part I to III 1992 as amended upto date of the size 3 ½\\" x 5/8\\" or 4\\" x 5/8\\",6\\"x5/8\\", 8\\"x5/8\\" or as per the requirement. |
| 18 | Providing of Low Tension metering to the DTC by Suplying, Installing and commissioning of following Materials:1)Epoxy resin Cast L.T. CT coil of 300/5A, Class-0.5s, 50Hz,660V, Burden 15VA conforming to IS-2705 / 1992 as amended upto date2) Electronic 3Phase,4wire ,Trivector Meter ,LT CT operated 3x240V,-/5A,50Hz, class 0.5s, Category \\"A\\" (DLMS COSEM Protocol) for DTC with RS 232 Optical port and complience to BIS ICS Doc: ETD 13(6211) and latest.3)1.1KV multistand copper conductor 2.5sq.mm, XLPE insulated, armoured control cable conforming to relevant IS amended upto date.4)Pole mounted M.S Box ( outdoor type) for Electronic Meter as Drawing No.EE/VIII/64(REV)5)Al. L shape flat 40mm suitable for mounting on bushing rod and brass lug |
| 19 | Supply & Erection of single cores, 185sq.mm, unarmoured Al conductor PVC insulated 1.1KV grade power cable as per Technical Specification and as per IS:7098 (Part-I/1988) with latest ammendment carrying ISI mark. |
| 20 | Supply of Alluminium Crimping lug 185 sq.mm |
| 21 | Supply of 3 core, 300 sq.mm. Al conductor, XLPE insulated, armoured cable |
| 22 | Supply of 3 core, 95 sq.mm. Al conductor, XLPE insulated, armoured cable( From RMU to Transformer) |
| 23 | Supply of XLPE cable armoured 3 ½ core 120sqmm 1.1kv grade. |
| 24 | Supply of H.S.11 KV Termination kit indoor 300 sqmm. XLPE 3 core |
| 25 | Supply of H.S.11 KV Termination kit indoor 95 sqmm. XLPE 3 core |
| 26 | Supply of H.S 11K V Straight through joint 3 core, 300 SQMM |
| 27 | Supply of H.S.11 KV Termination kit outdoor 95 sqmm. XLPE 3 core |
| 28 | Supply of 3 WAY RMU, 11KV, 630A, 21 kA 3Sec, SF6 Outdoor RMU – 2LBS + 1CB Extensible/Non-Extensible Two (2) Motor operated load break switches (LBSs) with Manual operated earthing switches in SF6 and One (1) vacuum circuit breaker with Electrical closing and tripping along with disconnector and earthing switches SCADA Compatible and base channel. Battery charger along with batteries required for Electrical operations of RMU is in the scope of the Bidder. Each module shall consist of VPIS, FPI in LBS Module (N-1) but not less than 1 no’s per RMU. Suitable arrangement for mounting FRTU, modem or Ethernet Switch/LIU along with battery, battery charger shall be provided in RMU. |
| 29 | Supply of Cable route Markers (for entire route length) |
| 30 | Warning tape |
| 31 | Supply of Riser GI pipe 150mm, class B. |
| 32 | Supply and laying of fine river sand of approved quality (except sandy soil) for cushioning of the underground cables in the trench. |
| 33 | Supply of Cuddappa of size 600mm length x 250mm width and 1 inch thick and covered with earth/ sand upto depth of 0.15mts. Confirming to IS 1255-1967 at non-road crossing. |
| 34 | Providing and laying in position cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded granitic or basaltic stone aggregate 40 m nominal size for foundation of Transformer and Ring Main Unit |
| 35 | Centering and shuttering including struttings, propping etc and removal of form work for Transformer and Ring Main Unit |
| 36 | Plastering of 12 mm cement plaster 1:4 (1- cement: 4-fine sand ) for foundations of Transformer and Ring Main Unit |
| 37 | Brick work using common burnt building bricks in cement mortar 1:4 (1 cement: 4 coarse sand) with bricks of class designation 75 kgs/ cm2 (wire cut bricks) |
| 38 | Supply of GI Flat 25 x 5 mm |
| 39 | Supply of GI Tubular Fencing complete with gate and side dismantling syatem as per the specification for distribution transformers and feeder Pillars (size 4M X 3M X 2M) with concreting for GI fencing supports with plinth(0.3x0.3x0.5) Cu.mx12 nos. Each ratio 1:3:6 and brick masonary [Galvanising should be hot dipped Galvanised as per IS:2629/66, minimum Zinc coating of 1000 gms/sq.mtr, 140 Microns DFT, suitable for high salinity coastal areas]. |
| 40 | Supply and laying of burnt clay wire cut bricks of 75 Kgs class.Wire cut bricks. |
| 41 | COST OF ERECTION |
| 42 | Erection of 9.0 meters long R.C.C. Pole as per drawing No.CEE/E-565 Rev-3 and conforming to IS 785-1998 as amended upto date. The Component used for pole shall conform to following IS amended upto date.Ordinary Port land cement 53 grade : IS 12269Aggregate : IS 383-1970Torsteel : IS 1786-7985MS bar : IS 432 P 1&2-1982Erection includes transpotation, dragging of pole to the site of pit, clearing of bushes etc and excavation of pit of Size 0.60 x 0.60 x 1.5 mts in any type of soil classified under Soft Strata of Appendix A of CPWD-8 and back filling the pit after erection of the pole in pit by rubbleand excavated soil as shown in the Drg No. EE/IV/LT9.0RCC. ( Rubble is dealt seperately) |
| 43 | Erection of 7.5 meters long R.C.C. Pole as per drawing No.CEE/E-724 Rev 3 and conforming to IS 785-1998 as amended upto date. The Component used for pole shall conform to following IS amended upto date.Ordinary Port land cement 53 grade : IS 12269Aggregate : IS 383-1970Torsteel : IS 1786-7985MS bar : IS 432 P 1&2-1982Erection includes transpotation, dragging of pole to the site of pit, clearing of bushes etc and excavation of pit of Size 0.60 x 0.60 x 1.25 mts in any type of soil classified under Soft Strata of Appendix A of CPWD-8 and back filling the pit after erection of the pole in pit by rubble and excavated soil as shown in the Drg No. EE/IV/LT7.5RCC. ( Rubble is dealt seperately) |
| 44 | Erection of HDGI stay rod with plate complete for for 7.5 m long RCC pole as per technical specification. ( Rubble is dealt seperately) |
| 45 | Erection of Enamelled danger board as per DRG No. CEE/490 |
| 46 | Erection of HDGI stay rod with plate complete for 9 m long RCC pole as per technical specification ( Rubble is dealt seperately) |
| 47 | Fixing of HDGI L.A./S.A. cross arm clamps suitable for 7.5 RCC pole as per Drg No. CEE/E-524. |
| 48 | Erection and commissioning of MS Distribution Box alongwith 12nos. 200A Kit Kat fuse and MCCB of 400Amps, 415 Volts. The box shall be fabricated with MS sheet 12 gauge with overlapping rain proof slit ventilators on both sides of the distribution box with wire mesh to prevent entry of insects with pin head door hinges locking arrangement and shall have required number of bus bars made out of Aluminium strips of size 40 x 10mm for connecting MCCB, fuses and cables (for 4 feeder arrangement) & other accessories. The box shall also have 'magnetic hold' arrangement to ensure that the box doors always remains in 'closed' positiion when shut even without latching. |
| 49 | Erection, testing and commissioning of 100KVA, 11/0.433KV 3 PH. Aluminium Wound Distribution Transformer level -II |
| 50 | Earthing complete with 40mm GI Pipe, 2.5 mts long alongwith 20 kgs each salt, charcoal complete with brick masonary. |
| 51 | Stringing of AAC ' ANT ' conductor of size 7/3.14mm. The stringing rate includes transportation, jointing, etc. 7.44 Kms of conductor shall be strung as phases for LT line. The conductor shall be comply to the technical specification. |
| 52 | Stringing of AAC ' GNAT ' size 7/2.21mm conductor for neutral, streetlight and jumpering as well as guarding. The conductor shall be comply to technical specification. |
| 53 | Fixing of HDGI 4 pin LT cross arm channel type as per Drg. No. CEE/E/705. |
| 54 | Fixing of HDGI 2 pin LT cross arm channel type as per Drg. No. CEE/E/704. |
| 55 | Fixing of a) L.T. brown glazed porcelain pin insulators of size 100mm x 70mm conforming to type 1 fig 1 of IS:1445/1977 with amendment 2 of Feb.1981 (second revision) as amended upto date. Minimum failing load shall be 3.5kN & b) Forged G. I. Pin conforming to IS 7935/1975 as amended upto date suitable for L.T. porcelain pin insulator type 1 conforming to fig.1 of IS: 1445/77 with amendment No. 2, Feb.1981, of size 100 x 70 mm. G. I. pin shall comprise of G. I. nut and spring washer and conform to fig. No. 2 of IS: 7935/1975. Minimum failing load of pin shall be 3.5 KN. The LT Pin Insulator shall be as per technical specification. |
| 56 | Fixing of a) L.T. brown glazed shackle insulators of size 100mm x 115mm conforming to fig.No.4 and type 2 of IS: 1445/77 as amended upto date. Minimum failing load shall be 16kN & b) G. I hardware suitable for L. T. shackle insulators of size 100 x 115 mm. conforming to type 2, fig. 4 of IS: 1445/77 as amended upto date. Hardware or fitting shall conform to fig. 4 of IS 7935-1975 as amended up to date, comprise of 2 G. I. strips, 2 G. I. bolts and 2 nuts with spring washers. The LT shackel insulator shall be as per Technical specification. |
| 57 | Fixing HDGI G.I. Hexagonal head bolts and hexagonal nuts conforming to IS 1363 part I to III 1992 as amended upto date of the size 3 ½\\" x 5/8\\" or 4\\" x 5/8\\",6\\"x5/8\\", 8\\"x5/8\\" or as per the requirement. |
| 58 | Providing of Low Tension metering to the DTC by Suplying, Installing and commissioning of following Materials:1)Epoxy resin Cast L.T. CT coil of 300/5A, Class-0.5s, 50Hz,660V, Burden 15VA conforming to IS-2705 / 1992 as amended upto date2) Electronic 3Phase,4wire ,Trivector Meter ,LT CT operated 3x240V,-/5A,50Hz, class 0.5s, Category \\"A\\" (DLMS COSEM Protocol) for DTC with RS 232 Optical port and complience to BIS ICS Doc: ETD 13(6211) and latest.3)1.1KV multistand copper conductor 2.5sq.mm, XLPE insulated, armoured control cable conforming to relevant IS amended upto date.4)Pole mounted M.S Box ( outdoor type) for Electronic Meter as Drawing No.EE/VIII/64(REV)5)Al. L shape flat 40mm suitable for mounting on bushing rod and brass lug |
| 59 | Erection of single cores, 185sq.mm, unarmoured Al conductor PVC insulated 1.1KV grade power cable as per Technical Specification and as per IS:7098 (Part-I/1988) with latest ammendment carrying ISI mark. |
| 60 | Crimping of Alluminium Crimping lug 185 sq.mm |
| 61 | Erection, Testing and Comissioning of 3 core, 300 sq.mm. Al conductor, XLPE insulated, armoured cable |
| 62 | Erection, Testing and Comissioning of 3 core, 95 sq.mm. Al conductor, XLPE insulated, armoured cable( From RMU to Transformer) |
| 63 | Erection of XLPE cable armoured 3 ½ core 120sqmm 1.1kv grade. |
| 64 | Erection of H.S.11 KV Termination kit indoor 300 sqmm. XLPE 3 core |
| 65 | Erection of H.S.11 KV Termination kit indoor 95 sqmm. XLPE 3 core |
| 66 | Erection of H.S 11K V Straight through joint 3 core, 300 SQMM |
| 67 | Erection of H.S.11 KV Termination kit outdoor 95 sqmm. XLPE 3 core |
| 68 | Erection, testing & comissioning of 3 WAY RMU, 11KV, 630A, 21 kA 3Sec, SF6 Outdoor RMU – 2LBS + 1CB Extensible/Non-Extensible Two (2) Motor operated load break switches (LBSs) with Manual operated earthing switches in SF6 and One (1) vacuum circuit breaker with Electrical closing and tripping along with disconnector and earthing switches SCADA Compatible and base channel. Battery charger along with batteries required for Electrical operations of RMU is in the scope of the Bidder. Each module shall consist of VPIS, FPI in LBS Module (N-1) but not less than 1 no’s per RMU. Suitable arrangement for mounting FRTU, modem or Ethernet Switch/LIU along with battery, battery charger shall be provided in RMU. |
| 69 | Erection and Comissioning of Cable route Markers (for entire route length) |
| 70 | Erection of Riser GI pipe 150mm, class B. |
| 71 | Excavation of pit of sizes(0.6x1.1x1800)mts in any type of soil for laying of 11KV cable of sizes 3 core 300 sq.mm and 3 core 95 sq.mm and LT cable of size 3 ½ core 150 sq.mm and 3 ½ core 120 sq.mm respectively. |
| 72 | Disposal Of excavated soil |
| 73 | Filling of available excavated earth (excluding rock/stones) in trench, plinth, sides, foundations etc. in layer not exceeding 0.2mts. Depth, consolidating each deposited layer by ramming and watering lead up to 25mts. |
| 74 | laying of Cuddappa of size 600mm length x 250mm width and 1 inch thick and covered with earth/ sand upto depth of 0.15mts. Confirming to IS 1255-1967 at non-road crossing. |
| 75 | Erection of GI Flat 25 x 5 mm |
| 76 | Erection of GI Tubular Fencing complete with gate and side dismantling syatem as per the specification for distribution transformers and feeder Pillars (size 4M X 3M X 2M) with concreting for GI fencing supports with plinth(0.3x0.3x0.5) Cu.mx12 nos. Each ratio 1:3:6 and brick masonary [Galvanising should be hot dipped Galvanised as per IS:2629/66, minimum Zinc coating of 1000 gms/sq.mtr, 140 Microns DFT, suitable for high salinity coastal areas]. Please Enable Macros to View BoQ information |